Loading...
876558_CD_FINAL_REV2_S&S_VRZ_5G_LSUB6_MOD_09-13-2021_v1.ADM_APPverizon)/ VERIZON SITE NUMBER: 295251 BUSINESS UNIT #: VERIZON SITE NAME: WRANGLER SITE ADDRESS: SITE TYPE: MONOPOLE COUNTY: TOWER HEIGHT: 71'-6" JURISDICTION: SITE INFORMATION CROWN CASTLE USA INC. F3 - COPPELL MIDDLE S SITE NAME: SITE ADDRESS: 1305 WRANGLER CIRCLE COPPELL, TX 75019 COUNTY: DALLAS MAP/PARCEL #: 65-0056-405-005-00-000 AREA OF CONSTRUCTION: EXISTING LATITUDE: 32° 56' 5.32" LONGITUDE: -97° 0' 5.84" LAT/LONG TYPE: NAD83 GROUND ELEVATION: 526.5 FT CURRENT ZONING: ---- JURISDICTION: CITY OF COPPELL, TX OCCUPANCY CLASSIFICATION: U TYPE OF CONSTRUCTION: IIB A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION PROPERTY OWNER: COPPELL INDEPENDENT SCHOOL DISTRICT TOWER OWNER: CROWN CASTLE USA, INC. 1220 AUGUSTA DRIVE HOUSTON, TX 77057 CARRIER/APPLICANT: VERIZON WIRELESS 6696 TRI COUNTY PARKWAY, SUITE 100 SCHERTZ, TX 78154 ELECTRIC PROVIDER ONCOR 888-313-4747 TELCO PROVIDER VERIZON 800-483-2000 PROJECT TEAM DESIGNER FIRM: BROADUS SERVICES 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS, TX 76016 PH: (817) 349-3449 ENGINEER FIRM: CAA SOLUTIONS, PLLC 3400 STRATFORD ROAD ATLANTA, GA 30326 PH: (770) 548-8268 CONTACT: ALEXANDER ABERNATHY, P.E. CROWN CASTLE 1220 AUGUSTA DRIVE USA INC. DISTRICT HOUSTON, TX 77057 CONTACTS: LAUREN WADE - PROJECT MANAGER LAUREN. WADE@CRO WNCASTLE. COM (972) 374-4010 JOEL MCCALL - CONSTRUCTION MANAGER JOEL.MCCALL@CROWNCASTLE.COM (512) 680-8108 NICK CHAPMAN - A&E SPECIALIST NICHOLAS.CHAPMAN@CRO WNCASTLE.COM VERIZON 5G L-SUB6 - CARRIER ADD DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET T-2 GENERAL NOTES C-1 SITE PLAN C-2 TOWER ELEVATION & ANTENNA PLANS C-3 EQUIPMENT SCHEDULE C-4 PLUMBING DIAGRAM C-5 EQUIPMENT SPECS C-6 EQUIPMENT SPECS G-1 GROUNDING DETAILS G-2 GROUNDING DETAILS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 1X17. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. I CONTRACTOR PMI REQUIREMENTS 1 PMI ACCESSED Xi https://pmi.vx smut.com SMART TOOL VENDOR PROJECT NUMBER 10078301 VzW LOCATION CODE (PSLC) 295251 ** PMI AND REQUIREMENTS ALSO EMBEDDED IN MOUNT ANALYSIS REPORT J MOUNT MODIFICATION REQUIRED y VzW APPROVED SMART KIT VENDORS REFER TO MOUNT MODIFICATION DRAWINGS PAGE FOR VzW SMART KIT APPROVED VENDORS 876558 1305 WRANGLER CIRCLE COPPELL, TX 75019 DALLAS Planning Administrative Approval COPPELL 12/03/2021 CITY OF COPPELL, TX LOCATION MAP �Y9oa, 00 - Oraavasmnn S'chml Of Sarre -g l Vs - The I Islrlol at Q Cypress Womrc x nm.0 n pea°"¢ r s,"h 'e fie ,:Io!India -Groceries, ge Held IAaat 8 Restaurant 4 ]1P.` 1Manw;Mns _-_ �Irvirg, Te � � �Finc N6errr Cr ee �-Chuici �andnn. PROJECT DESCRIPTION THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND CONNECTIVITY AND CAPACITY TO THE EXISTING ELIGIBLE WIRELESS FACILITY. TOWER SCOPE OF WORK • REMOVE (3) NOKIA - UHIE B66A RRH 4x45 • REMOVE (3) NOKIA - UHBA B13 RRH 4x30 • INSTALL (3) SAMSUNG - VZSOI INTEGRATED RRH & ANTENNAS • INSTALL (3) SAMSUNG - B2/B66A RRH-BR049 RRHs • INSTALL (3) SAMSUNG - BS/B13 RRH-BR04C RRHs • INSTALL (3) COMMSCOPE - BSAMNT-SBS-1-2 MOUNTS • RELOCATE (E) ANDREW SBNHH-1D65 TO NEW DUAL MOUNTS GROUND SCOPE OF WORK • TBD FIELD VERIFY EXISTING GROUND EQUIPMENT CONFIGURATION. EXISTING EQUIPMENT INFORMATION NOT PROVIDED. NOTE: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER APPLICABLE CODES/REFERENCE DOCUMENTS ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING 2015IBC MECHANICAL 2015IMC ELECTRICAL 2014 NEC ' verizon' 6696 TRI COUNTY PARKWAY, SUITE 100 SCHERTZ, TX 78154 CCCROWN CASTLE 1220 AUGUSTA DRIVE, SUITE 500 HOUSTON, TX 77057 BROADUS services 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 OFFICE: (817) 349 3449 FAX: 800 4014234 VERIZON SITE NUMBER: 295251 BU #: 876558 F3 - COPPELL MIDDLE S 1305 WRANGLER CIRCLE COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DAWN DESCRIPTION DES./QA CDO 05/17/2021 ND PRELIMINARY SN FCDO 08/10/2021 ND FINAL. SN FCD1 08/12/2021 ND FINAL SN CD2 09/13/2021 ND FINAL. SN `,�A•t 4F Tact I11 op .: ...... ... . . .... 121430 FIRM #-. 19170 STRUCTURAL ANALYSIS BY: OTHERS DATED: CAA SOLUTIONS, PLLC MOUNT ANALYSIS BY: TOWER ENGINEERING SOLUTIONS, LLC CONSULTING ENGINEER DATED: JULY 7, 2021 3400 STRATFORD ROAD ORDER ID: 558028 ATLANTA, GA 30326 REVISION: 0 (770) 548-8268 CALL TEXAS ONE CALL (800) DIG-TESS CALL 3 WORKING DAYS BEFORE YOU DIGI Q5 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: T-1 FCD2 CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS: GENERAL NOTES: ELECTRICAL INSTALLATION NOTES: 1. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE TO PROCEED (NTP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN CASTLE USA INC. NOD AT 800-788-7011 & THE CROWN CASTLE USA INC. CONSTRUCTION MANAGER. 2. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. POO OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL REQUIREMENTS. 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI ASSE A10.48 LATEST EDITION AND CROWN CASTLE USA INC. STANDARD CED-STD-10253, INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). 5. ALL SITE WORK TO COMPLY WITH OAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWN CASTLE USA INC. TOWER SITE," CED-STD-10294 "STANDARD FOR INSTALLATION OF MOUNTS AND APPURTENANCES," AND LATEST VERSION OF ANSI/TIA-1019-A-2012 "STANDARD FOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY PROCEDURES. 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATEST APPROVED REVISION. 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, TOWER OWNER, CROWN CASTLE USA INC., AND/OR LOCAL UTILITIES. 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. GREENFIELD GROUNDING NOTES: 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER: VERIZON TOWER OWNER: CROWN CASTLE USA INC. 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY. 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 6. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CROWN CASTLE. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC. 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. CONCRETE, FOUNDATIONS, AND REINFORCING STEEL: 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE. 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 psf. 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90'f AT TIME OF PLACEMENT. 4. CONCRETE EXPOSED TO FREEZE -THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR ENTRAINMENT TO BE BASED ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A MAXIMUM WATER -TO -CEMENT RATIO (W/C) OF 0.45. 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. ALL SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, UNLESS NOTED OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: #4 BARS AND SMALLER.................................................................................... 40 ksi #5 BARS AND LARGER...................................................................................... 60 ksi 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH ....................... 3" CONCRETE EXPOSED TO EARTH OR WEATHER: #6 BARS AND LARGER.....................................................................................2" #5 BARS AND SMALLER.......................................................................... 1-1/2" CONCRETE NOT EXPOSED TO EARTH OR WEATHER: SLABAND WALLS.........................................................................................3/4" BEAMS AND COLUMNS............................................................................. 1 -1/2.. 7. A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 2. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE ILL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. APPROVED ANTIOXIDANT COATINGS (i., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i-, NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, T_ THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL STATE AND LOCAL CODES ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i., PANEL BOARD AND CIRCUIT ID'S). 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 8. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR, TYPE SCOW CORD (#14 OR LARGER) UNLESS OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR TYPE TO CABLE (# 14 OR LARGER), WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75' C (90' C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, ILL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT. 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, ILL, ANSI/IEEE AND THE NEC. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i., POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL. SHALL MEET OR EXCEED ILL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "VERIZON". 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. CONDUCTOR COLOR CODE SYSTEM CONDUCTOR COLOR 120/24OV, 10 A PHASE BLACK B PHASE RED NEUTRAL WHITE GROUND GREEN 120/208V, 30 A PHASE BLACK B PHASE RED C PHASE BLUE NEUTRAL WHITE GROUND GREEN 277/48OV, 30 A PHASE BROWN B PHASE ORANGE OR PURPLE C PHASE YELLOW NEUTRAL GREY GROUND GREEN DC VOLTAGE POS (+) RED** NEG (-) BLACK** * SEE NEC 210.5(C)(1) AND (2) ** POLARITY MARKED AT TERMINATION ABBREVIATIONS: ANT ANTENNA IE EXISTING TT FACILITY INTERFACE FRAME GEN GENERATOR GPS GLOBAL POSITIONING SYSTEM GSM GLOBAL SYSTEM FOR MOBILE LTE LONG TERM EVOLUTION MGB MASTER GROUND BAR MW MICROWAVE (N) NEW NEC NATIONAL ELECTRIC CODE (P) PROPOSED PP POWER PLANT QTY QUANTITY RECT RECTIFIER RBS RADIO BASE STATION PET REMOTE ELECTRIC TILT RFDS RADIO FREQUENCY DATA SHEET RRH REMOTE RADIO HEAD RED REMOTE RADIO UNIT SIAD SMART INTEGRATED DEVICE TMA TOWER MOUNTED AMPLIFIER TYR TYPICAL "MIS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM W.P. WORK POINT APWA UNIFORM COLOR CODE: WHITE PROPOSED EXCAVATION - TEMPORARY SURVEY MARKINGS -ELECTRIC POWER LINES, CABLES, CONDUIT, AND LIGHTING CABLES GAS, OIL, STEAM, PETROLEUM, OR GASEOUS MATERIALS -COMMUNICATION, ALARM OR SIGNAL LINES, CABLES, OR CONDUIT AND TRAFFIC LOOPS - POTABLE WATER RECLAIMED WATER IRRIGATION AND SLURRY LINES ® SEWERS AND DRAIN LINES Planning Administrative Approval COYYEI.I, 12/03/2021 E verizon/ 6696 TRI COUNTY PARKWAY, SUITE 100 SCHERTZ, TX 78154 CCCASCROWN TLE v 1220 AUGUSTA DRIVE, SUITE 500 HOUSTON, TX 77057 BROADUS services /51 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 OFFICE: (817) 349 3449 FAX: 800 4014234 VERIZON SITE NUMBER: 295251 BU #: 876558 F3 - COPPELL MIDDLE S 1305 WRANGLER CIRCLE COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DAWN DESCRIPTION DES./Q CD0 05/17/2021 ND PRELIMINARY SN PCDO 08/10/2021 ND FINAL. SN FCD1 08/12/2021 ND FINAL SN CD2 09/13/2021 ND FINAL. SN �AKs0Fr , C2 .. ............ . ..... .� 12 14 3 0fj 1t /01V CE 4� i� FIRM #: 19170 CAA SOLUTIONS, PLLC CONSULTING ENGINEER 3400 STRATFORD ROAD ATLANTA, GA 30326 (770) 54B-8268 IT IS A VIOLATION OF I.AW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: T-2 FCD J FIELD VERIFY EXISTING GROUND EQUIPMENT CONFIGURATION. EXISTING EQUIPMENT INFORMATION NOT PROVIDED. GROUND EQUIPMENT TO REMAIN: (2) RXXDC-3315—PF-48 OVP-6. GROUND EQUIPMENT TO BE REMOVED: NONE (E) 12'-6" SITE (E) 12'-0" SITE (E) 12'-0" SITE ACCESS GATE ACCESS GATE ACCESS GATE BRIDGE (TYR) (TYP) SITE PLAN SCALE: 3/e6'(FULL srze) N 2' 1' 0 2' 3/16"=1-0" (11.17) (E) FENCE (E) UTILITY FRAME (E) 10'-0"x16'—O" PAD IN 11'-0"x19'-0" AREA (OTHER CARRIER) (E) UTILITY FRAME (E) GPS ANTENNA (TYR) (E) 10'-11"x16' O" PLATFORM IN 10'-0"x16'—O" AREA (OTHER CARRIER) Planning Administrative Approval COFPELL 12/03/2021 ' J verizon 6696 TRI COUNTY PARKWAY, SUITE 100 SCHERTZ, TX 78154 CCCROWN CASTLE 1220 AUGUSTA DRIVE, SUITE 500 HOUSTON, TX 77057 BROADUS� services 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 OFFICE: (817) 349 3449 FAX: 800 401 4234 VERIZON SITE NUMBER: 295251 BU #: 876558 F3 - COPPELL MIDDLE S 1305 WRANGLER CIRCLE COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DAWN DESCRIPTION DES./Q CDO 05/17/2021 ND PRELIMINARY SN FCDO 08/10/2021 ND FINAL SN FCD1 08/12/2021 ND FINAL. SN FCD2 09/13/2021 ND FINAL. SN � xAKs�F...... 01 f; " 1 21 4 3 0 (�ii4,c�SZ!C� NS��•��2��r FIRM #: 19170 CAA SOLUTIONS, PLLC CONSULTING ENGINEER 3400 STRATFORD ROAD ATLANTA, GA 30326 (770) 548-8268 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL. ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C_1 CD L I TIPLEV OF IPM-6"ENT � E= EQU78' TOP OF MONOPOLE ELEV = 71 —6" VERIZON ANTENNA BAD CENTER ELEV = 0 VERIZON EQUIPMENT ANTENNA CL: 55'-0" MOUNT CL 55'-0"' NEW VERIZON EQUIPMENT: (3) COMMSCOPE — 3SAMNT—SBS-1-2 (3) SAMSUNG — VZSO1 INTEGRATED RRH & ANTENNAS (3) SAMSUNG — B2/B66A RRH—BR049 (RFV01U—D1A) (3) SAMSUNG — B5/B13 RRH—BR04C (RFV01U—D2A) INSTALLED ON EXISTING MOUNTS (1) VZWSMART—PLK7 MONOPOLE COLLAR MOUNT ASSEMBLY (3) VZWSMART—PLK6 V—BRACING KIT FOR MONOPOLE (3) OST2875-10 2 1/2" PST (2.875" O.D. X 0.203" THK) X 10'-0" A53 GR—B 35KSI (3) PV—XP-2530—HD PERFECT VISION CROSSOVER CHANNEL BRACKET (3) PV—XA—U PERFECT VISION CROSSOVER ANGLE (2) PIN 115-203 SAFETY CABLE GUIDE (TUF—TUG OR EQUIV.) TOWER ELEVATION ( JSCALE: NOT TO SCALE THE MOUNT ANALYSIS INDICATES THE (E MOUNTS ARE SUFFICIENT CONTINGENT UPON COMPLETION OF MODIFICATIONS DETAILED IN MOUNT MODIFICATION DESIGN DRAWINGS PREPARED BY TOWER ENGINEERING SOLUTIONS, LLC, PROJECT #16226318 (SMART TOOL PROJECT 10078301), DATED JU LY 7, 2021 (E) VERIZON EQUIPMENT TO BE REMOVED: (3) NO KIA — UHBA B13 RRH 4x30 (3) NOKIA — UHIE B66A RRH 4x45 (E) VERIZON EQUIPMENT TO REMAIN: (61 ANDREW — SBNHH-1D65C ANTE (2) RAYCAP — RXXDC-3315—PF-48 OVP-6 INSTALLED ON EXISTING MOUNTS (E) 71-6" MONOPOLE (E) VERIZON FEEDLINES (2) RFS — HYBRIFLEX (6X12) NOTE: ANTENNA ORIENTATION AND VERIZON EQUIPMENT SHOWN HAVE NOT BEEN FIELD VERIFIED. CONTRACTOR SHALL VERIFY THE SITE PLAN AND EQUIPMENT LAYOUT SHOWN AGAINST PRESENT FIELD CONDITIONS. IF PLANS DO NOT MATCH UP WITH SITE CONDITIONS AT TIME OF CONSTRUCTION, CONTACT VERIZON CM IMMEDIATELY. TOWER & ANTENNA STANDARD NOTES: A. TOWER STRUCTURAL ANALYSIS BY OTHERS, DATED ##. PROJECT # ##/ NO NEW ANTENNAS OR EQUIPMENT INSTALLED WITHOUT APPROVAL OF STRUCTURAL ENGINEER AND VER170N. B. INSTALLED EQUIPMENT MUST HAVE A MATCHING CROWN CASTLE USA INC. APPLICATION AND STRUCTURAL ANALYSIS. C. VERIFY AZIMUTHS WITH RFDS D. 2" ANTENNA SEPARATION REQUIRED. CONTRACTOR TO MOVE (E) ANTENNAS TO ENDS OF MOUNT AS REQUIRED. E. MOUNT COMPLIANCE IS BY TOWER ENGINEERING SOLUTIONS, LLC, ANALYSIS DATED JULY 07, 2021. NO NEW ANTENNAS OR EQUIPMENT INSTALLED ON MOUNTS WITHOUT THE APPROVAL OF A STRUCTURAL ENGINEER. F. PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, (E) TOWER AND TOWER FOUNDATION MUST BE ANALYZED BY A LICENSED STRUCTURAL ENGINEER TO VERIFY TOWER IS CAPABLE OF SUPPORTING THE PROPOSED LOADS. REFER TO STRUCTURAL ANALYSIS BY OTHERS. G. PROPOSED ANTENNA PLACEMENT LOCATION TO BE FIELD VERIFIED BY GENERAL CONTRACTOR PRIOR TO CONSTRUCTION TO AVOID ANY INTERFERENCE OR SHADOWING OF EXISTING ANTENNAS. IF INTERFERENCE OR SHADOWING OF EXISTING ANTENNAS IS DISCOVERED DURING FIELD VERIFICATION, PLEASE CONTACT (A&E VENDOR) FOR DESIGN REVISION PRIOR TO ANY NEW ANTENNA INSTALLATION. H. DO NOT OBSTRUCT BEACON IF TOWER LIT. THE MOUNT ANALYSIS INDICATES THE (E) MOUNTS ARE SUFFICIENT CONTINGENT UPON COMPLETION OF MODIFICATIONS DETAILED IN MOUNT MODIFICATION DESIGN DRAWINGS PREPARED BY TOWER ENGINEERING SOLUTIONS, LLC, PROJECT #16226318 (SMART TOOL PROJECT 10078301), DATED JULY 7, 2021 Planning Administrative Approval COFPELL 12/03/2021 IL) V-1—IN --N U — R� ONTO NEW ANDREW — SBNHH (6 TOTAL, 2 PER (E) VERIZON RRU TO BE REMOVED: NOKIA — UHIE B66A RRH 4x45 (3 TOTAL, 1 PER SECTOR) (E) VERIZON SECTOR MOUNT TO REMAIN (3 TOTAL, 1 PER SECTOR) (E) VERIZON RED TO BE REMOVED: NOKIA — UHBA B13 RRH 4x30 (3 TOTAL, 1 PER SECTOR) (E) VERIZON ANTENNA ANDREW — SBNHH-1D65C (6 TOTAL, 2 PER SECTOR) NEW VERIZON SIDE BY SIDE MOUNT COMMSCOPE — BSAMNT—SBS-1-2 (3 TOTAL, 1 PER SECTOR) NEW VERIZON RRH SAMSUNG — 32/1366A RRH-13R049 (3 TOTAL, 1 PER SECTOR) NEW VERIZON RRH SAMSUNG — 35/1313 RRH—BR04C (3 TOTAL, 1 PER SECTOR) (E) VERIZON SECTOR MOUNT TO REMAIN (3 TOTAL, 1 PER SECTOR) NEW VERIZON VZWSMART—PLK7 MONOPOLE COLLAR MOUNT ASSEMBLY (1 TOTAL) ALPHA) (E) VERIZON OVP-6 TO REMAIN: RAYCAP — RXXDC-3315—PF-48 (2 TOTAL) (E) 71'-6" MONOPOLE TOWER JTH EXISTING ANTENNA LAYOUT SCALE: NOT TO SCALE N NEW VERIZON INTEGRATED RRH & ANTENNA: SAMSUNG — VZS01 (3 TOTAL, 1 PER SECTOR) (E) VERIZON OVP-6 TO REMAIN: RAYCAP — RXXDC-3315—PF-48 (2 TOTAL) NEW VERIZON OST2875-10 2 1/2" PST (2.875" O.D.xO.203" THK)x10'—O" A53 GR—B 35KSI (3 TOTAL, 1 PER SECTOR) (E) 71'-6" MONOPOLE TOWER NEW VERIZON VZWSMART—PLK6 V—BRACING KIT FOR MONOPOLE (3 TOTAL, 1 PER SECTOR) I UTH NEW VERIZON PV—XP-2530—HD PERFECT VISION CROSSOVER CHANNEL BRACKET (3 TOTAL, 1 PER SECTOR) NEW VERIZON PV—XA—U PERFECT VISION CROSSOVER ANGLE (3 TOTAL, 1 PER SECTOR) NEW ANTENNA LAYOUT SCALE: NOT TO SCALE N m verizom/ 6696 TRI COUNTY PARKWAY, SUITE 100 SCHERTZ, TX 78154 CCCROWN CASTLE 1220 AUGUSTA DRIVE, SUITE 500 HOUSTON, TX 77057 BROADUS� services 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 OFFICE: (817) 349 3449 FAX: 800 4014234 VERIZON SITE NUMBER: 295251 BU #: 876558 F3 - COPPELL MIDDLE S 1305 WRANGLER CIRCLE COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DAWN DESCRIPTION DES./Q CDO 05/17/2021 ND PRELIMINARY SN PCDO 08/10/2021 ND FINAL. SN FCD1 08/12/2021 ND FINAL SN CD2 09/13/2021 ND FINAL. SN � xAK��F•rE�gdIow . .. ...... ... . . .... 1 21 4 3 0 (ji IIIS�!C� NS��•C5 FIRM #: 19170 CAA SOLUTIONS, PLLC CONSULTING ENGINEER 3400 STRATFORD ROAD ATLANTA, GA 30326 (770) 548-8268 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-2 FCD J WERT>SouthCIltNWCOF9taC0ntNWTa11FesNar6Ll7cr 111PARCAER M-0. Wacp5-waLtas.ahmed@v iro Mfeles5.com-3R7202111:27.39 Projort Details location Information Carrier Aggregation: false MPT Id: .GIP-0: ra15e Project Name: 50 L-5v46 - CarrieF Add FUZEProject IIT. 1522631.8 Designed Sector Carrier 46: 15 Designed Sector Caviler SG: 3 Additional Sector Carder 4G: N/A Additional Sector Carrier SG: N/A SiteTraker Project Id! FP Solution Type & Tech Type: MODIFiCATION;4G PCs, 5G_L-Su68- Prep,SG_PCS,5G_Radio Swap SNHIxr Site ID: 2623133 E-Noda810: 0132290,1329290,132290 PSL0:295251 SMIL0 News: Euless Tower Owner: TawerType: Other Site Type: MACRO Street Addressr 1305 Wrangler Circle Clty: CDppell Stater Tx Zip Code: 75019 County: Dallas Latitude: 32.934811111 32° 56' 5.32" N LongRude:-97.00162222197' 0' 5.84• W REDS Project 80epea 5GNW and 5G L-Sup6 Larner Add. RRli Upgrada5- Ybb 190C -S A- .1. TCb 190C AWL AW53 Meka A.ienna s,rnm.Tr; Motlx [adedfre np HerFM All- OLT SaW I... Typ. &I 12S01IP(M vdN d9DC11 NAePded Anlwm- w Sa.l ta010Po41 tore bue PHY9LAl a .,aaw ne I - SG L-[ LTs ArmRFvl ,auHwtr.2ar: EI Lacrdon TOC rtIW A- 9wS kb�mt Tw'n LTF LTE LTE LTE ma Torn 64 L- LTE Fn T.... vIr L...�w.. T[tn Nat Ates .t1rR- RRIIN Tim LR LTF LTF jlntenl I- La:adw. ]OC tFOD A- 9WS Dwe� T4ra awl5a tAMY. INSTALLER NOTE: CONTRACTOR SHALL CONFIRM EQUIPMENT CONFIGURATION WITH FINAL VERIZON RE DWS BEFORE PROCEEDING WITH ANTENNA MODIFICATIONS. C-4e ilpTldlkRl AA. NET W4 N.l Ty OWah Caaedm Np.... AemnN 1- 4Rx -Tal CkMMF d9DDn WI) 1501400Y1 .0 .an TFMMi r.t... rove. PHt'Mru a x4dld°NI RIDIO55 FGr®] FrrCo IwueaS Equipment Summary Moles ModN Ca -4Ib [eGe Lln Ineffi'ITrp. -Ift l]omlra:•pe ESAYNr3B9-1S PHYSICAL 3 Sww� � � epbeo PHYSICAL 3 aRIM3 RRIrew4C PHYFICAI 3 Sa' M mPV9Tu-R9A1 vzssl SaPllwla sanr'� '"eBR'°`F°•Ida""°- MY.ICAL a save .P mnenlrne.adml YNm anaa LMre ,y [NYc 3iee Ina[ m h,.nliry Mlle U-11111-1. PHTSILAL 3 Metre IIHIkeLrAHR.14e4R RIYSM.0 3 Mabe ModA Labe LeryM [oNe.41[e Irrstol Typr w.ntny R."I L-09P T�LAL z RFYLW 609P PHYSILAl T ,dn XIa Ll� ,�-�VERIZON EQUIPMENT SCHEDULE SCALE: NOT TO SCALE s.m9r a,k"dX der Fx,d.Flp AnHnn. uelm k.1Fn LIm oo.e.ntXO.R.2 Repdnery Paver TYA2d.b TYA 4PdeI aRuuMa MYIYOM t;.rB�dTT,roIANr F.O. Tr.r.rdlf.I akrFwa.Nro Lr'm N,RR n..am.Cem.dkalPn LIe<1�d Lle..e.anunw.l D.ndw ueYa.Txe TkP x.19M1y RW WIM'Parx� T W McRe w'�iuurx.a' a rrmrntlOxrla A Ih f-.a/Exeee 0 ANwIn.Nrke MMne Cenadlelro Yee oerr.TRXCeR.} F� eem.,Rt Tip Herr Rive Nadel ILmuerNTx, Rem T� A:.,etln S.F! FXe4 Flo MMtuYW Mlwne. rar'Ier1l'epe M.cM1AnlcFl bawn.nLlfn m El.ctrlul CbrmTrl RepJSlerp Paw IYAYeke rYANRdY IIIII Wb 4M1mdn 1`1Ax LYe, adr Fx.c. FID deletFta Yodel AnmurO�Fnle.4w.IPn krs nLtloeai Fkeldplmw-RI TIPXe1pM FAP4YMYPeuw TYAxeke mnYedb 2Y.rtaef T.'�Rx u,w Trn. Ild AiIM A CNr FI3eM NOIO 4.dn.e..m. cl-wo FIRFNMW 9� B rH9eN) Tp Hey,t kLepuMlaPPaw TLW Yek. TLL4 ueeY RRuu.k. RAM YodN lAmdera Ti RxtNx mM ld Tree Sd�[e Service Info m m m nx°x99 i31W3o li�o SeHMY1De5C SaYNIFlfatSC mnXriLT c A.4oRLw d5 AN.- o wDRrw C5 3 9 9 59 1543 I5394 Lax.9a rbm x x.Ya NIBA N33 P[W Ix3C IlX8A F13 31 Pp.i 4K3tr aNLA a1Z. ia3C sw z.1 z. +00P254 46C325F +CCF35fl A39LL A>'I ATmi_4n1 A _ woRew 0 z 59 1FL69 ndkV I.9IN F6FA RRH 4a4S ."255 ATOLLAPi m F ilR90 5&AH1.7pdAC MDRFW a 2 A579 NRkh IHIN 86rA RAN 4.45 4.1 400112151) ATOLL_API ddnF 53219D SaMN41Od5C AND" a 2 mi. NOkl3 CMF BFdA Apx Iy5 4CM57 ATOI.L_API R� in 132290 W IDW AND" Ss 17zz90 SDHFFX]DSSC wDREw ss 3 59 ICC.63 N9xR aI3� lIFM 8AH 4Ra5 4A IOC M ATOLL MI DH ]Ad 132x4d SeNHIF1D1I5C ANDPEW a 59 3M1fi2 N HIrE 368A RAW 4.45 4.4 `C053di1 6696 TRI COUNTY PARKWAY, SUITE 100 b U. 240 SCHERTZ, TX 78154 133x90 13x]98 L3x,So SBNIX141O65C SSIIHi-1rM5[ 58NIH-Lslfix AN.- wOREW AN-. 05 SCS 55 a 3 s9 54 CROWN ie7n 3FTn wim c 5a�m9 5�naro CASTLE G9A13 RPJ4kR61[IRPM141-02A1 B5�313 APH41RC4[ljtF4C1U-02A} FSRI3 PRH43RC4C frdTNla-0bll +.4 T+ssaeF 1I55+8k 7- 1220 AUGUSTA DRIVE, SUITE 500 ATOLL _API ATOµ_AM ATOLLAN HOUSTON, TX 77057 a 1zD x46 sevRlLLzoeac sFMlwaodu sexwut,5x B R O A D U S °"°"F" •";�w services a e 3 a 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 samwn9 saln:tlm seplFt.9 OFFICE: (817) 349 3449 821B6&k P1W-00.C191PFVDla-0lA1 al/kedA RRHA0.C4910.FVC1LLDIA1 R2R3drw RRiiCRP191RFVb1U-0LA} A4 .., a.4 FAX: 800 4014234 ]9166C0 n7M* ]910898 AT _ ATOLL CCCI CCOe 8088 0 120 740 ]31929C SFMMF3DFSC stxiHx tits - x mwx� .]pfi Maim wMNW ANDMW VERIZON SITE NUMBER: 55 55 0 3 295251 t4eu e4a.Fz 14s9. SFm n9 Semwnp Same g BU #: 876558 BilaFbl RRNa0.019IRFYDIH-0u3 92RRFA FWI-0R049 RLFNDLII-0IA] RLTidMRAXdRO991RF401Mt11A7 4.4 14 F3 - COPPELL MIDDLE S 9a333dR .3-1 993070 ATOLL API ATOLL An ATOLL An 1305 WRANGLER CIRCLE 0 126 216 COPPELL, TX 75019 132296 113399 i3229a sexlRuodsc sexwx.lDFx saNrw-]neu N195 AH 55 A"DREW 55 EXISTING 71'-6" MONOPOLE 2 2 8 3 59 59 59 11607 1SF.C1 I1531 Sam9u19 $amsun0 Sanyttn9 axaFU RNx;R049 L.r491uniAl 3RlFdu RHry-Fpoe9luvollr-out e,�sceA RRHa3os4 fRrvmuLu} 41 4.1 ISSUED FOR: TNS-7 7455+0 745WI ATOLL_AFI ATOLL_A., wroLLAPt REV DATE ERVIN DESCRIPTION DES./Q 0' m PCDO 05/17/2021 ND PRELIMINARY SN 13Rm zd 13 a3s;9F PCDO 08/10/2027 ND FINAL SN 5Nxwl.1Rm Dpsr sB11M1-ioRsc seww.inPSc wDRlw wDRFw ANDRsw FCDl 08/12/2021 ND FINAL SN ss 0 s5 C ss b CD2 09/13/2021 ND FINAL. SN ]3LR 732i1 Ini,LR Semzwq Semwnq -.N 82Rd60. APN4fAR491RrUC1LLb14) BLBddA PRi.NN19IRMCl146LV kLD6dA PRti8R059;RNO]VLkAt 4.1 745545Z 745503 10m" rE �y -ATOLL "I ATOLL-- AmLLAw •• �p�( Y:• • 009i 013]294 9pgp d133911 am C132�290 ow y/�),�' • •�� 111 nLdWdAr4euru nL-iWd Mttruu nL-5'lbF wxema r ^"}-iZ��1� •� T"D TBD TRD / T .... . Z 0 Z 0 55 0 � 3 3 57 MAN, Mal4•; 1 21 4 3 0 i Samevng Semwny Suns��g ■+ /4�� n ` ((,� t,y�laJ�o YLSCI VZ501 V2581 •� VjC•e ,1c •��`I AA 4.1 4.4 �(\•�••....... VC5 TI55535 k . ]I55539 1y ` 0 AlIX1JIR1 ATIlLl�idrl TOU; 0.715 �VVS;/�`:=���7y ` FIRM #-. 19170 Planning Administrative Approval COFFELL ' `I "'PIWI 12/03/2021 CAA SOLUTIONS, PLLC CONSULTING ENGINEER 3400 STRATFORD ROAD ATLANTA, GA 30326 (770) 548-8268 IT IS A VIOLATION OF I.AW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-3 FCD W IJ PL=j2j 5Zjb4f8 f&3 RVUW�y 3 d71� R a�idp INSTALLER NOTE: CONTRACTOR SHALL CONFIRM EQUIPMENT CONFIGURATION WITH FINAL VERIZON RE DWS BEFORE PROCEEDING WITH ANTENNA MODIFICATIONS. /��VERIZON PLUMBING DIAGRAM SCALE: NOT TO SCALE s�,:ur+ #e�Crti S#eeller mm ruu Oidm rm a r L FUN 1 Fpl►1fyii IrJ7a orb 0-0S HM .D�IAC, i+lE�des�nEtee� p.ar_ IW F-A I foaxhil-prr L liawjump;r jftd15Gs momgium Jki5ra lurAper Note&: -H" iRitimm5 afarY0um dwrch W&-%-5ideu C m - &`Rmft weim i3 b am She hack 0 the We ma% II d foAri0i114e arm 0A1 #r difrrlC 0Dn -Sim of tlhfQt#s in drawing docetill reflect egr*prnent ime duA&%.SNn - EKb!Wur C5 009101 - Fbeii & pvxd are the Sin& paps farm am 1ybTlf1IeR (mn rie�r��ozitatire ialIII rI.0 IIS,, iwaolf., - tY fhidRca and DVN are nat sk*wn Planning Administrative Approval COFFELL 12/03/2021 6696 TRI COUNTY PARKWAY, SUITE 100 SCHERTZ, TX 78154 CCCROWN CASTLE 1220 AUGUSTA DRIVE, SUITE 500 HOUSTON, TX 77057 BROADUS� services 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 OFFICE: (817) 349 3449 FAX: 800 4014234 VERIZON SITE NUMBER: 295251 BU #: 876558 F3 - COPPELL MIDDLE S 1305 WRANGLER CIRCLE COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DAWN DESCRIPTION DES./Q CDO 05/17/2021 ND PRELIMINARY SN FCDO 08/10/2021 ND FINAL. SN FCD1 08/12/2021 ND FINAL SN CD2 09/13/2021 ND FINAL. SN � xAK��F•rE�gd'�il i ... ............... 1 21 4 3 0 (jii4,c�S��C� NSE�•��e1��r FIRM #: 19170 CAA SOLUTIONS, PLLC CONSULTING ENGINEER 3400 STRATFORD ROAD ATLANTA, GA 30326 (770) 548-8268 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: rSION: C-4 D SAMSUNG Dual -Band Radio Unit AWS/PCS (B66/B2) RFVOIU-DI.A Sam un g's RF V01U-D1A is a compact remote Radio Unit (RU) designed for deployments that require Flexibility in installation and rapid onlining, without compromising on coverage, capacity or operational expenses. y:15no"EX Dual -Band Radio Unit 700/850MHz (B 13B5) RFVOlU-D2A Samsung's RF VOI U-D2A is a compact remote Radio Unit (II designed for deployments that require flexibility in installation mid rapid onlining, without compromising on coverage, 41 capacity or operational expenses. Technical Specifications The RFVOIU-D1A RU targets dud -band support across Baud - 66 (AWS) and Rand 2 (PCS), making it an ideal product for \ The RFV01 U-132A RU targets dual -band support across Band broad coverage footprints across multiple common mid -range 13 (70OMHz) and Band 5 (850MHz), making it an ideal frequcncies. product for broad coverage footprint, across multiple - `°manou low -end, long-range frequencies. Tech LTE/SG NR The RU haudles¢Il Radio Frequency qncy (RE) processing in ready (Support eCPRI) single, compact unit, and is designed m interface via CPRI The RU handles all Radio Frcqucncy (RF) processing in a with Samsung's CDU baseband offerings, in both distributed- single, compact unit, and is designed to interface via CPRI and central -RAN configurations. with Samsung's CDU baseband offerings, in both distributed- Band Band48 (3.5 G Hz) and central -RAN configurations. In addition to its minimal footprint and case of . allafion, the RU is also designed to reduce cost of ownership through In addition to its minimal footprint and ease of installation, Frequency Band 3550-3700MHz as integrated spectrrm analyzer, which allows for remote RF the RU is also designed to reduce cost o£ownership through '� 0\ omorring, greatly reducing the need for on -site maintenance , s integrated spectrum analyzer, which allows for remote RF visits, monitoring, greatly reducing the need fox on -site maintenance RF Power Total 20 W =43 dBm (4 x 5 W) visits. tBW/OBW 150 MHz / 80 MHz Feature, and Benefits Key T.Wc.1Spmifieatiou Installation Pole/Wall/Tower (Pack to back, Side by side) Fealuras cord Benefit, Key Tecluilcal 6pecifca[ions • Dual -band support for broad frequerwyc-exage Duplex Type: FDD • Minimal footprbn,edaces site costs OpcAW Frequencies: • Dual.baod support fox broad fr quency coverage Duplex Type: FDD Rapid, ea,y i-11ati on 1366:Du2,D0-2,18oldFlz),UU 1,710-1,790MIU) Mii=l fuutpiut xcduce„eau, DPemting Faq ies: Weight/Size RRH: B_S x 12 x 4.2 inches(7.OQ. 17.6 lbs Flexibly deployable in any • location A2: DLC,930-1,9Whm,,)4J" 1,H50-1,91 DWI.) • Rapid, easy installatior. B13-D4746-756N1eUt UH777-i87MHz) • Remote RF morriW,ing wpnbilit Instantaneous tlandwidlh: �2) • Plexibly deployable in any location A5: DL(869-R94MH7)gR4924-849MRx) Ise •q lbs Antenna: 8. x1G-3 x1_3i es 2.3L, 3.3 . Convention cooled silent opuefiou RF C'lui.. 47R/6T4A/2T2R Remote RFmonitmingcapxbdity > Chneon4R'2T4R'2:lOMDzctl13)+25MHz(B5) RF Clwin: 4T4Ri2T4Ri2T2R • Anat-in Broadcast Auxiliary Sevices(BAS)fRer DutputPo Tod1320W • Cmn tion000led.,JmtWemtion OmputP.—Tnta112OW ACAIX:4.1x115x3.3inches (2.6Q,5.51bs anuplianl AW 6 operation without impaolh�g DU-RU Interface: CPR] (10(ibps) DU.RU Interfi CPRF (I0KJWs) Woyalnt Dimensions: 380. 380. 255mm (36.8L) Dimensions: 380. 380 x 207mm (29.91.) 31.9kg RRH + antenna _ 8.7 x 12.3 x SS inches (9.6t) Weight: 38.3kg Input Power: 48V ➢C Opernting Temp.: Ao - ss (w;n ,ewx maa) Weight: Input Power: 48V DC Op—nig Temp.: 40 - 55'(W. al. load) RRH + AC/DC : 11.2 x 12.1 x 4.2 inches (9.3L) Cooling: Natural convstion Cooling: Natural o—doa RRH + antenna + AC/DC =11.3 x 12.3 x S.5 inches (1251L) RRU SPECIFICATIONS SCALE: NOT TO SCALE Figure 3. Systsrn View (whh CNpon Antenna +AGOC Power Unit) RRU SPECIFICATIONS L SCALE: NOT TO SCALE 13SAMNT-SBS-1-2 Side-By-S l? Mounting Cttn mounttwa an-ennas on a pre with 2375-451nch (6U - 1L5 ram) diartleter IUrdt: U.lttint pw seNia andn,.H Es=a,ma5'anre„„a General 5pecif cat]o ns 1 � m \ appllxaee,! a�manr ree. 5 Dime tsions Crop View] re.w•,�d. a•mn.r. n.a,lm�m tla, ram , 4— ryriniea,m.r•r.m:.r:n•am 51 ram saran 11.4(2894) Matedal5pecificdion5 eaeenN type ts—ved soee' Packaging and 1Waghts I IR��4.d l�d�ek I P�,a.ar. • _ I wrllamna quemiN I • I Regulatgry Compliance./Cw't]firacions 1 1A • 11 Ill Araaw� 4 Hr ,e, en, a nn tact Q..... o. Ixo yaal::ors o,s5^•a.m3n.ammee�wa d„ab�pa �,ae a+.nwuy,.a�.9an,.�n,y<le., �, � I AACF !VXC=wnVl�nu a�Vn STIC,uvcix���i mnv,unnm,uV•'.-�neVFm�lu.l'.a�iryliurn Act [Le" View] [Front View] .R.Ohi e:.[ [Rear s: ierv; Included Products 4iAaWR- _ wi ket seta!M xlie tio:mm brac6er sct9 cot Forz4-45in Wl-Its mmlW mui,imm,�rf gt �zm oees,.usw top (,Doom ViI -\VZS01 SPECIFICATIONS (2) �-BSAMNT—SBS-1-2 SPECIFICATIONS `fi SCALE: NOT TO SCALE J SCALE: NOT TO SCALE (-:��VZSO1 SPECIFICATIONS (1) �SCALE: NOT TO SCALE III■ e 311AEE: ��, „- I t (IIII ���'.► . I �Iili51• Planning Administrative Approval COFFELL 12/03/2021 rea�xvsbemni - iAuir �aimniw smm sun �-aure n, � rprmeuy .- 4e. tip �0 iSY'A� lair i A �-�VZWSMART—PLK6 V—BRACING KIT FOR MONOPOLE v SCALE: NOT TO SCALE ' J verizon 6696 TRI COUNTY PARKWAY, SUITE 100 SCHERTZ, TX 78154 CCCROWN CASTLE 1220 AUGUSTA DRIVE, SUITE 500 HOUSTON, TX 77057 BROADUS� services 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 OFFICE: (817) 349 3449 FAX: 800 401 4234 VERIZON SITE NUMBER: 295251 BU #: 876558 F3 - COPPELL MIDDLE S 1305 WRANGLER CIRCLE COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DAWN DESCRIPTION DES./Q CDO 05/17/2021 ND PRELIMINARY SN FCDO 08/10/2021 ND FINAL SN FCDI 08/12/2021 ND FINAL. SN FCD2 09/13/2021 ND FINAL. SN ��AK�oF.rE�gs��l / ...... ....... ..... 121430 ills�o•C5����r FIRM #-. 19170 CAA SOLUTIONS, PLLC CONSULTING ENGINEER 3400 STRATFORD ROAD ATLANTA, GA 30326 (770) 548-8268 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL. ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-5 CD ban x. INAwrimo. eta. 00 00 ®� O A '\VZWSMART—PLK7 MONOPOLE COLLAR MOUNT SCALE: NOT TO SCALE / n SCALE: NOT TO SCALE �� CROSSOVER ANGLE L SCALE: NOT TO SCALE �� NOT USED �SCALE: NOT TO SCALE a= if MYLL� ®[MEV HMo• •V'a�0 E-1 � z� CROSS OVER CHANNEL BRACKET �SCALE: NOT TO SCALE NOT USED v SCALE: NOT TO SCALE Planning Administrative Approval COFFELL 12/03/2021 ' verizont 6696 TRI COUNTY PARKWAY, SUITE 100 SCHERTZ, TX 78154 CCCROWN CASTLE 1220 AUGUSTA DRIVE, SUITE 500 HOUSTON, TX 77057 BROADUS� services 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 OFFICE: (817) 349 3449 FAX: 800 401 4234 VERIZON SITE NUMBER: 295251 BU #: 876558 F3 - COPPELL MIDDLE S 1305 WRANGLER CIRCLE COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DAWN DESCRIPTION DES./Q CDO 05/17/2021 ND PRELIMINARY SN FCDO 08/10/2021 ND FINAL SN FCDI 08/12/2021 ND FINAL. SN FCD2 09/13/2021 ND FINAL. SN A.t�4F.rE�gs�1, i ... ............... 1 21 4 3 0 (jii4,c�S�!C� NS��•��2��r FIRM #: 19170 CAA SOLUTIONS, PLLC CONSULTING ENGINEER 3400 STRATFORD ROAD ATLANTA, GA 30326 (770) 548-8268 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL. ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-6 CD J TO ANTENNA COAX TO ANTENNA COAX COPPER/GALVANIZED GROUND BAR COPPER/GALVANIZED GROUND BAR 0� 0 �00000000000000 j o�� 0000000000000 00000000000000 0 0 0000000000000 DOo0 o000000000000000@ 00000000000000000' 0 #2 SOLID TINNED COPPER CONDUCTOR TO TOWER/SHELTER TWO HOLE LONG BGROUND RING (2 TYR. FORARREL COMPRESSION LUG BOTTOM GROUND BAR ONLY) TWO HOLE LONG BARREL COMPRESSION LUG (TYP) (TYP) NOTES: 1. DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED. 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO ANTENNA MOUNT STEEL. /'-7'\ANTENNA SECTOR GROUND BAR DETAIL SCALE: NOTTO SCALE TO TOWER MOUNTED EQUIPMENT (TYR) TO ANTENNA — STANDARD COAX CABLE GROUND KIT (TYR) #6 STRANDED CU WIRE WITH GREEN, 60OV, THWN INSULATION (OR AS PROVIDED WITH GROUND KIT) (TYR) COAX CABLE (TYP FOR ALL) TO BTS EQUIPMENT VIA TRAY OR ICE BRIDGE MONOPOLE ANTENNA GROUND BAR LOCATED AT MCL (BONDED TO TOWER STEEL) 2 HOLE LUG (TYP) MECHANICAL CONNECTION (TYR) COAX GROUND BAR WITH INSULATORS, CONNECTED DIRECTLY TO THE BOTTOM OF MONOPOLE. SEE NOTE 1 2/0 TINNED BARE COPPER WIRE MONOPOLE PIER GROUND WIRE SEE NOTE 3 GROUND WIRE NOTE 3 Z4�_-- - 1L--�-i-�� INSPECTION WELL I EXOTHERMIC WELD (TYP) I NOTES: 1. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATIONS AND CONNECTION ORIENTATION. COAXIAL CABLES EXCEEDING 200 FEET ON THE TOWER SHALL HAVE GROUND KITS AT THE MIDPOINT. PROVIDE AS REQUIRED. 2. ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE USA INC. TOWERS. ALL MECHANICAL CONNECTIONS SHALL BE TREATED WITH AN ANTI —OXIDANT COATING. 3. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE RECOGNIZED EDITION OF ANSI/TIA 222 AND NFPA 780. TYPICAL ANTENNA CABLE GROUNDING 4 SCALE: NOT TO SCALE NOTES: 1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). 3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. ---\TOWER/SHELTER GROUND BAR DETAIL Z SCALE: NOT TO SCALE STAINLESS STEEL BOLT (TYR) STAINLESS STEEL FLAT WASHER 2—HOLE CRIMP/ (TYP) COMPRESSION CONNECTOR GROUND BAR STAINLESS STEEL FLAT WASHER STAINLESS STEEL (TYR) BELLVILLE WASHER STAINLESS STEEL NUT (TYP) (TYP) SINGLE CONNECTOR AT GROUND BARS STAINLESS STEEL BOLT STAINLESS STEEL FLAT WASHER DRAGON TOOTH WASHER (TYP) STEEL 2—HOLE CRIMP/ COMPRESSION STAINLESS STEEL CONNECTOR J::�LFLAT WASHER YP) STAINLESS STEEL STAINLESS STEEL NUT BELLVILLE WASHER (TYP) (TYP) SINGLE CONNECTOR AT STEEL OBJECTS STAINLESS STEEL SELF —DRILLING STAINLESS STEEL METAL SCREW FLAT WASHER (TYP) (TYP) 2—HOLE CRIMP/ COMPRESSION CONNECTOR DRAGON TOOTH METALLIC OBJECT WASHER (TYP) SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS HARDWARE DETAIL FOR EXTERIOR CONNECTIONS 5 SCALE: NOT TO SCALE T/FINISH GRADE <25T l � w 0 0 z z o EXOTHERMIC WELD IT CADWELD TEST LOOP TO GROUND RING WIRE NOTES: 8" PVC PLUG /-- 8" PVC PLUG CPLG. (THIRD.) #2 SOLID (TEST LOOP) NOTCH SIDES OF 8" PVC SCH 40 PIPE TO ALLOW EXIT/ ENTRANCE OF GROUND RING WIRE TRENCH BOTTOM 2/0 TINNED CU EXTERNAL TOWER GROUND RING WIRE 5/8" 0 x 10'-0" LONG COPPER CLAD GROUND ROD 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) INSPECTION WELL DETAIL SCALE: NOT TO SCALE 6" WIDE METALLIC HTEL GRADE WARNING/LOCATOR TAPE AT 12" DEPTH 0 0 z c� EXOTHERMIC WELD 0 w GROUND RING #2 COPPER WIRE SOLID, TINNED FOR CARRIER AND ICE BRIDGE GROUND LOOP GROUND RING 2/0 FOR TOWER GROUND LOOP GROUND ROD COPPER CLAD STEEL ROD W/MIN. 5/8 0 x 10'-0" LONG NOTES: 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) GROUND ROD DETAIL 6 SCALE: NOT TO SCALE Planning Administrative Approval --C-APPELL 12/03/2021 E verizon/ 6696 TRI COUNTY PARKWAY, SUITE 100 SCHERTZ, TX 78154 CCCROWN CASTLE 1220 AUGUSTA DRIVE, SUITE 500 HOUSTON, TX 77057 BROADUS� services 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 OFFICE: (817) 349 3449 FAX: 800 4014234 VERIZON SITE NUMBER: 295251 BU #: 876558 F3 - COPPELL MIDDLE S 1305 WRANGLER CIRCLE COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DAWN DESCRIPTION DES./Q CDO 05/17/2021 ND PRELIMINARY SN PCDO 08/10/2021 ND FINAL. SN FCD1 08/12/2021 ND FINAL SN CD2 09/13/2021 ND FINAL. SN �F.... q,q . .. ...... ... . . .... l .. ............. . ..... .� 1 21 4 3 0 NS�.C5�2��r FIRM #: 19170 CAA SOLUTIONS, PLLC CONSULTING ENGINEER 3400 STRATFORD ROAD ATLANTA, GA 30326 (770) 548-8268 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: G-1 FCD .I& /-\ im \ * TYPE HS TYPE 2—YA-2 TYPE XA TYPE YA-2 TYPE GY Z:� F44 TYPE NO TYPE SS TYPE OR WIRE SIZE BURNDY LUG BOLT SIZE #6 AWG GREEN INSULATED YA6C-2TC38 3/8" — 16 NO S 2 BOLT #2 AWG SOLID TINNED YA3C-2TC38 3/8" — 16 NO S 2 BOLT #2 AWG STRANDED YA2C-2TC38 3/8" — 16 NO S 2 BOLT #2/0 AWG STRANDED YA26-2TC38 3/8" — 16 NO S 2 BOLT #4/0 AWG STRANDED BURNDY YA28-2N GROUND LUG W/ 1/2" — 16 NO S 2 BOLT TYPE VS TYPE VB TYPE PT TYPE GT' NOTE: 1. ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. 2. MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD. CADWELD GROUNDING CONNECTIONS SCALE: NOT TO SCALE WEATHERPROOFING KIT (SEE NOTE 3) ANTENNA CABLE #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR). SEE NOTE 1 & 2 CABLE GROUND KIT CABLE CONNECTOR NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO—PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. CABLE GROUND KIT CONNECTION 3 SCALE: NOT TO SCALE 3/8-11x1" TAMPER RESISTANT BOLT (TYP) INSULATORS SEE NOTE 2. (TYP) TO ANTENNAS COAX JUMPER (TYP.) CONNEC WEATHERPROOFING (TYP. SEE Nor[ ANTENNA CA TO BTS EQUIPMENT (T WEATHERPROOFING KIT (TYR) GROUND KIT (TYR) #6 AWG COPPER/GALVANIZED COAX GROUND BAR BONDED DIRECTLY TOWER LONG BARREL HEAT SHRINK (SEE CHART) (CLEAR) NUT GROUNDING (TYE) CONDUCTOR LOCK WASHER (TYP) GROUND BAR BOLT (SEE CHART) (TYR) BURNDY TWO HOLE LUG W/ LONG BARREL (SEE CHART) BARE WIRE TO BE NO—OX AT BOTH ENDS STRANDED (GREEN INSULATED) ONLY FOR #6 AWG (SEE CHART) NOTES: 1. ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. /---\ MECHANICAL LUG CONNECTION � SCALE: NOT TO SCALE #6 AWG MIN. FROM ANTENNA CABLE GROUND KIT NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. GROUND BAR ON SHELTER. ICE 2. WEATHER PROOFING SHALL BE TWO—PART TAPE KIT. COLD SHRINK SHALL NOT BE BRIDGE, OR ON ANTENNA TOWER USED. GROUND CABLE CONNECTION SCALE: NOT TO SCALE *TWO HOLE LUG, OR EXOTHERMIC WELD TO BE USED WITH #2 AWG BARE CONDUCTOR WIRE TO BUILDING SERVICE GROUND OR GROUND RING o WALL BRACKET (TYP) ® ® NOTE: MINIMUM OF S/S NUT ® ® ® ® 3 THREADS TO BE VISIBLE (TYR) (TYR) ® S/S SPLIT L9 ® WASHER O ® 2 HOLE LONG (TYR) #2 TINNE ® ® UNIVERSAL COPPER BARREL TINNED SOLID COPPER CONDU ® GROUND BAR (4%20") LUG S/S FLAT v (TYP) WASHER TERMIN/ LOCK WASHER ® (TYE) THE L P/N M10 (TYP) TWO —HOLE COMPRESSION LUG TIN COATED SOLID NOTES: COPPER BUS BAR S/S FLAT WASHER 1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE (TYR) USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY GAS—STD-10091. NO CHERRY INSULATOR INSTALLED IF REQUIRED MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, S/S BOLT CAD —WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. (TYR) 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. GROUND BAR DETAIL SCALE: NOT TO SCALE LUG DETAIL SCALE: NOT TO SCALE GROUNDWIRE INSTALLATION SCALE: NOT TO SCALE GROUNDING SHALL BE ELIMINATED WHEN GROUND BAR IS ELECTRICALLY BONDED TO METAL TOWER 6696 TRI COUNTY PARKWAY, SUITE 100 SCHERTZ, TX 78154 CCCROWN CASTLE 1220 AUGUSTA DRIVE, SUITE 500 HOUSTON, TX 77057 BROADUS� services 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 OFFICE: (817) 349 3449 FAX: 800 4014234 VERIZON SITE NUMBER: 295251 BU #: 876558 F3 - COPPELL MIDDLE S 1305 WRANGLER CIRCLE COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DAWN DESCRIPTION DES./Q CDO 05/17/2021 ND PRELIMINARY SN PCDO 08/10/2021 ND FINAL. SN FCD1 08/12/2021 ND FINAL SN CD2 09/13/2021 ND FINAL. SN �r'%>%, F. rE1�l op . .. ...... ... . . .... .. 1 21 4 3 0 Ns�•C5�2��r FIRM #: 19170 CAA SOLUTIONS, PLLC CONSULTING ENGINEER 3400 STRATFORD ROAD ATLANTA, GA 30326 (770) 548-8268 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: G-2 FCD )I ES MOUNT MODIFICATION DRAWINGS PROPOSED CARRIER: VERIZON verizon TOWER OWNER: CROWN CASTLE TOWER OWNER SITE #: 876558 CARRIER SITE NUMBER: 295251-VZW CARRIER SITE NAME: WRANGLER COORDINATES (LATITUDE: 32.934811 °, LONGITUDE:-97.001622°) dw FUZE ID # 16226318 10177 Planning Administrative Approval coPPEi% 12/03/2021 c SGN-1 GENERAL NOTES 0 0 o� w F— N 0 T 0 U Contractor PMI Requirements SHEET SHEET TITLE REV ST-1 TITLE SHEET 0 PMI Accessed At https://pmi.vzwsmart.com SBOM BILL OF MATERIALS 0 Smart Tool Vendor Project 10078301 Post MOD Analysis Report SCF-1 CLIMBING FACILITY DETAILS 0 10078301 Number Project Number SS-1 ANTENNA MOUNT MODIFICATION DETAILS 0 SS-2 MOUNT PHOTOS 0 VzW Location Code (PSLC) 295251 Report Dated 07/07/2021 SPECIFICATION SHEETS *** PMI and Requirements embedded in Mount Analysis Report VzW APPROVED SMART KIT VENDORS 0 Refer to Mount Modification Drawings Page for VzW SMART KIT Approved Vendors - Tower Engineering Solutions 1320 GREENWAY DRIVE, SUITE 600 IRVING, TX 75038 PH: 972 483-0607 TES JOB NO- 10078301 CUSTOMER SITE N0: 295251—VZW CUSTOMER SITE NAME: WRANGLER 1305 WRANGLER CIRCLE COPPELL, TX 75019 TOWER ENGINEERING SOLUTIONS, LLC TEXAS REGISTERED ENGINEERING FIRM F-15688 Exp.og/3o/aoai s� o /o /aoai )RAWN BY,BS CHECKED BY: KSP/SK REV. DESCRIPTION BY DATE FIRST ISSUE BS 07 07 21 0 0 SHEET TITLE: TITLE SHEET This drawing document is the property of Tower Engineering Solutions, LLC. Information contained herein is considered confidential in nature and is to be used only for the specific site that it was intended for. Reproduction, transmission, publication or disclosure by any method is prohibited except by express written permission from Tower Engineering Solutions, LLC. Without exception, the information on this drawing document remains the property of Tower Engineering Solutions, LLC. SHEET NUMBER: REV #: ST-1 0 SGN-1 GENERAL NOTES 0 0 o� w F— N 0 T 0 U Contractor PMI Requirements SHEET SHEET TITLE REV ST-1 TITLE SHEET 0 PMI Accessed At https://pmi.vzwsmart.com SBOM BILL OF MATERIALS 0 Smart Tool Vendor Project 10078301 Post MOD Analysis Report SCF-1 CLIMBING FACILITY DETAILS 0 10078301 Number Project Number SS-1 ANTENNA MOUNT MODIFICATION DETAILS 0 SS-2 MOUNT PHOTOS 0 VzW Location Code (PSLC) 295251 Report Dated 07/07/2021 SPECIFICATION SHEETS *** PMI and Requirements embedded in Mount Analysis Report VzW APPROVED SMART KIT VENDORS 0 Refer to Mount Modification Drawings Page for VzW SMART KIT Approved Vendors - Tower Engineering Solutions 1320 GREENWAY DRIVE, SUITE 600 IRVING, TX 75038 PH: 972 483-0607 TES JOB NO- 10078301 CUSTOMER SITE N0: 295251—VZW CUSTOMER SITE NAME: WRANGLER 1305 WRANGLER CIRCLE COPPELL, TX 75019 TOWER ENGINEERING SOLUTIONS, LLC TEXAS REGISTERED ENGINEERING FIRM F-15688 Exp.og/3o/aoai s� o /o /aoai )RAWN BY,BS CHECKED BY: KSP/SK REV. DESCRIPTION BY DATE FIRST ISSUE BS 07 07 21 0 0 SHEET TITLE: TITLE SHEET This drawing document is the property of Tower Engineering Solutions, LLC. Information contained herein is considered confidential in nature and is to be used only for the specific site that it was intended for. Reproduction, transmission, publication or disclosure by any method is prohibited except by express written permission from Tower Engineering Solutions, LLC. Without exception, the information on this drawing document remains the property of Tower Engineering Solutions, LLC. SHEET NUMBER: REV #: ST-1 0 Tower Engineering Solutions 1320 GREENWAY DRIVE, SUITE 600 IRVING, TX 75038 PH: 972 483-0607 TES JOB NO- 10078301 CUSTOMER SITE N0: 295251—VZW CUSTOMER SITE NAME: WRANGLER 1305 WRANGLER CIRCLE COPPELL, TX 75019 TOWER ENGINEERING SOLUTIONS, LLC TEXAS REGISTERED ENGINEERING FIRM F-15688 Exp.og/3o/aoai s� o /o /aoai )RAWN BY,BS CHECKED BY: KSP/SK REV. DESCRIPTION BY DATE FIRST ISSUE BS 07 07 21 0 0 SHEET TITLE: TITLE SHEET This drawing document is the property of Tower Engineering Solutions, LLC. Information contained herein is considered confidential in nature and is to be used only for the specific site that it was intended for. Reproduction, transmission, publication or disclosure by any method is prohibited except by express written permission from Tower Engineering Solutions, LLC. Without exception, the information on this drawing document remains the property of Tower Engineering Solutions, LLC. SHEET NUMBER: REV #: ST-1 0 BILL OF MATERIALS QUANTITY COUNTED QUANTITY PROVIDED PART NUMBER DESCRIPTIONS SHEET LIST PIECE WEIGHT (LBS) WEIGHT(LB) NOTES MATERIAL& HARDWARE 1 1 VZWSMART-PLK7 MONOPOLE COLLAR MOUNTASSEMBLY A-1, VZWSMART-PLK7 150.0 150.0 Galvanized 3 3 VZWSMART-PLK6 V-BRACING KIT FOR MONOPOLE A-1, VZWSMART-PLK6 109.0 327.0 Galvanized FOLLOWING ITEMS ARE"CUSTOM" PARTS 3 3 PST2875-10 2 1/2" PST (2.875" O.D. X 0.203" THK) X 10'-0" A53 GR-B 35KSI SS-1 59.31 177.9 GALVANIZED 3 3 PV-XP-2530-HD PERFECTVISION CROSSOVER CHANNEL BRACKET SS-1 12.50 37.5 GALVANIZED 3 3 PV-XA-U PERFECT VISION CROSSOVER ANGLE SS-1 9.00 27.0 GALVANIZED 2 2 PN 115-203 SAFETY CABLE GUIDE (TUF-TUG OR EQUIV.) SCF-1 0.00 0.0 GALVANIZED TOTAL WEIGHT (LBS)= 719.4 VzW Mount Modification Kits - Approved Vendors PerfectVision Metrosite Fabricators, LLC Sabre Industries Inc Contact: Wireless Sales wirelesssales@perfect-vision.com Phone Number 844.887.6723 Website www.perfect-vision.com Contact: Kent Ramey kent@metrositellc.com Phone Number (0) 706.335.7045 (M) 706.982.9788 Website metrositefabricators.com Contact: Angie Welch akwelch@sabreindustries.com Phone Number 866.428.6937 Website www.sabresitesolutions.com SiteProl CommScope Contact: Paula Boswell Paula.boswell@vaImont.com Phone Number 972.236.9843 Website www.siteprol.com Contact: Salvador Anguiano Salvador.Anguiano@commscope.com Phone Number 817.304.7492 Website www.commscope.com The manufacturers listed are the approved vendors for the VzW Mount Kits. Each manufacturer will be aware of which kits have been through the VzW approval process and they are in turn approved to sell. Please note that the material utilized on the mount modifications will be reviewed as a part of the Desktop PMI completed by the SMART tool vendor. It will be required that the VzW kits specified are utilized in the modification. All materials required for the designed modifications but not list in this sheet are assumed to be provided by the contractor. All parts are galvanized unless noted otherwise. ►►I ES Tower Engineering Solutions 1320 GREENWAY DRIVE, SUITE 600 IRVING, TX 75038 PH: 972 483-0607 verizon TES JOB NO- 10078301 CUSTOMER SITE NO: 295251—VZW CUSTOMER SITE NAME: WRANGLER 1305 WRANGLER CIRCLE COPPELL, TX 75019 TOWER ENGINEERING SOLUTIONS, LLC TEXAS REGISTERED ENGINEERING FIRM F-15688 Planning Administrative Approval COFFEii 12/03/2021 DRAWN BY:BS CHECKED BY: KSP/SK REV. DESCRIPTION BY DATE AO FIRST ISSUE BS 07 07 21 0 0 0 0 SHEET TITLE: BILL OF MATERIALS This drawing/document is the property of Tower Engineering Solutions, LLC. Information contained herein is considered confidential in nature and is to be used only for the specific site that it was intended for. Reproduction, transmission, publication or disclosure by any method is prohibited except by express written permission from Tower Engineering Solutions, LLC. Without exception, the information on this drawing/document remains the property of Tower Engineering Solutions, LLC. SHEET NUMBER: RED/ #: SBOM 0 GENERAL NOTES 1. ALL WORK SHALL COMPLY WITH THE ANSI/TIA-222—H, ANSI/ASSP A10.48, AND ANY OTHER GOVERNING BUILDING CODES AND OSHA SAFETY REGULATIONS. 2. ALL WORK INDICATED ON THE DRAWINGS SHALL BE PERFORMED BY QUALIFIED CONTRACTORS EXPERIENCED IN TELECOMMUNICATIONS TOWER, POLE AND FOUNDATION CONSTRUCTION. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND FABRICATION OF ALL MISCELLANEOUS PARTS (SUCH AS SHIMS), TEMPORARY SUPPORTS, AND GUYINGS, ETC., PER ANSI/ASSP A10.48, TO COMPLETE THE ASSEMBLY AS SHOWN IN THE DRAWINGS. 4. CONTRACTOR SHALL PROCEED WITH THE INSTALLATION WORK CAREFULLY SO THE WORK WILL NOT DAMAGE ANY EXISTING CABLE, EQUIPMENT OR THE STRUCTURE. 5. THE USE OF GAS TORCH OR WELDER, ARE NOT ALLOWED ON ANY TOWER STRUCTURE WITHOUT THE CONSENT OF THE TOWER OWNER. 6. GENERALLY THE CONTRACTOR IS RESPONSIBLE TO CONDUCT AN ONSITE VISIT SURVEY OF THE JOB SITE AFTER AWARD, AND REPORT ANY ISSUES WITH THE SITE TO TES BEFORE PROCEEDING CONSTRUCTION. 7. TEMPORARILY RELOCATE ANY EXISTING COAX ATTACHED TO THE LEGS AND/OR ANY OTHER MEMBERS WHERE OBSTRUCTION WITH THE PROPOSED MODIFICATION MAY OCCUR. 8. IT IS THE RESPONSIBILITY OF THE GC TO VERIFY THAT THERE IS NO INTERFERENCES (WITH SAFETY CLIMB BRACKETS, TRANSMISSION LINES, ETC.) PRIOR TO MOBILIZATION AND INSTALLATION OF THESE MODIFICATIONS. 9. PLEASE NOTIFY TES IMMEDIATELY IF ANY INSTALLATION ISSUES OCCUR RELATED TO THIS DRAWING @ 972-483-0607 OR EMAIL—TESORDERS@TESTOWER.US FABRICATION 1. ALL STEEL SHALL MEET OR EXCEED THE MINIMUM STRENGTH AS SPECIFIED IN THE DRAWINGS. IF YIELD STRENGTH WAS NOT NOTED IN THE DRAWINGS, CONTRACTORS SHALL CONTACT TES FOR DIRECTION. 2. ALL FIELD CUT EDGES SHALL BE GROUND SMOOTH. ALL FIELD CUT AND DRILLED SURFACES SHALL BE REPAIRED WITH A MINIMUM OF TWO COATS OF ZINGA COLD GALVANIZING COMPOUND PER ASTM A780 AND MANUFACTURER'S RECOMMENDATIONS. WELDING 1. ALL WELDING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS AND IN ACCORDANCE WITH THE LATEST EDITION OF THE AWS WELDING CODE D1.1. ALL ELECTRODES TO BE LOW HYDROGEN, MATCHING FILLER METAL, PER AWS D1.1, UNO. (E70XX UNLESS NOTED OTHERWISE). 2. PRIOR TO FIELD WELDING GALVANIZED MATERIAL, CONTRACTOR SHALL GRIND OFF GALVANIZING APPROX. 0.5" BEYOND THE PROPOSED FIELD WELD SURFACES. 3. ALL WELDS SHALL BE INSPECTED VISUALLY. A MINIMUM OF 25% OF WELDS SHALL BE INSPECTED WITH DYE PENETRANT OR MAGNETIC PARTICLE TO MEET THE ACCEPTANCE CRITERIA OF AWS D1.1. 100% OF WELDS SHALL BE INSPECTED IF DEFECTS ARE FOUND. 4. WELD INSPECTIONS SHALL BE PERFORMED BY AN AWS CERTIFIED WELD INSPECTOR. 5. AFTER INSPECTION, ALL FIELD WELDED SURFACES SHALL BE REPAIRED WITH A MINIMUM OF TWO COATS OF ZINGA COLD GALVANIZING COMPOUND PER ASTM A780 AND MANUFACTURER'S RECOMMENDATIONS. BOLTED ASSEMBLIES AND TIGHTENING OF CONNECTIONS 1. ALL HIGH STRENGTH BOLTS SHALL CONFORM TO THE PROVISIONS OF THE SPECIFICATIONS FOR STRUCTURAL JOINTS USING A325 OR A490 BOLTS AS APPROVED BY THE RCSC. 2. FLANGE BOLTS SHALL BE TIGHTENED BY THE AISC "TURN —OF —THE —NUT" METHOD. THE FOLLOWING TABLE SHOULD BE USED FOR THE "TURN —OF —THE —NUT" TIGHTENING. 3. SPLICE BOLTS AND ALL OTHER BOLTS IN BEARING TYPE CONNECTIONS SHALL BE TIGHTENED TO A SNUG —TIGHT CONDITION. 4. THE SNUG —TIGHT CONDITION IS DEFINED AS THE TIGHTNESS ATTAINED BY EITHER A FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT OF AN IRONWORKER WITH AN ORDINARY SPUD WRENCH TO BRING THE CONNECTED PLIES INTO FIRM CONTACT. VERIFICATION AND INSPECTION 1. IF APPLICABLE, VERIFICATION INSPECTION TO BE PERFORMED SHALL BE IN ACCORDANCE TO IBC-2018 SECTION 1705.2 FOR STEEL CONSTRUCTION AND TABLE 1705.3 FOR CONCRETE CONSTRUCTION. TYPICAL BOLT ASSEMEBLY BOLT FLAT WASHER LOCK WASHER NUT NOTES 1. ALL DIMENSIONS REPRESENTED IN THIS SHEET ARE AISC MINIMUM REQUIREMENTS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS IN FIELD AND NOTIFY ENGINEER IF DISTANCES ARE LESS THAN THOSE PROVIDED. 2. THE DIMENSIONS PROVIDED ARE MINIMUM REQUIREMENTS. ACTUAL DIMENSIONS OF PROPOSED MEMBERS WITHIN THESE DRAWINGS MAY VARY FROM THE AISC MINIMUM REQUIREMENTS. 3. SHORT SLOT HOLES SHALL ONLY BE USED WHEN DEPICTED IN THE DRAWINGS. 4. MATCH EXISTING GAGES WHEN APPLICABLE, UNLESS MINIMUM EDGE DISTANCE ARE COMPROMISED. TABLE 8.2 NUT ROTATION FROM SNUG —TIGHT CONDITION FOR TURN —OF —NUT PRETENSION ING DISPOSITION OF OUTER FACE OF BOLTED PARTS ONE FACE NORMAL TO BOTH FACES SLOPED BOLT LENGTH` BOTH FACES BOLT AXIS, OTHER NOT MORE THAN 1:20 NORMAL SLOPED NOT MORE THAN FROM NORMAL TO BOLT BOLT AXIS 1:20 AXIS d NOT MORE THAN 1/3 TURN 1/2 TURN 2/3 TURN 4db MORE THAN 4d6 BUT NOT MORE 1/2 TURN 2/3 TURN 5/6 TURN THAN 8db MORE THAN 8db BUT NOT MORE 2/3 TURN 5/6 TURN 1 TURN THAN 12db ° NUT ROTATION IS RELATIVE TO BOLT REGARDLESS OF THE ELEMENT (NUT OR BOLT) BEING TURNED. FOR REQUIRED NUT ROTATIONS OF 1/2 TURN AND LESS, THE TOLERANCE IS PLUS OR MINUS 30 DEGREES; FOR REQUIRED NUT ROTATIONS OF 2/3 TURN AND MORE, THE TOLERANCE IS PLUS OR MINUS 45 DEGREES. b APPLICABLE ONLY TO JOINTS IN WHICH ALL MATERIAL WITHIN THE GRIP IS STEEL. ° WHEN THE BOLT LENGTH EXCEEDS 12db, THE REQUIRED NUT ROTATION SHALL BE DETERMINED BY ACTUAL TESTING IN A SUITABLE TENSION CALIBRATOR THAT SIMULATES THE CONDITIONS OF SOLIDLY FITTING STEEL. d BEVELED WASHER NOT USED. SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS, JUNE 30, 2004 RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS NOMINAL HOLE DIMENSIONS BOLT DIAMETER STANDARD HOLE SHORT LOT 1/2" 9/16" 9/16" X 11/16" 5/8" 11/16" 11/16 X 7/8" 3/4" 13/16" 13/16" X 1" 7/8" 15/16" 15/16" X 1 1/8" 1" 1 1/16" 1 1/16" X 1 5/16" BOLT EDGE AND SPACING BOLT DIAMETER MIN EDGE SPACING MIN. _ EDGE 1/2» 7/8" 1 1/2" 5/8" 1 1/8" 1 7/8" 3/4" 1 1/4" 2 1/4" 7/8" 1 1 1/2" 1 2 5/8" 1 " 1 1 3/4„ 1 3„ WORKABLE GAGES ANGLE SIZE GAGE G! AGE 1 1 3/4" 1" 2' 1 1/8" 2 1/2" 1 3/8" 3" 1 3/4" 3 1/2" 2' 4' 2 1/2" WORKABLE GAGES 1.5 X L LIMIT OF ALLOWABLE COPED (MAX) S PORTION OF ANGLE WITHOUT ENGINEERS PRIOR WRITTEN ­�,E::ll APPROVAL J �11 ES Tower Engineering Solutions 1320 GREENWAY DRIVE, SUITE 600 IRVING, TX 75038 PH: 972 483-0607 verizon TES JOB N0: 10078301 CUSTOMER SITE NO: 295251—VZW CUSTOMER SITE NAME: WRANGLER 1305 WRANGLER CIRCLE COPPELL, TX 75019 TOWER ENGINEERING SOLUTIONS, LLC TEXAS REGISTERED ENGINEERING FIRM F-15688 Planning Administrative Approval COFFEii 12/03/2021 DRAWN BY:BS CHECKED BY: KSP/SK REV. DESCRIPTION BY DATE AO FIRST ISSUE BS 07 07 21 0 0 SHEET TITLE: GENERAL NOTES This drawing/document is the property of Tower Engineering Solutions, LLC. Information contained herein is considered confidential in nature and is to be used only for the specific site that it was intended for. Reproduction, transmission, publication or disclosure by any method is prohibited except by express written permission from Tower Engineering Solutions, LLC. Without exception, the information on this drawing/document remains the property of Tower Engineering Solutions, LLC. SHEET NUMBER: REV #: SIGN 0 1 LOCATION OF SAFETY CLIMB SCF-1 NOTE: 1. INSTALL SHALL NOT CAUSE HARM TO THE STRUCTURE, CLIMBING FACILITY, SAFETY CLIMB OR ANY SYSTEM INSTALLED ON THE STRUCTURE. EXISTING OR NEN EXISTING MONC Ti NEW SAFETY CLIMB CAE GUIDE (PART# PIN 115-21 (TUF-TUG OR EQU EXISTING SAFETY CL CAE COLLAR MO�INI THREADED ROD PICTURE OF SAFETY CLIMB 2 DETAIL SCF-1 LOCATION OF _IMB �11 ES Tower Engineering Solutions 1320 GREENWAY DRIVE, SUITE 600 IRVING, TX 75038 PH: 972 483-0607 verizon TES JOB N0: 10078301 CUSTOMER SITE NO: 295251—VZW CUSTOMER SITE NAME: WRANGLER 1305 WRANGLER CIRCLE COPPELL, TX 75019 TOWER ENGINEERING SOLUTIONS, LLC TEXAS REGISTERED ENGINEERING FIRM F-15688 Planning Administrative Approval COPPELL 12/03/2021 DRAWN BY:BS CHECKED BY: KSP/SK REV. DESCRIPTION BY DATE FIRST ISSUE BS 07 07 21 0 0 SHEET TITLE: CLIMBING FACILITY This drawing/document is the property of Tower Engineering Solutions, LLC. Information contained herein is considered confidential in nature and is to be used only for the specific site that it was intended for. Reproduction, transmission, publication or disclosure by any method is prohibited except by express written permission from Tower Engineering Solutions, LLC. Without exception, the information on this drawing/document remains the property of Tower Engineering Solutions, LLC. SHEET NUMBER: REV #: SCF-1 0 �I J 0 n c ISOMETRIC VIEW EXISTING ANTENNA MOUNT @ 55' ELEV. 11 MOUNT MODIFICATION SCHEDULE SL. NO. MOUNT MODIFICATION DESCRIPTION REFERENCE SHEET NO. REPLACE EXISTING ANTENNA MOUNT PIPE WITH 2 1 2 PST PIPE PST2875-10 , 1 PER SECTOR. SS-1 2 INSTALL NEW PERFECT VISION CROSSOVER CHANNEL BRACKET (PV-XP-2530-HD) PV-XP-2530-HD 3 INSTALL NEW PERFECT VISION CROSSOVER ANGLE (PV-XA-U) E-1/PV-XA-U INSTALL NEW VZWSMART MONOPOLE COLLAR MOUNT ASSEMBLY VZWSMART-PLK7 INSTALL NEW VZWSMART V-BRACING KIT TO MONOPOLE VZWSMART-PLK6 6 INSTALL NEW SAFETY CLIMB GUIDE SCF-1 FIELD CUTTING AND FIELD DRILLING MAY BE NECESSARY TO ACHIEVE THE REQUIRED DIMENSIONS TEE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEAN-UP, REMOVAL AND DISPOSAL OF EXCESS MATERIALS EL AND REMOVED FROM THE STRUCTURE AT THE COMPLETION OF THE PROJECT. MEMBERS IN BLUE COLOR ARE NEW REINFORCEMENTS AND MEMBERS IN AQUA COLOR (IF SHOWN) ARE RELOCATED MEMBERS Z)iUL Vitw )I ES Tower Engineering Solutions 1320 GREENWAY DRIVE, SUITE 600 IRVING, TX 75038 PH: 972 483-0607 verizon TES JOB N0: 10078301 CUSTOMER SITE NO: 295251—VZW CUSTOMER SITE NAME: WRANGLER 1305 WRANGLER CIRCLE COPPELL, TX 75019 TOWER ENGINEERING SOLUTIONS, LLC TEXAS REGISTERED ENGINEERING FIRM F-15688 Planning Administrative Approval COPPELL 12/03/2021 DRAWN BY:BS CHECKED BY: KSP/SK REV. DESCRIPTION BY DATE FIRST ISSUE BS 07 07 21 0 0 SHEET TITLE: ANTENNA MOUNT MODIFICATION DETAILS This drawing/document is the property of Tower Engineering Solutions, LLC. Information contained herein is considered confidential in nature and is to be used only for the specific site that it was intended for. Reproduction, transmission, publication or disclosure by any method is prohibited except by express written permission from Tower Engineering Solutions, LLC. Without exception, the information on this drawing/document remains the property of Tower Engineering Solutions, LLC. SHEET NUMBER: REV #: SS-1 0 hOE- EXISTING RRUS/EQUIPMENT MAY BE RELOCATED ALONG THE MEMBER TO ACCOMMODATE THE INSTALLATION OF NEW MOUNT MODIFICATION 4 EXISTING ANTENNA MOUNT ® 55' ELEV PHOTO 1 PHOTO 2 1" _i o e o c w oRa . N PHOTO 3 PHOTO 4 T o U �)I ES Tower Engineering Solutions 1320 GREENWAY DRIVE, SUITE 600 IRVING, TX 75038 PH: 972 483-0607 verizon TES JOB NO- 10078301 CUSTOMER SITE NO: 295251—VZW CUSTOMER SITE NAME: WRANGLER 1305 WRANGLER CIRCLE COPPELL, TX 75019 TOWER ENGINEERING SOLUTIONS, LLC TEXAS REGISTERED ENGINEERING FIRM F-15688 Planning Administrative Approval COPPELL 12/03/2021 DRAWN BY:BS CHECKED BY: KSP/SK REV. DESCRIPTION BY DATE AFIRST ISSUE BS 07 07 21 0 0 A SHEET TITLE: MOUNT PHOTOS This drawing/document is the property of Tower Engineering Solutions, LLC. Information contained herein is considered confidential in nature and is to be used only for the specific site that it was intended for. Reproduction, transmission, publication or disclosure by any method is prohibited except by express written permission from Tower Engineering Solutions, LLC. Without exception, the information on this drawing/document remains the property of Tower Engineering Solutions, LLC. SHEET NUMBER: REV #: SS-2 0 THE FOLLOWING DRAWINGS ARE INCLUDED FOR REFERENCE ONLY PLEASE REFER TO THE INSTALLATION DRAWINGS FOR ACTUAL INSTALLATION DETAILS CROSS OVER CHANNEL BRACKET CROSS OVER CHANNEL BRACKET WEIGHT: SEE TABLE 1 2 TOP VIEW 7 1/2" PIPE 1 SEE TABLE 1 SIDE VIEW TABLE 1: PIPE COMPATABILITY PART# PIPE 1 SIZE PIPE 2 SIZE WEIGHT PV-XP-2030-HD 2-3/8" OD 3-1/2" OD 12.5 LBS PV-XP-2530-HD 2-7/8" OD 3-1/2" OD 12.5 LBS PV-XP-3030-HD 3-1/2" OD 3-1/2" OD 12.5 LBS PV-XP-3040-HD 3-1/2" OD 4-1/2" OD 12.5 LBS PfiRFECrV6M1 M A N U h A G: 1 u n r N G 16101 La Grande Dr. Little Rock, AR 72223 (630)-201-4012 STAMP: Planning Administrative Approval COPPELL `� , 12/03/2021 The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly prohibited. REVISIONS: to � a � Y = Q U Z } O m w a w J Z 0 LU n J Of a U m z o w Q 0 0 SITE INFORMATION: DESIGN TYPE: CROSS OVER CHANNELBRACKET SHEET TITLE: ENGINEERING DETAIL SHEET TITLE: REVISION: E-1 Q PV-XA I PV-XA-2020 PIPE COMPATIBILITY: SEE TABLE 1 WEIGHT: 6.5 LBS qn PV-XAU-2 PIPE COMPATIBILITY: SEE TABLE 1 WEIGHT: 7.8 LBS In PV-XA-U PIPE COMPATIBILITY: SEE TABLE 1 WEIGHT: 9.0 LBS TABLE 1: PIPE COMPATIBILITY PART# I PIPE 1 COMPATIBILITY PIPE 2 COMPATIBILITY WEIGHT PV-XA-2020 2-3/8" OD 2-3/8" OD 6.5 LBS PV-XAU-2 2-3/8" OD UP TO 4" OD 7.8 LBS PV-XA-U UP TO 4" OD UP TO 4" OD 9.0 LBS F&qFECTVi RM.. I'dA I'dU h A G: 1 u n r N G I 16101 La Grande Dr. Little Rock, AR 72223 (630)-201-4012 STAMP: Planning Administrative Approval COPPELL 12/03/2021 The information contained in this set of documents is proprietary by nature. any use or disclosure other than that which relates to the client named is strictly prohibited. REVISIONS: U � a � Y = Q U Z o m w a w J Z 0 uJ n J Of a U m z o w Q 0 0 SITE INFORMATION: DESIGN TYPE: CROSSOVER ANGLE SHEET TITLE: ENGINEERING DETAIL SHEET TITLE: REVISION: E-1 Q I EXISTING MONOPOLE O O (TYP) i O O O O O O 2 3 4 5 (TYP) O O PLAN VIEW MONOPOLE COLLAR MOUNT ASSEMBLY 6" co 1 (TYP) VZWSMART-PLK7 (MONOPOLE COLLAR MOUNT ASSEMBLY) ITEM N0. QTY. PART NO. DESCRIPTION SHEET # WT 1 3 CM-1245 COLLAR MOUNT ASSEMBLY PLK7—F1 147 2 6 --- THREADED ROD 5/8" X 4'-0" A193-37 --- FRONT VIEW 3 12 FW-625 5/8" HDG USS FLAT WASHER 1 NOTES: 4 =1 LW-625 5/8" HDG LOCK WASHER --- 0 1. FIT 12" TO 45" DIA MONOPOLE. 5 1 12 NUT-625 5/8" HDG HEX NUT --- 1 2. HOT —DIPPED GALVANIZED PER ASTM A123. GALVANIZED WT 150 V9h) z V'r SMART Tool' Vendor verizon Planning Administrative Approval COPPELL 12/03/2021 DRAWN BY:BT CHECKED BY: HMA/KW REV. DESCRIPTION BY DATE FIRST ISSUE BT 05 11 20 0 0 0 0 SHEET TITLE: VZWSMART-PLK7 MONOPOLE COLLAR MOUNT ASSEMBLY SHEET NUMBER: REV #: VZWSMART-PLK7 Q V'r SMART Tool' Vendor verizon Planning Administrative Approval COPPELL 12/03/2021 DRAWN BY:BT CHECKED BY: HMA/KW REV. DESCRIPTION BY DATE FIRST ISSUE BT 05 11 20 0 0 0 0 SHEET TITLE: VZWSMART-PLK7 MONOPOLE COLLAR MOUNT ASSEMBLY SHEET NUMBER: REV #: VZWSMART-PLK7 Q VZWSMART MONOPOLE COLLAR M� ASSEMBLY. (NOT INCLUDED IN THIS EXISTING MONO 0 6 (TYP) (TYP) 8 9 10 /Tvn\ . 4r (TYP) V—BRACING TO BE FIELD CUT AND DRILLED AS PER DETAIL "A" q 111, V "SEE INSTALLATION DRAWING" "SEE INSTALLATION DRAWING" V—BRACING KIT FOR MONOPOLE PLAN VIEW (TYP) FIELD CUT & TRIM TO MATCH THE REQUIRED LENGTH O O 2 EXISTING MONOPOLE V—BRACING KIT — VERTICAL (OPTION-2) SIDE VIEW NOTES: 1. HOT —DIPPED GALVANIZED PER ASTM A123. SUPPORT RAIL (FIT 1.66" TO 4.5" O.D. PIPE) (NOT INCLUDED IN THIS KIT) V—BRACING KIT — HORIZONTAL (OPTION-1) SIDE VIEW FIELD DRILL 11/16" DIA. HOLE FRONT VIEW DETAIL "A" 1 1/8" N N M nnnr it nrnURED. KISTING ANTENNA OUNT PIPE UPPORT RAIL (FIT 1.66" TO 4.5" O.D. PIPE) (NOT INCLUDED IN THIS KIT) �J (TYP) 5 8 9 10 (TYP) 3 (NP) EXISTING ANTENNA MOUNT PIPE SUPPORT RAIL (FIT 1.66" TO 4.5" O.D. PIPE) (NOT INCLUDED IN THIS KIT) VZWSMART—PLK6 (V—BRACING KIT FOR MONOPOLE) ITEM N0.PART QTY. NO. DESCRIPTION SHEET # WT 1 1 BRKW-6A WELDMENT BRACKET PLK6—F1 16 2 2 L252525-8 L 2 1/2" X 2 1/2" X 1/4" X 8'-0" A36 PLK6—F2 67 3 L BP6875-10 PL 3/8" X 6 7/8" X 10" A36 BENT PLATE PLK6—F2 20 4 2 AL—333 L 3" X 3" X 1 /4" X 3" A36 PLK6 5 4 THREADED ROD 5/8" DIA. X 10" F1554-36 HDG -F2 6 5 — — — BOLT 5/8" X 2 1 /4" A325 7 4 — — — BOLT 5/8" X 1 3/4" A325 — — — -- 8 17 FW-625 5/8" HDG USS FLAT WASHER — — — 2 9 17 LW-625 5/8" HDG LOCK WASHER --- 0 10 17 NUT-625 5/8" HDG HEX NUT --- GALVANIZED WT 109 Vzw SMART Tool' Vendor Planning Administrative Approval COPFELL '(-7 e 12/03/2021 DRAWN BY: FL CHECKED BY: KL/BT REV. DESCRIPTION BY DATE FIRST ISSUE FL 04 13 21 0 ZAI 0 SHEET TITLE: VZWSMART-PLK6 V-BRACING KIT FOR MONOPOLE SHEET NUMBER: REV #: VZWSMART-PLK6 Q