Loading...
DXL06116_839836_10003358_541353_COPPELL_(S_ROYAL_LN)_ATT_PRIORITY_Final_CD_Rev.1_08.25.2021ADMAPPAT&T SITE NUMBER: AT&T SITE NAME: AT&T FA CODE: AT&T PACE NUMBER: SITE TYPE: SITE INFORMATION CROWN CASTLE USA INC. COPPELL (S ROYAL LN) SITE NAME: SITE ADDRESS: 160 SOUTH ROYAL LANE COPPELL, TX 75019 COUNTY: DALLAS MAP/PARCEL #: 18000040OAl CR0000 AREA OF CONSTRUCTION: EXISTING LATITUDE: 32° 58' 10.36" LONGITUDE: -97° 1' 22.25" LAT/LONG TYPE: NAD83 GROUND ELEVATION: 524 FT. CURRENT ZONING: LIGHT INDUSTRIAL JURISDICTION: CITY OF COPPELL, TX OCCUPANCY CLASSIFICATION: U TYPE OF CONSTRUCTION: IIB A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION PROPERTY OWNER LIBERTY PROPERTY LP PROLOGIS LP 1800 WAZEE ST STE 500 DENVER, CO 80202 TOWER OWNER CROWN CASTLE USA, INC. 1220 AUGUSTA DRIVE HOUSTON, TX 77057 CARRIER/APPLICANT: AT&T TOWER ASSET GROUP 1801 VALLEY VIEW LANE FARMERS BRANCH, TX 75234 ELECTRIC PROVIDER: ONCOR 888-212-6862 TELCO PROVIDER: AT&T 800-818-3132 PROJECT TEAM A&E FIRM: CROWN CASTLE USA INC. 2000 CORPORATE DRIVE CANONSBURG, PA 15317 CRO WNAE.APPROVAL@CRO WNCASTLE. COM CROWN CASTLE 1220 AUGUSTA DRIVE, SUITE 500 USA INC. DISTRICT HOUSTON, TX 77057 CONTACTS: BARCLAY HAWLEY-PROJECT MANAGER TBD JOE MCCALL - CONSTRUCTION MANAGER TBD at&t DXL06116 COPPELL (S ROYAL LN) 10003358 MRNTX069348 MONOPOLE BUSINESS UNIT #: SITE ADDRESS: COUNTY: TOWER HEIGHT: PROJECT: AT&T PRIORITY DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET T-2 GENERAL NOTES C-1 SITE PLAN C-1.1 PLUMBING DIAGRAM C-2 TOWER ELEVATION & ANTENNA PLANS C-3 EQUIPMENT DESCRIPTION TABLE C-4 DETAILS C-5 EQUIPMENT SPECS C-5.1 EQUIPMENT SPECS G-1 GROUNDING SCHEMATIC G-2 GROUNDING DETAILS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11X17. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. PROJECT DESCRIPTION THE PURPOSE OF THIS PROJECT IS TO PROPOSE AN ANTENNA MODIFICATION ON AN EXISTING WIRELESS SITE. FINAL TOWER CONFIGURATION: • (11) ANTENNAS • (12) RRUs • (3) DIPLEXERS • (4) RAYCAP J-BOXES • (6) 7/8" COAX • (3) 3/8" FIBER • (2) 13/16" DC POWER • (4) 3/4" DC POWER • (2) 7/8" DC POWER • (2) 3/8" RET FINAL GROUND CONFIGURATION: • NO CHANGES DESIGN PACKAGE BASED ON THE RFDS REVISION: ---- DATE: ---- DESIGN PACKAGE BASED ON THE APPLICATION ID:541353 REVISION: 0 839836 160 SOUTH ROYAL LANE COPPELL, TX 75019 DALLAS 95.51 m LOCATION MAP ... / J.., FloWnrM Enterprise Or_. ... ................ ........ '.,... - .... Rneking5} 3 ,�PHrK Rockladgw Park-•. GraPevin r��� Ir4 `r' CD. A :+�f:' - F'm, q nlyO r�d J C mmungY -''I SITE ID: DXLObI Ib -o-_ �� ,yam lyy �F�rlt-vYesi LAT.32-58'10.36" -�1 __ ..' � W�.-1 alvd -„ LONG: -97° 1' 22.25" "Co pelt w S / Go ypo •2• o JJIL ` 6 L] 'ark valley Or O o E Sandy Lake Rri GraAavine -� uvnHer26 % n wneel O Lake - Pdr w Bon wM1ee1 -� Park 6 Ruby Rd� +� whlspe'...... _. f �� ...ew-Dr Cooper Ln m F m � ssn rin4- 9ilvnr _ Hunter W d Pgµc, O �``-ay•L l_akY Park w Bethel Rd -. so bums St a ..,_...� .'1ow_a�,nl .- 3BA -------- �'()�(,1LE DRIVING DIRECTIONS FROM NEAREST DALLAS/FORTH WORTH INTERNATIONAL AIRPORT [2400 AVIATION DR, DFW AIRPORT, TX 75261] TAKE ACCESS RD TO INTERNATIONAL SERVICE RD/S SERVICE RD CONTINUE ON INTERNATIONAL SERVICE RD/S SERVICE RD. TAKE INTERNATIONAL PKWY, TX-121 N AND FRONTAGE RD TO NORTHPOINT DR CONTINUE ON NORTHPOINT DR TO YOUR DESTINATION APPLICABLE CODES ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING 2015IBC MECHANICAL 2015IMC ELECTRICAL 2014 NEC NOTE: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER REFERENCE DOCUMENTS: STRUCTURAL ANALYSIS: BY OTHERS DATED: MOUNT ANALYSIS: INFINIGY DATED: 05/13/2021 CALL TEXAS ONE CALL o © (L3 DIGNGD CALL 3 WORKING DAYS BEFORE YOU DIGI kz� ate 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CCCROWN CASTLE 9041 RIVER ROAD, SUITE 421 INDIANAPOLIS, IN 46240 PVm P. MARSHALL & ASSOCIATES 6801 PORTWEST DR. STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 kT&T SITE NUMBER: BU #: 839836 COPPELL (S ROYAL LN) 160 SOUTH ROYAL LANE COPPELL, TX 75019 EXISTING 95.51 MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA 0 4/8/2021 DAD FINALS SA 1 05/25/2021 DAD MA UPDATED SA W. .................................... 124679 Illo .� CENS���,_�� FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 21 CA6M-162 SHEET NUMBER: REVISION: T-1 1 1 CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS: (_FNIFJAI NInTFC- ELECTRICAL INSTALLATION NOTES: I. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE TO PROCEED NIP AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN CASTLE USA INC. NOC AT 800-788-7011 & THE CROWN CASTLE USA INC. CONSTRUCTION MANAGER. 2. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED Q ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL REQUIREMENTS. 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION): FEDERAL, STATE, AND LOCAL REGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND CROWN CASTLE USA INC. STANDARD CED-STD-10253, INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSIR IA-322 LATEST EDITION). 5. ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWN CASTLE USA INC. TOWER SITE" AND LATEST VERSION OF ANSI IA-1019-A-2012 "STANDARD FOR INSTALLATION ALTERATION, , AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS:' 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY PROCEDURES. 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATEST APPROVED REVISION. 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, TOWER OWNER, CROWN CASTLE USA INC., AND/OR LOCAL UTILITIES. 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. GREENFIELD GROUNDING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER: AT&T TOWER OWNER: CROWN CASTLE USA INC. 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY. 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 6. PRIOR TO THE SUBMISSION OF BIDS THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CROWN CASTLE. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. S. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC. 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. CONCRETE, FOUNDATIONS, AND REINFORCING STEEL: 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM Al 84, ASTM Al85 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE. 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 psf. 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90°f AT TIME OF PLACEMENT. 4. CONCRETE EXPOSED TO FREEZE -THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR ENTRAINMENT TO BE BASED ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A MAXIMUM WATER -TO -CEMENT RATIO (W/C) OF 0.45. 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC(WWF) SHALL CONFORM TO ASTM A185. ALL SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, UNLESS NOTED OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: #4 BARS AND SMALLER 40 ksi #5 BARS AND LARGER 60 ksi 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" CONCRETE EXPOSED TO EARTH OR WEATHER: #6 BARS AND LARGER 2" #5 BARS AND SMALLER- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-T/2" - - - CONCRETE NOT EXPOSED TO EARTH OR WEATHER-- - - - - - - - - - - - - - - - - - - - - - - - - SLAB AND WALLS 3/4' BEAMS AND COLUMNS 1-1/2" 7. A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 450 BENDS CAN BE ADEQUATELY SUPPORTED. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. BOND ALL METALLIC OBJECTS WITHIN 6 It OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/C NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3' TO 6" OF CAD -WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2' PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL) . THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S). 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. S. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR, TYPE SCOW CORD (#14 OR LARGER) UNLESS OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR TYPE TC CABLE #14 OR LARGER WITH TYPE THHW THWN THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BIETTS (OR EQUAL'. LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75° C (90° C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90S AND ALL APPROVED ABOVE GRADE PVC CONDUIT. 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, ILL, ANSI/IEEE AND THE NEC. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i.e. POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY COATED OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "AT&T". 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. CONDUCTOR COLOR CODE SYSTEM CONDUCTOR COLOR 120/240V, 10 A PHASE BLACK B PHASE RED NEUTRAL WHITE GROUND GREEN 120/208V, 30 A PHASE BLACK B PHASE I RED C PHASE BLUE NEUTRAL WHITE GROUND GREEN 277/480V, 30 A PHASE BROWN B PHASE ORANGE OR PURPLE C PHASE YELLOW NEUTRAL GREY GROUND GREEN DC VOLTAGE POS (+J RED** NEG (-) BLACK** `Jtt Nt LIU F_j I11ANUIL1 ** POLARITY MARKED AT TERMINATION ABBREVIATIONS: ANT ANTENNA (E) EXISTING FIF FACILITY INTERFACE FRAME GEN GENERATOR GPS GLOBAL POSITIONING SYSTEM GSM GLOBAL SYSTEM FOR MOBILE LIE LONG TERM EVOLUTION MGB MASTER GROUND BAR MW MICROWAVE (N) NEW NEC NATIONAL ELECTRIC CODE (P) PROPOSED PP POWER PLANT QTY QUANTITY RECT RECTIFIER RBS RADIO BASE STATION RET REMOTE ELECTRIC TILT RFDS RADIO FREQUENCY DATA SHEET RRH REMOTE RADIO HEAD RRU REMOTE RADIO UNIT SAID SMART INTEGRATED DEVICE TMA TOWER MOUNTED AMPLIFIER TYP TYPICAL UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM W.P. WORK POINT APWA UNIFORM COLOR CODE: WHITE PROPOSED EXCAVATION ® TEMPORARY SURVEY MARKINGS ELECTRIC POWER LINES, CABLES, CONDUIT, AND LIGHTING CABLES YELLOW GAS, OIL, STEAM, PETROLEUM, OR GASEOUS MATERIALS COMMUNICATION, ALARM OR SIGNAL LINES, CABLES, OR CONDUIT AND TRAFFIC LOOPS ® POTABLE WATER RECLAIMED WATER, IRRIGATION, AND SLURRY LINES ® SEWERS AND DRAIN LINES t&t V 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CCCASCROWN TLE v 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 D 0 O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR. STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T&T SITE NUMBER: BU #: 839836 COPPELL (S ROYAL LN) 160 SOUTH ROYAL LANE COPPELL, TX 75019 EXISTING 95.51 MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 4/8/2021 DAD FINALS SA 1 05/25/2021 DAD MA UPDATED SA STEVE S. LEE ............................... 124679 CENS �%. )NAB_ FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, l TO ALTER THIS DOCUMENT. J Planning Admwist ailve Approval 21 CA6M-162 COPPELL SHEET NUMBER: REVISION: 26�� 10//2021 T-2 1 SITE PLAN DISCLAIMER: PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROM PREVIOUS PLAN SETS OR FROM CCISITES. PM&A HAS NOT COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIMS AS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET. CONTRACTOR SHALL FIELD VERIFY SITE PLAN & EQUIPMENT SHOWN AGAINST PRESENT FIELD CONDITIONS. IF PLANS DO NOT MATCH UP WITH SITE CONDITION AT TIME OF CONSTRUCTION, CONTACT AT&T AND THE CROWN CASTLE CM. 57,_D" f SITE PLAN � SCALE: 3/4-1 -0" FULL SIZE) N l' 6" 0 1' 3/8"=1'-0" (11.17) Planning Admini.,.I a Approval COPPELL 10/26/2021 at&t 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CCCROWN CASTLE 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR. STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T&T SITE NUMBER: BU #: 839836 COPPELL (S ROYAL LN) 160 SOUTH ROYAL LANE COPPELL, TX 75019 EXISTING 95.51 MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 4/8/2021 DAD FINALS SA 1 05/25/2021 DAD MA UPDATED SA F I/ *' 1001v *�S STEVE..S....LEE. .... 124679 �; FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 21 CA6M-162 SHEET NUMBER: REVISION: C-1 1 ANTENNA POSITKtJ 1 ANTENW F)STTTON 03 ANTENW POSfTlON 5 NNHH-65B-P: AI136:d9 n77 hiNHd-65ES?H93H4 :.. ,.,.t N_r_. r,:r d_-tale-d ratio to artenro m-r� refer to the IzVest AX ArItEnrwR3do Part Ghnrtetars Feld Nolca IRF-I.-W201&2&5j ad tt* 4T SYi-rig PLv�mk Pod Oe mi6om 2 —AM Band 3 — WICS Band 7 —700 IIAHlz Bad 8 — 850 M AZ sad 9 — im NFt Bard ng05— aW NR Band Nil — a5 GiHHz Band Baseb.ind TN B Use IDL A connection for Port connection to ERAN CSR for S1,O&M 701I 50 AWS119DDNVCS ASYra119 L: !? It7 n lJ:- L? .ri Ln If7 + I Y I I y I } 1 } 1 SFP7 � Ara,c_t � a l nOQS' ] 444ads sw s a_n C�El F-:] 0n= I F I n n u u u El BBU 5216 #1 TYPICAL PLUMBING DIAGRAM �JSCALE: NOT TO SCALE nrlm. A B L u 4MCS wo RHUS-32 at&t 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CCCROWN CASTLE 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 F 1p I O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR. STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 AT&T SITE NUMBER: BU #: 839836 COPPELL (S ROYAL LN) 160 SOUTH ROYAL LANE COPPELL, TX 75019 EXISTING 95.51 MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 4/8/2021 DAD FINALS SA 1 05/25/2021 DAD MA UPDATED SA ... .................. ........... .. sTE�......... LEE...:.. 1 24679 yo .��CENS�O•:\��� /ONAL FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 21 CA6M-162 Planning Atlminislrative Approval COPPELL SHEET NUMBER: REVISION: iazs�zozi NOTE: NOTE: THE TOWER DRAWING IS ONLY DIRECT TOWER MOUNTED EQUIPMENT GRAPHIC REPRESENTATION OF THE MUST NOT TRAP OR INTERFERE WITH STRUCTURE. THE ACTUAL TOWER IN THE FIELD CLIMBING PEGS/STEPS AND SAFETY MAY VARY CLIMB. DO NOT OBSTRUCT BEACON IF TOWER LIT. (E) AT&T RAYCAP DC6-48-6 IOTA TO REMAIN (3 TOTAL) (E) & (P) AT&T TOWER TOP EQUIPMENT, SEE PLAN AT RIGHT FOR DETAILS. (E) AT&T ANTENNA TO REMAIN ¢ � (E) AT&T ANTENNA TO BE REMOVED COMMSCOPE NNHH-65B-R4 COMMSCOPESBNHH-1D65B AT&T RAD CENTER h (3 TOTAL, 1 PER SECTOR) Q Q (3 TOTAL, 1 PER SECTOR) HAI ELEV. = 98'-0" A.G.L. AT&T EQUIPMENT (P) AT&T 3-SECTOR MOUNT ANTENNA CL: 98'-0" SITE PRO 1 / VFA12-M3-WLL rmOUNT CL: 98'-0' (3 TOTAL, 1 PER SECTOR) (PER MOUNT ANALYSIS) ANY AND ALL TOWER MOUNTED EQUIPMENT MUST NOT TRAP OR INTERFERE W/ (E) CARRIER TOWER EXISTING SAFETY CLIMB EQUIPMENT (TYP.) r 0 (E) 95.5' MONOPOLE TOWER 0 (E) & (P) AT&T CABLES (6) 7/9' COAx (3J 3/8" FIBER (2) 13/16' DC POWER (4) 3/4" DC POWER (2J 7/8" DC POWER (2) 3/9 RET ROUTED UP TOWER TO ANTENNA PER STRUCTURAL ANALYSIS NOTES: I. PM&A HAS NOT PERFORMED A STRUCTURAL ANALYSIS OF THE EXISTING TOWER OR PROPOSED ANTENNA MOUNT. REFERTO STRUCTURAL ANALYSIS OR STRUCTURAL LETTER BY [TBD). DATED [TBD). PROJECT If [TBD]. NO NEW ANTENNAS OR EQUIPMENT INSTALLED WITHOUT APPROVAL OF STRUCTURAL ENGINEER AND CROWN CASTLE. 2. IF THE TOWER STRUCTURAL ANALYSIS SHOWS THE NEED FOR TOWER REINFORCEMENT, REFER TO TOWER REINFORCEMENT DESIGN PRIOR TO THE INSTALLATION OF ANY PROPOSED EQUIPMENT. 3. REFER TO TOWER STRUCTURAL ANALYSIS FOR PROPOSED ANTENNA CABLE ROUTING AND ATTACHMENT DETAILS. 4. TOWER ELEVATION SHOWN IS NOT DRAWN TO SCALE AND IS INTENDED ONLY FOR REFERENCE PURPOSES. REFER TO ORIGINAL TOWER DESIGN FOR ADDITIONAL INFORMATION. ��TOWER ELEVATION SCALE: NOT TO SCALE (E) AT&T ANTENNA TO BE REMOVED COMMSCOPE NNHH-65B-R4 (3 TOTAL, 1 PER SECTOR) (E) AT&T RRUS TO REMAIN ERICSSON RRUS-8843 B2/B66A (3 TOTAL, 1 PER SECTOR) (E) AT&T RRUS TO REMAIN ERICSSON RRUS-4449 35/1312 (3 TOTAL, 1 PER SECTOR) (E) AT&T RRUS TO REMAIN \\00\pOUo\00\\U TOTAL, SECTOR) AT&T• a PLATFORM MOUNTTO BE REMOVED (3 TOTAL, 1 PER SECTOR) (E) AT&T ANTENNA TO REMAIN CCI ANTENNAS / HBSA-M65R-KU-H6 (2 TOTAL, 1 PER BETA & GAMMA SECTOR) /-- EXISTING ANTENNA PLAN �JSCALE: NOT TO SCALE N (E) AT&T ANTENNA COMMSCOPE NNHH-65B-R4 (3 TOTAL, 1 PER SECTOR) (P) AT&T DIPLEXERS COMMSCOPE CBC78T-DS-43_CCIV2 (3 TOTAL, 1 PER SECTOR) (E) AT&T RELOCATED RRUS ERICSSON RRU"2 B30 (3 TOTAL, I PER SECTOR) (E) AT&T RRUS ERICSSON RRUS-4449 B5/B12 (3 TOTAL, 1 PER SECTOR] (E) AT&T RAYCAP DC6-48-60-18-8 (3 TOTAI Gp, �2Ay . (P) AT&T ANTENNA ERICSSON AIR 6449 B77D (3 TOTAL. I PER SECTOR) (P) AT&T 3-SECTOR MOUNT SITE PRO I / VFA I2-M3-WLL (3 TOTAL, I PER SECTOR) PER MOUNT ANALYSIS) (P) AT&T ANTENNA COMMSCOPE NNH465B-R6H4 (3 TOTAL, I PER SECTOR) (E) AT&T RRUS ERICSSON RRUS-8843 B2/B66A (3 TOTAL, 1 PER SECTOR) (E) AT&T RRUS ERICSSON RRUS-4478 914 (3 TOTAL, 1 PER SECTOR) PAT&T RAYCAP DC6-48-60-1 &-8C-EV TOTAL) AT&T ANTENNA CCI ANTENNAS / HBSA-M65R-KU-H6 (2 TOTAL, 1 PER BETA & GAMMA SECTOR) �z� FINAL ANTENNA PLAN �`�JSCALE: NOT TO SCALE N NOTE: NEW EQUIPMENT CANNOT BE MOUNTED TO TOWER. RELOCATE EXISTING TOWER MOUNTED EQUIPMENTTO CUSTOMER MOUNT. TOWER & ANTENNA STANDARD NOTES: A. DIRECT TOWER MOUNTED EQUIPMENT MUST NOT TRAP OR INTERFERE W/ CLIMBING PEGS/STEPS AND SAFETY CLIMB. B. NEW EQUIPMENT CANNOT BE MOUNTED DIRECTLY TO TOWER. NEW EQUIPMENT MUST BE MOUNTED TO CUSTOMER MOUNT. C. CONTRACTOR TO VERIFY ALL ANTENNA TIP HEIGHTS DO NOT EXCEED BEACON BASE HEIGHT. D. VERIFY AZIMUTHS WITH RHOS. E. MOUNT & TOWER COMPLIANCE IS BY OTHERS. NO NEW ANTENNAS OR EQUIPMENT SHALL BE INSTALLED ON MOUNTS OR TO W ER WITHOUT THE APPROVAL OF A PROFESSIONAL ENGINEER, F. PROPOSED ANTENNA PLACEMENT LOCATION TO BE FIELD VERIFIED BY GENERAL CONTRACTOR PRIOR TO CONSTRUCTION TO AVOID ANY INTERFERENCE OR SHADOWING OF EXISTING OR PROPOSED ANTENNAS. IF INTERFERENCE OR SHADOWING OF ANTENNAS IS DISCOVERED DURING FIELD VERIFICATION, PLEASE CONTACT A&E VENDOR FOR DESIGN REVISION PRIOR TO ANY NEW ANTENNA INSTALLATION. G. DO NOT OBSTRUCT BEACON IF TOWER LIT. NOTE: G.C. TO FIELD VERIFY ANTENNA PLACEMENT WITH THE AT&T CM PRIOR TO INSTALL. at &t 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CCCROWN CASTLE 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR. STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T&T SITE NUMBER: BU #: 839836 COPPELL (S ROYAL LN) 160 SOUTH ROYAL LANE COPPELL, TX 75019 EXISTING 95.51 MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 4/8/2021 DAD FINALS SA 1 05/25/2021 DAD MA UPDATED SA OF STEVE S. LEE ................................... 124679 1 h%/ONAL FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Planning Administrative Approval coPpEi:i 21 CA6M-162 SHEET NUMBER: REVISION: tgRfilZOP, C-2 1 TOWER TOP EQUIPMENT SCHEDULE (FINAL) ANTENNA SECTOR ANTENNA ELEVATION ANTENNA AZIMUTH CATEGORY PROPOSED CONFIGURATION QTY. a 98'-0" 8. ANTENNA (Al) COMMSCOPE / NNHH-65B-R4 1 ANTENNA (A2) - - ANTENNA (A3) ERICSSON / AIR 6449 B77D 1 ANTENNA (A4) - - ANTENNA (AS) COMMSCOPE NNH4-65B-R6H4 1 FILTER TOWER DIPLEXERS COMMSCOPE / CBC78TDS-43_CCIV2 1 TMA, - - RRHs RRUS-4449 B5/B12, RRUS-32 B30, RRUS-4478 B14, RRUS-8843 B2/B66A 4 98'-01, 129' ANTENNA (131) COMMSCOPE / NNHH-65B-R4 1 ANTENNA (62) - - ANTENNA (B3f ERICSSON / AIR 6449 B77D 1 ANTENNA (134) CCI ANTENNAS / HBSA-M65R-KU-H6 1 ANTENNA (B5) COMMSCOPE NNH4-65B-R6H4 1 FILTER TOWER DIPLEXERS COMMSCOPE / CBC78TDS-43_CCIV2 1 TMA, - - RRHs RRUS-4449 B5/B12, RRUS-32 B30, RRUS-4478 B14, RRUS-8843 B2/B66A 4 (¢7 98'-01, 248' ANTENNA (Cl) COMMSCOPE / NNHH-65B-R4 1 ANTENNA (C2) - - ANTENNA (C3) ERICSSON / AIR 6449 B77D 1 ANTENNA (C4) CCI ANTENNAS / HBSA-M65R-KU-H6 1 ANTENNA (C5) COMMSCOPE NNH4-65B-R6H4 1 FILTER TOWER DIPLEXERS COMMSCOPE / CBC78TDS-43_CCIV2 1 TMA, - - RRHs RRUS-4449 B5/B12, RRUS-32 B30, RRUS-4478 B14, RRUS-8843 B2/B66A 4 COAX/FIBER/DC 7/8" COAX 6 3/8" FIBER 3 13/16" DC POWER 2 3/4" DC POWER 4 7/8" DC POWER 2 3/8" RET 2 MISCELLANEOUS RAYCAP / DC6-48-60-18-8F 3 RAYCAP/DC6-48-60-18-BC-EV 1 EQUIPMENT DESCRIPTION TABLE � SCALE: NOT TO SCALE at&t 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CCCROWN CASTLE 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR. STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T&T SITE NUMBER: BU #: 839836 COPPELL (S ROYAL LN) 160 SOUTH ROYAL LANE COPPELL, TX 75019 EXISTING 95.51 MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION 0 4/8/2021 DAD FINALS dSA 1 05/25/2021 DAD MA UPDATED OF �i .............................. STEVE S. LEE ...................... 124679 : Tag 1 h\ /ONAL Z�'v'z� FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 21 CA6M-162 Planning A41111 Vagve Approval COPPELL SHEET NUMBER: REVISION: 1012 1 C-3 INSTALLER NOTES: 1. COMPLY WITH MANUFACTURERS INSTRUCTIONS TO ENSURE THAT ALL RRH' RECEIVE ELECTRICAL POWER WITHIN 24 HOURS OF BEING REMOVED FROM THE MANUFACTURER'S PACKAGING. 2. DO NOT OPEN RRH PACKAGES IN THE RAIN. 3. ALL PIPES, BRACKETS, AND MISCELLANEOUS HARDWARE TO BE GALVANIZED UNLESS NOTED OTHERWISE. AT&T RRH AND HARDWARE SUPPLIED BY MANUFACTURER (TYP) MOUNTING BRACKET (SUPPLIED W/ANTENNA) MOUNTING PIPE (TYP) ANTENNA MOUNTING PIPE VALMONT- RRUDSM AND HARDWARE (TYP) MOUNTING BRACKET (SUPPLIED W/ANTENNA) ANTENNA WITH RRHs MOUNTING DETAIL SCALE: NOT TO SCALE NEW ANTENNA at&t 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CCCROWN CASTLE 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR. STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T&T SITE NUMBER: BU #: 839836 COPPELL (S ROYAL LN) 160 SOUTH ROYAL LANE COPPELL, TX 75019 EXISTING 95.51 MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 4/8/2021 DAD FINALS SA 1 05/25/2021 DAD MA UPDATED SA DC/FIBER CABLE BUNDLE SNAP -IN HANGER DC/FIBER CABLE DC/FIBER CABLE DC/FIBER CABLE BUNDLE BUNDLE BUNDLE O HANGER ADAPTER GROMMET HANGER ADAPTER GROMMET HANGER ADAPTER GROMMET 0 HANGER HANGER ANGER ADAPTER p GROMMET CLIP -IN HANGER %"' """ ............ .............. .. STEVE S: BUTTERFLY HANGER LEEIII 124679 ���;o�;•. � �� E N SRO.;\���': BONA.. �� 5!1,6�9U► FIRM REGISTRATION #:13897 DOUBLE CLAMP SNAP -IN HANGER ,'� HANGER ADAPTER GROMMET DETAILS � SCALE: NOT TO SCALE BUTTERFLY HANGER CLIP -IN HANGER m IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 21 CA6M-162 SHEET NUMBER: REVISION: C-4 1 NNH4-65B-R6H4 12-port sector antenna, 4x 698-896 and 8x 1695-2860 MHz, 650 HPBW, 6, RET. resbroadband Lw, Band l69aB9G MHrJ end High Bend(1f 2360MHz staysfor c—(4x MIM0) Bantl ECS WCS capab111tyia 14,-t antl aFPGcaticnz corned Mg, Wane arrey tleelgn awlde: "gnat goo- one narrmer venleal n�mwlan ianlmtlNpnalemennacesigns. ago bay 5,mrtR(4MM.)an .a1aa1—(4 pert ss:, op=ratrg bantls Eprs wmd IoaSrg cM1aremalsttcs • Suppo see-corilgurabe antenna sM1aringcapsalllly enablirg comro of Rye lmanal RCT system usirg up to pnc sepa's'e P.ETcompaetle OEM r«cos General Specifications EH«tire Pmjacdx k.(EPA), Rvmal ,1n, 16.3q)ft' EM«dve ProJ«ure Arae(EPAJ, I— 0.22 nF 1 2— omrm,ne rrPe cops tmg braceree ndumerana baargmunammaeamnr ara PeRotma«exou 0meca wage N'lndlwtlingtlgur«a hdatedb'yvAneronpel maaaremen<aaexndea m.1...pe-wP-I ID-11 Ratlorm Material Fibxglase UV reSiSant Radl«otMmrla Low lcaa Arco@boare IRF olcom Re Cpnn«mr—Ifty, high bentl B RF Conn«tor—u hy, low baM 4 Re C... —aanxy, cool 12 Remote Electrical Tilt(RET) Information, General Ran RET II-ith a Bpn DIN Pemele 1 3p-1x Mea NNH4-65B-R6H4 act —I 2remee 1 2-1, Dimensions vmm� 49e mm I Is.6c6ln .0h ig]mm 1 711n Emgtn IB2a mm I n.969n Array Layout nrrav Frey IMxxl ro ns IMwm alsG 1ET ulo 69&s96 1-z 1 CPxa--axanm 1 691 - 1 CPxlnxxxxxl000nxxmm.2 ss2360 LPxvxxzxxvxvxxmm.3 7-- 16952360 9-10 5It on6 CPxuxrsxxvxnxanm.6 Port Configuration COMMSCOPE° wr°.n.minro,m..am m°a_,.. <w. ,.a°.,re�,amb�. COMMSCVPE Product Specifications COMMSO®PE• CBC78T-DS 43-2X I E14F05P50 a exer xxz/BSOMNz, pe aenw, 43-lo Gnn«mrs � . dts to «er ana see er<oanxnnae ,r.non 0—ral Sp.dfkai ions Elecmiml Spmifkations m 1121314 t121314 112I,314 Electrical SpeciAcatians, Band p'o zo ea Na s ryp aam eO aB P'04'dClassifimrian p r, do Powar/Alarm Ekdrkal Spmlficadons a4A1sa Pa:a-tnmugn nelnoa 'v G Pass- hr-gn Pmh tame q .emrm B.. w.... x a,m.a 1 e nm�. Frvnv„��i',a con-.,,�mm lamnmm.'.1-Nat. x�l. a,�axlT 2 DIPLEXER SPECIFICATIONS SCALE : NOT TO SCALE Product Specifications cx.rewndex I ­w.,v.,,. fill Diagram L(CCJ 11 Logic Table lenl6mulx axal WnlsOPausaxmkn ., �trofePx• • 11 1Wr0 bFFx'01 sPneln Moae aPemsm�pa..., rapt vo vo _v, ' °C/a aMam snarwn M•ehanieal Spedfi-Hanle c a non t g ne xamwaa eaw�am�lm Dimensions min mI6 10 .a gml z nouns. q Hareware e q t o s Eg 1 F.116 Eneiro oral specifi R COMMSC3PE' o°` n"p'.i�y x 2 o,ner .1 x12 Ericsson 64Tx AIR 6449 B77D • Advanced Antenna System (AAS) • 64TX/64RX with 192 AE Up to 320W RF Pewee • EIRP up to 79 dam • Up to 200 MHz IRW&CAW • Max total carrier BW 1s 201 far RR Support number of layers: DL/UL 166//8 �` tmmm (rioerr�p aee`�,I atw • 4 x 25 Gbps ECP RI, (compatible to 10G) eCPR15FP 28 -48 VDc, max 154o W -40 to+55. c, (Intl Solar Load) Typical power consumption <1130 W. *NOTE E// sites will use one side of the VDU for Low Band, A 6630 (+ 160w) for Mid Band and a Front Haul Gateway + 3 Radios /--��ANTENNA SPECIFICATIONS �IJSCALE: NOT TO SCALE D11TA SREET � DC Surge Protection Solutions DC6.48.60.18.8C-EV Overvoltage Pmtecnon and FIa oinributiomcable wm91-1 solution — Rooftop I Towertop Th nC64&b0 13 8C EV ie SEfFfE'pBOffY mtla^ p tl .te 2 c ' between in SPD tl ; the I R.dIrg U b1 dlennr3 Itl gey-I low -clamping voltage c' 160V 160V antl eMremely robust pmtec110n'0r use in e high OC cottage Cenpro ding apa0lo offproviding 12.5nA i10350 us) mz per surge6 pastry i0r up is 6 46V DC clrculR. Fra— ' de pmt«rlcn lo'S Ev pr 1., of 9-W20 Ps Copper -cosies oa-ere 0, sower one Inlederence dc ICbnea d RRHRi it n a0 a,re abe cone olive ra]o G } - ibtln6 mere" 4 d g d d g qu tame" I. ) ueque mantemncaree Prmscrnn agans. d recingF:n ng anams 1 Design praAtles maximum T9's installation t - - nlrMnfir, 4x encleswe a. ows ronndo«awmwr "Wauseon Ll. naa.�ab. melre,aarma,�.maar.P cmra wawPoza�'zna ®eo u Raycap I wxwm �p Pm 3 RAYCAP SPECIFICATIONS SCALE: NOT TO SCALE l:] a�ef, FAT Access RRLI Mount KR for Bark -to -Bark Mounting of (2) RRUs to Rmnd. Shalgh' ar Tapered legs Fat pzlterla zee urww.cz-p—on Product Uassi ficatlon I — - General General Specifications txx.t— xa..r _ t rued nimensions hnga wlm _'emmm Eon mogs«panes Material spwreations dm.11 rmrapgrn,,.«rrm packaging and Weights P.awenw� r 1 4_wm. ways,... tes s xb Regulamry Cornpllance/Certifications wgvny c safxrvea at&t 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CCCROWN CASTLE 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR. STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T&T SITE NUMBER: BU #: 839836 COPPELL (S ROYAL LN) 160 SOUTH ROYAL LANE COPPELL, TX 75019 EXISTING 95.51 MONOPOLE ISSUED FOR: REV DATE DI DESCRIPTION 0 4/8/2021 DAD FINALS 1 05/25/2021 DAD MA UPDATED JSA STEVE S. LEE ......................................... 124679 /C E.N. SRO FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 21 CA6M-162 Ilrg minlsirative Approval BRACKET SPECIFICATIONS COPPELL SHEET REVISION: 4 _ con 1 SCALE: NOT TO SCALEC-5 M EYp21 PARTS LIST ITEM QTY PART NO. PART DESCRIPTION LENGTH UNIT WT_ NET WT. 1 6 X-LWRM RING MOUNT WELDMENT 68.81 412_M 2 6 X-RMBP RING MOUNT BENT PLATECONNECTION 15112 in 17.02 102.13 3 6 X-VFAPL4 VFA-HD PIVOT PLATE 12 In 19-03 99-30 4 6 Y.-VFAW SUPPORT ARM 71Al 429-44 5 30 SCX2 CROSSOVER PLATE Tin 4_90 143-Iig $ 6 P284 2-30R' X 8 ' SCH 40 GALVANIZED PIPE 94 in 2891 191.47 7 15 P30120 2- NB" x 120" (2-112' SCH.40) GALVANIZED PIPE 120 in 58.07 870_99 8 6 P30150 2-M!" X 150-(2412" SCH. 40) GALVANIZED PIPE 150 in 76.94 461-52 9 12 X-127594 FLAT DISK CLAMP PLATE 4" CENTERS (GALV.) 2.61 30.08 10 24 X-100064 CLAMP (4" V-CLAMPI GALVANIZED 0.92 22.12 11 12 A34212 314" x 2-1f2" UNC HEX BOLT (AMS) 2 V2 in 0.48 575 12 18 G34FW 314' HDG USS FLATWASHER 0.06 1.06 13 12 G34LW 314"HDG LOCKWASHER 0.04 0.51 14 12 G34N UT 3f4" HDG HEAVY 2H HEX NUT 0.21 2.55 15 18 G58R+18 Sf8" x 48'THREADED ROD (HDG.) 4.18 75.27 16 42 X­UB5300 518' X 3" X 5-114" X 2-112" U-BOLT (HDG.) 1.15 13.79 17 24 A582112 Sf8" x 2-112" HOG A325 HEX BOLT 2 11`2 in 0.33 8_02 18 24 A582114 SM" x 2-114" HDG A325 HEX BOLT 2 NA in 0.31 7.50 6. 19 108 G53LW 5M"HDGLOCKWASHER 0.03 2.82 20 108 G56NUT 518" HDG HEAVY 2H HEX NUT 0.13 14.03 21 120 X-UBi300 1f2-X3'XS"X2"GALVU-BOLT 0.74 88.64 22 24 01206S 112" x 6-1/2" HDG HEX BOLT GRS FULL THREAD S 112 in 0.41 9.83 23 24 131204 V7' x 4" HOG HEX BDLT GR5 FULL THREAD Ain 0.27 6.48 24 288 G12FW 112" HDG USS FLATWASHER 3132 in 0.03 9.82 25 288 612LW 1I2" HDG LOCKWASHER 118 in U.01 4.00 26 288 G12NUT 1P1" HDG HEAVY 2H HEX NUT U.07 20.63 61 TOTAL WT. 0 2999.58 TOLERANCE NOTES LO[atlHr LESS:RN:IPON NAUa are R. OIBMd41p4NWEDME OTHPRWIaENOTEDARI THREE SECTORS H EAVY WILL FRAME � + au II% SAWIM.SHEARE 4tAYYlD,eNP�DANDMAaarrrnampra.moa7 AND MONOPOLE ATTACH MENTHARDWARE [ su >•..,.: LaAA�ngwgx•cn r'h��xalx DRILLED AND GAS CUT "OLESOdLM)-NO00NINOOFHOLM WITH FIVE MOUNTING PIPES 18887557M4 swan. O LAMA OLFr W003 AND FIOLIS (10,07a"J - NOODNINO OF "OLN _) A ►almont qP' TX DEWW ARE x V2 DROFEti LPO N0. 0"wN OY ENO. APPROVAL PART No, ALL OMM YAOFIIIIIIIIIi4 99AM') ALL4111�la* Y1'1a0�9 CEK 10MM018 VFA12-M3-WLL o CLAMI SUA nRAYeHC.,USAGE C:HKxEh9r At.1Y�YYt1Yr hYMO. Na ;n 00Mf X7A9M�~"n N`rM°wrm°"�` AIY��T. WII� a ouo,Anx�wnoln Tl! 81 1 02 CUSTOMER BMC 10/2912018 VFA12-M3-WLL41 VFA12-M3-WLL SPECIFICATIONS SCALE: NOT TO SCALE at&t 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CCCROWN CASTLE 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR. STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T&T SITE NUMBER: BU #: 839836 COPPELL (S ROYAL LN) 160 SOUTH ROYAL LANE COPPELL, TX 75019 EXISTING 95.5' MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 4/8/2021 DAD FINALS SA 1 05/25/2021 DAD MA UPDATED SA i r ; . 1 . . .... ................... . S00 TEVE S. LEE ................. 124679 CENS���,��� ,.ONAL FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 21 CA6M-162 Planning AtlminiaVetive Approval SHEET NUMBER: REVISION: COFFELL ,onruzoz, C-5.1 1 8" PVC PLUG TO ANTENNA COAX COPPER/GALVANIZED GROUND BAR O J OI IO�_ O O O O O O O O O O O O O O 0 0 0 A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TWO HOLE LONG BARREL COMPRESSION LUG (TYPJ NOTES: 1. DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED. 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL. ,-�ANTENNA GROUND BAR DETAIL �JSCALE: NOT TO SCALE TO ANTENNA COAX COPPER/GALVANIZED GROUND BAR O O O O O O O O O O O O O O O l O.J O .O O O O O O O O O O O O O O IIJO O O O O O O O O O O O O O O O O TWO HOLE LONG BARREL COMPRESSION LUG (TYP) #2 SOLID TINNED COPPER CONDUCTOR TO TOWER/SHELTER GROUND RING (2 TYP. FOR BOTTOM GROUND BAR ONLY) NOTES: 1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). 3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. �, `\ TOWER/SHELTER GROUND BAR DETAIL �L SCALE: NOT TO SCALE STAINLESS STEEL BOLT (TYP) STAINLESS STEEL FLAT WASHER TO TOWER MOUNTED EQUIPMENT 2-HOLE CRIMP/ (TYP) (TYP) COMPRESSION MONOPOLE CONNECTOR 59 TO ANTENNA C ANTENNA GROUND BAR GROUND LOCATED AT MCL BAR (BONDED TO TOWER STEEL) STANDARD COAX I I 2 HOLE LUG (TYP) STAINLESS STEEL CABLE GROUND KIT FLAT WASHER (TYP] STAINLESS STEEL (TYP) BELLVILLE WASHER STAINLESS STEEL NUT #6 STRANDED CU WIRE WITH (TYP) (TYP) GREEN, 600V, THWN INSULATION (OR AS PROVIDED WITH GROUND SINGLE CONNECTOR AT GROUND BARS KIT) (TYP) STAINLESS STEEL BOLT MECHANICAL CONNECTION STAINLESS STEEL FLAT WASHER (TYP) COAX COAX GROUND BAR WITH DRAGON TOOTH WASHER (TYP FOR ALL) \ DIRECT LYOTO HOE BOTTOM OF (TYP) STEEL MONOPOLE. SEE NOTE 1. TO BTS EQUIPMENT VIA TRAY OR ICE BRIDGE 2/0 TINNED BARE COPPER WIRE MONOPOLE PIER GROUND WIRE SEE NOTE 3 GROUND WIRE NOTE 3 INSPECTION WELL EXOTHERMIC WELD (TYP) NOTES: 1. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATIONS AND CONNECTION ORIENTATION. COAXIAL CABLES EXCEEDING 200 FEET ON THE TOWER SHALL HAVE GROUND KITS AT THE MIDPOINT. PROVIDE AS REQUIRED. 2. ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE USA INC. TOWERS. ALL MECHANICAL CONNECTIONS SHALL BE TREATED WITH AN ANTI -OXIDANT COATING. 3. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE RECOGNIZED EDITION OF ANSI/TIA 222 AND NFPA 780. /-TYPICAL ANTENNA CABLE GROUNDING `r SCALE: NOT TO SCALE 2-HOLE CRIMP/ COMPRESSION STAINLESS STEEL CONNECTOR CV FLAT WASHER (TYP) STAINLESS STEEL STAINLESS STEEL NUT BELLVILLE WASHER (TYP) (TYP) SINGLE CONNECTOR AT STEEL OBJECTS STAINLESS STEEL STAINLESS STEEL SELF -DRILLING METAL SCREW (TYP) FLAT WASHER TYP) 2-HOLE CRIMP/ COMPRESSION CONNECTOR DRAGON TOOTH METALLIC OBJECT WASHER (TYP) SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS 8 SCALEHARDWARE DETAIL FOR EXTERIOR CONNECTIONS : NOT TO SCALE T/FINISH GRADE EXOTHERMIC WELD CADW ELD TEST LOOP TO GROUND RING WIRE 8" PVC PLUG CPLG. (THIRD.) SUBGRADE #2 SOLID (TEST LOOP) NOTCH SIDES OF 8" PVC SCH 40 PIPE TO ALLOW EXIT/ENTRANCE OF GROUND RING WIRE TRENCH BOTTOM 2/0 TINNED CU EXTERNAL TOWER GROUND RING WIRE 5/8" 0 x 10'-0" LONG COPPER CLAD GROUND ROD NOTES: 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6' BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) INSPECTION WELL DETAIL SCALE: NOT TO SCALE 6" WIDE METALLIC HTEL GRADE WARNING/LOCATOR TAPE AT 12' DEPTH N 0 0 z z o z 0 w EXOTHERMIC WELD GROUND RING 12 COPPER WIRE SOLID, TINNED FOR CARRIER AND ICE BRIDGE GROUNDLOOP GROUND RING 2/0 FOR TOWER GROUND LOOP GROUND ROD COPPER CLAD STEEL ROD W/MIN. 5/8 OJ x IU-0" LONG NOTES: 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) � GROUND ROD DETAIL v SCALE: NOT TO SCALE LoPP>✓ii, t&t 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CCCROWN CASTLE 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR. STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T&T SITE NUMBER: BU #: 839836 COPPELL (S ROYAL LN) 160 SOUTH ROYAL LANE COPPELL, TX 75019 EXISTING 95.5' MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 4/8/2021 DAD FINALS SA 1 05/25/2021 DAD UPDATED SA OF T ...................................SLEE 1 24679 yo .�/OENS�O•:\��J 11 %%TONAL FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 21 CA6M-162 SHEET NUMBER: REVISION: G-1 1 WEATHERPROOFING KIT (SEE NOTE 31 ANTENNACABLE — WIRE SIZE BURNDY LUG BOLT SIZE #6 AWG GREEN INSULATED YA6C-2TC38 3/8" - 16 NC S 2 BOLT TYPE HS TYPE 2-YA-2 TYPE XA TYPE YA-2 TYPE GY #2 AWG SOLID TINNED YA3C-2TC38 3/8" - 16 NC S 2 BOLT � ^ �IlPJ�1\\1 #2 AWG STRANDED #2/0 AWG STRANDED #4/0 AWG STRANDED YA2C-2TC38 3/8" - 16 NC S 2 BOLT YA26-2TC38 3/8" - 16 NC S 2 BOLT YA28-2N 1 /2" - 16 NC S 2 BOLT TYPE VV TYPE VN TYPE NC TYPE SS TYPE GR BURNDY GROUND LUG W/ HEAT SHRINK LONG BARREL (SEE CHART) (CLEAR) GROUNDING NUT (TYP) CONDUCTOR LOCK WASHER (TYP) TYPE VS TYPE VB TYPE PT TYPE GT- NOTE: 1. ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. 2. MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD. ��CADWELD GROUNDING CONNECTIONS SCALE: NOT TO SCALE (TYPICALLY) 12' TO 24" I120'MAX. 1 #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR). SEE NOTE 1 & 2 Na CABLE GROUND KIT CABLE CONNECTOR NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. ��� CABLE GROUND KIT CONNECTION �`�JSCALE: NOT TO SCALE 3/15-1 lzl"TAMPER RESISTANT BOLT (TYP) INSULATORS SEE NOTE 2. (TYPJ WALL BRACKET ® (TYP) ® 0 o 0 0 ® 0 UNIVERSAL COPPER 0 GROUND BAR (4'S(20') HER LOCK WASHER P/N P/N (TYP) TWO -HOLE COMPRESSION LUG NOTES I. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOTED BE INSTALLED ON CROWN CASTLE USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY GAS-STD-10091. NO MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, CAD -WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. 6 GROUND BAR DETAIL SCALE: NOT TO SCALE TO ANTENNAS COAX JUMPER (TYI CONN WEATHERPROOF (TYP. SEE ANTENNA TO BTS EQUIPMEN GROUND BAR J BOLT (SEE CHART) TYP) BURNDY TWO HOLE LUG W/ LONG BARREL \ (SEE CHART) `BARE WIRE TO BE NO-OX AT BOTH ENDS STRANDED (GREEN INSULATED) ONLY FOR #6 AWG -(SEE CHART) WEATHERPROOFING (IT (TYP) NOTES: GROUND KIT (TYP) 1. ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. #6AWG 2 MECHANICAL LUG CONNECTION COPPER/GALVANIZED COAX SCALE: NOT TO SCALE GROUND BAR BONDED DIRECTLY TOWER 46 AWG MIN. FROM ANTENNA CABLE GROUND KIT NOTES: 1. DO NOT INSTALL CABLE GROUND KIT ATA BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. GROUND BAR ON SHELTER. ICE BRIDGE, OR ON ANTENNA TOWER 2. WEATHERPROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE USED. GROUND CABLE CONNECTION SCALE: NOT TO SCALE "TWO HOLE LUG, OR EXOTHERMIC WELD TO BE USED WITH #2 AWG BARE CONDUCTOR WIRE TO BUILDING SERVICE GROUND OR GROUND RING GROUNDING SHALL BE ELIMINATED WHEN GROUND BAR IS ELECTRICALL" BONDED TO METAL TOWER at&t 1801 VALLEY VIEW LANE FARMERS BRANCH TX 75234 CCCROWN CASTLE 9045 RIVER ROAD, SUITE 425 INDIANAPOLIS, IN 46240 O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR. STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 AT&T SITE NUMBER: BU #: 839836 COPPELL (S ROYAL LN) 160 SOUTH ROYAL LANE COPPELL, TX 75019 EXISTING 95.5' MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 4/8/2021 DAD FINALS SA 1 05/25/2021 DAD MA UPDATED SA `�� O , P'? e 10 *: 5 GROUNDWIRE INSTALLATION I STEVE S. LEE j NOTE: MINIMUM OF 3 THREADS TO BE SCALE: NOT TO SCALE ••••/ S/S NUT VI�TYP) (TYPJ �� �' /1 2 4 6 7 9 2 HOLE LONG S/S SPLIT (,li%�•• ` I� c `C/O. •• ��� BARREL TINNED WASHER 1�1 • ICE �I J ;. •,,•\G��� ` SOLID COPPER (TYP) #2 TINNED SOLID IN 3/4" LIQUID TIGHT CONDUIT PIPE 1�` �/• ••••••�\=�Z• LUG FROM24" BELOW GRADE TO WITHIN 370 6" OF �� ONAL �� (TYP) S/S FLAT CAD -WELD TERMINATION POINT. EXPOSED END\\\\\�� WASHER OF THE LIQUID TIGHT CONDUIT MUST BE SEALED _ FIRM REGISTRATION #:13897 (TYPJ WITH SILICONE CAULK. - _ TINCOATEDSOLID COPPER BUS BAR 1/1 FLAT WASHER CHERRY INSULATOR (TYP) INSTALLED IF REQUIRED S/S BOLT (TYPI LUG DETAIL 7 SCALE: NOT TO SCALE CADWELD (TYP) TIE INTO EXISTING GROUND RING 8 TRANSITIONINO GROUND DETAIL SCALE: NOT TO SCALE IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. Planning RtlminiHrHive Approval COPPELL on, 21 CA6M-162 SHEET NUMBER: G-2 REVISION: