BXL00642_843595_DENTON_TAP_SANDY_LAKE_AT&T_PRIORITY_FCD_REV_0_02.26.2021_ss_v1.ADM_APPAT&T
AT&T SITE NUMBER: DXL00642 BUSINESS UNIT #:
AT&T SITE NAME: DENTON TAP/SANDY LAKE SITE ADDRESS:
AT&T FA CODE: 10077742 COUNTY:
AT&T PACE NUMBER: MRNTX069637 TOWER HEIGHT:
SITE TYPE: MONOPOLE
SITE INFORMATION
CROWN CASTLE USA INC.
DENTON TAP/SANDY LAKE
SITE NAME:
SITE ADDRESS:
440 NORTH DENTON TAP
COPPELL, TX 75019
COUNTY:
DALLAS
MAP/PARCEL #:
NOT AVAILABLE
AREA OF CONSTRUCTION:
EXISTING
LATITUDE:
32° 58' 48.81"
LONGITUDE:
-96o 59' 33.07"
LAT/LONG TYPE:
NAD83
GROUND ELEVATION:
469 FT.
CURRENT ZONING:
M
JURISDICTION:
CITY OF COPPELL
OCCUPANCY CLASSIFICATION:
U
TYPE OF CONSTRUCTION:
IIB
A.D.A. COMPLIANCE:
FACILITY IS UNMANNED AND NOT FOR
HUMAN HABITATION
PROPERTY OWNER
NOT AVAILABLE
TOWER OWNER--
CARRIER/APPLICANT:
ELECTRIC PROVIDER:
TELCO PROVIDER:
CROWN CASTLE USA INC.
2000 CORPORATE DRIVE
CANONSBURG, PA 15317
AT&T TOWER ASSET GROUP
1801 VALLEY VIEW LANE
FARMERS BRANCH, TX 75234
ONCOR
(888) 313-6862
NOT AVAILABLE
PROJECT TEAM
A&E FIRM:
POD
11490 BLUEGRASS PARKWAY
LOUISVIL.LE, KY 40299
(502) 437-5252
CROWN CASTLE
1701 DIRECTORS BLVD, SUITE 700
USA INC. DISTRICT
AUSTIN, TX 78744
CONTACTS:
BARCLAY HAWLEY - PROJECT MANAGER
JOE MCCALL - CONSTRUCTION MANAGER
JOSEPH OLSEN - A&E SPECIALIST
J OSEPH.OLSEN@CRO WNCASTLE. COM
(763) 852-0573
PROJECT: AT&T PRIORITY
DRAWING INDEX
SHEET #
SHEET DESCRIPTION
T-1
TITLE SHEET
T-2
GENERAL NOTES
C-1
SITE PLAN
C-2
TOWER ELEVATION & ANTENNA PLANS
C-3
EQUIPMENT DESCRIPTION TABLE
C-4
DETAILS
C-5.1
EQUIPMENT SPECS
C-5.2
EQUIPMENT SPECS
C-5.3
EQUIPMENT SPECS
G-1
GROUNDING SCHEMATIC
G-2
GROUNDING DETAILS
ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11X17.
CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING
DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL
IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY
DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE
RESPONSIBLE FOR SAME.
PROJECT DESCRIPTION
THE PURPOSE OF THIS PROJECT IS TO PROPOSE AN ANTENNA
MODIFICATION ON AN EXISTING WIRELESS SITE.
FINAL TOWER CONFIGURATION:
• (12) ANTENNAS
• (1) MW DISH
• (1) ODU
• (15) RRHs
• (3) DIPLEXERS
• (4) SQUIDS
• (18) COAX CABLES (7/8'�
• (2) COAX CABLES (3/8'�
• (6) DC CABLES (3/4'�
• (2) DC CABLES (7/8'�
• (1) FIBER CABLE (1/8'�
• (3) FIBER CABLES (3/8'�
• (4) INNERDUCT CONDUITS (2")
FINAL GROUND CONFIGURATION:
• NO CHANGES
DESIGN PACKAGE BASED ON THE APPLICATION
ID:541534
REVISION: 0
LOCATION MAP
a
0 4> rrar
•:ev Ur o
C
O - n o
c
E r o („ ON rr0,r Cry k
° W Parkway Blvd
9
v �A Andy Brown Park West 32.980225,
-96.992523
ejL
o•
843595
440 NORTH DENTON TAP
COPPELL, TX 75019
DALLAS
80'-011
Cottonwood Branch
Coy v
� o
r °owOodgranch Walgreens v Z Cross Ti be,s Tra11
�
,ae sac
Buddy Echols
Field
DRIVING DIRECTIONS FROM DFW INTERNATIONAL AIRPORT (2400 AVIATION DR, DFW AIRPORT, TX 75261)
1. FOLLOW INTERNATIONAL PKWY TO TX-121 IN COPPELL. TAKE THE TX-121 N EXIT FROM TX-121 N.
2. CONTINUE ONTO TX-121.
3. TURN RIGHT ONTO N DENTON TAP RD.
4. TURN LEFT.
APPLICABLE CODES
ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN
ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES
AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN
THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING
TO THESE CODES:
CODE TYPE CODE
BUILDING 2015IBC
MECHANICAL 2015IMC
ELECTRICAL 2014 NEC
INSTALLER NOTE:
TOWER DOES NOT HAVE CLIMBING
FACILITIES — MANLI FT REQUIRED FOR
ELEVATED WORK.
NOTE:
PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE
CROWN NOC AT (800) 788-701 1& CROWN CONSTRUCTION MANAGER
The Core r..
n v Andy Brown Park East 4
$d r
QatK�a��NNd �
L�
CFestn"t
Alex D,
Beechwoo
NO SCALE
REFERENCE DOCUMENTS:
STRUCTURAL ANALYSIS:
B+T GROUP
DATED:
FEBRUARY 25, 2021
MOUNT ANALYSIS:
INFINIGY ENGINEERING, PLLC
DATED:
FEBRUARY 16, 2021
Planning Administrative
Approval
COPPELL
s
,(„I `r __6511-e2
05/13/2021
® CALL TEXAS ONE CALL o
(L3 DIGINGD
CALL 3 WORKING DAYS
BEFORE YOU DIGI
AT&T
1801 VALLEY VIEW LANE
FARMERS BRANCH TX 75234
0 CROWN
CASTLE
1701 DIRECTORS BLVD, SUITE 700
AUSTIN, TX 78744
44
�
POD
I
POWER OF DESIGN
11490 BLUEGRASS PKWY
LOU ISVI LLE, KY 40299
502-437-5252
AT&T SITE NUMBER:
DXL00642
BU #: 843595
v TAP/SANDY
440 NORTH DENTON TAP
COPPELL, TX 75019
EXISTING 80'-0" MONOPOLE
ISSUED FOR:
REV
DATE
DRWN
DESCRI7DON
DES./QA
0
02/26/21
NH
CONSTRUCTION
MEP
OF
� 1
............:......'r.*
MARK E. PATTERSON
,....1..... .....I....
l,0%. 113892 :'�,
FiS�ONAL E��
02/26/2021
TEXAS FIRM NUMBER 16059
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET NUMBER:
REVISION:
T-1
1 0
CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS:
GENERAL NOTES:
ELECTRICAL INSTALLATION NOTES:
1. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE
TO PROCEED (NTP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE
SITE YOU MUST CONTACT THE CROWN CASTLE USA INC. NOC AT 800-788-7011 & THE CROWN CASTLE
USA INC. CONSTRUCTION MANAGER.
2. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT:
THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE
CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT
REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR
FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE
STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF
THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH
MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS
INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT
AND REPORTED TO YOUR CROWN CASTLE USA INC. POO OR CALL THE NOC TO GENERATE A SAFETY CLIMB
MAINTENANCE AND CONTRACTOR NOTICE TICKET.
3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED.
THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE,
ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL
REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL
REQUIREMENTS.
4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING
PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL
CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET
ANSI ASSE A10.48 LATEST EDITION ; FEDERAL STATE AND LOCAL REGULATIONS: AND ANY APPLICABLE
/ ( ).
INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL
RIGGING PLANS SHALL ADHERE TO ANSI ASSE A10.48 ( LATEST EDITION AND CROWN CASTLE USA INC.
STANDARD CED-STD-10253, INCLUDING THE REQUIREDINVOLVEMENT OF A QUALIFIED ENGINEER FOR
CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322
(LATEST EDITION).
5. ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION
ACTIVITIES ON CROWN CASTLE USA INC. TOWER SITE," CED-STD-10294 "STANDARD FOR INSTALLATION OF
MOUNTS AND APPURTENANCES," AND LATEST VERSION OF ANSI/TIA-1019-A-2012 "STANDARD FOR
INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS."
6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR
SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO
PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION.
7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE
CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND
COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC
AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH
ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES,
ORDINANCES AND APPLICABLE REGULATIONS.
8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE.
9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION.
10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE
WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE
WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE
CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL
PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL
PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E)
CONSTRUCTION SAFETY PROCEDURES.
11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT
SPECIFICATIONS, LATEST APPROVED REVISION.
12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT
THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER
REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY.
13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE
EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED
AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL
OF CONTRACTOR, TOWER OWNER, CROWN CASTLE USA INC., AND/OR LOCAL UTILITIES.
14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR
SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF
EQUIPMENT, ROOMS, AND SHELTERS.
15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT
AND TOWER AREAS.
16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED
SURFACE APPLICATION.
17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER,
EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT
EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS.
18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL
MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES
FOR EROSION AND SEDIMENT CONTROL.
19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND
STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION
OF OWNER.
20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL
CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE
RETURNED TO THE OWNER'S DESIGNATED LOCATION.
21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED
FROM SITE ON A DAILY BASIS.
22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW
OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT.
GREENFIELD GROUNDING NOTES:
1. FOR THE PURPOSE OF CONSTRUCTION DRAWING THE FOLLOWING DEFINITIONS SHALL APPLY:
CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION
CARRIER: AT&T
TOWER OWNER: CROWN CASTLE USA INC.
2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY
EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS
ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE
WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY
ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN
ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR
MISCELLANEOUS WORK NOT EXPLICITLY SHOWN.
3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF
CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS,
TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR
PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED
TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE
INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY.
4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL
DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT,
AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS,
GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER
CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD.
S. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO
ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY
OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE
CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS.
IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE
ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE.
6. PRIOR TO THE SUBMISSION OF BIDS THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE
EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION
DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CROWN CASTLE.
7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES,
REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS,
ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE
OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY
SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS.
8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND
LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.
9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE.
10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL
PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING
WITH ANY SUCH CHANGE OF INSTALLATION.
11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR
POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN
DRAWINGS.
12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY
DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC.
13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND
OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S
DESIGNATED LOCATION.
14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON
A DAILY BASIS.
CONCRETE FOUNDATIONS AND REINFORCING STEEL:
1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACT 336, ASTM A184, ASTM A185 AND
THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE.
2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED
TO BE 1000 psf.
3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (Ve) OF 3000 psi AT 28 DAYS, UNLESS NOTED
OTHERWISE. NO MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS
APPROVED BY THE ENGINEER OF RECORD. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90'f AT TIME OF
PLACEMENT.
4. CONCRETE EXPOSED TO FREEZE -THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR
ENTRAINMENT TO BE BASED ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE
TYPE II PORTLAND CEMENT WITH A MAXIMUM WATER -TO -CEMENT RATIO (W/C) OF 0.45.
5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM
A185. ALL SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE
STANDARD 90 DEGREE HOOKS, UNLESS NOTED OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE
AS FOLLOWS:
#4 BARS AND SMALLER.................................................................................... 40 ksi
#5 BARS AND LARGER. .................. - __ ................. ___ ...................... 60 ksi
6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE
ON DRAWINGS:
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH....................._3"
CONCRETE EXPOSED TO EARTH OR WEATHER:
6 BARS AND LARGER.....................................................................................2„
5 BARS AND SMALLER..........................................................................1-1 2..
# / CONCRETE NOT EXPOSED TO .EARTH OR WEATHER: IF
SLAB AND WALLS ........ .................................................................. .....3/4„
BEAMS AND COLUMN ...._ ....................._.... ...... .......... . _........... _......... 1-1/2"
7. A TOOLED EDGE OR A 3/4't CHAMFER SHALL BE PROVIDED AT�L EXPOSED EDGES OF CONCRETE, UNLESS NOTED
OTHERWISE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4.
1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN
ACCORDANCE WITH THE NEC.
2. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND
ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS.
3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE
TESTING RESULTS.
4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT
CLAMPS.
5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED
WITH THE POWER CIRCUITS TO BTS EQUIPMENT.
6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED
COPPER FOR OUTDOOR BTS.
7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED.
B. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED.
9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS.
10. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. _
11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. _
12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS.
13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS.
14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR.
15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS.
16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL.
17. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC.
18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR.
19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS,
METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE
USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT.
20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION
POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL).
21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO
THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS,
LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY).
1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE
FEDERAL, STATE, AND LOCAL CODES/ORDINANCES.
2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED
AND TRIP HAZARDS ARE ELIMINATED.
3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC.
4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC.
4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO
REQUIREMENT OF THE NATIONAL ELECTRICAL CODE.
4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT
CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES
NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT
ADOPTED CODE PRE THE GOVERNING JURISDICTION.
5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE
LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV
PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA.
6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE
CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND
CIRCUIT ID'S).
7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS.
S. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES.
9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER)
WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED.
10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH
TYPE THHW THWN TITI XHHW XHITI THW TITI RHW OR RITI INSULATION UNLESS OTHERWISE SPECIFIED.
11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR TYPE SCOW CORD (#4 OR LARGER) UNLESS
)
OTHERWISE SPECIFIED.
12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR TYPE TO CABLE 14 OR LARGER), ). WITH
TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED.
13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND
BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75' C (90` C IF AVAILABLE).
14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE
AND NEC.
15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR
EXPOSED INDOOR LOCATIONS.
16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS.
17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE
GRADE PVC CONDUIT.
18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION
OCCURS OR FLEXIBILITY IS NEEDED.
19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET
SCREW FITTINGS ARE NOT ACCEPTABLE.
20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND
THE NEC.
21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS
(WIREMOLD SPECMATE WIREWAY).
22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL).
23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE
DEVICES (i.e. POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE
LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES
IN DIRECTION -TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN
A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT
SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO
PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED
MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE.
24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET
STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR
BETTER) FOR EXTERIOR LOCATIONS.
25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR
lkEXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED
(WE OR BETTER) FOR EXTERIOR LOCATIONS.
26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED
NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS.
27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC.
BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS.
28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE
WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY.
29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "AT&T".
30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED.
CONDUCTOR COLOR CODE
SYSTEM
CONDUCTOR
COLOR
120/24OV, 10
A PHASE
BLACK
B PHASE
RED
NEUTRAL
WHITE
GROUND
GREEN
120 208V 34
/
A PHASE
BLACK
B PHASE
RED
C PHASE
BLUE
NEUTRAL
WHITE
GROUND
GREEN
277/48OV, 30
A PHASE
BROWN
B PHASE
ORANGE OR PURPLE
C PHASE
YELLOW
NEUTRAL
GREY
GROUND
GREEN
DC VOLTAGE
POS (+)
RED **
LEG (-)
BLACK**
* SEE NEC 210.5(C)(1) AND (2)
** POLARITY MARKED AT TERMINATION
ABBREVIATIONS:
ANT ANTENNA
(E) EXISTING
FIE FACILITY INTERFACE FRAME
GEN GENERATOR
GPS GLOBAL POSITIONING SYSTEM
GSM OLBBAL SYSTEM FOR MOBILE
LTE LONG TERM EVOLUTION
MOB MASTER GROUND BAR
MW MICROWAVE
(N) NEW
NEC NATIONAL ELECTRIC CODE
(P) PROPOSED
PP POWER PLANT
QTY QUANTITY
RECT RECTIFIER
RBS RADIO BASE STATION
BET REMOTE ELECTRIC TILT
REDS RADIO FREQUENCY DATA SHEET
RRH REMOTE RADIO HEAD
RRU REMOTE RADIO UNIT
SIAD SMART INTEGRATED DEVICE
TMA TOWER MOUNTED AMPLIFIER
TYP TYPICAL
UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM
W.P. WORK POINT
APWA UNIFORM COLOR CODE:
WHITE PROPOSED EXCAVATION
® TEMPORARY SURVEY MARKINGS
®ELECTRIC POWER LINES, CABLES, CONDUIT, AND LIGHTING CABLES
YELLOW GAS OIL, STEAM, PETROLEUM, OR
GASEOUS MATERIALS
COMMUNICATION, ALARM OR SIGNAL LINES,
CABLES, OR CONDUIT AND TRAFFIC LOOPS
® POTABLE WATER
®RECLAIMED WATER, IRRIGATION, AND
SLURRY LINES
® SEWERS AND DRAIN LINES
Planning Administrative
Approval
COPPELL
05/13/2021
AT&T
1801 VALLEY VIEW LANE
FARMERS BRANCH TX 75234
0 - CROWN
CASTLE
1701 DIRECTORS BLVD, SUITE 700
AUSTIN, TX 78744
46 POD
POWER OF DESIGN
11490 BLUEGRASS PKWY
LOU ISVILLE, KY 40299
502-437-5252
AT&T SITE NUMBER:
DXL00642
BU #: 843595
v TAP/SANDY
440 NORTH DENTON TAP
COPPELL, TX 75019
EXISTING 80'-0" MONOPOLE
ISSUED FOR:
REV DATE DRWN DESCF=ON DES./QA
0 02/26/21 NH CONSTRUCTION MEP
...t.............................t...
.MARK E. PATTERSON
..t...............
.....t...
,0 113892 /,:17
�SS/BNAL
02/26/2021
TEXAS FIRM NUMBER 16059
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFSSSIONAL ENGI SSK
TO ALTER THIS DOCUMENT.
SHEET NUMBER:
REVISION:
T-2
0
T (I
"
THE (E) AT&T EQUIPMENT ROOM
SITE PLAN
SCALE. 1/2"=1'-0" (FULL SIZE) (�o
2' 1' 0 2' 1/4"-1-0" (11x17)
Planning Administrative
Approval
COPPELL
05/13/2021
`I✓
AT&T
1801 VALLEY VIEW LANE
FARMERS BRANCH TX 75234
CROWN
v CASTLE
1701 DIRECTORS BLVD, SUITE 700
AUSTIN, TX 78744
POD
POWER OF DESIGN
11490 BLUEGRASS PKWY
LOUISVILLE, KY 40299
502-437-5252
AT&T SITE NUMBER:
DXL00642
BU #: 843595
v TAP/SANDY
440 NORTH DENTON TAP
COPPELL, TX 75019
EXISTING 80'-0" MONOPOLE
ISSUED FOR:
REV
DATE
DRWN
DESCF=ON
DES./QA
0
02/26/21
NH
CONSTRUCTION
MEP
E OF T
.*
.....:............................. �.....
MARK E. PATTERSON
..%.... .....j...
0 113892
FSS/ONAL ECG
02/26/2021
TEXAS FIRM NUMBER 16059
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET NUMBER:
REVISION:
C-1
0
J
STRUCTURE W/ APPURTENANCE
ELEV. = 81'-O"
h HEIGHT OF STRUCTURE
ELEV. = 80'-0"
AT&T EQUIPMENT
ANTENNA CL: 78'-0"
MOUNT CL: 78'-0"
TOWER & ANTENNA STANDARD NOTES:
A. DIRECT TOWER MOUNTED EQUIPMENT MUST NOT TRAP
OR INTERFERE W/ CLIMBING PEGS/STEPS AND SAFETY
CLIMB.
B. NEW EQUIPMENT CANNOT BE MOUNTED DIRECTLY TO
TOWER. NEW EQUIPMENT MUST BE MOUNTED TO
CUSTOMER MOUNT.
C. CONTRACTOR TO VERIFY ALL ANTENNA TIP HEIGHTS DO
NOT EXCEED BEACON BASE HEIGHT.
D. VERIFY AZIMUTHS WITH REDS.
E MOUNT & TOWER COMPLIANCE IS BY OTHERS. NO
NEW ANTENNAS OR EQUIPMENT SHALL BE INSTALLED
ON MOUNTS OR TOWER WITHOUT THE APPROVAL OF A
PROFESSIONAL ENGINEER.
F. PROPOSED ANTENNA PLACEMENT LOCATION TO BE
FIELD VERIFIED BY GENERAL CONTRACTOR PRIOR TO
CONSTRUCTION TO AVOID ANY INTERFERENCE OR
SHADOWING OF EXISTING OR PROPOSED ANTENNAS. IF
INTERFERENCE OR SHADOWING OF ANTENNAS IS
DISCOVERED DURING FIELD VERIFICATION, PLEASE
CONTACT A&E VENDOR FOR DESIGN REVISION PRIOR
TO ANY NEW ANTENNA INSTALLATION.
TOWER ELEVATION
�J SCALE NOT TO SCALE
2/3 FOR AT&T FINAL
A LAYOUT 0 78'-C" MCL
) 80'-0" MONOPOLE
I AT&T FEEDLINES
3) COAX CABLES (7/8")
DC CABLES (3/4")
FIBER CABLES (3/8")
INNERDUCT CONDUITS (2")
W AT&T FEEDLINES
DC CABLES (7/8")
FIBER CABLE (3/8")
INNERDUCT CONDUITS (2")
(E) AT&T ANTENNA TO REMAIN
COMMSCOPE - JAHH-65B-R3B-V3
(6 TOTAL, 2 PER SECTOR)
(E) PLATFORM MOUNT TO REMAIN —
EXISTING AT&T ACL h
ELEV. = 78'-0" (E) AT&T RRH TO REMAIN —
ERICSSON - RRUS 4478 B14
(3 TOTAL, 1 PER SECTOR)
EXISTING AT&T ACL
ELEV. = 63'-0"
l
(ALPHA)
S' AZIMUTH
(E) AT&T SQUID TO REMAIN
RAYCAP - DC6-48-60-18-8C
(1 TOTAL)
(E) AT&T SQUID TO REMAIN
RAYCAP - DC6-48-60-18-8F
(2 TOTAL)
(GAMMA)
248' AZIMUTH
r
INSTALLER NOTE:
TOWER DOES NOT HAVE CLIMBING
FACILITIES - MANLIFT REQUIRED FOR
ELEVATED WORK. _
(E) AT&T RRH TO REMAIN
ERICSSON - RRUS 32 B66A
(3 TOTAL, 1 PER SECTOR)
(E) AT&T ANTENNA
COMMSCOPE - JAHH-65B-R3B-V3
(6 TOTAL, 2 PER SECTOR)
(E) PLATFORM MOUNT
(E) AT&T RRH
ERICSSON - RRUS 4478 B14
(3 TOTAL, 1 PER SECTOR)
(E) 80'-0"
MONOPOLE
(E) AT&T RRH TO REMAIN
ERICSSON - RRUS 4478 B5
(3 TOTAL, 1 PER SECTOR)
(E) AT&T RRH TO BE RELOCATED
ERICSSON - RRUS 32 B30
(3 TOTAL, 1 PER SECTOR)
(E) AT&T ANTENNA TO BE REMOVED
QU I NTEL TECH - QS6658-3
(6 TOTAL, 2 PER SECTOR)
(BETA)
128' AZIMUTH
(E) AT&T RRH TO BE REMOVED
FRICSSON - RRUS 11 B12
(3 TOTAL, 1 PER SECTOR)
(E) AT&T RRH TO REMAIN
ERICSSON - RRUS 4415 B25
(3 TOTAL, 1 PER SECTOR)
EXISTING ANTENNA PLAN
�JSCALE: NOT TO SCALE N
(E) AT&T SQUID
RAYCAP - DC6-48-60-18-8C
(1 TOTAL)
(E) AT&T SQUID
RAYCAP - DC6-48-60-18-8F
(2 TOTAL)
NEW AT&T ANTENNA
ERICSSON - AIR 6449 N77
(3 TOTAL, 1 PER SECTOR)
NEW AT&T SQUID
RAYCAP - DC6-48-60-18-8C-EV
(GAMMA) (1 TOTAL)
22448° AZIMUTH
(E) AT&T RRH
ERICSSON - RRUS 32 B66A
(3 TOTAL, 1 PER SECTOR)
(E) AT&T RRH
ERICSSON - RRUS 4415 B25
(3 TOTAL, 1 PER SECTOR)
80'-0"
1
(ALPHA)
8` AZIMUTH
NEW AT&T ANTENNA
COMMSCOPE - NNH4-65B-R6H4
(3 TOTAL, 1 PER SECTOR)
NEW AT&T DIPLEXER
COMMSCOPE - CBC78T-DS-43
(3 TOTAL, 1 PER SECTOR)
NEW AT&T BACK TO BACK MOUNT
COMMSCOPE - RR-FA2
(3 TOTAL, 1 PER SECTOR)
(E) AT&T RRH
FRICSSON - RRUS 4478 B5
(3 TOTAL, 1 PER SECTOR)
NEW AT&T 2-1/2" SCH 40 (2-7/8" O.D.) BY
6'-0" LONG GALV. PIPE W/ CROSSOVER
HARDWARE
(1 TOTAL)
NEW AT&T RRH
ERICSSON - RRUS 4478 B12
(3 TOTAL, 1 PER SECTOR)
(E) AT&T RRH RELOCATION
ERICSSON - RRUS 32 830
(3 TOTAL, 1 PER SECTOR)
TZ-� NEW ANTENNA PLAN
'\,�SCALE: NOT TO SCALE
N
(BETA)
128' AZIMUTH
Planning Administrative
Approval
COPPELL
05/13/2021
AT&T
1801 VALLEY VIEW LANE
FARMERS BRANCH TX 75234
- CROWN
CASTLE
1701 DIRECTORS BLVD, SUITE 700
AUSTIN, TX 78744
`44 POD
POWER OF DESIGN
11490 BLUEGRASS PKWY
LOU ISVI LLE, KY 40299
502-437-5252
AT&T SITE NUMBER:
DXL00642
BU #: 843595
v TAP/SANDY
440 NORTH DENTON TAP
COPPELL, TX 75019
EXISTING 80'-0" MONOPOLE
ISSUED FOR:
REV DATE DRWN DESCRIPTION DES./QA
0 02/26/21 NH CONSTRUCTION MEP
OF
•MARK E. PATTERSON
..%............................
t...
,0 113892
ADNAL
02/26/2021
TEXAS FIRM NUMBER 16059
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER
TO ALTER THIS DOCUMENT.
SHEET NUMBER:
REVISION:
C-2
0
Planning Administrative
Approval
cOFFEL%
NIA
05/13/2021
EQUIPMENT DESCRIPTION TABLE
1 SCALE: NOT TO SCALE
\ / AT&T
1801 VALLEY VIEW LANE
FARMERS BRANCH TX 75234
TOWER TOP EQUIPMENT SCHEDULE
(FINAL)
ANTENNA
SECTOR
ANTENNA
ELEVATION
ANTENNA
AZIMUTH
CATEGORY
PROPOSED CONFIGURATION
OTY.
a
a
a
78'-0"
8'
ANTENNA (Al)
JAHH-65B—R3B—V3
1
ANTENNA (A2)
JAHH-65B-R3B-V3
1
ANTENNA (A3)
AIR 6449 N77
1
CROWN
0 CASTLE
1701 DIRECTORS BLVD, SUITE 700
AUSTIN, TX 78744
ANTENNA (A5)
NNH4-65B—R6H4
1
TOWER DIPLEXERS
CBC78T—DS-43
1
RRHs
RRUS 32 B30
1
RRUS 32 B66A
1
POD
POWER OF DESIGN
11490 BLUEGRASS PKWY
LOU ISVI LLE, KY 40299
502-437-5252
RRUS 4415 D25
1
RRUS 4478 B12
1
RRUS 4478 B14
1
RRUS 4478 35
1
AT&T SITE NUMBER:
DXL00642
BU #: 843595
DENTON TAP/SANDY LAKE
440 NORTH DENTON TAP
COPPELL, TX 75019
EXISTING 80'-0" MONOPOLE
m
78'-0"
128'
ANTENNA (131)
JAHH-65B—R3B—V3
1
ANTENNA (132)
JAHH-65B—R3B—V3
1
ANTENNA (B3)
AIR 6449 N77
1
ANTENNA (B5)
NNH4-65B—R6H4
1
TOWER DIPLEXERS
CBC78T—DS-43
1
RRHs
RRUS 32 B30
1
RRUS 32 B66A
1
RRUS 4415 B25
1
RRUS 4478 D12
1
ISSUED FOR:
RRUS 4478 B14
1
REV
DATE
DRWN
DESCRIPTION
DES.ZQA
RRUS 4478 35
1
0
02/26/21
NH
CONSTRUCTION
MEP
78'-0"
248'
ANTENNA (C1)
JAHH-65B—R3B—V3
1
ANTENNA (C2)
JAHH-65B—R3B—V3
1
ANTENNA (C3)
AIR 6449 N77
1
MARK E. PATTERSON
.....t.............................t.....
/113892
VICENS10),.f\��
SADNAL
02/26/2021
TEXAS FIRM NUMBER 16059
ANTENNA (C5)
NNH4-65B—R6H4
1
TOWER DIPLEXERS
CBC78T—DS-43
1
RRHs
RRUS 32 B30
1
RRUS 32 B66A
1
RRUS 4415 B25
1
RRUS 4478 B12
1
RRUS 4478 B14
1
RRUS 4478 35
1
COAX/FIBER/DC
7/8"
20
3/4"
6
3/8"
3
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OP A LICENSED PROFSSSIONAL ENGI SSK
TO ALTER THIS DOCUMENT.
MISCELLANEOUS
I
DC6-48-60-18-8C
1
DC6-48-60-18-8C-EV
1
SHEET NUMBER: REVISION:
11 C-3-, 0
DC6-48-60-18-8F
I
2
I
--�
SNAP -IN HANGER
HANGER ADAPTER
GROMMET
DC/FIBER
CABLE BUNDLE
DOUBLE CLAMP
INSTALLER NOTES:
1. COMPLY WITH MANUFACTURERS
INSTRUCTIONS TO ENSURE THAT ALL RRHs
RECEIVE ELECTRICAL POWER WITHIN 24
HOURS OF BEING REMOVED FROM THE
MANUFACTURER'S PACKAGING.
2.DO NOT OPEN RRH PACKAGES IN THE RAIN.
3. ALL PIPES, BRACKETS, AND MISCELLANEOUS
HARDWARE TO BE GALVANIZED UNLESS
\ NOTED OTHERWISE.
AT&T RRH
AND HARDWARE
SUPPLIED BY
MANUFACTURER (TYP)
HANGER AD,
SNAP -IN
MOUNTING BRACKET
(SUPPLIED W/ ANTENNA)
MOUNTING PIPE
(TYP)
ANTENNA
MOUNTING PIPE
COMMSCOPE - RR-FA2
AND HARDWARE
(TYP)
MOUNTING BRACKET
(SUPPLIED W/ ANTENNA)
�-,�ANTENNA WITH RRHs MOUNTING DETAIL
�JSCALE: NOT TO SCALE
CAB
HANGER ADAPTER GROMN
BUTTERFLY HANGER
SNAP -IN HANGER
HANGER ADAPTER GROMMET DETAILS
SCALE: NOT TO SCALE
NEW ANTENNA
BUTTERFLY HANGER
CABL
HANGER ADAPTER GROMN
CLIP -IN HANGER
CLIP -IN HANGER
Planning Administrative
App-1
COPPELL
.gym
05/13/2021
AT&T
1801 VALLEY VIEW LANE
FARMERS BRANCH TX 75234
0 - CROWN
CASTLE
1701 DIRECTORS BLVD, SUITE 700
AUSTIN, TX 78744
�14 Po
D-
POWER OF DESIGN
11490 BLUEGRASS PKWY
LOU ISVI LLE, KY 40299
502-437-5252
AT&T SITE NUMBER:
DXL00642
BU #: 843595
v TAP/SANDY
440 NORTH DENTON TAP
COPPELL, TX 75019
EXISTING 80'-0" MONOPOLE
ISSUED FOR:
REV DATE DRWN DESCRI7DON DES./QA
0 02/26/21 NH CONSTRUCTION MEP
N
MARK E. PATTERSON
�....%............................
t....
,0 113892
��� S /CENSQ ..x
V b - ONAL E�
02/26/2021
TEXAS FIRM NUMBER 16059
IT IS A VIOLATION OF LAW POR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET NUMBER:
REVISION:
C-4
1 0
Ericsson 64Tx
AIR 6449 B77D/ C-Band
• Advanced Antenna System (AAS)
• 64TX/64RX with 192 AE
• Up to 320W RF Power
• EIRP up to 79 dBm
• Up to 200 MHz IBW&CBW
• Max total carrier BW is 200MHz for NR
• Support number of layers: DVUL 16/8
N0.6uaelaYGeaq
xexp
VM
oatn
vrepx
pnn-1
uuimnt
aal..t
.o,�,ena.•.
mimmt
tiros mnt
roan
roam
iiixaei
• 4 x 25 Gbps eCPRI, (compatible to 10G) eCPRI SFP28
-48 VDC, max 1540 W
• -40 to '55C,(Ind Solar Load)
Typical power consumption <1130 W.
NOTE: POWER OF DESIGN GROUP, NOR
OUR ENGINEER IS RESPONSIBLE FOR
DESIGN OR MANUFACTURE OF THE
SPECS SHOWN ON THIS SHEET.
PLEASE CONTACT THE MANUFACTURER
FOR ANY QUESTIONS OR CONCERNS.
/-�ANTENNA SPECIFICATIONS
SCALE: NOT TO SCALE
I
DATA SHEET
Rooftop / Towertop
The DC6-48-60-18-8C-EV is
designed to provide the ultimate
coordination between the SPD and
the RRH/RRU by offering
industry -leading low -clamping
voltage of 160V and extremely
robust protection for use in a
high DC voltage environment.
Capable of providing
12.5kA (10/350 Ns) max per
circuit surge capacity for
Lip to 6 -48V DC circuits.
DC Surge Protection Solutions
DC6-48.60-18-8C-EV
Overvoltage Protection and Fiber Distribution/Cable Management Solution
tow 1 b,
StrikesoW
r—
Features
• Provides discrete protection for six individual -48V DC circuits
• Surge protection of 90kA 8/20 ps
• Maximum impulse current 12.5kA 10/350 ps
• Fiber connections for up to 18 fiber pair
• Simplifies inter -connectivity and cable management for DC conductors
• UL 1449 4th Edition Type 2 protective device
• IEC 61643-11 Class I protection for DC applications
• Form C relay contacts included, allowing remote monitoring of suppressor status
• Copper -coated lid to reduce power line interference
• Patented design
• Patented Strikesorb technology ensures lowest let -through voltage available in the
industry, providing enhanced coordination with the RRH/RRU
• Raycap recommends that DC protection system be installed within 5 meters
of the radio
Benefits
• Strikesorb modules are fully recognized to UL 1449 4th Edition, and IEC 61643-11
Safety Standards, meeting all intermediate and high current fault requirements to
facilitate use in original equipment manufacturers (OEM) applications
• Strikesorb offers unique maintenance -free protection against direct lightning currents
• Design provides maximum flexibility for installation
• NEMA 4X enclosure allows for indoor or outdoor installation
Raycap wwt4r.Mycap.com
�SQUID SPECIFICATIONS
�JSCALE. NOT TO SCALE
Strikesorb is a registered trademark of Raycap
Q 2018 Raycap All rights reserved.
G02-01-203 180122
Planning Administrative
Approval
COPPELL
05/13/2021
AT&T
1801 VALLEY VIEW LANE
FARMERS BRANCH TX 75234
CCCROWN
CASTLE
1701 DIRECTORS BLVD, SUITE 700
AUSTIN, TX 78744
40POD
POWER OF DESIGN
11490 BLUEGRASS PKWY
LOUISVILLE, KY 40299
502-437-5252
AT&T SITE NUMBER:
DXL00642
BU #: 843595
v TAP/SANDY
440 NORTH DENTON TAP
COPPELL, TX 75019
EXISTING 80'-0" MONOPOLE
ISSUED FOR:
REV
DATE
DRWN
DESCF=ON
DES./QA
0
02/26/21
NH
CONSTRUCTION
MEP
PEE OF
i....................'r.*
•MARK E. PATTERSON
..%............................ �j...
FSS/ONAL ECG
02/26/2021
TEXAS FIRM NUMBER 16059
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET NUMBER:
REVISION:
C-5.11
0 1
�
J
NNH4-65B-R6H4
12-port sector antenna, 4x 698-896 and 8x 1695-2360 MHz, 65°
HPBW, 6x RET.
.us W` • i • a . _
General Specifications
Antenna Type
Band
Effective Projective Area (EPA), frontal
Effective Projective Area (EPA), lateral
Grounding Type
Performance Note
Radome Material
Radiator Material
Reflector Material
RF Connector Interface
RF Connector Location
RF Connector Quantity, high band
RF Connector Quantity, low band
RF Connector Quantity, total
• Features broadband Low Band (698-896 MHz) and High Band (1695-2360 MHz) arrays for
4T4R (4X MIMO) capability for Band 14, AWS, PCS and WCS applications.
• Non -stacked high band array design provides higher gain and narrower vertical beamwidth
than traditional antenna designs.
• Independent tilt for all arrays.
• Array configuration provides capability for 4T4R (4x MIMO) on Low band and Dual 4T4R (4x
MIMO) on High band
• Optimized SPR performance across all operating bands
• Excellent wind loading characteristics
• Supports re -configurable antenna sharing capability enabling control of the internal RET
system using up to two separate RET compatible OEM radios
Sector
Multiband
0.65 m2 1 6.997 ft2
0.22 m2 1 2.368 ft2
RF connector inner conductor and body grounded to reflector and
mounting bracket
Outdoor usage I Wind loading figures are validated by wind tunnel
measurements described in white paper WP-112534-EN
Fiberglass, LIV resistant
Low loss circuit board
Aluminum
4.3-10 Female
Bottom
8
4
12
Remote Electrical Tilt (PET) Information, General
RET Hardware Commil v2
RET Interface 8-pin DIN Female 18-pin DIN Male
NOTE: POWER OF DESIGN GROUP, NOR
OUR ENGINEER IS RESPONSIBLE FOR
DESIGN OR MANUFACTURE OF THE
SPECS SHOWN ON THIS SHEET.
PLEASE CONTACT THE MANUFACTURER
FOR ANY QUESTIONS OR CONCERNS.
��ANTENNA SPECIFICATIONS
SCALE: NOT TO SCALE
NNH4-65B-R6H4
RET Interface, quantity
Dimensions
Width
Depth
Len gth
Array Layout
MT
WYIY2 JY3Y4
Left Right
Bottom
2female 12male
498 mm 1 19.606 in
197 mm 1 7.756 in
1828 mm 1 71.969 in
Hz)
Conns
IRET
AISG RET UID
126
6
1-2
1
CPxxxxxxxxxbcxxrocmm.1
3-4
2
CPxxxxxxxxxxxxxxxmm.2
Y1
1695-2360
5-6
3
CPxxxxxxxxxxxxxxxmm.3
YZ
1695-2360
7-8
4
CPxxxxxxxxxxxxxxxmm.4
Y3
1695-2360
9-10
5
CPxxxxxxxxx)o=xxmm.5
Y4
1695-2360
11-12
6
CPxxxxxxxxxxxxxxxmm.6
(Sizes of colored boxes arc not
true depictions of array sizes)
Port Configuration
Planning Administrative
Approval
COPPELL
05/13/2021
AT&T
1801 VALLEY VIEW LANE
FARMERS BRANCH TX 75234
CROWN
CASTLE
1701 DIRECTORS BLVD, SUITE 700
AUSTIN, TX 78744
`14 PO
D
POWER OF DESIGN
11490 BLUEGRASS PKWY
LOU ISVI LLE, KY 40299
502-437-5252
AT&T SITE NUMBER:
DXL00642
BU #: 843595
v TAP/SANDY
440 NORTH DENTON TAP
COPPELL, TX 75019
EXISTING 80'-0" MONOPOLE
ISSUED FOR:
REV DATE DRWN DESCRIPTION DES./QA
0 02/26/21 NH CONSTRUCTION MEP
OF r-qvt
.�I
MARK E. PATTERSON
....%............................ r....
a 113892 :/4�,
���
/ONAI-
���
02/26/2021
TEXAS FIRM NUMBER 16059
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET NUMBER:
REVISION:
C - 5.2
0
CBC78T-DS-43 I E14F05P19
BRACKET
a E,
O E
® O E-
698.803 824-894 E
824.8N 15OR-=,
2X GND M6 X l.D
6X 4.9.10 CONNECTOR r VENTING MEMBRANE
D O ♦A
p—0 _
(, E = E £
0 0
°_1 O
176mm�
16.9 N]
Electrical Specifications
Impedance 50 ohm
License Band, Band Pass CEL 850 1 USA 700 1 USA 750
Electrical Specifications, Common Port
Composite Power, RMS 250 W
Electrical Specifications, do Power/Alarm
do/AISG Pass -through Method
Auto sensing
do/AISG Pass -through Path
See logic table
Lightning Surge Current
10 kA
Lightning Surge Current Waveform
8/20 waveform
NOTE: POWER OF DESIGN GROUP, NOR
OUR ENGINEER IS RESPONSIBLE FOR
DESIGN OR MANUFACTURE OF THE
SPECS SHOWN ON THIS SHEET.
PLEASE CONTACT THE MANUFACTURER
FOR ANY QUESTIONS OR CONCERNS.
/-� DIPLEXER SPECIFICATIONS
SCALE: NOT TO SCALE
IJ:T.--inn. W
RRUS 4478
CPR I 2 ports x 2.5/4.9/9.8/10.1 Gbps. Install 1 SFP and conned 1 fiber pair to the RRUS 4478
during initial install.
Only use Ericsson supplied and approved SFPs RDH10265/25
> 2 external alarm inputs
Max wind load @ 50m/sec = 26ON
Breaker size = 25A, DC Power Consumption = 670 W (for dimensioning)
200mm horizontal separation required for side by side mounting
> 200mm separation required from antenna backplane to radio
400mm vertical outdoor/indoor separation required between 2 radios
500mm vertical separation below antenna
Min, Max DC cable size from squid to radio = 10,8 AWG
- Adapter is required for 2-wire connection
- Shielded DC cable is required
Ground cable size = 2AWG
> Dimensions (incl. handles, feet and sunshield, w/o fan unit)
- Height: 16.5" (420 mm)
- Width: 13.4" (340 mm)
- Depth: 7.7" (196 mm)
> Weight, excl. mounting hardware = 59.9lbs (27.2 kg)
RRUS 32 Detaslleet fa Turf Vendors I Conmerclal in confidence I Re,A 1 2016-01-21 1 Page
,-� RRH SPECIFICATIONS
�L SCALE: NOT TO SCALE
i
4 3 i 2
NOTES
O GEIEJUL
+. NiN>:Twc ouersRra2aew asfiacsrs
,�mRR4TEa1Mm_„_rt _
240EaGN NOTEa
z+ 81aMTW4tEn 1E6swro.
05.
V 60' ANaE
D eo v�taF cn�iasx.5aECNlnEouwuExrs D
,c csT
scvacw,caa
® 8 50 [215 9]
c c
A
18.00[457.2]
p� o
Ed
2 50[63 5]
m.d4[11.1] TYP
13.56[344.5] (1641 [4168])
3.0[75,21
2 44 [61 91
R28[7.1j TYP
4
PATENT PENDING
3
2
Z DUAL RRH MOUNT SPECIFICATIONS
�JSCALE: NOT TO SCALE
,.
a. Olt
COPE, INC. OF NORTH CAROLINA
... o.a ERR-FA2
.r
�+4i1r1medBa
�. FASTACCESSDWLRRU MOUNT A
=TT1:2� RR-FA2
Planning Administrative
Approval
COPP'EgLL
05/13/2021
AT&T
1801 VALLEY VIES' LANE
FARAMRS BRANCH TX 75234
CCCROWN
CASTLE
1701 DIRECTORS BLVD, SUITE 700
AUSTIN, TX 78744
POD
POWER OF DESIGN
11490 BLUEGRASS PKWY
LOUISVILLE, KY 40299
502-437-5252
AT&T SITE NUMBER:
DXL00642
BU #: 843595
v TAP/SANDY
440 NORTH DENTON TAP
COPPELL, TX 75019
EXISTING 80'-0" MONOPOLE
ISSUED FOR:
REV
DATE
DRWN
DESCF=ON
DES./QA
0
02/26/21
NH
CONSTRUCTION
MEP
02/26/2021
TEXAS FIRM NUMBER 16059
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET NUMBER: REVISION:
G 5.3 0
TO ANTENNA COAX
COPPER/GALVANIZED GROUND BAR
o o o o 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
TWO HOLE LONG BARREL
COMPRESSION LUG (TYR)
NOTES:
1. DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED.
2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS.
3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO ANTENNA MOUNT STEEL.
/--,---\ ANTENNA SECTOR GROUND BAR DETAIL
SCALE: NOT TO SCALE
TO TOWER MOUNTED EQUIPMENT
()4q
TO ANTENNAMONOPOLE
ANTENNA GROUND BAR
LOCATED AT MCL
(BONDED TO TOWER STEEL)
STANDARD C2
HOLE LUG (TYP)
CABLE GROUND(T#6
STRANDED CUWIRGREEN,600VINSULATION
(OR AS PRWITH
GROUND KIT
MECHANICAL CONNECTION
(TYR)
COAX CABLE COAX GROUND BAR WITH
INSULATORS, CONNECTED
(TYP FOR ALL) \ DIRECTLY TO THE BOTTOM
OF MONOPOLE. SEE NOTE 1.
TO BITS EQUIPMENT VIA
TRAY OR ICE BRIDGE
TO ANTENNA COAX
T/FINISH GRADE
Ili//�— COPPER/GALVANIZED GROUND BAR
o 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 @ N_
w
#2 SOLID TINNED COPPER o
CONDUCTOR TO TOWER/SHELTER z o
NJO HOLE LONG BARREL COMPRESSION LUG GROUND RING (2 TYR. FOR n
(TYR) BOTTOM GROUND BAR ONLY) o
NOTES:
1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS.
2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY).
3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER.
-\TOWER/SHELTER GROUND BAR DETAIL
L SCALE: NOT TO SCALE
STAINLESS STEEL BOLT
(TYP)
STAINLESS STEEL
FLAT WASHER
2-HOLE CRIMP/ (TYP)
COMPRESSION
CONNECTOR
GROUND
BAR
STAINLESS STEEL
FLAT WASHER
STAINLESS STEEL (TYR)
BELLVILLE WASHER STAINLESS STEEL NUT
(TYR) (TYR)
SINGLE CONNECTOR AT GROUND BARS
STAINLESS STEEL BOLT
STAINLESS STEEL
FLAT WASHER
DRAGON TOOTH WASHER
(TYR)
STEEL
2/0 TINNED BARE I
COPPER WIRE 2-HOLE CRIMP/
MONOPOLE PIER COMPRESSION
CONNECTOR
T GROUND WIRE
SEE NOTE 3
GROUND WIRE
NOTE 3
INSPECTION WELL
EXOTHERMIC WELD (TYP)
NOTES:
1. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA
LOCATIONS AND CONNECTION ORIENTATION. COAXIAL CABLES EXCEEDING 200 FEET ON THE
TOWER SHALL HAVE GROUND KITS AT THE MIDPOINT. PROVIDE AS REQUIRED.
2. ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE USA INC.
TOWERS. ALL MECHANICAL CONNECTIONS SHALL BE TREATED WITH AN ANTI -OXIDANT COATING.
3. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE
RECOGNIZED EDITION OF ANSI/TIA 222 AND NFPA 780.
4 TYPICAL ANTENNA CABLE GROUNDING
SCALE : NOT TO SCALE
STAINLESS STEEL
FLAT WASHER
(TYR)
STAINLESS STEEL STAINLESS STEEL NUT
BELLVILLE WASHER (TYR)
(TYP)
SINGLE CONNECTOR AT STEEL OBJECTS
STAINLESS STEEL SELF -DRILLING STAINLESS STEEL
METAL SCREW
FLAT WASHER
(TYR)
(TYR)
2-HOLE CRIMP/
COMPRESSION
CONNECTOR
DRAGON TOOTH J
METALLIC OBJECT
WASHER
(TYP)
SINGLE CONNECTOR AT METALLIC/STEEL
OBJECTS
HARDWARE DETAIL FOR EXTERIOR CONNECTIONS
5
SCALE: NOT TO SCALE
8" PVC PLUG
8" PVC PLUG CPLG. (THRD.)
SUBGRADE
#2 SOLID (TEST LOOP)
NOTCH SIDES OF 8" PVC SCH 40 PIPE
TO ALLOW EXIT/ENTRANCE OF
EXOTHERMIC WELD GROUND RING WIRE
TRENCH BOTTOM
2/0 TINNED CU EXTERNAL
CADWELD TEST LOOP TO TOWER GROUND RING WIRE
GROUND RING WIRE
NOTES: 5/8" 0 x 10'-0" LONG COPPER CLAD GROUND ROD
1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE
VERTICAL
2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE.
(WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D)
(� INSPECTION WELL DETAIL
`� SCALE: NOT TO SCALE
6" WIDE METALLIC HTEL
GRADE WARNING/LOCATOR TAPE AT
12" DEPTH
N
0
z
c�oz
EXOTHERMIC WELD
0
w
GROUND RING #2 COPPER WIRE
SOLID, TINNED FOR CARRIER AND ICE
BRIDGE GROUND LOOP
GROUND RING 2/0 FOR
TOWER GROUND LOOP
GROUND ROD COPPER
CLAD STEEL ROD W/MIN.
5/8 0 x 10'-0" LONG
NOTES:
1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE
VERTICAL
2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE.
(WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D)
GROUND ROD DETAIL
6
SCALE: NOT TO SCALE
Planning Administrative
Approval
COPPEL
05/13/2021
AT&T
1801 VALLEY VIEW LANE
FARMERS BRANCH TX 75234
0 - CROWN
CASTLE
1701 DIRECTORS BLVD, SUITE 700
AUSTIN, TX 78744
`441 POD -
POWER OF DESIGN
11490 BLUEGRASS PKWY
LOU ISVI LLE, KY 40299
502-437-5252
AT&T SITE NUMBER:
DXL00642
BU #: 843595
v TAP/SANDY
440 NORTH DENTON TAP
COPPELL, TX 75019
EXISTING 80'-0" MONOPOLE
ISSUED FOR:
REV DATE DRWN DESCRIPTION DES./QA
0 02/26/21 NH CONSTRUCTION MEP
02/26/2021
TEXAS FIRM NUMBER 16059
IT IS A VIOLATION OF LAW POR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET NUMBER:
REVISION:
G-1
0
WEATHERPROOFING KIT
(SEE NOTE 3)
ANTENNA CABLE
_ I_.
TYPE 2—YA-2
TYPE XA
TYPE YA-2
TYPE GY
TYPE W
TYPE VN
TYPE NC
TYPE SS
TYPE GR
WIRE SIZE
BURNDY LUG
BOLT
SIZE
#6
AWG
GREEN INSULATED
YA6C-2TC38
3/8" -
16 NC
S 2
BOLT
#2
AWG
SOLID TINNED
YA3C-2TC38
3/8" -
16 NC
S 2
BOLT
#2
AWG
STRANDED
YA2C-2TC38
3/8" -
16 NC
S 2
BOLT
#2/0 AWG STRANDED
YA26-2TC38
3/8" -
16 NC
S 2
BOLT
#4/0 AWG STRANDED YA28-2N
BURNDY GROUND LUG W/
LONG BARREL
(SEE CHART)
1/2" — 16 NC S 2 BOLT
NUT
(TYP)
LOCK WA*BARBOLT
TYPE VS TYPE VB TYPE PT TYPE GT'
NOTE: GROUN1. ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC
MOLDS TO BE USED FOR THIS PROJECT. (TYR)
2. MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD.
BURNDY TWO HOLE LUG W/
LONG BARREL
(SEE CHART)
CADWELD GROUNDING CONNECTIONS
SCALE: NOT NO-OX
TO SCALE BARE WIRE TO BE
AT BOTH ENDS
(TYPICALLY)
12' TO 24„
120" MAX.
1
#6 AWG STRANDED COPPER GROUND WIRE
(GROUNDED TO GROUND BAR). SEE NOTE 1 & 2
d
N �
CABLE GROUND KIT
CABLE CONNECTOR
NOTES:
1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS
DIRECT GROUND
WIRE DOWN TO GROUND BAR.
2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS
SUPPLIED OR
RECOMMENDED BY CABLE MANUFACTURER.
3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD
SHRINK SHALL NOT
BE USED.
CABLE GROUND KIT CONNECTION
3 SCALE: NOT TO SCALE
3/8-11x1" TAMPER
RESISTANT BOLT
(TYR)
INSULATORS
SEE NOTE 2.
(TYP)
TO ANTENNAS
COAX JUMPER (TYP.)
CONNEC
WEATHERPROOFING
(TYP. SEE NOTE
ANTENNA CA
TO BITS EQUIPMENT (7
HEAT SHRINK
(CLEAR)
GROUNDING
CONDUCTOR
STRANDED (GREEN INSULATED) ONLY FOR #6 AWG
(SEE CHART)
WEATHERPROOFING
KIT
(TYR)
NOTES:
GROUND KIT
1. ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
(TYR)
ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL
HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG,
FLAT WASHER AND NUT.
y6 AWG
/---'\ MECHANICAL LUG CONNECTION
COPPER/GALVANIZED
SCALE: NOT TO SCALE
COAX GROUND BAR
BONDED DIRECTLY TOWER
NOTES:
1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND
WIRE DOWN TO ANTENNA GROUND BAR.
2. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE
USED.
/---\GROUND CABLE CONNECTION
Q SCALE: NOT TO SCALE
00
WALL BRACKET 0
(TYP) ® 0 NOTE: MINIMUM OF S/S NUT
® 0 3 THREADS TO BE (TYR)
VISIBLE
® ® ® ® (TYR)
0 0 S/S SPLIT
® 2 HOLE LONG WASHER
® 0 BARREL TINNED (TYR)
® UNIVERSAL COPPER SOLID COPPER
® GROUND BAR (4"x20") LUG S/S FLAT
LOCK WASHER (TYP) WASHER
P/N M10 (TYP)
(TYP)
TWO -HOLE
COMPRESSION LUG TIN COATED SOLID
NOTES: COPPER BUS BAR S/S FLAT
WASHER
1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE CHERRY INSULATOR (TYR)
USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY QAS-STD-10091. NO INSTALLED IF REQUIRED
MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, S/S BOLT
CAD -WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. (TYR)
2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL
USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS.
GROUND BAR DETAIL
� SCALE: NOT TO SCALE
T,, LUG DETAIL
�JSCALE: NOT TO SCALE
#6 AWG MIN. FROM ANTENNA
CABLE GROUND KIT
GROUND BAR ON SHELTER.
BRIDGE, OR ON ANTENNA TON
*TWO HOLE LUG, OR
EXOTHERMIC WELD TO BE USED
WITH #2 AWG BARE CONDUCTOR
WIRE TO BUILDING SERVICE
GROUND OR GROUND RING
,,.� GROUNDWIRE INSTALLATION
�SCALE: NOT TO SCALE
#2 TINNED SOLID IN 3/4" LIQUID TIGHT
CONDUIT FROM 24" BELOW GRADE TO
WITHIN 3" TO 6" OF CAD -WELD
TERMINATION POINT. EXPOSED END OF
THE LIQUID TIGHT CONDUIT MUST BE
SEALED WITH SILICONE CAULK.
CADWELD
(TYP)
TIE INTO EXISTING GROUND RII
/'�_TRANSITIONING GROUND DETAIL
SCALE: NOT TO SCALE
PE
GROUNDING SHALL BE
ELIMINATED WHEN GROUND BAR
IS ELECTRICALLY BONDED TO
METAL TOWER
Planning Adminisi,Mi
Approval
COPi'LLI,
05/13/2021
v
AT&T
V
1801 VALLEY VIEW LANE
FARMERS BRANCH TX 75234
- CROWN
CASTLE
1701 DIRECTORS BLVD, SUITE 700
AUSTIN, TX 78744
POD
POWER OF DESIGN
11490 BLUEGRASS PKWY
LOU ISVI LLE, KY 40299
502-437-5252
AT&T SITE NUMBER:
DXL00642
BU #: 843595
v TAP/SANDY
440 NORTH DENTON TAP
COPPELL, TX 75019
EXISTING 80'-0" MONOPOLE
ISSUED FOR:
REV DATE DRWN DESCF=ON DES./QA
0 02/26/21 NH CONSTRUCTION MEP
MARK E. PATTERSON
t............................. I....
a 113892
FSS/ONAL E��
02/26/2021
TEXAS FIRM NUMBER 16059
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET NUMBER:
REVISION:
G-2
1 0