Loading...
876558_F3-Coppell_Middle_S_(DXL02813_Dividend_Dr)_Final_Rev_1_05-27-21_-_Sealed_v1.ADM_APPAT&T SITE NUMBER:AT&T SITE NAME:AT&T FA CODE:AT&T PACE NUMBER:SITE TYPE:BUSINESS UNIT #:SITE ADDRESS:COUNTY:TOWER HEIGHT:DXL02813DIVIDEND DR10152317MRNTX068008MONOPOLE8765581301 WRANGLERCOPPELL, TX 75019DALLAS71'-6"PROJECT: AT&T PRIORITYNOTE:PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THECROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGERALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11X17.CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTINGDIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALLIMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANYDISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BERESPONSIBLE FOR SAME.APPLICABLE CODESSITE INFORMATIONCARRIER/APPLICANT:SHEET #DRAWING INDEXSHEET DESCRIPTIONONCOR888-313-6862ELECTRIC PROVIDER:AT&TTBDTELCO PROVIDER:GROUND ELEVATION:32° 56' 5.32"-97° 0' 5.83"UFACILITY IS UNMANNED AND NOT FORHUMAN HABITATIONOCCUPANCY CLASSIFICATION:A.D.A. COMPLIANCE:MAP/PARCEL #:DALLAS COUNTYJURISDICTION:N/AF3- COPPELL MIDDLE SDALLASAREA OF CONSTRUCTION: EXISTINGNAD83TBDCROWN CASTLE USA INC.2000 CORPORATE DRIVECANONSBURG, PA 15317TOWER OWNER:IIBTYPE OF CONSTRUCTION:523'-4"1301 WRANGLERCOPPELL, TX 75019CROWN CASTLE USA INC.SITE NAME:PROJECT DESCRIPTIONLAT/LONG TYPE:LONGITUDE:LATITUDE:CURRENT ZONING:COUNTY:SITE ADDRESS:PROJECT TEAMTITLE SHEETT-1FINAL OVERALL SITE PLANC-1C-3FINAL TOWER ELEVATION & ANTENNA PLANSGENERAL NOTEST-2EQUIPMENT DESCRIPTION TABLETHE PURPOSE OF THIS PROJECT IS TO PROPOSE AN ANTENNAMODIFICATION ON AN EXISTING WIRELESS SITEC-4DETAILSC-5EQUIPMENT SPECSC-6.1G-1GROUNDING DETAILSG-2GROUNDING DETAILSLOCATION MAPNO SCALEDRIVING DIRECTIONS FROM DALLAS/FORT WORTH INTERNATIONAL AIRPORT: TAKE TX-114 E AND FREEPORT PKWY TO WRANGLER DR IN COPPELL. HEADSOUTH ON INTERNATIONAL PKWY. USE THE LEFT LANE TO STAY ON INTERNATIONAL PKWY. USE THE RIGHT 2 LANES TO MERGE ONTO TX-114 E TOWARDIRVING/DOWNTOWN DALLAS. TAKE THE FREEPORT PKWY EXIT. USE ANY LANE TO TURN LEFT ONTO FREEPORT PKWY. FOLLOW WRANGLER DR AND WRANGLER CIR TOYOUR DESTINATION. TURN RIGHT ONTO WRANGLER DR. TURN RIGHT ONTO WRANGLER CIR. TURN LEFT TO STAY ON WRANGLER CIR. SLIGHT LEFT. 1301 WRANGLERCOPPELL, TX 75019.C-6.2EQUIPMENT SPECSAT&T TOWER ASSET GROUP1801 VALLEY VIEW LANEFARMERS BRANCH, TX 75234DESIGN PACKAGE BASED ON THE APPLICATIONID: 542003REVISION: 0DESIGN PACKAGE BASED ON THE RFDSREVISION: 1DATE: 2/9/21STRUCTURAL ANALYSIS:BY OTHERSREFERENCE DOCUMENTS:MOUNT ANALYSIS:BY OTHERSCALL TEXAS ONE CALL(800) DIG-TESSCALL 3 WORKING DAYSBEFORE YOU DIG!A&E FIRM:CROWN CASTLEUSA INC. DISTRICTCONTACTS:TELECAD WIRELESS SITE DESIGN1961 NORTHPOINT BLVD, SUITE 130HIXSON, TN 37343PHONE: 423-843-9500BARCLAY HAWLEY - PROJECT MANAGEREMAIL: BARCLAY.HAWLEY@CROWNCASTLE.COM1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 77057JOSEPH OLSEN - A&E SPECIALISTEMAIL: JOSEPH.OLSEN@CROWNCASTLE.COMPHONE: 763-852-0573JOE MCCALL - CONSTRUCTION MANAGEREMAIL: JOE.MCCALL@CROWNCASTLE.COMFINAL TOWER CONFIGURATION:·(12) ANTENNAS·(18) RRUs·(4) SQUIDs·(2) DIPLEXERs·(12) COAX CABLES (7/8")·(1) COAX CABLE (3/8")·(3) FIBER CABLES (3/8")·(6) DC CABLES (3/4" )· (2) DC CABLES (7/8")FINAL GROUND CONFIGURATION:·NO CHANGESIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 7705703/15/21CDRJWYT-11REVISION:SHEET NUMBER:1961 NORTHPOINT BLVD, SUITE 130HIXSON, TN 37343PH: 423-843-9500 / FAX: 423-843-9509SHEET TITLE:AT&T SITE NUMBER:DXL02813BU #: 876558F3- COPPELL MIDDLE S1301 WRANGLERCOPPELL, TX 75019EXISTING 71'-6" MONOPOLEISSUED FORCONSTRUCTION575 MOROSGO DRIVEATLANTA, GA 30324-3300TX FIRM NUMBER 2108713/15/21CDRJWYISSUED FORCONSTRUCTIONTITLE SHEETSITE LOCATIONC-2PLUMBING DIAGRAMALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCEWITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THELOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUEDTO PERMIT WORK NOT CONFORMING TO THESE CODES:CODE TYPECODEBUILDING 2015 IBCMECHANICAL 2015 IMCELECTRICAL 2017 NECATTACHEDMOUNT MODIFICATION DESIGNDigitally signed by Christopher Roberts Date: 2021.05.27 18:17:30 -04'00'PlanningAdministrative Approval08/02/2021 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 7705703/15/21CDRJWYT-21REVISION:SHEET NUMBER:1961 NORTHPOINT BLVD, SUITE 130HIXSON, TN 37343PH: 423-843-9500 / FAX: 423-843-9509SHEET TITLE:AT&T SITE NUMBER:DXL02813BU #: 876558F3- COPPELL MIDDLE S1301 WRANGLERCOPPELL, TX 75019EXISTING 71'-6" MONOPOLEISSUED FORCONSTRUCTION575 MOROSGO DRIVEATLANTA, GA 30324-3300TX FIRM NUMBER 2108713/15/21CDRJWYISSUED FORCONSTRUCTIONGENERAL NOTESDigitally signed by Christopher Roberts Date: 2021.05.27 18:17:41 -04'00'PlanningAdministrative Approval08/02/2021 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 7705703/15/21CDRJWYC-11REVISION:SHEET NUMBER:1961 NORTHPOINT BLVD, SUITE 130HIXSON, TN 37343PH: 423-843-9500 / FAX: 423-843-9509SHEET TITLE:AT&T SITE NUMBER:DXL02813BU #: 876558F3- COPPELL MIDDLE S1301 WRANGLERCOPPELL, TX 75019EXISTING 71'-6" MONOPOLEISSUED FORCONSTRUCTION575 MOROSGO DRIVEATLANTA, GA 30324-3300TX FIRM NUMBER 2108713/15/21CDRJWYISSUED FORCONSTRUCTIONFINAL OVERALL SITE PLANDigitally signed by Christopher Roberts Date: 2021.05.27 18:18:29 -04'00'PlanningAdministrative Approval08/02/2021 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 7705703/15/21CDRJWYC-21REVISION:SHEET NUMBER:1961 NORTHPOINT BLVD, SUITE 130HIXSON, TN 37343PH: 423-843-9500 / FAX: 423-843-9509SHEET TITLE:AT&T SITE NUMBER:DXL02813BU #: 876558F3- COPPELL MIDDLE S1301 WRANGLERCOPPELL, TX 75019EXISTING 71'-6" MONOPOLEISSUED FORCONSTRUCTION575 MOROSGO DRIVEATLANTA, GA 30324-3300TX FIRM NUMBER 2108713/15/21CDRJWYISSUED FORCONSTRUCTIONPLUMBING DIAGRAMDiagram - SectorAtoll Site Name -A, B, CDIVIDEND DRComments:Diagram File Name -PRELIM.vsdLocation Name -DIVIDEND DRMarket -DALLAS FT. WORTHMarket Cluster -NORTH TEXASANTENNA POSITION 1/22 JAHH-65B/CSide by sideconfigurationANTENNA POSITION 03AIR6449 n77700850TBD700850AWS1900700/850AISG 2.0ProtocolAISG 2.0Protocol1 23 4RET5 6 7 8 1 23 4RET64TX \ 64RX5 6 7 8RETANTENNA POSITION 5NNH4-65B-R6H4AWS/1900/WCSAWS/1900/WCSSFP28Comscope CBC78T-DS-43700 850ABC700 B144478CPRI/DCSFP37 A/B/C_2_F8 A/B/C_1DAB8504478CPRI/DCSFP7SFP32 A/B/C_1ABC700 B124478CPRI/DCSFP77 A/B/C_2_FD9 A/B/C_13 A/B/C_1CDABCAWS 3CPRI/DCDTO BBUTO BBUCPRI/DCSFP3CPRI/DCSFP31900700 850ABCDABWCSCDN005A_19A_19B_1 9C_18A_18A_2N005B_18B_18B_1N005C_18C_18C_22A_12B_1 2C_1To RRUSTNIDLA BA BABCDEFGHJKLMNPOTN C TN DSYNC SAULMT ECALARM1 2BBU6630Mixed#27A_17B_1 7C_1 7A_2_F 7B_2_F 7C_2_F3A_13B_1 3C_1To RRUSTNIDLA BA BABCDEFGHJKLMNPQTN C TN DSYNC SAULMT ECALARM1 2BBU6630#1Use IDL A connection forERANBaseband TN BPort connection toCSR for S1,O&MPort Definition:2 – AWS Band3 – WCS Band7 – 700 MHz Band8 – 850 MHz Band9 – 1900 MHz Band850 UMTSDigitally signed by Christopher Roberts Date: 2021.05.27 18:18:42 -04'00'PlanningAdministrative Approval08/02/2021 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 7705703/15/21CDRJWYC-31REVISION:SHEET NUMBER:1961 NORTHPOINT BLVD, SUITE 130HIXSON, TN 37343PH: 423-843-9500 / FAX: 423-843-9509SHEET TITLE:AT&T SITE NUMBER:DXL02813BU #: 876558F3- COPPELL MIDDLE S1301 WRANGLERCOPPELL, TX 75019EXISTING 71'-6" MONOPOLEISSUED FORCONSTRUCTION575 MOROSGO DRIVEATLANTA, GA 30324-3300TX FIRM NUMBER 2108713/15/21CDRJWYISSUED FORCONSTRUCTIONFINAL TOWER ELEVATION& ANTENNA PLANSDigitally signed by Christopher Roberts Date: 2021.05.27 18:18:53 -04'00'PlanningAdministrative Approval08/02/2021 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 7705703/15/21CDRJWYC-41REVISION:SHEET NUMBER:1961 NORTHPOINT BLVD, SUITE 130HIXSON, TN 37343PH: 423-843-9500 / FAX: 423-843-9509SHEET TITLE:AT&T SITE NUMBER:DXL02813BU #: 876558F3- COPPELL MIDDLE S1301 WRANGLERCOPPELL, TX 75019EXISTING 71'-6" MONOPOLEISSUED FORCONSTRUCTION575 MOROSGO DRIVEATLANTA, GA 30324-3300TX FIRM NUMBER 2108713/15/21CDRJWYISSUED FORCONSTRUCTIONEQUIPMENTDESCRIPTION TABLEDigitally signed by Christopher Roberts Date: 2021.05.27 18:19:12 -04'00'PlanningAdministrative Approval08/02/2021 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 7705703/15/21CDRJWYC-51REVISION:SHEET NUMBER:1961 NORTHPOINT BLVD, SUITE 130HIXSON, TN 37343PH: 423-843-9500 / FAX: 423-843-9509SHEET TITLE:AT&T SITE NUMBER:DXL02813BU #: 876558F3- COPPELL MIDDLE S1301 WRANGLERCOPPELL, TX 75019EXISTING 71'-6" MONOPOLEISSUED FORCONSTRUCTION575 MOROSGO DRIVEATLANTA, GA 30324-3300TX FIRM NUMBER 2108713/15/21CDRJWYISSUED FORCONSTRUCTIONDETAILSDigitally signed by Christopher Roberts Date: 2021.05.27 18:19:24 -04'00'PlanningAdministrative Approval08/02/2021 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 7705703/15/21CDRJWYC-6.11REVISION:SHEET NUMBER:1961 NORTHPOINT BLVD, SUITE 130HIXSON, TN 37343PH: 423-843-9500 / FAX: 423-843-9509SHEET TITLE:AT&T SITE NUMBER:DXL02813BU #: 876558F3- COPPELL MIDDLE S1301 WRANGLERCOPPELL, TX 75019EXISTING 71'-6" MONOPOLEISSUED FORCONSTRUCTION575 MOROSGO DRIVEATLANTA, GA 30324-3300TX FIRM NUMBER 2108713/15/21CDRJWYISSUED FORCONSTRUCTIONEQUIPMENT SPECSDigitally signed by Christopher Roberts Date: 2021.05.27 18:19:37 -04'00' IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 7705703/15/21CDRJWYC-6.21REVISION:SHEET NUMBER:1961 NORTHPOINT BLVD, SUITE 130HIXSON, TN 37343PH: 423-843-9500 / FAX: 423-843-9509SHEET TITLE:AT&T SITE NUMBER:DXL02813BU #: 876558F3- COPPELL MIDDLE S1301 WRANGLERCOPPELL, TX 75019EXISTING 71'-6" MONOPOLEISSUED FORCONSTRUCTION575 MOROSGO DRIVEATLANTA, GA 30324-3300TX FIRM NUMBER 2108713/15/21CDRJWYISSUED FORCONSTRUCTIONEQUIPMENT SPECSDigitally signed by Christopher Roberts Date: 2021.05.27 18:19:49 -04'00'PlanningAdministrative Approval08/02/2021 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 7705703/15/21CDRJWYG-11REVISION:SHEET NUMBER:1961 NORTHPOINT BLVD, SUITE 130HIXSON, TN 37343PH: 423-843-9500 / FAX: 423-843-9509SHEET TITLE:AT&T SITE NUMBER:DXL02813BU #: 876558F3- COPPELL MIDDLE S1301 WRANGLERCOPPELL, TX 75019EXISTING 71'-6" MONOPOLEISSUED FORCONSTRUCTION575 MOROSGO DRIVEATLANTA, GA 30324-3300TX FIRM NUMBER 2108713/15/21CDRJWYISSUED FORCONSTRUCTIONGROUNDING DETAILSDigitally signed by Christopher Roberts Date: 2021.05.27 18:20:01 -04'00'PlanningAdministrative Approval08/02/2021 IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 7705703/15/21CDRJWYG-21REVISION:SHEET NUMBER:1961 NORTHPOINT BLVD, SUITE 130HIXSON, TN 37343PH: 423-843-9500 / FAX: 423-843-9509SHEET TITLE:AT&T SITE NUMBER:DXL02813BU #: 876558F3- COPPELL MIDDLE S1301 WRANGLERCOPPELL, TX 75019EXISTING 71'-6" MONOPOLEISSUED FORCONSTRUCTION575 MOROSGO DRIVEATLANTA, GA 30324-3300TX FIRM NUMBER 2108713/15/21CDRJWYISSUED FORCONSTRUCTIONGROUNDING DETAILSDigitally signed by Christopher Roberts Date: 2021.05.27 18:20:14 -04'00'PlanningAdministrative Approval08/02/2021 SITE:876558 F3 - COPPELL MIDDLE S (10152317)REV.DATEDESCRIPTIONSITE INFORMATION:SITE NUMBER:DRAWN BY:CHECKED BY:DATE:SHEET TITLE:POD NUMBER:PLANS PREPARED BY:PLANS PREPARED FOR:CARRIER:DRAWING NOTICE:DOPPOWEROFDESIGN1033 E. TURKEYFOOT LAKE RD.SUITE 206 AKRON, OHIO 44312330-961-7432THESE DOCUMENTS ARE CONFIDENTIAL AND ARETHE SOLE PROPERTY OF CROWN CASTLE AND MAYNOT BE REPRODUCED, DISSEMINATED ORREDISTRIBUTED WITHOUT THE EXPRESS WRITTENCONSENT OF CROWN CASTLE.DESIGNED BY:POWER OF DESIGN GROUP, LLCF-16059T-01TITLE SHEET05/19/2021JGCTAJ21-824498765581301 WRANGLERCOPPELL, TX 75019F3 - COPPELL MIDDLE S(10152317)MODIFICATION DRAWINGDPPROJECT INFORMATIONSCOPE OF WORK:MOUNT MODIFICATION DRAWINGS INCLUDES:REMOVE EXISTING STABILIZER KIT & TOP SUPPORT RAIL.INSTALL PROPOSED STABILIZER KIT.COUNTY:DALLASSITE ADDRESS: 1301 WRANGLERCOPPELL, TX 75019LATITUDE:32° 56' 5.32"LONGITUDE:-97° 0' 5.83"MODIFICATION DRAWING FOR AN EXISTING 12.58' PLATFORM W/ SUPPORT RAILS AT 45.71' ON A 71.5' MONOPOLE TOWERSHEET INDEXT-01 TITLE SHEETN-01 NOTESS-01 PLAN VIEWS-02 ELEVATION VIEWMI-01 MODIFICATION CHECKLIST REV.DATEDESCRIPTIONSITE INFORMATION:SITE NUMBER:DRAWN BY:CHECKED BY:DATE:SHEET TITLE:POD NUMBER:PLANS PREPARED BY:PLANS PREPARED FOR:CARRIER:DRAWING NOTICE:DOPPOWEROFDESIGN1033 E. TURKEYFOOT LAKE RD.SUITE 206 AKRON, OHIO 44312330-961-7432THESE DOCUMENTS ARE CONFIDENTIAL AND ARETHE SOLE PROPERTY OF CROWN CASTLE AND MAYNOT BE REPRODUCED, DISSEMINATED ORREDISTRIBUTED WITHOUT THE EXPRESS WRITTENCONSENT OF CROWN CASTLE.DESIGNED BY:POWER OF DESIGN GROUP, LLCF-16059S-01PLAN VIEW05/19/2021JGCTAJ21-824498765581301 WRANGLERCOPPELL, TX 75019F3 - COPPELL MIDDLE S(10152317)MODIFICATION DRAWINGDPPLAN VIEW 1/2" = 1'-0"NOTES:·ANTENNAE & GRATING NOT SHOWN FOR CLARITY·ALL FIELD DRILLED HOLES SHALL BE SOLVENT CLEANED AND TOUCHED UP WITH TWO COATS OF ZRC RICH PAINT·EXCESS MATERIALS SHALL BE REMOVED AND DISPOSED OFF SITE BY THE CONTRACTOR6'-7" (TYP.)2'-8" (TYP.)3'-3" (TYP.)PROPOSED STABILIZER KIT, SITEPRO1 P/N: PRK-SFS-L(F.V. LENGTH & TRIM ARMS AS NEEDED) (PROPOSEDCOLLAR MOUNT SHALL BE INSTALLED AT THE SAMELOCATION AS EXISTING STABILIZER KIT TO BE REMOVED)EXISTING STABILIZER KIT TO BE REMOVED & DISPOSEDOFFSITE BY THE CONTRACTOREXISTING SUPPORT RAIL TO BE REMOVED &DISPOSED OFFSITE BY THE CONTRACTOR (TYP.)EXISTING MONOPOLE TOWEREXISTING MOUNT PIPE (TYP.)EXISTING SUPPORT RAIL (TYP.)EXISTING FACE MEMBER (TYP.)PlanningAdministrative Approval08/02/2021 REV.DATEDESCRIPTIONSITE INFORMATION:SITE NUMBER:DRAWN BY:CHECKED BY:DATE:SHEET TITLE:POD NUMBER:PLANS PREPARED BY:PLANS PREPARED FOR:CARRIER:DRAWING NOTICE:DOPPOWEROFDESIGN1033 E. TURKEYFOOT LAKE RD.SUITE 206 AKRON, OHIO 44312330-961-7432THESE DOCUMENTS ARE CONFIDENTIAL AND ARETHE SOLE PROPERTY OF CROWN CASTLE AND MAYNOT BE REPRODUCED, DISSEMINATED ORREDISTRIBUTED WITHOUT THE EXPRESS WRITTENCONSENT OF CROWN CASTLE.DESIGNED BY:POWER OF DESIGN GROUP, LLCF-16059S-02ELEVATION VIEW05/19/2021JGCTAJ21-824498765581301 WRANGLERCOPPELL, TX 75019F3 - COPPELL MIDDLE S(10152317)MODIFICATION DRAWINGDPELEVATION VIEW 1/2" = 1'-0"NOTES:·ANTENNAE & GRATING NOT SHOWN FOR CLARITY·ALL FIELD DRILLED HOLES SHALL BE SOLVENT CLEANED AND TOUCHED UP WITH TWO COATS OF ZRC RICH PAINT·EXCESS MATERIALS SHALL BE REMOVED AND DISPOSED OFF SITE BY THE CONTRACTORPROPOSED STABILIZER KIT, SITEPRO1 P/N: PRK-SFS-L(F.V. LENGTH & TRIM ARMS AS NEEDED) (PROPOSEDCOLLAR MOUNT SHALL BE INSTALLED AT THE SAMELOCATION AS EXISTING STABILIZER KIT TO BE REMOVED)EXISTING STABILIZER KIT TO BE REMOVED & DISPOSEDOFFSITE BY THE CONTRACTOREXISTING SUPPORT RAIL TO BE REMOVED &DISPOSED OFFSITE BY THE CONTRACTOR (TYP.)EXISTING MONOPOLE TOWEREXISTING MOUNT PIPE (TYP.)EXISTING SUPPORT RAIL (TYP.)EXISTING FACE MEMBER (TYP.)6'-2" (± F.V. LENGTH)PROPOSED COLLAR ATTACHMENT SHALLREPLACE EXISTING COLLAR AT THE EXACTSAME LOCATIONPlanningAdministrative Approval08/02/2021 REV.DATEDESCRIPTIONSITE INFORMATION:SITE NUMBER:DRAWN BY:CHECKED BY:DATE:SHEET TITLE:POD NUMBER:PLANS PREPARED BY:PLANS PREPARED FOR:CARRIER:DRAWING NOTICE:DOPPOWEROFDESIGN1033 E. TURKEYFOOT LAKE RD.SUITE 206 AKRON, OHIO 44312330-961-7432THESE DOCUMENTS ARE CONFIDENTIAL AND ARETHE SOLE PROPERTY OF CROWN CASTLE AND MAYNOT BE REPRODUCED, DISSEMINATED ORREDISTRIBUTED WITHOUT THE EXPRESS WRITTENCONSENT OF CROWN CASTLE.DESIGNED BY:POWER OF DESIGN GROUP, LLCF-16059MI-01MODIFICATIONCHECKLIST05/19/2021JGCTAJ21-824498765581301 WRANGLERCOPPELL, TX 75019F3 - COPPELL MIDDLE S(10152317)MODIFICATION DRAWINGDPMODIFICATION INSPECTION CHECKLISTBEFORE CONSTRUCTIONDURING CONSTRUCTIONAFTER CONSTRUCTIONCONSTRUCTION/INSTALLATION INSPECTIONAND TESTING REQUIRED (COMPLETED BYENGINEER OF RECORD)REPORT ITEMCONSTRUCTION/INSTALLATION INSPECTIONAND TESTING REQUIRED (COMPLETED BYENGINEER OF RECORD)REPORT ITEMCONSTRUCTION/INSTALLATION INSPECTIONAND TESTING REQUIRED (COMPLETED BYENGINEER OF RECORD)REPORT ITEMXMODIFICATION INSPECTION CHECKLIST DWGXCONSTRUCTION INSPECTION (AS REQUIREDBY CROWN)XMODIFICATION INSPECTOR REDLINE ORRECORD DRAWING(S)-ENGINEER OF RECORD APPROVED SHOPDRAWINGS-FOUNDATION INSPECTION-POST INSTALLED ANCHOR ROD PULL-OUTTESTING-FABRICATION INSPECTION-CONCRETE COMP. STRENGTH AND SLUMPTESTXPHOTOGRAPHSXMATERIAL TEST REPORT-POST INSTALLED ANCHOR ROD VERIFICATIONADDITIONAL TESTING AND INSPECTION-FABRICATOR NDE INSPECTION-BASE PLATE GROUT VERIFICATION-NDE REPORT OF MONOPOLE BASEPLATE (ASREQUIRED )-THIRD PARTY CERTIFIED WELD INSPECTIONXPACKING SLIP-EARTHWORK LIFT AND DENSITY (REPORTREQUIRED)ADDITIONAL TESTING AND INSPECTIONXON SITE COLD GALVANIZING VERIFICATION-GUY WIRE TENSION REPORTXGC AS-BUILT DOCUMENTSADDITIONAL TESTING AND INSPECTION (AS REQUIRED BY CROWN)MODIFICATION INSPECTION NOTES:GENERAL:1. THE MODIFICATION INSPECTION IS A VISUAL INSPECTION OF TOWERMODIFICATION AND A REVIEW OF CONSTRUCTION INSPECTION AND OTHERREPORTS TO ENSURE THE INSTALLATION WAS CONSTRUCTED IN ACCORDANCEWITH THE CONTRACT DOCUMENTS. NAMELY THE MODIFICATION DRAWINGS., ASDESIGNED BY THE ENGINEER OF RECORD.2. THE MODIFICATION INSPECTION IS TO CONFIRM INSTALLATION CONFIGURATIONAND WORKMANSHIP ONLY AN IS NOT A REVIEW OF THE MODIFICATION DESIGNITSELF. NOR DOES THE MODIFICATION INSPECTOR TAKE OWNERSHIP OF THEMODIFICATION DESIGN. OWNERSHIP OF THE STRUCTURAL MODIFICATION DESIGNEFFECTIVENESS AND INTENT RESIDES WITH THE ENGINEER OF RECORD AT ALLTIMES.3. TO ENSURE THAT THE REQUIREMENT OF THE MODIFICATION INSPECTION AREMET, IT IS VITAL THAT THE GENERAL CONTRACTOR (GC) AND THE MODIFICATIONINSPECTOR BEGIN COMMUNICATION AND COORDINATING AS SOON AS A PO ORPAYMENT IS RECEIVED. IT IS EXPECTED THAT EACH PARTY WILL BE PROACTIVE INREACHING OUT TO THE OTHER PARTY.MODIFICATION INSPECTOR:1. THE MODIFICATION INSPECTOR IS REQUIRED TO CONTACT THE GC AS SOON ASRECEIVING A PO OR PAYMENT FOR THE MODIFICATION INSPECTION TO:·REVIEW THE REQUIREMENT OF THE MODIFICATION INSPECTION CHECKLIST·WORK WITH THE GC TO DEVELOP A SCHEDULE TO CONDUCT ON-SITE·INSPECTIONS·DISCUSS ANY SITE SPECIFIC INSPECTIONS OR CONCERNS2. THE MODIFICATION INSPECTOR IS RESPONSIBLE FOR COLLECTING ALL GENERALCONTRACTOR (GC) INSPECTION AND TEST REPORTS. REVIEWING THE DOCUMENTSFOR ADHERENCE TO THE CONTRACT DOCUMENTS, CONDUCTING THE INXFEILDINSPECTIONS, AND SUBMITTING THE MODIFICATION INSPECTION REPORT.GENERAL CONTRACTOR:1. THE GC IS REQUIRED TO CONTACT THE MODIFICATION INSPECTOR AS SOON ASRECEIVING A PO OR PAYMENT FOR THE MODIFICATION INSTALLATION ORTURNKEY PROJECT TO:·REVIEW THE REQUIREMENT OF THE MODIFICATION INSPECTION CHECKLIST·WORK WITH THE MI INSPECTOR TO DEVELOP A SCHEDULE TO CONDUCTON-SITE MODIFICATION INSPECTIONS, INCLUDING FOUNDATION INSPECTIONS·BETTER UNDERSTAND ALL INSPECTION AND TESTING REQUIREMENTS2. THE GC SHALL PERFORM AND RECORD THE TEST AND INSPECTION RESULTS INACCORDANCE WITH THE REQUIREMENTS OF THE MODIFICATION INSPECTIONCHECKLIST.RECOMMENDATIONS:1. IT IS SUGGESTED THAT THE GC PROVIDE A MINIMUM OF 5 BUSINESS DAYS NOTICE, TO THE MODIFICATION INSPECTOR AS TO WHEN THE SITE WILL BE READY FOR HE MODIFICATION INSPECTION TO BE CONDUCTED.·THE GC AND MODIFICATION INSPECTION COORDINATE CLOSELY THROUGHOUT THE ENTIRE PROJECT.·WHEN POSSIBLE IT IS PREFERRED TO HAVE THE MODIFICATION INSPECTOR AND GC ON-SITE SIMULTANEOUSLY FOR ANY GUY WIRE TENSIONING OR REXTENSIONING OPERATIONS.·IT MAY BE BENEFICIAL TO INSTALL ALL TOWER MODIFICATIONS PRIOR TO CONDUCTING THE FOUNDATION INSPECTION TO ALLOW FOUNDATION AND MODIFICATION INSPECTION(S) DONE IN ONE SITE VISIT.·WHEN POSSIBLE, IT IS PREFERRED TO HAVE THE GC AND MODIFICATIONINSPECTOR ON-SITE DURING THE MODIFICATION INSPECTION. THEREFORE, THE GC MAY CHOOSE TO COORDINATE THE MODIFICATION INSPECTION CAREFULLYTO ENSURE ALL CONSTRUCTION FACILITIES AT THEIR DISPOSAL WHEN THE MI INSPECTOR IS ON SITE.CANCELLATION OR DELAYS IN SCHEDULED MODIFICATION INSPECTION:1. IF THE GC AND MODIFICATION INSPECTOR AGREE TO A DATE ON WHICH THEMODIFICATION INSPECTION WILL BE CONDUCTED, AND EITHER ARTY CANCELS ORDELAYS, THE TOWER OWNER SHALL NOT BE RESPONSIBLE FOR ANY COSTS, FEES,LOSS OR DEPOSITS AND/OR OTHER PENALTIES RELATE TO THE CANCELLATION ORDELAY INCURRED BY EITHER PARTY FOR ANY TIME. EXCEPTIONS MAY BE MADE INTHE DELAY/ CANCELLATION IS CAUSED BY WEATHER OR OTHER CONDITIONS THATMAY COMPROMISE THE SAFETY OF THE PARTIES INVOLVED.CORRECTION OF FAILING MODIFICATION INSPECTION:1. IF THE MODIFICATION INSTALLATION WOULD FAIL THE MODIFICATIONINSPECTION ("FAILED MODIFICATION INSPECTION"), THE GC SHALL WORK WITHMODIFICATION INSPECTOR TO COORDINATE A REMEDIATION PLAN IN ONE OFTWO WAYS:·CORRECT FAILING ISSUES TO COMPLY WITH THE SPECIFICATIONS CONTAINED IN THE ORIGINAL CONTRACT DOCUMENTS AND COORDINATE A SUPPLEMENT MODIFICATION INSPECTION. OR, WITH TOWER OWNER'S APPROVAL, THE GC MAY WORK WITH THE ENGINEER OF RECORD TO REXANALYZE THE MODIFCATION/REINFORCEMENT USING AS-BUILT CONDITION.VERIFICATION INSPECTIONS:1. TOWER OWNER RESERVES THE RIGHT TO CONDUCT A VERIFICATION INSPECTIONTO VERIFY THE ACCURACY AND COMPLETENESS OF PREVIOUSLY COMPLETEDMODIFICATION AND INSPECTION(S) ON TOWER MODIFICATION PRODUCTS.2. VERIFICATION INSPECTION MAY BE CONDUCTED BY AN INDEPENDENT FIRM AFTERA MODIFICATION PROJECT IS COMPLETED, AS MARKED BY THE DATE OF ANACCEPTED “PASSING MODIFICATION INSPECTION MODIFICATION INSPECTION"REPORT FOR THE ORIGINAL PROJECT.REQUIRED PHOTOS:1. BETWEEN THE GC AND THE MI INSPECTOR THE FOLLOWING PHOTOGRAPHS ARETO BE TAKEN AND INCLUDED IN THE MODIFICATION INSPECTION REPORT:·PREXCONSTRUCTION GENERAL SITE CONDITION·PHOTOGRAPHS DURING THE REINFORCEMENT MODIFICATION CONSTRUCTION/ERECTION AND INSPECTION··RAW MATERIALS··PHOTOS OF ALL CRITICAL DETAILS··WELD PREPARATION··FOUNDATION MODIFICATION··BOLT INSTALLATION AND TORQUE··FINAL INSTALLED CONDITION··SURFACE COATING REPAIR·POST CONDITION PHOTOGRAPHS·FINAL INFIELD CONDITION ANY OTHER PHOTOS DEEMED RELEVANT TO SHOWCOMPLETE DENTALS OF MODIFICATIONS2. PHOTOS OF ELEVATED MODIFICATIONS TAKEN FROM THE GROUND SHALL BECONSIDERED INADEQUATE.PlanningAdministrative Approval08/02/2021