Loading...
BXL00642_843595_DENTON_TAP_SANDY_LAKE_AT&T_PRIORITY_FCD_REV_0_02.26.2021_ss_v1.ADM_APPAT&T AT&T SITE NUMBER: DXL00642 BUSINESS UNIT #: AT&T SITE NAME: DENTON TAP/SANDY LAKE SITE ADDRESS: AT&T FA CODE: 10077742 COUNTY: AT&T PACE NUMBER: MRNTX069637 TOWER HEIGHT: SITE TYPE: MONOPOLE SITE INFORMATION CROWN CASTLE USA INC. DENTON TAP/SANDY LAKE SITE NAME: SITE ADDRESS: 440 NORTH DENTON TAP COPPELL, TX 75019 COUNTY: DALLAS MAP/PARCEL #: NOT AVAILABLE AREA OF CONSTRUCTION: EXISTING LATITUDE: 32° 58' 48.81" LONGITUDE: -96o 59' 33.07" LAT/LONG TYPE: NAD83 GROUND ELEVATION: 469 FT. CURRENT ZONING: M JURISDICTION: CITY OF COPPELL OCCUPANCY CLASSIFICATION: U TYPE OF CONSTRUCTION: IIB A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION PROPERTY OWNER NOT AVAILABLE TOWER OWNER-- CARRIER/APPLICANT: ELECTRIC PROVIDER: TELCO PROVIDER: CROWN CASTLE USA INC. 2000 CORPORATE DRIVE CANONSBURG, PA 15317 AT&T TOWER ASSET GROUP 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 ONCOR (888) 313-6862 NOT AVAILABLE PROJECT TEAM A&E FIRM: POD 11490 BLUEGRASS PARKWAY LOUISVIL.LE, KY 40299 (502) 437-5252 CROWN CASTLE 1701 DIRECTORS BLVD, SUITE 700 USA INC. DISTRICT AUSTIN, TX 78744 CONTACTS: BARCLAY HAWLEY - PROJECT MANAGER JOE MCCALL - CONSTRUCTION MANAGER JOSEPH OLSEN - A&E SPECIALIST J OSEPH.OLSEN@CRO WNCASTLE. COM (763) 852-0573 PROJECT: AT&T PRIORITY DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET T-2 GENERAL NOTES C-1 SITE PLAN C-2 TOWER ELEVATION & ANTENNA PLANS C-3 EQUIPMENT DESCRIPTION TABLE C-4 DETAILS C-5.1 EQUIPMENT SPECS C-5.2 EQUIPMENT SPECS C-5.3 EQUIPMENT SPECS G-1 GROUNDING SCHEMATIC G-2 GROUNDING DETAILS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11X17. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. PROJECT DESCRIPTION THE PURPOSE OF THIS PROJECT IS TO PROPOSE AN ANTENNA MODIFICATION ON AN EXISTING WIRELESS SITE. FINAL TOWER CONFIGURATION: • (12) ANTENNAS • (1) MW DISH • (1) ODU • (15) RRHs • (3) DIPLEXERS • (4) SQUIDS • (18) COAX CABLES (7/8'� • (2) COAX CABLES (3/8'� • (6) DC CABLES (3/4'� • (2) DC CABLES (7/8'� • (1) FIBER CABLE (1/8'� • (3) FIBER CABLES (3/8'� • (4) INNERDUCT CONDUITS (2") FINAL GROUND CONFIGURATION: • NO CHANGES DESIGN PACKAGE BASED ON THE APPLICATION ID:541534 REVISION: 0 LOCATION MAP a 0 4> rrar •:ev Ur o C O - n o c E r o („ ON rr0,r Cry k ° W Parkway Blvd 9 v �A Andy Brown Park West 32.980225, -96.992523 ejL o• 843595 440 NORTH DENTON TAP COPPELL, TX 75019 DALLAS 80'-011 Cottonwood Branch Coy v � o r °owOodgranch Walgreens v Z Cross Ti be,s Tra11 � ,ae sac Buddy Echols Field DRIVING DIRECTIONS FROM DFW INTERNATIONAL AIRPORT (2400 AVIATION DR, DFW AIRPORT, TX 75261) 1. FOLLOW INTERNATIONAL PKWY TO TX-121 IN COPPELL. TAKE THE TX-121 N EXIT FROM TX-121 N. 2. CONTINUE ONTO TX-121. 3. TURN RIGHT ONTO N DENTON TAP RD. 4. TURN LEFT. APPLICABLE CODES ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING 2015IBC MECHANICAL 2015IMC ELECTRICAL 2014 NEC INSTALLER NOTE: TOWER DOES NOT HAVE CLIMBING FACILITIES — MANLI FT REQUIRED FOR ELEVATED WORK. NOTE: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT (800) 788-701 1& CROWN CONSTRUCTION MANAGER The Core r.. n v Andy Brown Park East 4 $d r QatK�a��NNd � L� CFestn"t Alex D, Beechwoo NO SCALE REFERENCE DOCUMENTS: STRUCTURAL ANALYSIS: B+T GROUP DATED: FEBRUARY 25, 2021 MOUNT ANALYSIS: INFINIGY ENGINEERING, PLLC DATED: FEBRUARY 16, 2021 Planning Administrative Approval COPPELL s ,(„I `r __6511-e2 05/13/2021 ® CALL TEXAS ONE CALL o (L3 DIGINGD CALL 3 WORKING DAYS BEFORE YOU DIGI AT&T 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 0 CROWN CASTLE 1701 DIRECTORS BLVD, SUITE 700 AUSTIN, TX 78744 44 � POD I POWER OF DESIGN 11490 BLUEGRASS PKWY LOU ISVI LLE, KY 40299 502-437-5252 AT&T SITE NUMBER: DXL00642 BU #: 843595 v TAP/SANDY 440 NORTH DENTON TAP COPPELL, TX 75019 EXISTING 80'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRI7DON DES./QA 0 02/26/21 NH CONSTRUCTION MEP OF � 1 ............:......'r.* MARK E. PATTERSON ,....1..... .....I.... l,0%. 113892 :'�, FiS�ONAL E�� 02/26/2021 TEXAS FIRM NUMBER 16059 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: T-1 1 0 CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS: GENERAL NOTES: ELECTRICAL INSTALLATION NOTES: 1. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE TO PROCEED (NTP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN CASTLE USA INC. NOC AT 800-788-7011 & THE CROWN CASTLE USA INC. CONSTRUCTION MANAGER. 2. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. POO OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL REQUIREMENTS. 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI ASSE A10.48 LATEST EDITION ; FEDERAL STATE AND LOCAL REGULATIONS: AND ANY APPLICABLE / ( ). INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI ASSE A10.48 ( LATEST EDITION AND CROWN CASTLE USA INC. STANDARD CED-STD-10253, INCLUDING THE REQUIREDINVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). 5. ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWN CASTLE USA INC. TOWER SITE," CED-STD-10294 "STANDARD FOR INSTALLATION OF MOUNTS AND APPURTENANCES," AND LATEST VERSION OF ANSI/TIA-1019-A-2012 "STANDARD FOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY PROCEDURES. 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATEST APPROVED REVISION. 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, TOWER OWNER, CROWN CASTLE USA INC., AND/OR LOCAL UTILITIES. 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. GREENFIELD GROUNDING NOTES: 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER: AT&T TOWER OWNER: CROWN CASTLE USA INC. 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY. 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. S. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 6. PRIOR TO THE SUBMISSION OF BIDS THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CROWN CASTLE. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC. 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. CONCRETE FOUNDATIONS AND REINFORCING STEEL: 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACT 336, ASTM A184, ASTM A185 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE. 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 psf. 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (Ve) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90'f AT TIME OF PLACEMENT. 4. CONCRETE EXPOSED TO FREEZE -THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR ENTRAINMENT TO BE BASED ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A MAXIMUM WATER -TO -CEMENT RATIO (W/C) OF 0.45. 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. ALL SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, UNLESS NOTED OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: #4 BARS AND SMALLER.................................................................................... 40 ksi #5 BARS AND LARGER. .................. - __ ................. ___ ...................... 60 ksi 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH....................._3" CONCRETE EXPOSED TO EARTH OR WEATHER: 6 BARS AND LARGER.....................................................................................2„ 5 BARS AND SMALLER..........................................................................1-1 2.. # / CONCRETE NOT EXPOSED TO .EARTH OR WEATHER: IF SLAB AND WALLS ........ .................................................................. .....3/4„ BEAMS AND COLUMN ...._ ....................._.... ...... .......... . _........... _......... 1-1/2" 7. A TOOLED EDGE OR A 3/4't CHAMFER SHALL BE PROVIDED AT�L EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 2. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. B. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. _ 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. _ 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES/ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S). 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. S. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW THWN TITI XHHW XHITI THW TITI RHW OR RITI INSULATION UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR TYPE SCOW CORD (#4 OR LARGER) UNLESS ) OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR TYPE TO CABLE 14 OR LARGER), ). WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75' C (90` C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT. 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE NEC. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i.e. POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION -TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR lkEXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WE OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "AT&T". 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. CONDUCTOR COLOR CODE SYSTEM CONDUCTOR COLOR 120/24OV, 10 A PHASE BLACK B PHASE RED NEUTRAL WHITE GROUND GREEN 120 208V 34 / A PHASE BLACK B PHASE RED C PHASE BLUE NEUTRAL WHITE GROUND GREEN 277/48OV, 30 A PHASE BROWN B PHASE ORANGE OR PURPLE C PHASE YELLOW NEUTRAL GREY GROUND GREEN DC VOLTAGE POS (+) ­ RED ** LEG (-) BLACK** * SEE NEC 210.5(C)(1) AND (2) ** POLARITY MARKED AT TERMINATION ABBREVIATIONS: ANT ANTENNA (E) EXISTING FIE FACILITY INTERFACE FRAME GEN GENERATOR GPS GLOBAL POSITIONING SYSTEM GSM OLBBAL SYSTEM FOR MOBILE LTE LONG TERM EVOLUTION MOB MASTER GROUND BAR MW MICROWAVE (N) NEW NEC NATIONAL ELECTRIC CODE (P) PROPOSED PP POWER PLANT QTY QUANTITY RECT RECTIFIER RBS RADIO BASE STATION BET REMOTE ELECTRIC TILT REDS RADIO FREQUENCY DATA SHEET RRH REMOTE RADIO HEAD RRU REMOTE RADIO UNIT SIAD SMART INTEGRATED DEVICE TMA TOWER MOUNTED AMPLIFIER TYP TYPICAL UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM W.P. WORK POINT APWA UNIFORM COLOR CODE: WHITE PROPOSED EXCAVATION ® TEMPORARY SURVEY MARKINGS ®ELECTRIC POWER LINES, CABLES, CONDUIT, AND LIGHTING CABLES YELLOW GAS OIL, STEAM, PETROLEUM, OR GASEOUS MATERIALS COMMUNICATION, ALARM OR SIGNAL LINES, CABLES, OR CONDUIT AND TRAFFIC LOOPS ® POTABLE WATER ®RECLAIMED WATER, IRRIGATION, AND SLURRY LINES ® SEWERS AND DRAIN LINES Planning Administrative Approval COPPELL 05/13/2021 AT&T 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 0 - CROWN CASTLE 1701 DIRECTORS BLVD, SUITE 700 AUSTIN, TX 78744 46 POD POWER OF DESIGN 11490 BLUEGRASS PKWY LOU ISVILLE, KY 40299 502-437-5252 AT&T SITE NUMBER: DXL00642 BU #: 843595 v TAP/SANDY 440 NORTH DENTON TAP COPPELL, TX 75019 EXISTING 80'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCF=ON DES./QA 0 02/26/21 NH CONSTRUCTION MEP ...t.............................t... .MARK E. PATTERSON ..t............... .....t... ,0 113892 /,:17 �SS/BNAL 02/26/2021 TEXAS FIRM NUMBER 16059 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFSSSIONAL ENGI SSK TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: T-2 0 T (I " THE (E) AT&T EQUIPMENT ROOM SITE PLAN SCALE. 1/2"=1'-0" (FULL SIZE) (�o 2' 1' 0 2' 1/4"-1-0" (11x17) Planning Administrative Approval COPPELL 05/13/2021 `I✓ AT&T 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CROWN v CASTLE 1701 DIRECTORS BLVD, SUITE 700 AUSTIN, TX 78744 POD POWER OF DESIGN 11490 BLUEGRASS PKWY LOUISVILLE, KY 40299 502-437-5252 AT&T SITE NUMBER: DXL00642 BU #: 843595 v TAP/SANDY 440 NORTH DENTON TAP COPPELL, TX 75019 EXISTING 80'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCF=ON DES./QA 0 02/26/21 NH CONSTRUCTION MEP E OF T .* .....:............................. �..... MARK E. PATTERSON ..%.... .....j... 0 113892 FSS/ONAL ECG 02/26/2021 TEXAS FIRM NUMBER 16059 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-1 0 J STRUCTURE W/ APPURTENANCE ELEV. = 81'-O" h HEIGHT OF STRUCTURE ELEV. = 80'-0" AT&T EQUIPMENT ANTENNA CL: 78'-0" MOUNT CL: 78'-0" TOWER & ANTENNA STANDARD NOTES: A. DIRECT TOWER MOUNTED EQUIPMENT MUST NOT TRAP OR INTERFERE W/ CLIMBING PEGS/STEPS AND SAFETY CLIMB. B. NEW EQUIPMENT CANNOT BE MOUNTED DIRECTLY TO TOWER. NEW EQUIPMENT MUST BE MOUNTED TO CUSTOMER MOUNT. C. CONTRACTOR TO VERIFY ALL ANTENNA TIP HEIGHTS DO NOT EXCEED BEACON BASE HEIGHT. D. VERIFY AZIMUTHS WITH REDS. E MOUNT & TOWER COMPLIANCE IS BY OTHERS. NO NEW ANTENNAS OR EQUIPMENT SHALL BE INSTALLED ON MOUNTS OR TOWER WITHOUT THE APPROVAL OF A PROFESSIONAL ENGINEER. F. PROPOSED ANTENNA PLACEMENT LOCATION TO BE FIELD VERIFIED BY GENERAL CONTRACTOR PRIOR TO CONSTRUCTION TO AVOID ANY INTERFERENCE OR SHADOWING OF EXISTING OR PROPOSED ANTENNAS. IF INTERFERENCE OR SHADOWING OF ANTENNAS IS DISCOVERED DURING FIELD VERIFICATION, PLEASE CONTACT A&E VENDOR FOR DESIGN REVISION PRIOR TO ANY NEW ANTENNA INSTALLATION. TOWER ELEVATION �J SCALE NOT TO SCALE 2/3 FOR AT&T FINAL A LAYOUT 0 78'-C" MCL ) 80'-0" MONOPOLE I AT&T FEEDLINES 3) COAX CABLES (7/8") DC CABLES (3/4") FIBER CABLES (3/8") INNERDUCT CONDUITS (2") W AT&T FEEDLINES DC CABLES (7/8") FIBER CABLE (3/8") INNERDUCT CONDUITS (2") (E) AT&T ANTENNA TO REMAIN COMMSCOPE - JAHH-65B-R3B-V3 (6 TOTAL, 2 PER SECTOR) (E) PLATFORM MOUNT TO REMAIN — EXISTING AT&T ACL h ELEV. = 78'-0" (E) AT&T RRH TO REMAIN — ERICSSON - RRUS 4478 B14 (3 TOTAL, 1 PER SECTOR) EXISTING AT&T ACL ELEV. = 63'-0" l (ALPHA) S' AZIMUTH (E) AT&T SQUID TO REMAIN RAYCAP - DC6-48-60-18-8C (1 TOTAL) (E) AT&T SQUID TO REMAIN RAYCAP - DC6-48-60-18-8F (2 TOTAL) (GAMMA) 248' AZIMUTH r INSTALLER NOTE: TOWER DOES NOT HAVE CLIMBING FACILITIES - MANLIFT REQUIRED FOR ELEVATED WORK. _ (E) AT&T RRH TO REMAIN ERICSSON - RRUS 32 B66A (3 TOTAL, 1 PER SECTOR) (E) AT&T ANTENNA COMMSCOPE - JAHH-65B-R3B-V3 (6 TOTAL, 2 PER SECTOR) (E) PLATFORM MOUNT (E) AT&T RRH ERICSSON - RRUS 4478 B14 (3 TOTAL, 1 PER SECTOR) (E) 80'-0" MONOPOLE (E) AT&T RRH TO REMAIN ERICSSON - RRUS 4478 B5 (3 TOTAL, 1 PER SECTOR) (E) AT&T RRH TO BE RELOCATED ERICSSON - RRUS 32 B30 (3 TOTAL, 1 PER SECTOR) (E) AT&T ANTENNA TO BE REMOVED QU I NTEL TECH - QS6658-3 (6 TOTAL, 2 PER SECTOR) (BETA) 128' AZIMUTH (E) AT&T RRH TO BE REMOVED FRICSSON - RRUS 11 B12 (3 TOTAL, 1 PER SECTOR) (E) AT&T RRH TO REMAIN ERICSSON - RRUS 4415 B25 (3 TOTAL, 1 PER SECTOR) EXISTING ANTENNA PLAN �JSCALE: NOT TO SCALE N (E) AT&T SQUID RAYCAP - DC6-48-60-18-8C (1 TOTAL) (E) AT&T SQUID RAYCAP - DC6-48-60-18-8F (2 TOTAL) NEW AT&T ANTENNA ERICSSON - AIR 6449 N77 (3 TOTAL, 1 PER SECTOR) NEW AT&T SQUID RAYCAP - DC6-48-60-18-8C-EV (GAMMA) (1 TOTAL) 22448° AZIMUTH (E) AT&T RRH ERICSSON - RRUS 32 B66A (3 TOTAL, 1 PER SECTOR) (E) AT&T RRH ERICSSON - RRUS 4415 B25 (3 TOTAL, 1 PER SECTOR) 80'-0" 1 (ALPHA) 8` AZIMUTH NEW AT&T ANTENNA COMMSCOPE - NNH4-65B-R6H4 (3 TOTAL, 1 PER SECTOR) NEW AT&T DIPLEXER COMMSCOPE - CBC78T-DS-43 (3 TOTAL, 1 PER SECTOR) NEW AT&T BACK TO BACK MOUNT COMMSCOPE - RR-FA2 (3 TOTAL, 1 PER SECTOR) (E) AT&T RRH FRICSSON - RRUS 4478 B5 (3 TOTAL, 1 PER SECTOR) NEW AT&T 2-1/2" SCH 40 (2-7/8" O.D.) BY 6'-0" LONG GALV. PIPE W/ CROSSOVER HARDWARE (1 TOTAL) NEW AT&T RRH ERICSSON - RRUS 4478 B12 (3 TOTAL, 1 PER SECTOR) (E) AT&T RRH RELOCATION ERICSSON - RRUS 32 830 (3 TOTAL, 1 PER SECTOR) TZ-� NEW ANTENNA PLAN '\,�SCALE: NOT TO SCALE N (BETA) 128' AZIMUTH Planning Administrative Approval COPPELL 05/13/2021 AT&T 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 - CROWN CASTLE 1701 DIRECTORS BLVD, SUITE 700 AUSTIN, TX 78744 `44 POD POWER OF DESIGN 11490 BLUEGRASS PKWY LOU ISVI LLE, KY 40299 502-437-5252 AT&T SITE NUMBER: DXL00642 BU #: 843595 v TAP/SANDY 440 NORTH DENTON TAP COPPELL, TX 75019 EXISTING 80'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 0 02/26/21 NH CONSTRUCTION MEP OF •MARK E. PATTERSON ..%............................ t... ,0 113892 ADNAL 02/26/2021 TEXAS FIRM NUMBER 16059 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-2 0 Planning Administrative Approval cOFFEL% NIA 05/13/2021 EQUIPMENT DESCRIPTION TABLE 1 SCALE: NOT TO SCALE \ / AT&T 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 TOWER TOP EQUIPMENT SCHEDULE (FINAL) ANTENNA SECTOR ANTENNA ELEVATION ANTENNA AZIMUTH CATEGORY PROPOSED CONFIGURATION OTY. a a a 78'-0" 8' ANTENNA (Al) JAHH-65B—R3B—V3 1 ANTENNA (A2) JAHH-65B-R3B-V3 1 ANTENNA (A3) AIR 6449 N77 1 CROWN 0 CASTLE 1701 DIRECTORS BLVD, SUITE 700 AUSTIN, TX 78744 ANTENNA (A5) NNH4-65B—R6H4 1 TOWER DIPLEXERS CBC78T—DS-43 1 RRHs RRUS 32 B30 1 RRUS 32 B66A 1 POD POWER OF DESIGN 11490 BLUEGRASS PKWY LOU ISVI LLE, KY 40299 502-437-5252 RRUS 4415 D25 1 RRUS 4478 B12 1 RRUS 4478 B14 1 RRUS 4478 35 1 AT&T SITE NUMBER: DXL00642 BU #: 843595 DENTON TAP/SANDY LAKE 440 NORTH DENTON TAP COPPELL, TX 75019 EXISTING 80'-0" MONOPOLE m 78'-0" 128' ANTENNA (131) JAHH-65B—R3B—V3 1 ANTENNA (132) JAHH-65B—R3B—V3 1 ANTENNA (B3) AIR 6449 N77 1 ANTENNA (B5) NNH4-65B—R6H4 1 TOWER DIPLEXERS CBC78T—DS-43 1 RRHs RRUS 32 B30 1 RRUS 32 B66A 1 RRUS 4415 B25 1 RRUS 4478 D12 1 ISSUED FOR: RRUS 4478 B14 1 REV DATE DRWN DESCRIPTION DES.ZQA RRUS 4478 35 1 0 02/26/21 NH CONSTRUCTION MEP 78'-0" 248' ANTENNA (C1) JAHH-65B—R3B—V3 1 ANTENNA (C2) JAHH-65B—R3B—V3 1 ANTENNA (C3) AIR 6449 N77 1 MARK E. PATTERSON .....t.............................t..... /113892 VICENS10),.f\�� SADNAL 02/26/2021 TEXAS FIRM NUMBER 16059 ANTENNA (C5) NNH4-65B—R6H4 1 TOWER DIPLEXERS CBC78T—DS-43 1 RRHs RRUS 32 B30 1 RRUS 32 B66A 1 RRUS 4415 B25 1 RRUS 4478 B12 1 RRUS 4478 B14 1 RRUS 4478 35 1 COAX/FIBER/DC 7/8" 20 3/4" 6 3/8" 3 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OP A LICENSED PROFSSSIONAL ENGI SSK TO ALTER THIS DOCUMENT. MISCELLANEOUS I DC6-48-60-18-8C 1 DC6-48-60-18-8C-EV 1 SHEET NUMBER: REVISION: 11 C-3-, 0 DC6-48-60-18-8F I 2 I --� SNAP -IN HANGER HANGER ADAPTER GROMMET DC/FIBER CABLE BUNDLE DOUBLE CLAMP INSTALLER NOTES: 1. COMPLY WITH MANUFACTURERS INSTRUCTIONS TO ENSURE THAT ALL RRHs RECEIVE ELECTRICAL POWER WITHIN 24 HOURS OF BEING REMOVED FROM THE MANUFACTURER'S PACKAGING. 2.DO NOT OPEN RRH PACKAGES IN THE RAIN. 3. ALL PIPES, BRACKETS, AND MISCELLANEOUS HARDWARE TO BE GALVANIZED UNLESS \ NOTED OTHERWISE. AT&T RRH AND HARDWARE SUPPLIED BY MANUFACTURER (TYP) HANGER AD, SNAP -IN MOUNTING BRACKET (SUPPLIED W/ ANTENNA) MOUNTING PIPE (TYP) ANTENNA MOUNTING PIPE COMMSCOPE - RR-FA2 AND HARDWARE (TYP) MOUNTING BRACKET (SUPPLIED W/ ANTENNA) �-,�ANTENNA WITH RRHs MOUNTING DETAIL �JSCALE: NOT TO SCALE CAB HANGER ADAPTER GROMN BUTTERFLY HANGER SNAP -IN HANGER HANGER ADAPTER GROMMET DETAILS SCALE: NOT TO SCALE NEW ANTENNA BUTTERFLY HANGER CABL HANGER ADAPTER GROMN CLIP -IN HANGER CLIP -IN HANGER Planning Administrative App-1 COPPELL .gym 05/13/2021 AT&T 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 0 - CROWN CASTLE 1701 DIRECTORS BLVD, SUITE 700 AUSTIN, TX 78744 �14 Po D- POWER OF DESIGN 11490 BLUEGRASS PKWY LOU ISVI LLE, KY 40299 502-437-5252 AT&T SITE NUMBER: DXL00642 BU #: 843595 v TAP/SANDY 440 NORTH DENTON TAP COPPELL, TX 75019 EXISTING 80'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRI7DON DES./QA 0 02/26/21 NH CONSTRUCTION MEP N MARK E. PATTERSON �....%............................ t.... ,0 113892 ��� S /CENSQ ..x V b - ONAL E� 02/26/2021 TEXAS FIRM NUMBER 16059 IT IS A VIOLATION OF LAW POR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-4 1 0 Ericsson 64Tx AIR 6449 B77D/ C-Band • Advanced Antenna System (AAS) • 64TX/64RX with 192 AE • Up to 320W RF Power • EIRP up to 79 dBm • Up to 200 MHz IBW&CBW • Max total carrier BW is 200MHz for NR • Support number of layers: DVUL 16/8 N0.6uaelaYGeaq xexp VM oatn vrepx pnn-1 uuimnt aal..t .o,�,ena.•. mimmt tiros mnt roan roam iiixaei • 4 x 25 Gbps eCPRI, (compatible to 10G) eCPRI SFP28 -48 VDC, max 1540 W • -40 to '55C,(Ind Solar Load) Typical power consumption <1130 W. NOTE: POWER OF DESIGN GROUP, NOR OUR ENGINEER IS RESPONSIBLE FOR DESIGN OR MANUFACTURE OF THE SPECS SHOWN ON THIS SHEET. PLEASE CONTACT THE MANUFACTURER FOR ANY QUESTIONS OR CONCERNS. /-�ANTENNA SPECIFICATIONS SCALE: NOT TO SCALE I DATA SHEET Rooftop / Towertop The DC6-48-60-18-8C-EV is designed to provide the ultimate coordination between the SPD and the RRH/RRU by offering industry -leading low -clamping voltage of 160V and extremely robust protection for use in a high DC voltage environment. Capable of providing 12.5kA (10/350 Ns) max per circuit surge capacity for Lip to 6 -48V DC circuits. DC Surge Protection Solutions DC6-48.60-18-8C-EV Overvoltage Protection and Fiber Distribution/Cable Management Solution tow 1 b, StrikesoW r— Features • Provides discrete protection for six individual -48V DC circuits • Surge protection of 90kA 8/20 ps • Maximum impulse current 12.5kA 10/350 ps • Fiber connections for up to 18 fiber pair • Simplifies inter -connectivity and cable management for DC conductors • UL 1449 4th Edition Type 2 protective device • IEC 61643-11 Class I protection for DC applications • Form C relay contacts included, allowing remote monitoring of suppressor status • Copper -coated lid to reduce power line interference • Patented design • Patented Strikesorb technology ensures lowest let -through voltage available in the industry, providing enhanced coordination with the RRH/RRU • Raycap recommends that DC protection system be installed within 5 meters of the radio Benefits • Strikesorb modules are fully recognized to UL 1449 4th Edition, and IEC 61643-11 Safety Standards, meeting all intermediate and high current fault requirements to facilitate use in original equipment manufacturers (OEM) applications • Strikesorb offers unique maintenance -free protection against direct lightning currents • Design provides maximum flexibility for installation • NEMA 4X enclosure allows for indoor or outdoor installation Raycap wwt4r.Mycap.com �SQUID SPECIFICATIONS �JSCALE. NOT TO SCALE Strikesorb is a registered trademark of Raycap Q 2018 Raycap All rights reserved. G02-01-203 180122 Planning Administrative Approval COPPELL 05/13/2021 AT&T 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CCCROWN CASTLE 1701 DIRECTORS BLVD, SUITE 700 AUSTIN, TX 78744 40POD POWER OF DESIGN 11490 BLUEGRASS PKWY LOUISVILLE, KY 40299 502-437-5252 AT&T SITE NUMBER: DXL00642 BU #: 843595 v TAP/SANDY 440 NORTH DENTON TAP COPPELL, TX 75019 EXISTING 80'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCF=ON DES./QA 0 02/26/21 NH CONSTRUCTION MEP PEE OF i....................'r.* •MARK E. PATTERSON ..%............................ �j... FSS/ONAL ECG 02/26/2021 TEXAS FIRM NUMBER 16059 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-5.11 0 1 � J NNH4-65B-R6H4 12-port sector antenna, 4x 698-896 and 8x 1695-2360 MHz, 65° HPBW, 6x RET. .us W` • i • a . _ General Specifications Antenna Type Band Effective Projective Area (EPA), frontal Effective Projective Area (EPA), lateral Grounding Type Performance Note Radome Material Radiator Material Reflector Material RF Connector Interface RF Connector Location RF Connector Quantity, high band RF Connector Quantity, low band RF Connector Quantity, total • Features broadband Low Band (698-896 MHz) and High Band (1695-2360 MHz) arrays for 4T4R (4X MIMO) capability for Band 14, AWS, PCS and WCS applications. • Non -stacked high band array design provides higher gain and narrower vertical beamwidth than traditional antenna designs. • Independent tilt for all arrays. • Array configuration provides capability for 4T4R (4x MIMO) on Low band and Dual 4T4R (4x MIMO) on High band • Optimized SPR performance across all operating bands • Excellent wind loading characteristics • Supports re -configurable antenna sharing capability enabling control of the internal RET system using up to two separate RET compatible OEM radios Sector Multiband 0.65 m2 1 6.997 ft2 0.22 m2 1 2.368 ft2 RF connector inner conductor and body grounded to reflector and mounting bracket Outdoor usage I Wind loading figures are validated by wind tunnel measurements described in white paper WP-112534-EN Fiberglass, LIV resistant Low loss circuit board Aluminum 4.3-10 Female Bottom 8 4 12 Remote Electrical Tilt (PET) Information, General RET Hardware Commil v2 RET Interface 8-pin DIN Female 18-pin DIN Male NOTE: POWER OF DESIGN GROUP, NOR OUR ENGINEER IS RESPONSIBLE FOR DESIGN OR MANUFACTURE OF THE SPECS SHOWN ON THIS SHEET. PLEASE CONTACT THE MANUFACTURER FOR ANY QUESTIONS OR CONCERNS. ��ANTENNA SPECIFICATIONS SCALE: NOT TO SCALE NNH4-65B-R6H4 RET Interface, quantity Dimensions Width Depth Len gth Array Layout MT WYIY2 JY3Y4 Left Right Bottom 2female 12male 498 mm 1 19.606 in 197 mm 1 7.756 in 1828 mm 1 71.969 in Hz) Conns IRET AISG RET UID 126 6 1-2 1 CPxxxxxxxxxbcxxrocmm.1 3-4 2 CPxxxxxxxxxxxxxxxmm.2 Y1 1695-2360 5-6 3 CPxxxxxxxxxxxxxxxmm.3 YZ 1695-2360 7-8 4 CPxxxxxxxxxxxxxxxmm.4 Y3 1695-2360 9-10 5 CPxxxxxxxxx)o=xxmm.5 Y4 1695-2360 11-12 6 CPxxxxxxxxxxxxxxxmm.6 (Sizes of colored boxes arc not true depictions of array sizes) Port Configuration Planning Administrative Approval COPPELL 05/13/2021 AT&T 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CROWN CASTLE 1701 DIRECTORS BLVD, SUITE 700 AUSTIN, TX 78744 `14 PO D POWER OF DESIGN 11490 BLUEGRASS PKWY LOU ISVI LLE, KY 40299 502-437-5252 AT&T SITE NUMBER: DXL00642 BU #: 843595 v TAP/SANDY 440 NORTH DENTON TAP COPPELL, TX 75019 EXISTING 80'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 0 02/26/21 NH CONSTRUCTION MEP OF r-qvt .�I MARK E. PATTERSON ....%............................ r.... a 113892 :/4�, ��� /ONAI- ��� 02/26/2021 TEXAS FIRM NUMBER 16059 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C - 5.2 0 CBC78T-DS-43 I E14F05P19 BRACKET a E, O E ® O E- 698.803 824-894 E 824.8N 15OR-=, 2X GND M6 X l.D 6X 4.9.10 CONNECTOR r VENTING MEMBRANE D O ♦A p—0 _ (, E = E £ 0 0 °_1 O 176mm� 16.9 N] Electrical Specifications Impedance 50 ohm License Band, Band Pass CEL 850 1 USA 700 1 USA 750 Electrical Specifications, Common Port Composite Power, RMS 250 W Electrical Specifications, do Power/Alarm do/AISG Pass -through Method Auto sensing do/AISG Pass -through Path See logic table Lightning Surge Current 10 kA Lightning Surge Current Waveform 8/20 waveform NOTE: POWER OF DESIGN GROUP, NOR OUR ENGINEER IS RESPONSIBLE FOR DESIGN OR MANUFACTURE OF THE SPECS SHOWN ON THIS SHEET. PLEASE CONTACT THE MANUFACTURER FOR ANY QUESTIONS OR CONCERNS. /-� DIPLEXER SPECIFICATIONS SCALE: NOT TO SCALE IJ:T.--inn. W RRUS 4478 CPR I 2 ports x 2.5/4.9/9.8/10.1 Gbps. Install 1 SFP and conned 1 fiber pair to the RRUS 4478 during initial install. Only use Ericsson supplied and approved SFPs RDH10265/25 > 2 external alarm inputs Max wind load @ 50m/sec = 26ON Breaker size = 25A, DC Power Consumption = 670 W (for dimensioning) 200mm horizontal separation required for side by side mounting > 200mm separation required from antenna backplane to radio 400mm vertical outdoor/indoor separation required between 2 radios 500mm vertical separation below antenna Min, Max DC cable size from squid to radio = 10,8 AWG - Adapter is required for 2-wire connection - Shielded DC cable is required Ground cable size = 2AWG > Dimensions (incl. handles, feet and sunshield, w/o fan unit) - Height: 16.5" (420 mm) - Width: 13.4" (340 mm) - Depth: 7.7" (196 mm) > Weight, excl. mounting hardware = 59.9lbs (27.2 kg) RRUS 32 Detaslleet fa Turf Vendors I Conmerclal in confidence I Re,A 1 2016-01-21 1 Page ,-� RRH SPECIFICATIONS �L SCALE: NOT TO SCALE i 4 3 i 2 NOTES O GEIEJUL +. NiN>:Twc ouersRra2aew asfiacsrs ,�mRR4TEa1Mm_„_rt _ 240EaGN NOTEa z+ 81aMTW4tEn 1E6swro. 05. V 60' ANaE D eo v�taF cn�iasx.5aECNlnEouwuExrs D ,c csT scvacw,caa ® 8 50 [215 9] c c A 18.00[457.2] p� o Ed 2 50[63 5] m.d4[11.1] TYP 13.56[344.5] (1641 [4168]) 3.0[75,21 2 44 [61 91 R28[7.1j TYP 4 PATENT PENDING 3 2 Z DUAL RRH MOUNT SPECIFICATIONS �JSCALE: NOT TO SCALE ,. a. Olt COPE, INC. OF NORTH CAROLINA ... o.a ERR-FA2 .r �+4i1r1medBa �. FASTACCESSDWLRRU MOUNT A =TT1:2� RR-FA2 Planning Administrative Approval COPP'EgLL 05/13/2021 AT&T 1801 VALLEY VIES' LANE FARAMRS BRANCH TX 75234 CCCROWN CASTLE 1701 DIRECTORS BLVD, SUITE 700 AUSTIN, TX 78744 POD POWER OF DESIGN 11490 BLUEGRASS PKWY LOUISVILLE, KY 40299 502-437-5252 AT&T SITE NUMBER: DXL00642 BU #: 843595 v TAP/SANDY 440 NORTH DENTON TAP COPPELL, TX 75019 EXISTING 80'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCF=ON DES./QA 0 02/26/21 NH CONSTRUCTION MEP 02/26/2021 TEXAS FIRM NUMBER 16059 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: G 5.3 0 TO ANTENNA COAX COPPER/GALVANIZED GROUND BAR o o o o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TWO HOLE LONG BARREL COMPRESSION LUG (TYR) NOTES: 1. DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED. 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO ANTENNA MOUNT STEEL. /--,---\ ANTENNA SECTOR GROUND BAR DETAIL SCALE: NOT TO SCALE TO TOWER MOUNTED EQUIPMENT ()4q TO ANTENNAMONOPOLE ANTENNA GROUND BAR LOCATED AT MCL (BONDED TO TOWER STEEL) STANDARD C2 HOLE LUG (TYP) CABLE GROUND(T#6 STRANDED CUWIRGREEN,600VINSULATION (OR AS PRWITH GROUND KIT MECHANICAL CONNECTION (TYR) COAX CABLE COAX GROUND BAR WITH INSULATORS, CONNECTED (TYP FOR ALL) \ DIRECTLY TO THE BOTTOM OF MONOPOLE. SEE NOTE 1. TO BITS EQUIPMENT VIA TRAY OR ICE BRIDGE TO ANTENNA COAX T/FINISH GRADE Ili//�— COPPER/GALVANIZED GROUND BAR o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 @ N_ w #2 SOLID TINNED COPPER o CONDUCTOR TO TOWER/SHELTER z o NJO HOLE LONG BARREL COMPRESSION LUG GROUND RING (2 TYR. FOR n (TYR) BOTTOM GROUND BAR ONLY) o NOTES: 1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). 3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. -\TOWER/SHELTER GROUND BAR DETAIL L SCALE: NOT TO SCALE STAINLESS STEEL BOLT (TYP) STAINLESS STEEL FLAT WASHER 2-HOLE CRIMP/ (TYP) COMPRESSION CONNECTOR GROUND BAR STAINLESS STEEL FLAT WASHER STAINLESS STEEL (TYR) BELLVILLE WASHER STAINLESS STEEL NUT (TYR) (TYR) SINGLE CONNECTOR AT GROUND BARS STAINLESS STEEL BOLT STAINLESS STEEL FLAT WASHER DRAGON TOOTH WASHER (TYR) STEEL 2/0 TINNED BARE I COPPER WIRE 2-HOLE CRIMP/ MONOPOLE PIER COMPRESSION CONNECTOR T GROUND WIRE SEE NOTE 3 GROUND WIRE NOTE 3 INSPECTION WELL EXOTHERMIC WELD (TYP) NOTES: 1. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATIONS AND CONNECTION ORIENTATION. COAXIAL CABLES EXCEEDING 200 FEET ON THE TOWER SHALL HAVE GROUND KITS AT THE MIDPOINT. PROVIDE AS REQUIRED. 2. ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE USA INC. TOWERS. ALL MECHANICAL CONNECTIONS SHALL BE TREATED WITH AN ANTI -OXIDANT COATING. 3. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE RECOGNIZED EDITION OF ANSI/TIA 222 AND NFPA 780. 4 TYPICAL ANTENNA CABLE GROUNDING SCALE : NOT TO SCALE STAINLESS STEEL FLAT WASHER (TYR) STAINLESS STEEL STAINLESS STEEL NUT BELLVILLE WASHER (TYR) (TYP) SINGLE CONNECTOR AT STEEL OBJECTS STAINLESS STEEL SELF -DRILLING STAINLESS STEEL METAL SCREW FLAT WASHER (TYR) (TYR) 2-HOLE CRIMP/ COMPRESSION CONNECTOR DRAGON TOOTH J METALLIC OBJECT WASHER (TYP) SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS HARDWARE DETAIL FOR EXTERIOR CONNECTIONS 5 SCALE: NOT TO SCALE 8" PVC PLUG 8" PVC PLUG CPLG. (THRD.) SUBGRADE #2 SOLID (TEST LOOP) NOTCH SIDES OF 8" PVC SCH 40 PIPE TO ALLOW EXIT/ENTRANCE OF EXOTHERMIC WELD GROUND RING WIRE TRENCH BOTTOM 2/0 TINNED CU EXTERNAL CADWELD TEST LOOP TO TOWER GROUND RING WIRE GROUND RING WIRE NOTES: 5/8" 0 x 10'-0" LONG COPPER CLAD GROUND ROD 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) (� INSPECTION WELL DETAIL `� SCALE: NOT TO SCALE 6" WIDE METALLIC HTEL GRADE WARNING/LOCATOR TAPE AT 12" DEPTH N 0 z c�oz EXOTHERMIC WELD 0 w GROUND RING #2 COPPER WIRE SOLID, TINNED FOR CARRIER AND ICE BRIDGE GROUND LOOP GROUND RING 2/0 FOR TOWER GROUND LOOP GROUND ROD COPPER CLAD STEEL ROD W/MIN. 5/8 0 x 10'-0" LONG NOTES: 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) GROUND ROD DETAIL 6 SCALE: NOT TO SCALE Planning Administrative Approval COPPEL 05/13/2021 AT&T 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 0 - CROWN CASTLE 1701 DIRECTORS BLVD, SUITE 700 AUSTIN, TX 78744 `441 POD - POWER OF DESIGN 11490 BLUEGRASS PKWY LOU ISVI LLE, KY 40299 502-437-5252 AT&T SITE NUMBER: DXL00642 BU #: 843595 v TAP/SANDY 440 NORTH DENTON TAP COPPELL, TX 75019 EXISTING 80'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 0 02/26/21 NH CONSTRUCTION MEP 02/26/2021 TEXAS FIRM NUMBER 16059 IT IS A VIOLATION OF LAW POR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: G-1 0 WEATHERPROOFING KIT (SEE NOTE 3) ANTENNA CABLE _ I_. TYPE 2—YA-2 TYPE XA TYPE YA-2 TYPE GY TYPE W TYPE VN TYPE NC TYPE SS TYPE GR WIRE SIZE BURNDY LUG BOLT SIZE #6 AWG GREEN INSULATED YA6C-2TC38 3/8" - 16 NC S 2 BOLT #2 AWG SOLID TINNED YA3C-2TC38 3/8" - 16 NC S 2 BOLT #2 AWG STRANDED YA2C-2TC38 3/8" - 16 NC S 2 BOLT #2/0 AWG STRANDED YA26-2TC38 3/8" - 16 NC S 2 BOLT #4/0 AWG STRANDED YA28-2N BURNDY GROUND LUG W/ LONG BARREL (SEE CHART) 1/2" — 16 NC S 2 BOLT NUT (TYP) LOCK WA*BARBOLT TYPE VS TYPE VB TYPE PT TYPE GT' NOTE: GROUN1. ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. (TYR) 2. MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD. BURNDY TWO HOLE LUG W/ LONG BARREL (SEE CHART) CADWELD GROUNDING CONNECTIONS SCALE: NOT NO-OX TO SCALE BARE WIRE TO BE AT BOTH ENDS (TYPICALLY) 12' TO 24„ 120" MAX. 1 #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR). SEE NOTE 1 & 2 d N � CABLE GROUND KIT CABLE CONNECTOR NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. CABLE GROUND KIT CONNECTION 3 SCALE: NOT TO SCALE 3/8-11x1" TAMPER RESISTANT BOLT (TYR) INSULATORS SEE NOTE 2. (TYP) TO ANTENNAS COAX JUMPER (TYP.) CONNEC WEATHERPROOFING (TYP. SEE NOTE ANTENNA CA TO BITS EQUIPMENT (7 HEAT SHRINK (CLEAR) GROUNDING CONDUCTOR STRANDED (GREEN INSULATED) ONLY FOR #6 AWG (SEE CHART) WEATHERPROOFING KIT (TYR) NOTES: GROUND KIT 1. ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. (TYR) ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. y6 AWG /---'\ MECHANICAL LUG CONNECTION COPPER/GALVANIZED SCALE: NOT TO SCALE COAX GROUND BAR BONDED DIRECTLY TOWER NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. 2. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE USED. /---\GROUND CABLE CONNECTION Q SCALE: NOT TO SCALE 00 WALL BRACKET 0 (TYP) ® 0 NOTE: MINIMUM OF S/S NUT ® 0 3 THREADS TO BE (TYR) VISIBLE ® ® ® ® (TYR) 0 0 S/S SPLIT ® 2 HOLE LONG WASHER ® 0 BARREL TINNED (TYR) ® UNIVERSAL COPPER SOLID COPPER ® GROUND BAR (4"x20") LUG S/S FLAT LOCK WASHER (TYP) WASHER P/N M10 (TYP) (TYP) TWO -HOLE COMPRESSION LUG TIN COATED SOLID NOTES: COPPER BUS BAR S/S FLAT WASHER 1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE CHERRY INSULATOR (TYR) USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY QAS-STD-10091. NO INSTALLED IF REQUIRED MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, S/S BOLT CAD -WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. (TYR) 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. GROUND BAR DETAIL � SCALE: NOT TO SCALE T,, LUG DETAIL �JSCALE: NOT TO SCALE #6 AWG MIN. FROM ANTENNA CABLE GROUND KIT GROUND BAR ON SHELTER. BRIDGE, OR ON ANTENNA TON *TWO HOLE LUG, OR EXOTHERMIC WELD TO BE USED WITH #2 AWG BARE CONDUCTOR WIRE TO BUILDING SERVICE GROUND OR GROUND RING ,,.� GROUNDWIRE INSTALLATION �SCALE: NOT TO SCALE #2 TINNED SOLID IN 3/4" LIQUID TIGHT CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION POINT. EXPOSED END OF THE LIQUID TIGHT CONDUIT MUST BE SEALED WITH SILICONE CAULK. CADWELD (TYP) TIE INTO EXISTING GROUND RII /'�_TRANSITIONING GROUND DETAIL SCALE: NOT TO SCALE PE GROUNDING SHALL BE ELIMINATED WHEN GROUND BAR IS ELECTRICALLY BONDED TO METAL TOWER Planning Adminisi,Mi Approval COPi'LLI, 05/13/2021 v AT&T V 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 - CROWN CASTLE 1701 DIRECTORS BLVD, SUITE 700 AUSTIN, TX 78744 POD POWER OF DESIGN 11490 BLUEGRASS PKWY LOU ISVI LLE, KY 40299 502-437-5252 AT&T SITE NUMBER: DXL00642 BU #: 843595 v TAP/SANDY 440 NORTH DENTON TAP COPPELL, TX 75019 EXISTING 80'-0" MONOPOLE ISSUED FOR: REV DATE DRWN DESCF=ON DES./QA 0 02/26/21 NH CONSTRUCTION MEP MARK E. PATTERSON t............................. I.... a 113892 FSS/ONAL E�� 02/26/2021 TEXAS FIRM NUMBER 16059 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: G-2 1 0