Loading...
T-MOBILE, DA01305B, ATC 309143 (13739441) AE(CD).REV0.ADM_APP.120421SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.G-001 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. DATE DRAWN:10/26/21 ATC JOB NO: HACKBERRY SPECTRA TX0152CUSTOMER ID: 13739441_G5 DA01305BCUSTOMER #: 309143 ATC SITE NAME: IRVING-HACKBERRY HACKBERRY SPECTRA TX0152 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 TITLE SHEET A PRELIM VS 10/26/21 0 FINALS TR 12/06/21 0 LOCATION MAPVICINITY MAP COMPLIANCE CODE PROJECT SUMMARY PROJECT DESCRIPTION UTILITY COMPANIES SHEET INDEX SHEET NO:DESCRIPTION:REV:DATE:BY: G-001 TITLE SHEET 0 12/06/21 TR G-002 GENERAL NOTES 0 12/06/21 TR C-101 DETAILED SITE PLAN 0 12/06/21 TR C-102 DETAILED GROUND PLAN 0 12/06/21 TR C-201 TOWER ELEVATION 0 12/06/21 TR C-401 ANTENNA INFORMATION & SCHEDULE 0 12/06/21 TR C-501 CONSTRUCTION DETAILS 0 12/06/21 TR E-501 GROUNDING DETAILS 0 12/06/21 TR R-601 SUPPLEMENTAL R-602 SUPPLEMENTAL R-603 SUPPLEMENTAL R-604 SUPPLEMENTAL POWER COMPANY: TXU PHONE: (800) 242-9113 TELEPHONE COMPANY: SBC PHONE: (800) 559-7928 ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1.INTERNATIONAL BUILDING CODE (IBC) 2.NATIONAL ELECTRIC CODE (NEC) 3.LOCAL BUILDING CODE 4.CITY/COUNTY ORDINANCES SITE LOCATION T-MOBILE ANCHOR ANTENNA AMENDMENT PLAN 56791EZ_SR_U21 CONFIGURATION SITE ADDRESS: 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 COUNTY: DALLAS 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 GEOGRAPHIC COORDINATES: LATITUDE: 32.95419444 LONGITUDE: -96.94186111 GROUND ELEVATION: 451' AMSL E BELT LINE RD PROJECT LOCATION DIRECTIONS FROM THE INTERSECTION OF I-635 AND I35E IN NORTHWEST DALLAS, GO NORTH ON I35E TO THE BELTLINE ROAD EXIT; TURN WEST (LEFT) ON BELTLINE AND DRIVE APPROXIMATELY 2 MILES TO 1850 BELTLINE; TURN NORTH (RIGHT) AND DRIVE OVER THE RAILROAD TRACKS TO THE METAL BUILDINGS; DRIVE NORTH ALONG THE WEST SIDE OF THE METAL BUILDINGS TO THE NORTHEND OF THE PROPERTY; SITE IS ON THE RIGHT. PROJECT TEAM APPLICANT: T-MOBILE ATTN: ANNA RUBIO 3801 S CAPITAL OF TX HWY AUSTIN, TX 78704 TOWER OWNER: AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ENGINEER: HUDSON DESIGN GROUP, LLC. 45 BEECHWOOD DRIVE NORTH ANDOVER, MA 01845 PROPERTY OWNER: AMERICAN TOWER CORPORATION 1850 E. BELTLINE ROAD COPPELL, TX 75019 ATC SITE NAME: IRVING-HACKBERRY ATC SITE NUMBER: 309143 T-MOBILE SITE NAME: HACKBERRY SPECTRA TX0152 T-MOBILE SITE NUMBER: DA01305B SITE ADDRESS:1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ELM FORK TR IN ITY R IVER THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASED AND TOWER MOUNTED EQUIPMENT AS INDICATED PER BELOW: TOWER WORK: REMOVE (3) T-ARM MOUNT(s), (12) ANTENNA(s), (6) RRH(s), (3) TMA(s), (1) LARGE COVP, (12) 7/8" COAX CABBLE(s) AND (1) 1-1/4" HYBRID CABLE INSTALL (1) PLATFORM MOUNT, (6) ANTENNA(s), (6) RRH(s), (2) HCS 2.0 BREAKOUT PANDENT(s) AND (2) HCS 2.0 TRUNK CABLE(s) GROUND WORK: REMOVE (2) EQUIPMENT CABINET(s), (1) ESMB, (2) FSME(s), (4) FSMF(s), (2) FBBA(s), (2) FBBC(s), (3) FRIA(s), (1) FXFB, (1) FXFC AND (3) FRLB(s) (3) FRBG RRU(s), (6) DIPLEXER(s), AND (1) CSR 7705 SAR A INSTALL (1) HPL3 SSC CABINET, (1) LB3 BATTERY CABINET, (2) JUNCTION BOX(s), (2) ASIB(s), (2) ASIK(s), (3) ABIA(s), (6) ABIL(s), (3) ABIC(s), (2) AMIA(s) AND (1) CSR IXRe V2 (Gen2) EXISTING (1) FSMF TO REMAIN 1.THE FACILITY IS UNMANNED. 2.A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCE A MONTH FOR ROUTINE INSPECTION AND MAINTENANCE. 3.THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LAND DISTURBANCE OR EFFECT OF STORM WATER DRAINAGE. 4.NO SANITARY SEWER, POTABLE WATER OR TRASH DISPOSAL IS REQUIRED. 5.HANDICAP ACCESS IS NOT REQUIRED. 6.THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS AN ELIGIBLE FACILITIES REQUEST ENTITLED TO EXPEDITED REVIEW UNDER 47 U.S.C. § 1455(A) AS A MODIFICATION OF AN EXISTING WIRELESS TOWER THAT INVOLVES THE COLLOCATION, REMOVAL, AND/OR REPLACEMENT OF TRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIAL CHANGE UNDER CFR § 1.61000 (B)(7). PROJECT NOTES Planning Administrative Approval 12/14/2021 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.G-002 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. DATE DRAWN:10/26/21 ATC JOB NO: HACKBERRY SPECTRA TX0152CUSTOMER ID: 13739441_G5 DA01305BCUSTOMER #: 309143 ATC SITE NAME: IRVING-HACKBERRY HACKBERRY SPECTRA TX0152 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 GENERAL NOTES A PRELIM VS 10/26/21 0 FINALS TR 12/06/21 0 GENERAL CONSTRUCTION NOTES: 1.OWNER FURNISHED MATERIALS, T-MOBILE "THE COMPANY" WILL PROVIDE AND THE CONTRACTOR WILL INSTALL A.BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE SHELTER (GROUND BUILD/CO-LOCATE ONLY) B.AC/TELCO INTERFACE BOX (PPC) C.ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILD/CO-LOCATE ONLY, GC TO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION) D.TOWERS, MONOPOLES E.TOWER LIGHTING F.GENERATORS & LIQUID PROPANE TANK G.ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTING H.ANTENNAS (INSTALLED BY OTHERS) I.TRANSMISSION LINE J.TRANSMISSION LINE JUMPERS K.TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITS L.TRANSMISSION LINE GROUND KITS M.HANGERS N.HOISTING GRIPS O.BTS EQUIPMENT 2.THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THE COMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCH MATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB-FRAME FOR PLATFORM, ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDING WIRES, COPPER-CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS AND DISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER, CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORE DRILLING, SLEEPERS AND RUBBER MATTING, REBAR, CONCRETE CAISSONS, PADS AND/OR AUGER MOUNTS, MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES AND ALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TO THE DRAWINGS AND SPECIFICATIONS. IT IS THE POSITION OF T-MOBILE TO APPLY FOR PERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIRED PERMITS. 3.ALL WORK SHALL CONFORM TO ALL CURRENT APPLICABLE FEDERAL, STATE, AND LOCAL CODES, INCLUDING ANSI/EIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTION SPECIFICATIONS. 4.CONTRACTOR SHALL CONTACT LOCAL 811 FOR IDENTIFICATION OF UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION. 5.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIRED INSPECTIONS. 6.ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, AND SITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALL DISCREPANCIES REPORTED TO THE ENGINEER. 7.DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS. 8.DETAILS SHOWN ARE TYPICAL; SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESS OTHERWISE NOTED. 9.THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 10.CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDED FOR STABILITY ARE INSTALLED. THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING, ANCHOR BOLTS, ETC. 11.CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDS DRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCING WORK. 12.INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING OR NONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE T-MOBILE REP PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH REMEDIAL ACTION SHALL REQUIRE WRITTEN APPROVAL BY THE T-MOBILE REP PRIOR TO PROCEEDING. 13.EACH CONTRACTOR SHALL COOPERATE WITH THE T-MOBILE REP, AND COORDINATE HIS WORK WITH THE WORK OF OTHERS. 14.CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THIS PROJECT TO MATCH EXISTING PRE-CONSTRUCTION CONDITIONS TO THE SATISFACTION OF THE T-MOBILE CONSTRUCTION MANAGER. 15.ALL CABLE/CONDUIT ENTRY/EXIT PORTS SHALL BE WEATHERPROOFED DURING INSTALLATION USING A SILICONE SEALANT. 16.WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET, CONTRACTOR SHALL NOTIFY THE T-MOBILE REP AND ENGINEER OF RECORD IMMEDIATELY. 17.CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETE AND CURRENT SET OF DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT. 18.CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OF EACH DAY. 19.CONTRACTOR SHALL COORDINATE WORK SCHEDULE WITH AMERICAN TOWER CORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OF OTHER OCCUPANTS OF THE FACILITY. 20.CONTRACTOR SHALL FURNISH T-MOBILE AND AMERICAN TOWER CORPORATION (ATC) WITH A PDF MARKED UP AS-BUILT SET OF DRAWINGS UPON COMPLETION OF WORK. 21.PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDED SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR WILL INSTALL ALL ITEMS PROVIDED. 22.PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR. ALL REQUIRED PERMITS NOT OBTAINED BY T-MOBILE MUST BE OBTAINED, AND PAID FOR, BY THE CONTRACTOR. 23.CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH T-MOBILE SPECIFICATIONS AND REQUIREMENTS. 24.CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO T-MOBILE FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. 25.ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS AND LOCATED ACCORDING TO T-MOBILE SPECIFICATIONS, AND AS SHOWN IN THESE PLANS. 26.THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 27.CONTRACTOR SHALL NOTIFY T-MOBILE REP A MINIMUM OF 48 HOURS IN ADVANCE OF POURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS OR SEALING ANY WALL, FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW AND APPROVAL. 28.CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY INCLUDING COMPLIANCE WITH ALL APPLICABLE OSHA STANDARDS AND RECOMMENDATIONS AND SHALL PROVIDE ALL NECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICES SUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING, TRENCH BOXES/SLOPING, BARRIERS, ETC. 29.THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES AND SUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD. ANY DAMAGE CAUSED BY NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES, OR BY THE ELEMENTS DUE TO NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HIS WORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HIS EXPENSE TO THE OWNER'S SATISFACTION. 30.ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNER BY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIP SHALL BE SUBJECT TO THE APPROVAL OF THE T-MOBILE REP. ANY WORK FOUND BY THE T-MOBILE REP TO BE OF INFERIOR QUALITY AND/OR WORKMANSHIP SHALL BE REPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL IS OBTAINED. 31.IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OF MATERIALS LISTED HEREINAFTER BY MANUFACTURER’S NAMES AND/OR MANUFACTURER’S CATALOG NUMBER SHALL BE PROVIDED BY THESE MANUFACTURERS AS SPECIFIED. 32.T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED-UP AT THE T-MOBILE WAREHOUSE, NO LATER THAN 48HR AFTER BEING NOTIFIED INSURED, STORED, UNCRATE, PROTECTED AND INSTALLED BY THE CONTRACTOR WITH ALL APPURTENANCES REQUIRED TO PLACE THE EQUIPMENT IN OPERATION, READY FOR USE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP. 33.T-MOBILE OR HIS ARCHITECT/ENGINEER RESERVES THE RIGHT TO REJECT ANY EQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITH THE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THE EQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TO T-MOBILE OR THEIR ARCHITECT/ENGINEER. SPECIAL CONSTRUCTION ANTENNA INSTALLATION NOTES: 1.WORK INCLUDED: A.ANTENNA AND COAXIAL CABLES ARE FURNISHED BY T-MOBILE UNDER A SEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA INSTALLATION CONTRACTOR IN TERMS OD COORDINATION AND SITE ACCESS. ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF PERSONNEL AND B.INSTALL ANTENNA AS INDICATE ON DRAWINGS AND T-MOBILE SPECIFICATIONS. C.INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS D.INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE AND PROVIDE PRINTOUT OF THAT TEST. E.CONTRACTOR SHALL PROVIDE FOUR (4) SETS OF SWEEP TESTS USING ANRITZU-PACKARD 8713B RF SCALAR NETWORK ANALYZER. SUBMIT FREQUENCY DOMAIN REFLECTOMETER(FDR) TESTS RESULTS TO THE PROJECT MANAGER. SWEEP TESTS SHALL BE AS PER ATTACHED RFS "MINIMUM FIELD TESTING RECOMMENDED FOR ANTENNA AND HELIAX COAXIAL CABLE SYSTEMS" DATED 10/5/93. TESTING SHALL BE PERFORMED BY AN INDEPENDENT TESTING SERVICE AND BE BOUND AND SUBMITTED WITHIN ONE WEEK OF WORK COMPLETION. F.INSTALL COAXIAL CABLES AND TERMINATING BETWEEN ANTENNAS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALL CONNECTIONS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. TERMINATE ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OF ENTRY PORT LOCATION UNLESS OTHERWISE STATED. G.ANTENNA AND COAXIAL CABLE GROUNDING: 2.ALL EXTERIOR #6 GREED GROUND WIRE "DAISY CHAIN" CONNECTIONS ARE TO BE WEATHER SEALED WITH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT #221213 OR EQUAL. 3.ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF COAXIAL CABLE (NOT WITHIN BENDS) ELECTRICAL NOTES: 1.ELECTRICAL DESIGN SHALL BE PERFORMED BY ELECTRICAL CONTRACTOR. STRUCTURAL DESIGN SHALL BE PERFORMED BY GENERAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL ENSURE THAT ALL WORK COMPLIES WITH ALL APPLICABLE LOCAL AND STATE CODES AND NATIONAL ELECTRICAL CODE. 2.ALL SUGGESTED ELECTRICAL ELEMENTS (SUCH AS BREAKER SIZES, WIRE SIZES, CONDUITS SIZES ARE FOR ZONING PURPOSES ONLY. IT IS THE RESPONSIBILITY TO OF THE ELECTRICAL CONTRACTOR TO CONFIRM COMPLIANCE WITH LOCAL ELECTRICAL CODES AND PASS ALL APPLICABLE AND NECESSARY INSPECTIONS. IN SOME EVENTS, IT MAY BE NECESSARY TO PERFORM AN ELECTRICAL LOAD STUDY TO VERIFY THE CAPACITY OF THE EXISTING SERVICE. THIS IS NOT THE RESPONSIBILITY OF CONCORDIA. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 3.CONTRACTOR SHALL FIELD LOCATE ALL BELOW GRADE GROUND LINES AND UTILITY LINES PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR RELOCATION OF ALL UTILITIES AND GROUND LINES THAT MAY BECOME DISTURBED OR CONFLICTING IN THE COURSE OF CONSTRUCTION. ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESE CONSTRUCTION DRAWINGS SHALL BE COMMUNICATED TO ATC ENGINEERING IMMEDIATELY FOR CORRECTION OR RE-DESIGN. FAILURE TO COMMUNICATE DIRECTLY WITH ATC ENGINEERING OR ANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIOR APPROVAL FROM ATC ENGINEERING SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. Planning Administrative Approval 12/14/2021 XXSHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-101 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. DATE DRAWN:10/26/21 ATC JOB NO: HACKBERRY SPECTRA TX0152CUSTOMER ID: 13739441_G5 DA01305BCUSTOMER #: 309143 ATC SITE NAME: IRVING-HACKBERRY HACKBERRY SPECTRA TX0152 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 DETAILED SITE PLAN A PRELIM VS 10/26/21 0 FINALS TR 12/06/21 0 SITE PLAN NOTES: 1.THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. 2.ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL PROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN. BEFORE UTILIZING EXISTING CABLE SUPPORTS, COAX PORTS, INSTALLING NEW PORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS. 3.NO ELECTRICAL SCOPE IS INCLUDED IN THIS PROJECT. LEGEND AUTOMATIC TRANSFER SWITCHATS DISCONNECTD ELECTRICALE FIBERF BOLLARDB GENERATOR RECEPTACALG HAND HOLE, VAULTHH, V ICE BRIDGEIB KENTROX BOXK GENERATORGEN METERM LIGHTING CONTROLLC PULL BOXPB POWER POLEPP TELCOT TRANSFORMERTRN XCHAINLINK FENCE GROUNDING TEST WELL CELL SITE CABINETCSC PROPOSED CABLE LENGTH: 1.ESTIMATED LENGTH OF PROPOSED CABLE IS 165'±. ESTIMATED LENGTH OF CABLE WAS PROVIDED BY CUSTOMER OR CALCULATED BY ADDING THE RAD CENTER AND THE DISTANCE FROM THE SHELTER ENTRY PLATE TO THE TOWER (ALONG THE ICE BRIDGE) AND A SAFETY FACTOR MEASUREMENT OF 15% (OF THE TWO PREVIOUS VALUES), CDS DEFER TO GREATEST CABLE LENGTH. 2.ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTING CABLES AND IN ACCORDANCE WITH STRUCTURAL ANALYSIS. IF ADEQUATE SPACE EXISTS, ROUTE CABLES THROUGH ENTRY PORT HOLE, UP INSIDE OF MONOPOLE, AND THROUGH EXIT PORT HOLE. IF ROUTING OUTSIDE THE MONOPOLE, ATTACH CABLES USING STAND-OFF ADAPTERS MOUNTED TO TOWER USING STAINLESS STEEL BANDING. ADEQUATELY SECURE CABLES USING EITHER APPROPRIATELY SIZED STAINLESS STEEL SNAP-INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE MANUFACTURER. 1 DETAILED SITE PLAN GRAPHIC SCALE ( IN FEET ) 1 UNIT = 10 FEET 105010 (MODIFIED AS REQUIRED FOR UPGRADE FROM 791A_GXX TO 56791EZ_SR_U21 CONFIGURATION) 1 R-601 2 C-102 4 E-501 PROPOSED (2) HCS 2.0 TRUNK (ROUTED PER PROPOSED CABLE LENGTH NOTE 2) (REFER TO PROPOSED CABLE LENGTH NOTE ON THIS PAGE) (TO BE REMOVED) Planning Administrative Approval 12/14/2021 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-102 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. DATE DRAWN:10/26/21 ATC JOB NO: HACKBERRY SPECTRA TX0152CUSTOMER ID: 13739441_G5 DA01305BCUSTOMER #: 309143 ATC SITE NAME: IRVING-HACKBERRY HACKBERRY SPECTRA TX0152 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 A PRELIM VS 10/26/21 0 FINALS TR 12/06/21 0 DETAILED GROUND PLAN 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 1 EXISTING EQUIPMENT PLAN 2 PROPOSED EQUIPMENT PLAN GRAPHIC SCALE 63 ( IN FEET ) 1 UNIT = 3 FEET 0 3 GRAPHIC SCALE 63 ( IN FEET ) 1 UNIT = 3 FEET 0 3 PROPOSED T-MOBILE 600A HPL3 SSC CABINET PROPOSED T-MOBILE LB3 LARGE BATTERY CABINET PROPOSED T-MOBILE MODULES (2) ASIB(s), (2) ASIK(s), (3) ABIA(s), (6) ABIL(s), (3) ABIC(s), (2) AMIA(s) AND (1) CSR IXRe V2 (Gen2) PROPOSED (2) HCS 2.0 TRUNK (TO BE REMOVED) PROPOSED (2) HCS 2.0 JUNCTION BOXES (TO BE REMOVED) (TO BE REMOVED) (TO BE REMOVED) (TO BE REMOVED) (TO BE REMOVED) (TO BE REMOVED) (TO BE REMOVED) (TO BE RELOCATED) (TO BE REMOVED) (TO BE REMOVED) EQUIPMENT PLATFORM NOTE: STEEL PLATFORM ANALYSIS BY OTHERS. NO NEW EQUIPMENT SHALL BE INSTALLED ON THE PLATFORM WITHOUT THE APPROVAL OF A STRUCTURAL ENGINEER. SITE PLAN NOTES: 1.CONTRACTOR TO VERIFY THERE IS NO LIVE AAV FIBER RUNNING THROUGH EXISTING DEAD EQUIPMENT. IF SO, THIS WILL NEED TO BE RERUN THROUGH CONDUIT PRIOR TO REMOVING DEAD 2G (6201 CABS) EQUIPMENT. 2.REMOVE EXISTING 2G CABINETS, AND POWER / TELCO WHIPS ASSOCIATED WITH THE DEAD EQUIPMENT IF APPLICABLE. 3.ALL OPEN PORTS NEED TO BE SEALED / WEATHERPROOFED PROPERLY 4.ALL UNNEEDED / EXCESS EQUIPMENT AND GARBAGE TO BE REMOVED FROM EQUIPMENT AREA. DISPOSE OF MATERIALS PROPERLY OFF SITE. T-MOBILE CM APPROVAL REQUIRED BEFORE INSTALLING CABINETS Planning Administrative Approval 12/14/2021 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-201 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. DATE DRAWN:10/26/21 ATC JOB NO: HACKBERRY SPECTRA TX0152CUSTOMER ID: 13739441_G5 DA01305BCUSTOMER #: 309143 ATC SITE NAME: IRVING-HACKBERRY HACKBERRY SPECTRA TX0152 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 TOWER ELEVATION A PRELIM VS 10/26/21 0 FINALS TR 12/06/21 0 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 PROPOSED T-MOBILE ANTENNAS RAD CENTER @ 90' TOWER NOTE: 1.IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONFIRM WITH THE PROJECT MANAGER THAT THEY HAVE THE MOST RECENT VERSION OF THE STRUCTURAL ANALYSIS BEFORE COMMENCING WORK. EXISTING AND PROPOSED TOWER APPURTENANCES, MOUNTS, AND ANTENNAS ARE SHOWN BASED ON THE STRUCTURAL ANALYSIS. 2.WHERE APPLICABLE, ALL NEW ANTENNAS, EQUIPMENT, MOUNTS, CABLING, ETC. SHALL BE PAINTED/SOCKED TO MATCH EXISTING EQUIPMENT IN ACCORDANCE WITH FAA, JURISDICTION, AND/OR OTHER LOCAL REQUIREMENTS. 3.ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTING CABLES AND IN ACCORDANCE WITH STRUCTURAL ANALYSIS. IF ADEQUATE SPACE EXISTS, ROUTE CABLES THROUGH ENTRY PORT HOLE, UP INSIDE OF MONOPOLE, AND THROUGH EXIT PORT HOLE. IF ROUTING OUTSIDE THE MONOPOLE, ATTACH CABLES USING STAND-OFF ADAPTERS MOUNTED TO TOWER USING STAINLESS STEEL BANDING. ADEQUATELY SECURE CABLES USING EITHER APPROPRIATELY SIZED STAINLESS STEEL SNAP-INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE MANUFACTURER. 4.TOWER ELEVATIONS ARE MEASURED FROM TOP OF BASE PLATE TO MATCH STRUCTURAL ANALYSIS. ELEVATIONS DO NOT REFLECT TRUE ABOVE GROUND LEVEL (A.G.L.) ATC HAS NOT ANALYZED THE EXISTING ANTENNA MOUNT(S) TO DETERMINE ADEQUATE STRUCTURAL CAPACITY FOR PROPOSED CARRIER LOADING. 1 TOWER ELEVATION SCALE: N.T.S. PROPOSED T-MOBILE EQUIPMENT AND MOUNT REPLACEMENT 2 C-401 1 C-401 Planning Administrative Approval 12/14/2021 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-401 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. DATE DRAWN:10/26/21 ATC JOB NO: HACKBERRY SPECTRA TX0152CUSTOMER ID: 13739441_G5 DA01305BCUSTOMER #: 309143 ATC SITE NAME: IRVING-HACKBERRY HACKBERRY SPECTRA TX0152 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 ANTENNA INFORMATION & SCHEDULE A PRELIM VS 10/26/21 0 FINALS TR 12/06/21 0 CONTRACTOR SHALL RE-ORIENT ANTENNA MOUNT(s) AS NECESSARY TO ACHIEVE PROPOSED ANTENNA AZIMUTHS AZ.=ALPHA0°ATC HAS NOT ANALYZED THE EXISTING ANTENNA MOUNT(S) TO DETERMINE ADEQUATE STRUCTURAL CAPACITY FOR PROPOSED CARRIER LOADING. 1 EXISTING ANTENNA PLAN SCALE: N.T.S.2 FINAL ANTENNA PLAN SCALE: N.T.S. 3 EQUIPMENT SCHEDULES FINAL FIBER DISTRIBUTION / OVP BOX FINAL CABLING SUMMARY MODEL NUMBER STATUS COAX HYBRID STATUS (2) HCS 2.0 BREAKOUT PANDENT ADD -(2) HCS 2.0 HYBRID FIBER ADD ----- EXISTING FIBER DISTRIBUTION/OVP BOX EXISTING CABLING SUMMARY MODEL NUMBER STATUS COAX HYBRID STATUS RMV RMV CABLE LENGTHS FOR JUMPERS JUNCTION BOX TO RRU: 15' RRU TO ANTENNA: 10' 1.CONFIRM WITH T-MOBILE REP FOR APPLICABLE UPDATES/REVISIONS AND MOST RECENT RFDS FOR NSN CONFIGURATION (CONFIG). GC TO CAP ALL UNUSED PORTS. 2.CONFIRM SPACING OF PROPOSED EQUIP DOES NOT CAUSE TOWER CONFLICTS NOR IMPEDE TOWER CLIMBING PEGS. NOTES STATUS ABBREVIATIONS RMV: TO BE REMOVED : TO REMAIN REL: TO BE RELOCATED ADD: TO BE ADDED AZ . = BE T A 12 0 ° AZ.= GAM M A 240 °A1 A2 A3 A4 B1 B2 B3 B4C1 C2 C3 C4 A1 A2 A3 A4 B1 B2 B3 B4C1 C2 C3 C4 PROPOSED AEHC ANTENNA (1 PER SECTOR) (TYP. 3)2 C-501 PROPOSED AHFIG RRU (1 PER SECTOR) (TYP. 3) 3 C-501 1 C-501 PROPOSED FFVV-65C-R3-V1 ANTENNA (1 PER SECTOR) (TYP. 3) PROPOSED BREAKOUT PENDANT HCS 2.0 (TYP. 2) 4 C-501 PROPOSED AHLOA RRU (1 PER SECTOR) (TYP. 3) 3 C-501 (TO BE REMOVED) (TO BE REMOVED) (TO BE REMOVED) (TO BE REMOVED) (TO BE REMOVED) (TO BE REMOVED) (TO BE REMOVED) FINAL ANTENNA SCHEDULE LOCATION ANTENNA SUMMARY NON ANTENNA SUMMARY SECTOR RAD AZ POS ANTENNA BAND MECH/ELEC D-TILT STATUS ADDITIONAL TOWER MOUNTED EQUIPMENT STATUS ALPHA 90'0° A1 AEHC L2500,N2500 0/-ADD -- A2 ------ A3 ------ A4 FFVV-65C-R3-V1 L700,L600,N600, N2100,N1900,L2100 L1900,G1900,U2100 0/-ADD AHLOA RRU AHFIG RRU ADD ADD BETA 90'120° B1 AEHC L2500,N2500 0/-ADD -- B2 ------ B3 ------ B4 FFVV-65C-R3-V1 L700,L600,N600, N2100,N1900,L2100 L1900,G1900,U2100 0/-ADD AHLOA RRU AHFIG RRU ADD ADD GAMMA 90'240° C1 AEHC L2500,N2500 0/-ADD -- C2 ------ C3 ------ C4 FFVV-65C-R3-V1 L700,L600,N600, N2100,N1900,L2100 L1900,G1900,U2100 0/-ADD AHLOA RRU AHFIG RRU ADD ADD EXISTING ANTENNA SCHEDULE LOCATION ANTENNA SUMMARY NON ANTENNA SUMMARY SECTOR RAD AZ POS ANTENNA BAND MECH/ELEC D-TILT STATUS ADDITIONAL TOWER MOUNTED EQUIPMENT STATUS RMV RMV RMV RMV RMV RMV RMV RMV RMV RMV RMV RMV RMV RMV RMV RMV RMV RMV RMV RMV RMV PROPOSED PV-LPPGS-12M-HR2-AP1 PLATFORM4 C-501 (TO BE REMOVED AND REPLACED) Planning Administrative Approval 12/14/2021 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-501 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. DATE DRAWN:10/26/21 ATC JOB NO: HACKBERRY SPECTRA TX0152CUSTOMER ID: 13739441_G5 DA01305BCUSTOMER #: 309143 ATC SITE NAME: IRVING-HACKBERRY HACKBERRY SPECTRA TX0152 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 CONSTRUCTION DETAILS A PRELIM VS 10/26/21 0 FINALS TR 12/06/21 0 3 PROPOSED RRU MOUNTING DETAIL - TYPICAL SCALE: N.T.S. PROPOSED ANTENNA 1 PROPOSED ANTENNA MOUNTING DETAIL - TYPICAL SCALE: N.T.S. PROPOSED ANTENNA 2 PROPOSED 5G ANTENNA MOUNTING DETAIL - TYPICAL SCALE: N.T.S. 4 PROPOSED PLATFORM DETAIL - TYPICAL SCALE: N.T.S. PROPOSED T-MOBILE MONOPOLE PLATFORM MOUNT (PERFECT VISION P/N-LPPGS-12M-HR2-AP1) PROPOSED 2" STD (2.38" O.D.) x 96" LONG PIPE MAST (TYP. OF 4 PER SECTOR, TOTAL OF 12) (INCLUDED WITH KIT) PROPOSED T-MOBILE MONOPOLE PLATFORM MOUNT (PERFECT VISION P/N-LPPGS-12M-HR2-AP1) PROPOSED 2" STD (2.38" O.D.) x 96" LONG PIPE MAST (TYP. OF 4 PER SECTOR, TOTAL OF 12) (INCLUDED WITH KIT) PROPOSED T-MOBILE MONOPOLE PLATFORM MOUNT (PERFECT VISION P/N-LPPGS-12M-HR2-AP1) PROPOSED 2" STD (2.38" O.D.) x 96" LONG PIPE MAST (TYP. OF 4 PER SECTOR, TOTAL OF 12) (INCLUDED WITH KIT) PROPOSED T-MOBILE MONOPOLE PLATFORM MOUNT (PERFECT VISION P/N-LPPGS-12M-HR2-AP1) PROPOSED 2" STD (2.38" O.D.) x 96" LONG PIPE MAST (TYP. OF 4 PER SECTOR, TOTAL OF 12) (INCLUDED WITH KIT) PROPOSED RRU (TYP.) Planning Administrative Approval 12/14/2021 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.E-501 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. DATE DRAWN:10/26/21 ATC JOB NO: HACKBERRY SPECTRA TX0152CUSTOMER ID: 13739441_G5 DA01305BCUSTOMER #: 309143 ATC SITE NAME: IRVING-HACKBERRY HACKBERRY SPECTRA TX0152 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 GROUNDING DETAILS A PRELIM VS 10/26/21 0 FINALS TR 12/06/21 0 NOTES: 1.THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS. SLIGHT ADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THE CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THE CONSTRUCTION MANAGER OF ANY CONFLICTS. 2.SITE GROUNDING SHALL COMPLY WITH T-MOBILE GROUNDING STANDARDS, LATEST EDITION, AND COMPLY WITH T-MOBILE GROUNDING CHECKLIST, LATEST VERSION. WHEN NATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN. PROPOSED CONNECTOR AND WEATHERPROOFING KIT 1 TYPICAL ANTENNA GROUNDING DIAGRAM SCALE: N.T.S. PROPOSED ANTENNA PROPOSED JUMPER PROPOSED WEATHERPROOFING KIT 2 E-501 3 E-501 GROUND BAR MOUNTED NEAR/BELOW ANTENNA (TO BE INSTALLED IF REQUIRED) #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION ANTENNA CABLE TO CABINET (TYP.) PROPOSED CABLE GROUND KIT PROPOSED #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION TO PROPOSED RRU GROUND LUG (TYP.) PROPOSED #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION TO PROPOSED OVP BOX DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT (ANDREW PART NUMBER 221213) AND INSTALL/TAPE PER MANUFACTURER'S SPECIFICATIONS. 2 CABLE GROUND KIT CONNECTION DETAIL SCALE: N.T.S. TO ANTENNA TO EQUIPMENT TO GROUND BAR ANTENNA CABLE 2 1/2"Ø MAX GROUNDING KIT PER CABLE MANUFACTURER'S RECOMMENDATIONS (ANDREW OR APPROVED EQUAL) #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) GROUND KIT NOTES: 1. 2. 1/4" X 4" X 6" GROUND BAR (ERICO P/N: EGBA14406CC OR EQUAL) 3 TOWER GROUND BAR DETAIL SCALE: N.T.S. GROUND BAR NOTES: 1.GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS, WASHERS, ETC. EXCEPT THE STRUCTURAL MOUNTING MEMBER(S). 2.GROUND BAR TO BE BONDED DIRECTLY TO TOWER. 3/8" SS LOCK WASHER (EACH SIDE) TWO-HOLE LUG, TO BE USED WITH #2 AWG BCW (LOWER TOWER GROUND BAR ONLY) 3/8" X 1-1/2" SS BOLT (EACH SIDE) OCPD SIZE WIRE SIZE GROUND SIZE CONDUIT SIZE 80A/2P 2#3 AWG #8 AWG 1-1/4" 100/2P 2#2 AWG #8 AWG 1-1/4" 125A/2P 2#1 AWG #8 AWG 1-1/2" 150A/2P 2#1/0 AWG #8 AWG 1-1/2" ELECTRICAL NOTES: 1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITY COMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS, BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENT REQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND NATIONAL CODES, ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. 2.ATC HAS NOT VERIFIED ANY EXISTING T-MOBILE GROUND EQUIPMENT OR ELECTRICAL LOADING. PROPOSED WORK BASED ON INSTALLATION CONFIGURATION PROVIDED BY T-MOBILE. CONTRACTOR TO VERIFY EXISTING T-MOBILE PANEL HAS SUFFICIENT SPACE FOR PROPOSED BREAKER. PROPOSED CABLE AND CONDUIT SHALL BE MINIMUM SIZE PER BELOW IN CHART. 3.FOR SPECIFIC CABINET / ANCILLARY EQUIPMENT WIRING REQUIREMENTS, THE T-MOBILE CONTRACTOR SHOULD REFERENCE DESIGN DOCUMENTS PROVIDED BY T-MOBILE FOR THIS CURRENT PROJECT CONFIGURATION, IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS & NEC STANDARDS & PRACTICES. 4 CABINET GROUNDING DETAIL SCALE: N.T.S. PROPOSED CABINET #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTOR Planning Administrative Approval 12/14/2021 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-601 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. DATE DRAWN:10/26/21 ATC JOB NO: HACKBERRY SPECTRA TX0152CUSTOMER ID: 13739441_G5 DA01305BCUSTOMER #: 309143 ATC SITE NAME: IRVING-HACKBERRY HACKBERRY SPECTRA TX0152 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 0 VS 10/26/21 0 SUPPLEMENTAL NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. Planning Administrative Approval 12/14/2021 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-602 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. DATE DRAWN:10/26/21 ATC JOB NO: HACKBERRY SPECTRA TX0152CUSTOMER ID: 13739441_G5 DA01305BCUSTOMER #: 309143 ATC SITE NAME: IRVING-HACKBERRY HACKBERRY SPECTRA TX0152 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 0 VS 10/26/21 0 SUPPLEMENTAL NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. Planning Administrative Approval 12/14/2021 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-603 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. DATE DRAWN:10/26/21 ATC JOB NO: HACKBERRY SPECTRA TX0152CUSTOMER ID: 13739441_G5 DA01305BCUSTOMER #: 309143 ATC SITE NAME: IRVING-HACKBERRY HACKBERRY SPECTRA TX0152 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 0 VS 10/26/21 0 SUPPLEMENTAL NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. Planning Administrative Approval 12/14/2021 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-604 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. DATE DRAWN:10/26/21 ATC JOB NO: HACKBERRY SPECTRA TX0152CUSTOMER ID: 13739441_G5 DA01305BCUSTOMER #: 309143 ATC SITE NAME: IRVING-HACKBERRY HACKBERRY SPECTRA TX0152 1850 E. BELTLINE ROAD COPPELL, TX 75019-9607 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: 45 BEECHWOOD DRIVE TEL: (978) 557-5553 N. ANDOVER, MA 01845 FAX: (978) 336-5586 0 VS 10/26/21 0 SUPPLEMENTAL NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. Planning Administrative Approval 12/14/2021