Landscape Plan & Tree PreservationGATEWAY BOULEVARDINTERSTATE HIGHWAY NO. 635L.B.J. FRWYSOUTH ROYAL LANE
GATEWAY BOULEVARDSOUTH ROYAL LANE WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSWSSSSSSSSSSSSSSSSSSSSSSWGASGASGASBUILDING 1120,120 SFFFE: 542.50(42' HEIGHT)BUILDING 2161,720 SFFFE: 540.50(42' HEIGHT)NO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGUGEUGEUGEUGEUGEUGETREE 3080TREE 2878TREE 2879TREE 2880TREE 2881TREE 2877TREE 2876TREE 2875TREE 2873TREE 2872TREE 2871TREE 3093TREE 4396TREE 2902TREE 2903TREE 2904TREE 3305TREE 2466TREE 2474TREE 3073TREE 2253TREE 2267TREE 4011TREE 4006TREE 4005TREE 3987TREE 3984TREE 2512TREE 2515TREE 2516TREE 2544TREE 2545TREE 2548TREE 2575TREE 2576TREE 2595TREE 2612TREE 2613TREE 2627TREE 3079TREE 3078TREE 3077TREE 3076TREE 3075TREE 3072TREE 3074TPFTPF TPF TPFTPFTPFTPFTPFTPF TPFTPF TPFTPFTPFTPFTPF TPFTPFTPFTPFTPF TPFTPFTPFTPFTPFTPFTPFTPF TPFTPFTPFTPFTPFTPFTPF TPFTPFTPFTPFTPFTPFTPF TPFTPFTPFTPFTPFTPFTPF TPFTPFTPFTPFREVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2022CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SEEFRIED COPPELL!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesBMLOCT. 2022CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:10821-00\\browngay.net\panzura\Regions\TXN\Projects\Seefried_Industrial_Props\10821-00-16_Acres_Coppell_TX\LP-NTX\03-CAD\03-SHEETS\10821-TP1_TREE PRESERVATION PLAN.dwg Oct 11, 2022-3:56pm blevyBGE, INC.
SEEFRIED COPPELL
WBMBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.3030 LBJ Freeway, Suite 1650SEEFRIED INDUSTRIALDallas, TX 75234OWNER/DEVELOPERContact:Jonathan StitesTel: 214-393-60665310 Harvest Hill Rd, Suite 180PROSS DESIGN GROUP, INC.Dallas, Texas 75230ARCHITECTContact:Mark ProssTel: 972-759-1400TP1.1OVERALL TREE PRESERVATION PLAN
TP1.0TP1.2
SOUTH ROYAL LANE WWWWWWWWWWWWWWWWWWWWWSSSSSSWWWGASGASGASGASBUILDING 1120,120 SFFFE: 542.50(42' HEIGHT)BUILDING 2161,720 SFFFE: 540.50(42' HEIGHT)UGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGETREE 3080TREE 2878TREE 2879TREE 2880TREE 2881TREE 2877TREE 2876TREE 2875TREE 2873TREE 2872TREE 2871TREE 3093TREE 4396TREE 2902TREE 2903TREE 2904TREE 3305TREE 2466TREE 2474TREE 3073TREE 2253TREE 2267TREE 4011TREE 4006TREE 3079TREE 3078TREE 3077TREE 3076TREE 3075TREE 3072TREE 3074TPFTPFTPF TPF TPFTPFTPFTPFTPFTPF TPFTPFTPFTPF TPFTPFTPFTPF TPFTPFTPFTPFTPFTPF TPFTPFTPFTPFTPFTPFTPFTPFTPFTPFTPF TPFTPFTPFTPFTPFTPFTPFTPFTPFTPF TPF TPFTPFTPFTPFTPFTPFTPFTPFTPFTPF TPFTPFTPFTPFTPFTPFREVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2022CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SEEFRIED COPPELL!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesBMLOCT. 2022CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:10821-00\\browngay.net\panzura\Regions\TXN\Projects\Seefried_Industrial_Props\10821-00-16_Acres_Coppell_TX\LP-NTX\03-CAD\03-SHEETS\10821-TP1_TREE PRESERVATION PLAN.dwg Oct 11, 2022-3:56pm blevyBGE, INC.
SEEFRIED COPPELL
WBMBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.3030 LBJ Freeway, Suite 1650SEEFRIED INDUSTRIALDallas, TX 75234OWNER/DEVELOPERContact:Jonathan StitesTel: 214-393-60665310 Harvest Hill Rd, Suite 180PROSS DESIGN GROUP, INC.Dallas, Texas 75230ARCHITECTContact:Mark ProssTel: 972-759-1400TREE PRESERVATION PLAN
TP1.1LEGENDEXISTING TREE TO BE PRESERVEDEXISTING TREE TO BE REMOVEDTREE PROTECTION FENCETREE ID LABELTPFROYAL LN
GATEWAY BLVDLBJ FWY IH 635ST. LOUIS & SOUTHERN RAILROADEXCHANGE CIRCLEVICINITY MAP(NOT TO SCALE)PROPERTY LINE - LIMIT OF WORK
SEE SHEET TP1.2 (MATCHLINE)PROPERTY LINE - LIMIT OF WORK PROPERTY LINE - LIMIT OF WORKNOTE: EXISTING TREE DATA AND MITIGATION/CREDIT CALCULATIONSFOUND ON SHEET TP1.3
GATEWAY BOULEVARDINTERSTATE HIGHWAY NO. 635L.B.J. FRWYGATEWAY BOULEVARDSOUTH ROYAL LANE WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGTREE 4006TREE 4005TREE 3987TREE 3984TREE 2512TREE 2515TREE 2516TREE 2544TREE 2545TREE 2548TREE 2575TREE 2576TREE 2595TREE 2612TREE 2613TREE 2627TPFTPF TPF TPF TPFTPFTPFTPFTPFTPFTPFTPFTPF TPFTPF TPF TPFTPFTPFTPFTPFTPFTPF TPFTPFTPFTPFTPFTPFTPF
TPF TPFTPFTPFTPFTPF TPFTPFTPFTPFTPFTPF
TPFTPFTPFTPF
TPFTPFTPFTPF
TPFTPFTPFTPF
TPFREVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2022CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SEEFRIED COPPELL!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesBMLOCT. 2022CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:10821-00\\browngay.net\panzura\Regions\TXN\Projects\Seefried_Industrial_Props\10821-00-16_Acres_Coppell_TX\LP-NTX\03-CAD\03-SHEETS\10821-TP1_TREE PRESERVATION PLAN.dwg Oct 11, 2022-3:56pm blevyBGE, INC.
SEEFRIED COPPELL
WBMBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.3030 LBJ Freeway, Suite 1650SEEFRIED INDUSTRIALDallas, TX 75234OWNER/DEVELOPERContact:Jonathan StitesTel: 214-393-60665310 Harvest Hill Rd, Suite 180PROSS DESIGN GROUP, INC.Dallas, Texas 75230ARCHITECTContact:Mark ProssTel: 972-759-1400TREE PRESERVATION PLAN
TP1.2ROYAL LN
GATEWAY BLVDLBJ FWY IH 635ST. LOUIS & SOUTHERN RAILROADEXCHANGE CIRCLEVICINITY MAP(NOT TO SCALE)PROPERTY LINE - LIMIT OF WORK
SEE SHEET TP1.1 (MATCHLINE)PROPERTY LINE - LIMIT OF WORKPROPERTY LINE - LIMIT OF WORKLEGENDEXISTING TREE TO BE PRESERVEDEXISTING TREE TO BE REMOVEDTREE PROTECTION FENCETREE ID LABELTPFNOTE: EXISTING TREE DATA AND MITIGATION/CREDIT CALCULATIONSFOUND ON SHEET TP1.3
REVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2022CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SEEFRIED COPPELL!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesBMLOCT. 2022CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:10821-00\\browngay.net\panzura\Regions\TXN\Projects\Seefried_Industrial_Props\10821-00-16_Acres_Coppell_TX\LP-NTX\03-CAD\03-SHEETS\10821-TP1_TREE PRESERVATION PLAN.dwg Oct 11, 2022-3:56pm blevyBGE, INC.
SEEFRIED COPPELL
WBMBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.3030 LBJ Freeway, Suite 1650SEEFRIED INDUSTRIALDallas, TX 75234OWNER/DEVELOPERContact:Jonathan StitesTel: 214-393-60665310 Harvest Hill Rd, Suite 180PROSS DESIGN GROUP, INC.Dallas, Texas 75230ARCHITECTContact:Mark ProssTel: 972-759-1400TREE PRESERVATION DATA & DETAILS
TP 1.3
GATEWAY BOULEVARDINTERSTATE HIGHWAY NO. 635L.B.J. FRWYSOUTH ROYAL LANE WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSWSSSSSSSSSSSSSSSSSSSSSSWGASGASGASBUILDING 1120,120 SFFFE: 542.50(42' HEIGHT)BUILDING 2161,720 SFFFE: 540.50(42' HEIGHT)NO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGUGEUGEUGEUGEUGEUGEREVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2022CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SEEFRIED COPPELL!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesBMLOCT. 2022CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:10821-00\\browngay.net\panzura\Regions\TXN\Projects\Seefried_Industrial_Props\10821-00-16_Acres_Coppell_TX\LP-NTX\03-CAD\03-SHEETS\10821-L2_PLNT PLAN.dwg Oct 11, 2022-3:56pm blevyBGE, INC.
SEEFRIED COPPELL
WBMBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.3030 LBJ Freeway, Suite 1650SEEFRIED INDUSTRIALDallas, TX 75234OWNER/DEVELOPERContact:Jonathan StitesTel: 214-393-60665310 Harvest Hill Rd, Suite 180PROSS DESIGN GROUP, INC.Dallas, Texas 75230ARCHITECTContact:Mark ProssTel: 972-759-1400L2.1L2.2L2.3L2.4OVERALL LANDSCAPE PLAN
L2.0
GATEWAY BOULEVARDINTERSTATE HIGHWAY NO. 635L.B.J. FRWYSOUTH ROYAL LANE WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSWWSSSSSSSSSSSSSSSSSSSSSSSSSSSSWGASGASGASBUILDING 1120,120 SFFFE: 542.50(42' HEIGHT)BUILDING 2161,720 SFFFE: 540.50(42' HEIGHT)NO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGNO PARKINGUGEUGEUGEUGEUGEUGEUGEUGEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREENORTH PERIMETER TREENORTH PERIMETER TREENORTH PERIMETER TREEEAST PERIMETER TREESOUTH PERIMETER TREESOUTH PERIMETER TREESOUTH PERIMETER TREESOUTH PERIMETER TREESOUTH PERIMETER TREEWEST PERIMETER TREEWEST PERIMETER TREEWEST PERIMETER TREE15' PERIMETERLANDSCAPE BUFFER10' PERIMETERLANDSCAPE BUFFERNORTH PERIMETER TREE10' PERIMETERLANDSCAPE BUFFER15' PERIMETERLANDSCAPE BUFFER15' PERIMETERLANDSCAPE BUFFER15' PERIMETERLANDSCAPE BUFFER15' PERIMETERLANDSCAPE BUFFER10' PERIMETERLANDSCAPE BUFFER10' PERIMETERLANDSCAPE BUFFER10' PERIMETERLANDSCAPE BUFFER10' PERIMETERLANDSCAPE BUFFERINTERIOR TREEOPEN SPACE TREEOPEN SPACE TREEOPEN SPACE TREEOPEN SPACE TREEOPEN SPACE TREEEAST PERIMETER TREEEAST PERIMETER TREEEAST PERIMETER TREEEAST PERIMETER TREEEAST PERIMETER TREEEAST PERIMETER TREEINTERIOR TREEREVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2022CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SEEFRIED COPPELL!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesBMLOCT. 2022CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:10821-00\\browngay.net\panzura\Regions\TXN\Projects\Seefried_Industrial_Props\10821-00-16_Acres_Coppell_TX\LP-NTX\03-CAD\03-SHEETS\10821-L2_PLNT PLAN.dwg Oct 11, 2022-3:56pm blevyBGE, INC.
SEEFRIED COPPELL
WBMBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.3030 LBJ Freeway, Suite 1650SEEFRIED INDUSTRIALDallas, TX 75234OWNER/DEVELOPERContact:Jonathan StitesTel: 214-393-60665310 Harvest Hill Rd, Suite 180PROSS DESIGN GROUP, INC.Dallas, Texas 75230ARCHITECTContact:Mark ProssTel: 972-759-1400CODE LANDSCAPE AREAS EXHIBIT
L2.1LANDSCAPE AREA KEYINTERIOR LANDSCAPE AREA19,153 SF REQUIRED 22,403 SF PROVIDEDNON-VEHICULAR/ FRONT YARD LANDSCAPE AREA7,391 SF REQUIRED 32,865 SF PROVIDEDIN FRONT YARDS IN FRONT YARDSPERIMETER BUFFER LANDSCAPE AREA74 TOTAL TREES REQUIRED ACROSS ALL PERIMETERS76 TOTAL EXISTING AND PROPOSED TREES PROVIDEDNOTE: ALL TREES ARE CALLED OUT WITH A LABEL TO INDICATE WHICH LANDSCAPEAREA CREDIT THEY ARE MEETING
SOUTH ROYAL LANE WWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSWWWWWGASGASGASGASGASGASBUILDING 1120,120 SFFFE: 542.50(42' HEIGHT)UGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREENORTH PERIMETER TREENORTH PERIMETER TREEWEST PERIMETER TREEWEST PERIMETER TREE15' PERIMETERLANDSCAPE BUFFER10' PERIMETERLANDSCAPE BUFFER15' PERIMETERLANDSCAPE BUFFER2' MULCH BEDSTEEL EDGING2' MULCH BEDSTEEL EDGINGQV1QV3UC3QV1QV2QM2QV3QM2QV1QM1LM88TA129EF169TA119TA105EF219EF1303LM88LM88TA127TA120TA129LM137TA120EF1303LM88LM88TA376AG62AG47LI5ENTRY SIGNREVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2022CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SEEFRIED COPPELL!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesBMLOCT. 2022CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:10821-00\\browngay.net\panzura\Regions\TXN\Projects\Seefried_Industrial_Props\10821-00-16_Acres_Coppell_TX\LP-NTX\03-CAD\03-SHEETS\10821-L2_PLNT PLAN.dwg Oct 11, 2022-3:57pm blevyBGE, INC.
SEEFRIED COPPELL
WBMBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.3030 LBJ Freeway, Suite 1650SEEFRIED INDUSTRIALDallas, TX 75234OWNER/DEVELOPERContact:Jonathan StitesTel: 214-393-60665310 Harvest Hill Rd, Suite 180PROSS DESIGN GROUP, INC.Dallas, Texas 75230ARCHITECTContact:Mark ProssTel: 972-759-1400LANDSCAPE PLAN
L2.2PROPERTY LINE - LIMIT OF WORK
SEE SHEET L2.2 (MATCHLINE)SEE SHEET L2.3 (MATCHLINE)PROPERTY LINE - LIMIT OF WORKNOTE: ABOVE PLANT NAMES AND QUANTITIES ARE PROVIDED FOR CONVENIENCEIF THERE IS A DISCREPANCY, REFER TO THE PLAN FOR ACCURATE QUANTITIES.NOTE: REFER TO PLANTING NOTES FOR APPROVED INSTALLATION PRACTICES TOMEET THE DESIGN INTENT OF THE PLAN.NOTE: PRESERVED TREE DATA CAN BE FOUND ON PAGE TP1.3COPPELL LANDSCAPE REQUIREMENTS Required ProvidedINTERIOR LANDSCAPING [SEC. 12-34-8 (B)]: - 10% OF GROSS NONEXEMPT PARKING AND LOADING 19,153 SF 22,403 SF AREA SHALL BE LANDSCAPED 191,522SF X 10% = 19,153 SF - (1) 3 IN CAL. SHADE TREE FOR EVERY 400 SF 48 TREES 49 TREES OF REQ. INTERIOR LANDSCAPE 19,153 / 400 = 48 TREES - LANDSCAPE ISLANDS MUST BE LANDSCAPED AND YES YES CONTAIN AT LEAST (1) 3 IN CAL. SHADE TREEPERIMETER LANDSCAPING [SEC. 12-34-8 (C)]: - ALL PARKING AND VEHICULAR USE AREAS, INCLUDINGYES YES DRIVEWAYS, SHALL BE SCREENED FROM ABUTTING PROPERTIES/ PUBLIC R.O.W.S WITH A 30 IN HEDGE - PERIMETERS /R.O.W.S SHALL CONTAIN 1 TREE PER 50 LF OF PERIMETER LANDSCAPE AREA-NORTH PROPERTY LINE: (10' BUFFER/ 8,162 SF)17 TREES 13 EXISTING841/50 = 17 TREES 6 PROPOSED*-EAST PROPERTY LINE: (10' BUFFER/ 10,470 SF)22 TREES 22 PROPOSED*1,069/50 = 22 TREES-SOUTH PROPERTY LINE: (15' BUFFER/ 12,831 SF)18 TREES 9 EXISTING870/50 = 18 TREES 9 PROPOSED-WEST PROPERTY LINE: (15' BUFFER/ 8,703 SF)17 TREES 7 EXISTING841/50 = 17 TREES 10 PROPOSEDNON-VEHICULAR LANDSCAPING [SEC. 12-34-9 (A)]: - 15% OF NON-VEHICULAR SPACE THAT IS NOT COVERED 7,391 SF IN 32,865 SF IN BY BUILDINGS SHALL BE DEVOTED TO FEATUREFRONT YARD FRONT YARD LANDSCAPING WITH 50% LOCATED IN FRONT YARD(S) 49,273 SF (OF NON-VEHICULAR OS) X .15 = 7,391 SF -TREES SHALL BE PLANTED IN NON-VEHICULAR OPEN SPACE20 TREES 20 PROPOSED AT A RATE OF 1 TREE/ 2,500 SF 49,273 SF/ 2,500 = 20 TREESTOTAL LANDSCAPE AREA REQUIREMENTS: - TOTAL OF ALL LANDSCAPE AREAS ABOVE: 59,319 SF 117,231 SF - TOTAL OF ALL PROPOSED TREES ABOVE:142 TREES 113 PROPOSED* 29 EXISTING*NOTE: SOME CANOPY TREE REQUIREMENTS ARE MET WITH ORNAMENTAL TREES AT A 3:1 RATIODUE TO UTILITY AND AREA CONFLICTS.PLANT SCHEDULETREES CODE QTY COMMON NAMESIZE QM 24 Chinkapin Oak 3" CAL. UC 29 Cedar Elm 3" CAL. QV 35 Live Oak 3" CAL.SHRUBS CODE QTY COMMON NAME AG 704 Glossy Abelia 5 GAL.GROUND COVER CODE QTY COMMON NAME TA 4,274 Asian Jasmine 1 GAL. EF 10,597 Wintercreeper 1 GAL.MISC. CODE QTY COMMON NAME SOD TBD Bermuda Grass STEEL TBD EDGE MULCH TBD Shredded hardwood mulch. LM 2,672 Liriope 1 GAL. LI 37 Crape Myrtle 2" CAL. VA 44 Chaste Tree 2" CAL.
BUILDING 2161,720 SFFFE: 540.50(42' HEIGHT)UGEUGEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREENORTH PERIMETER TREEEAST PERIMETER TREE10' PERIMETERLANDSCAPE BUFFERNORTH PERIMETER TREE10' PERIMETERLANDSCAPE BUFFER10' PERIMETERLANDSCAPE BUFFER2' MULCH BEDSTEEL EDGING2' MULCH BEDSTEEL EDGINGOPEN SPACE TREEOPEN SPACE TREEEAST PERIMETER TREEEAST PERIMETER TREEQM2QV3QM3QV2LM88EF500EF500EF500EF500LM88LM88LM88LM154TA125TA133TA125LM88LM88LM88EF463EF470EF677TA147TA134AG163LI5VA5UC5LI10VA11VA10LI2REVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2022CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SEEFRIED COPPELL!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesBMLOCT. 2022CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:10821-00\\browngay.net\panzura\Regions\TXN\Projects\Seefried_Industrial_Props\10821-00-16_Acres_Coppell_TX\LP-NTX\03-CAD\03-SHEETS\10821-L2_PLNT PLAN.dwg Oct 11, 2022-3:57pm blevyBGE, INC.
SEEFRIED COPPELL
WBMBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.3030 LBJ Freeway, Suite 1650SEEFRIED INDUSTRIALDallas, TX 75234OWNER/DEVELOPERContact:Jonathan StitesTel: 214-393-60665310 Harvest Hill Rd, Suite 180PROSS DESIGN GROUP, INC.Dallas, Texas 75230ARCHITECTContact:Mark ProssTel: 972-759-1400LANDSCAPE PLAN
L2.3PROPERTY LINE - LIMIT OF WORK
SEE SHEET L2.1 (MATCHLINE)SEE SHEET L2.4 (MATCHLINE)PROPERTY LINE -LIMIT OF WORKNOTE: ABOVE PLANT NAMES AND QUANTITIES ARE PROVIDED FOR CONVENIENCEIF THERE IS A DISCREPANCY, REFER TO THE PLAN FOR ACCURATE QUANTITIES.NOTE: REFER TO PLANTING NOTES FOR APPROVED INSTALLATION PRACTICES TOMEET THE DESIGN INTENT OF THE PLAN.NOTE: PRESERVED TREE DATA CAN BE FOUND ON PAGE TP1.3COPPELL LANDSCAPE REQUIREMENTS Required ProvidedINTERIOR LANDSCAPING [SEC. 12-34-8 (B)]: - 10% OF GROSS NONEXEMPT PARKING AND LOADING 19,153 SF 22,403 SF AREA SHALL BE LANDSCAPED 191,522SF X 10% = 19,153 SF - (1) 3 IN CAL. SHADE TREE FOR EVERY 400 SF 48 TREES 49 TREES OF REQ. INTERIOR LANDSCAPE 19,153 / 400 = 48 TREES - LANDSCAPE ISLANDS MUST BE LANDSCAPED AND YES YES CONTAIN AT LEAST (1) 3 IN CAL. SHADE TREEPERIMETER LANDSCAPING [SEC. 12-34-8 (C)]: - ALL PARKING AND VEHICULAR USE AREAS, INCLUDINGYES YES DRIVEWAYS, SHALL BE SCREENED FROM ABUTTING PROPERTIES/ PUBLIC R.O.W.S WITH A 30 IN HEDGE - PERIMETERS /R.O.W.S SHALL CONTAIN 1 TREE PER 50 LF OF PERIMETER LANDSCAPE AREA-NORTH PROPERTY LINE: (10' BUFFER/ 8,162 SF)17 TREES 13 EXISTING841/50 = 17 TREES 6 PROPOSED*-EAST PROPERTY LINE: (10' BUFFER/ 10,470 SF)22 TREES 22 PROPOSED*1,069/50 = 22 TREES-SOUTH PROPERTY LINE: (15' BUFFER/ 12,831 SF)18 TREES 9 EXISTING870/50 = 18 TREES 9 PROPOSED-WEST PROPERTY LINE: (15' BUFFER/ 8,703 SF)17 TREES 7 EXISTING841/50 = 17 TREES 10 PROPOSEDNON-VEHICULAR LANDSCAPING [SEC. 12-34-9 (A)]: - 15% OF NON-VEHICULAR SPACE THAT IS NOT COVERED 7,391 SF IN 32,865 SF IN BY BUILDINGS SHALL BE DEVOTED TO FEATUREFRONT YARD FRONT YARD LANDSCAPING WITH 50% LOCATED IN FRONT YARD(S) 49,273 SF (OF NON-VEHICULAR OS) X .15 = 7,391 SF -TREES SHALL BE PLANTED IN NON-VEHICULAR OPEN SPACE20 TREES 20 PROPOSED AT A RATE OF 1 TREE/ 2,500 SF 49,273 SF/ 2,500 = 20 TREESTOTAL LANDSCAPE AREA REQUIREMENTS: - TOTAL OF ALL LANDSCAPE AREAS ABOVE: 59,319 SF 117,231 SF - TOTAL OF ALL PROPOSED TREES ABOVE:142 TREES 113 PROPOSED* 29 EXISTING*NOTE: SOME CANOPY TREE REQUIREMENTS ARE MET WITH ORNAMENTAL TREES AT A 3:1 RATIODUE TO UTILITY AND AREA CONFLICTS.PLANT SCHEDULETREES CODE QTY COMMON NAMESIZE QM 24 Chinkapin Oak 3" CAL. UC 29 Cedar Elm 3" CAL. QV 35 Live Oak 3" CAL.SHRUBS CODE QTY COMMON NAME AG 704 Glossy Abelia 5 GAL.GROUND COVER CODE QTY COMMON NAME TA 4,274 Asian Jasmine 1 GAL. EF 10,597 Wintercreeper 1 GAL.MISC. CODE QTY COMMON NAME SOD TBD Bermuda Grass STEEL TBD EDGE MULCH TBD Shredded hardwood mulch. LM 2,672 Liriope 1 GAL. LI 37 Crape Myrtle 2" CAL. VA 44 Chaste Tree 2" CAL.
GATEWAY BOULEVARDINTERSTATE HIGHWAY NO. 635WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSNO PARKINGNO PARKINGNO PARKINGNO PARKINGINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREESOUTH PERIMETER TREESOUTH PERIMETER TREEWEST PERIMETER TREE15' PERIMETERLANDSCAPE BUFFER15' PERIMETERLANDSCAPE BUFFER2' MULCH BEDSTEEL EDGING2' MULCH BEDSTEEL EDGINGINTERIOR TREEOPEN SPACE TREEQM2UC3QV3QM2QV4QM1QV5UC1LM88LM85TA123TA135TA130LM88TA280EF312LM155LM277TA725TA131EF1269AG54AG95AG21AG12ENTRY SIGNREVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2022CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SEEFRIED COPPELL!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesBMLOCT. 2022CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:10821-00\\browngay.net\panzura\Regions\TXN\Projects\Seefried_Industrial_Props\10821-00-16_Acres_Coppell_TX\LP-NTX\03-CAD\03-SHEETS\10821-L2_PLNT PLAN.dwg Oct 11, 2022-3:57pm blevyBGE, INC.
SEEFRIED COPPELL
WBMBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.3030 LBJ Freeway, Suite 1650SEEFRIED INDUSTRIALDallas, TX 75234OWNER/DEVELOPERContact:Jonathan StitesTel: 214-393-60665310 Harvest Hill Rd, Suite 180PROSS DESIGN GROUP, INC.Dallas, Texas 75230ARCHITECTContact:Mark ProssTel: 972-759-1400LANDSCAPE PLAN
L2.4PROPERTY LINE- LIMIT OF WORK
SEE SHEET L2.4 (MATCHLINE)SEE SHEET L2.1 (MATCHLINE)PROPERTY LINE -LIMIT OF WORKNOTE: ABOVE PLANT NAMES AND QUANTITIES ARE PROVIDED FOR CONVENIENCEIF THERE IS A DISCREPANCY, REFER TO THE PLAN FOR ACCURATE QUANTITIES.NOTE: REFER TO PLANTING NOTES FOR APPROVED INSTALLATION PRACTICES TOMEET THE DESIGN INTENT OF THE PLAN.NOTE: PRESERVED TREE DATA CAN BE FOUND ON PAGE TP1.3COPPELL LANDSCAPE REQUIREMENTS Required ProvidedINTERIOR LANDSCAPING [SEC. 12-34-8 (B)]: - 10% OF GROSS NONEXEMPT PARKING AND LOADING 19,153 SF 22,403 SF AREA SHALL BE LANDSCAPED 191,522SF X 10% = 19,153 SF - (1) 3 IN CAL. SHADE TREE FOR EVERY 400 SF 48 TREES 49 TREES OF REQ. INTERIOR LANDSCAPE 19,153 / 400 = 48 TREES - LANDSCAPE ISLANDS MUST BE LANDSCAPED AND YES YES CONTAIN AT LEAST (1) 3 IN CAL. SHADE TREEPERIMETER LANDSCAPING [SEC. 12-34-8 (C)]: - ALL PARKING AND VEHICULAR USE AREAS, INCLUDINGYES YES DRIVEWAYS, SHALL BE SCREENED FROM ABUTTING PROPERTIES/ PUBLIC R.O.W.S WITH A 30 IN HEDGE - PERIMETERS /R.O.W.S SHALL CONTAIN 1 TREE PER 50 LF OF PERIMETER LANDSCAPE AREA-NORTH PROPERTY LINE: (10' BUFFER/ 8,162 SF)17 TREES 13 EXISTING841/50 = 17 TREES 6 PROPOSED*-EAST PROPERTY LINE: (10' BUFFER/ 10,470 SF)22 TREES 22 PROPOSED*1,069/50 = 22 TREES-SOUTH PROPERTY LINE: (15' BUFFER/ 12,831 SF)18 TREES 9 EXISTING870/50 = 18 TREES 9 PROPOSED-WEST PROPERTY LINE: (15' BUFFER/ 8,703 SF)17 TREES 7 EXISTING841/50 = 17 TREES 10 PROPOSEDNON-VEHICULAR LANDSCAPING [SEC. 12-34-9 (A)]: - 15% OF NON-VEHICULAR SPACE THAT IS NOT COVERED 7,391 SF IN 32,865 SF IN BY BUILDINGS SHALL BE DEVOTED TO FEATUREFRONT YARD FRONT YARD LANDSCAPING WITH 50% LOCATED IN FRONT YARD(S) 49,273 SF (OF NON-VEHICULAR OS) X .15 = 7,391 SF -TREES SHALL BE PLANTED IN NON-VEHICULAR OPEN SPACE20 TREES 20 PROPOSED AT A RATE OF 1 TREE/ 2,500 SF 49,273 SF/ 2,500 = 20 TREESTOTAL LANDSCAPE AREA REQUIREMENTS: - TOTAL OF ALL LANDSCAPE AREAS ABOVE: 59,319 SF 117,231 SF - TOTAL OF ALL PROPOSED TREES ABOVE:142 TREES 113 PROPOSED* 29 EXISTING*NOTE: SOME CANOPY TREE REQUIREMENTS ARE MET WITH ORNAMENTAL TREES AT A 3:1 RATIODUE TO UTILITY AND AREA CONFLICTS.PLANT SCHEDULETREES CODE QTY COMMON NAMESIZE QM 24 Chinkapin Oak 3" CAL. UC 29 Cedar Elm 3" CAL. QV 35 Live Oak 3" CAL.SHRUBS CODE QTY COMMON NAME AG 704 Glossy Abelia 5 GAL.GROUND COVER CODE QTY COMMON NAME TA 4,274 Asian Jasmine 1 GAL. EF 10,597 Wintercreeper 1 GAL.MISC. CODE QTY COMMON NAME SOD TBD Bermuda Grass STEEL TBD EDGE MULCH TBD Shredded hardwood mulch. LM 2,672 Liriope 1 GAL. LI 37 Crape Myrtle 2" CAL. VA 44 Chaste Tree 2" CAL.
WWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSNO PARKINGNO PARKINGNO PARKINGNO PARKINGINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREEINTERIOR TREESOUTH PERIMETER TREESOUTH PERIMETER TREESOUTH PERIMETER TREE15' PERIMETERLANDSCAPE BUFFER10' PERIMETERLANDSCAPE BUFFER10' PERIMETERLANDSCAPE BUFFER2' MULCH BEDSTEEL EDGING2' MULCH BEDSTEEL EDGINGOPEN SPACE TREEOPEN SPACE TREEEAST PERIMETER TREEEAST PERIMETER TREEEAST PERIMETER TREEEAST PERIMETER TREEQV2QM2QM3UC3QV5QM1TA125TA125LM92LM88LM92TA131LM88LM127TA123TA127TA130LM157TA107EF471EF471EF500EF500EF500LM88LM88AG127AG125UC13LI8VA9LI7LI9INTERIOR TREEENTRY SIGNREVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2022CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SEEFRIED COPPELL!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesBMLOCT. 2022CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:10821-00\\browngay.net\panzura\Regions\TXN\Projects\Seefried_Industrial_Props\10821-00-16_Acres_Coppell_TX\LP-NTX\03-CAD\03-SHEETS\10821-L2_PLNT PLAN.dwg Oct 11, 2022-3:57pm blevyBGE, INC.
SEEFRIED COPPELL
WBMBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.3030 LBJ Freeway, Suite 1650SEEFRIED INDUSTRIALDallas, TX 75234OWNER/DEVELOPERContact:Jonathan StitesTel: 214-393-60665310 Harvest Hill Rd, Suite 180PROSS DESIGN GROUP, INC.Dallas, Texas 75230ARCHITECTContact:Mark ProssTel: 972-759-1400LANDSCAPE PLAN
L2.5PROPERTY LINE -
LIMIT OF WORK
SEE SHEET L2.3 (MATCHLINE)SEE SHEET L2.2 (MATCHLINE)PROPERTY LINE -LIMIT OF WORKNOTE: ABOVE PLANT NAMES AND QUANTITIES ARE PROVIDED FOR CONVENIENCEIF THERE IS A DISCREPANCY, REFER TO THE PLAN FOR ACCURATE QUANTITIES.NOTE: REFER TO PLANTING NOTES FOR APPROVED INSTALLATION PRACTICES TOMEET THE DESIGN INTENT OF THE PLAN.NOTE: PRESERVED TREE DATA CAN BE FOUND ON PAGE TP1.3COPPELL LANDSCAPE REQUIREMENTS Required ProvidedINTERIOR LANDSCAPING [SEC. 12-34-8 (B)]: - 10% OF GROSS NONEXEMPT PARKING AND LOADING 19,153 SF 22,403 SF AREA SHALL BE LANDSCAPED 191,522SF X 10% = 19,153 SF - (1) 3 IN CAL. SHADE TREE FOR EVERY 400 SF 48 TREES 49 TREES OF REQ. INTERIOR LANDSCAPE 19,153 / 400 = 48 TREES - LANDSCAPE ISLANDS MUST BE LANDSCAPED AND YES YES CONTAIN AT LEAST (1) 3 IN CAL. SHADE TREEPERIMETER LANDSCAPING [SEC. 12-34-8 (C)]: - ALL PARKING AND VEHICULAR USE AREAS, INCLUDINGYES YES DRIVEWAYS, SHALL BE SCREENED FROM ABUTTING PROPERTIES/ PUBLIC R.O.W.S WITH A 30 IN HEDGE - PERIMETERS /R.O.W.S SHALL CONTAIN 1 TREE PER 50 LF OF PERIMETER LANDSCAPE AREA-NORTH PROPERTY LINE: (10' BUFFER/ 8,162 SF)17 TREES 13 EXISTING841/50 = 17 TREES 6 PROPOSED*-EAST PROPERTY LINE: (10' BUFFER/ 10,470 SF)22 TREES 22 PROPOSED*1,069/50 = 22 TREES-SOUTH PROPERTY LINE: (15' BUFFER/ 12,831 SF)18 TREES 9 EXISTING870/50 = 18 TREES 9 PROPOSED-WEST PROPERTY LINE: (15' BUFFER/ 8,703 SF)17 TREES 7 EXISTING841/50 = 17 TREES 10 PROPOSEDNON-VEHICULAR LANDSCAPING [SEC. 12-34-9 (A)]: - 15% OF NON-VEHICULAR SPACE THAT IS NOT COVERED 7,391 SF IN 32,865 SF IN BY BUILDINGS SHALL BE DEVOTED TO FEATUREFRONT YARD FRONT YARD LANDSCAPING WITH 50% LOCATED IN FRONT YARD(S) 49,273 SF (OF NON-VEHICULAR OS) X .15 = 7,391 SF -TREES SHALL BE PLANTED IN NON-VEHICULAR OPEN SPACE20 TREES 20 PROPOSED AT A RATE OF 1 TREE/ 2,500 SF 49,273 SF/ 2,500 = 20 TREESTOTAL LANDSCAPE AREA REQUIREMENTS: - TOTAL OF ALL LANDSCAPE AREAS ABOVE: 59,319 SF 117,231 SF - TOTAL OF ALL PROPOSED TREES ABOVE:142 TREES 113 PROPOSED* 29 EXISTING*NOTE: SOME CANOPY TREE REQUIREMENTS ARE MET WITH ORNAMENTAL TREES AT A 3:1 RATIODUE TO UTILITY AND AREA CONFLICTS.PLANT SCHEDULETREES CODE QTY COMMON NAMESIZE QM 24 Chinkapin Oak 3" CAL. UC 29 Cedar Elm 3" CAL. QV 35 Live Oak 3" CAL.SHRUBS CODE QTY COMMON NAME AG 704 Glossy Abelia 5 GAL.GROUND COVER CODE QTY COMMON NAME TA 4,274 Asian Jasmine 1 GAL. EF 10,597 Wintercreeper 1 GAL.MISC. CODE QTY COMMON NAME SOD TBD Bermuda Grass STEEL TBD EDGE MULCH TBD Shredded hardwood mulch. LM 2,672 Liriope 1 GAL. LI 37 Crape Myrtle 2" CAL. VA 44 Chaste Tree 2" CAL.
NOTE:THIS DETAIL IS DRAWN TO SHOW THE INTENDED PLANTING LAYOUT OFADJACENT SHRUB BEDS ALONG CURVES. CONTRACTOR TO PLANT ALLPERIMETERS OF BED AREAS AS SHOWN AND THEN PLANT THE REMAINDEROF THE BED TRIANGULARLY AT THE SPECIFIED SPACING.SHRUB BED DIVISION LINE (BETWEENADJACENT SHRUB BEDS) AS SHOWNON PLANTEING PLANS.SHRUBS PLANTED AT 9"-24" O.C.SHRUBS PLANTED AT 24"-40" O.C.1/2 PLANT SPACING1/2 PLANT SPACING12" MIN.REVISIONSREV NO.DATEDESCRIPTIONDESIGNED BY:DATE:PROJECT NUMBER:SHEET NO.2595 Dallas Parkway, Suite 101BGE, Inc.Frisco, TX 75034TBPE Registration No. F-1046Tel: 972-464-4800 ●www.bgeinc.comCopyright 2022CONTACT: 1-800-DIG-TESS48 HOURS PRIOR TO CONSTRUCTIONCAUTION !!!SEEFRIED COPPELL!!CAUTION !!Contractor to Verify exact location & Depth ofExist Facilities Prior to any ConstructionActivitiesBMLOCT. 2022CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:10821-00\\browngay.net\panzura\Regions\TXN\Projects\Seefried_Industrial_Props\10821-00-16_Acres_Coppell_TX\LP-NTX\03-CAD\03-SHEETS\10821-L2_PLNT PLAN.dwg Oct 11, 2022-3:57pm blevyBGE, INC.
SEEFRIED COPPELL
WBMBEFORE YOU DIG, CALL DIG TESS1-800-DIG-TESS!!WARNING!!EXISTING UNDERGROUND UTILITIES. CONTRACTORSHALL VERIFY THE EXACT LOCATION OF ALL UTILITIESAND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION.3030 LBJ Freeway, Suite 1650SEEFRIED INDUSTRIALDallas, TX 75234OWNER/DEVELOPERContact:Jonathan StitesTel: 214-393-60665310 Harvest Hill Rd, Suite 180PROSS DESIGN GROUP, INC.Dallas, Texas 75230ARCHITECTContact:Mark ProssTel: 972-759-1400PLANT SCHEDULETREES CODE QTY BOTANICAL / COMMON NAME SIZEREMARKS QM 24 Quercus muehlenbergii / Chinkapin Oak3" CAL. 10'-12' HT, 5'-7' SP. B&B UC 29 Ulmus crassifolia / Cedar Elm3" CAL. 10'-12' HT, 5'-7' SP. B&B QV 35 Quercus virginiana / Live Oak3" CAL. 10'-12' HT, 5'-7' SP. B&BSHRUBS CODE QTY BOTANICAL / COMMON NAME AG 704 Abelia grandiflora / Glossy Abelia5 GAL. MIN. 30" HT., 30" SP., 36" O.C.GROUND COVER CODE QTY BOTANICAL / COMMON NAME TA 4,274 Trachelospermum asiaticum / Asian Jasmine1 GAL. MIN. 8" HT., 8" SP., 12" O.C. EF 10,597 Euonymus fortunei 'Coloratus' / Wintercreeper1 GAL. MIN. 8" HT., 8" SP., 12" O.C.MISC. CODE QTY BOTANICAL / COMMON NAME SOD TBD Cynodon dactylon / Bermuda Grass SOLID SOD. FULL, WELL-ROOTED. 100% WEED AND PEST FREE. STEEL TBD 3/16" X 4" BLACK EDGE MULCH TBD Shredded hardwood mulch. ALL PROPOSED TREES TO RECEIVE 4' DIAMETER MULCH RING. LM 2,672 Liriope muscari 'Variegata' / Liriope1 GAL. MIN. 8" HT., 8" SP., 12" O.C.LANDSCAPE NOTES1.ALL PLANT MATERIAL LOCATIONS SHALL BE STAKED FOR APPROVAL BY LANDSCAPE ARCHITECT PRIOR TO EXCAVATION. LANDSCAPE ARCHITECTRESERVES RIGHT TO ADJUST PLANTS TO EXACT LOCATION IN FIELD.2.CONTRACTOR IS RESPONSIBLE FOR VERIFYING SITE INFORMATION, INCLUDING PROPERTY LINES, EASEMENTS, BUILDINGS, ROADWAY CURB AND GUTTERS,UTILITIES AND OTHER INFORMATION AFFECTING THE SCOPE OF WORK INCLUDED ON THESE DRAWINGS. MORE SPECIFIC UTILITY INFORMATION ISINDICATED ON OTHER CONSULTANTS' DRAWINGS AND SITE RECORD DRAWINGS AVAILABLE FROM THE OWNER. THE CONTRACTOR SHALL CONTACT THEOWNER AND THE LANDSCAPE ARCHITECT FOR DIRECTION ON HOW TO PROCEED IF ACTUAL SITE CONDITIONS VARY FROM WHAT IS SHOWN ON THE CIVILENGINEERING OR LANDSCAPE ARCHITECTURE PLANS. ANY DAMAGE TO EXISTING SITE UTILITIES CAUSED BY ANY PERSON, VEHICLE, EQUIPMENT OR TOOLRELATED TO THE EXECUTION OF THIS SCOPE OF WORK SHALL BE REPAIRED IMMEDIATELY AT NO EXPENSE TO THE OWNER.3.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ADVISE THE LANDSCAPE ARCHITECT OF ANY CONDITION FOUND ON THE SITE WHICH PROHIBITSINSTALLATION AS SHOWN ON THESE DRAWINGS.4.LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR FINE GRADING, REMOVAL OF MISCELLANEOUS DEBRIS AND ANY ADDITIONAL FILL REQUIRED TOACHIEVE FINISH GRADE PRIOR TO PLANTING IN ALL AREAS.5.FINAL GRADING SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT IN THE FIELD PRIOR TO PLANTING.6.AN AUTOMATIC IRRIGATION SYSTEM PROVIDING 100% COVERAGE OF ALL LANDSCAPE AREAS IS REQUIRED. OVERSPRAY ON STREETS AND WALKS ISPROHIBITED.7.PLANT SPACING IS AS INDICATED ON 'PLANT LEGEND' UNLESS OTHERWISE NOTED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE FULL PLANTCOVERAGE IN ALL LANDSCAPE AREAS AS SPECIFIED IN THE PLANT LEGEND REMARKS.8.TREES SHALL BE PLANTED AS LEAST FIVE (5') FEET FROM ANY UTILITY LINE, CURB, SIDEWALK OR FIRE CONNECTION AND OUTSIDE ALL UTILITY EASEMENTS.9.TREES OVERHANGING SIDEWALKS AND PARKING OR PEDESTRIAN AREAS SHALL HAVE A MINIMUM CLEAR TRUNK BRANCHING HEIGHT OF SEVEN (7') FEET.10.TREES OVERHANGING VISIBILITY EASEMENTS OR RIGHT-OF WAYS SHALL HAVE A MINIMUM CLEAR TRUNK HEIGHT OF NINE (9') FEET.11.TREES OVERHANGING PUBLIC STREET PAVEMENT WILL HAVE A MINIMUM CLEAR TRUNK OF FOURTEEN (14') FEET.12.ALL TREES TO BE STAKED AND INCLUDED AT LEAST 3 INCHES OF HARDWOOD MULCH OVER PLANTING AREA13.ALL SHRUB, GROUNDCOVER & PERENNIAL SHALL HAVE A MIN. THREE (3") HARDWOOD MULCH..14.ANNUAL BEDS TO RECEIVE MINIMUM 3" HARDWOOD MULCH15.ALL PLANT MATERIAL SHALL BE MAINTAINED IN A HEALTHY AND GROWING CONDITION, AND MUST BE REPLACED WITH PLANT MATERIAL OF SIMILAR VARIETYAND SIZE IF DAMAGED, DESTROYED, OR REMOVED.16.LANDSCAPED AREAS SHALL BE KEPT FREE OF TRASH, LITTER, AND WEEDS AT ALL TIMES DURING CONSTRUCTION.17.ALL LANDSCAPE BEDS TO RECEIVE STEEL EDGING WITHIN GROUND COVER AND SHRUB AREAS THAT ARE ADJACENT TO TURF.18.PLANT MATERIAL SHALL BE MEASURED AND SIZED ACCORDING THE LATEST EDITION OF THE AMERICAN STANDARDS FOR NURSERY STOCK (ANSI Z60.1).19.CONTRACTOR SHALL PROVIDE THE PROJECT AGRONOMIST SOIL SAMPLES. A MINIMUM OF TWO SAMPLES FROM EACH DIFFERENT SOIL AREA AND FROMEACH IMPORT SOIL SOURCE IS REQUIRED. VERIFY APPROPRIATE QUANTITY OF SAMPLES WITH THE LANDSCAPE ARCHITECT AND AGRONOMIST. SAMPLESSHALL THEN BE TESTED AND ANALYZED FOR AGRICULTURAL SUITABILITY AND FERTILITY BY AN ACCREDITED SOIL TESTING LABORATORY. ANALYSES SHALLINCLUDE REVIEW AND COORDINATION WITH THE SPECIFICATIONS AND RECOMMENDATIONS FOR SOIL PREPARATION AND BACK FILL MIX. SUBMIT SOILANALYSES TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO SOIL PREPARATION. THIS REQUIREMENT APPLIES TO ALL SOILS AND CONDITIONS WITHINTHIS PROJECT INCLUDING IMPORT SOILS, ON GRADE SOILS AND/OR ON-STRUCTURE SOILS. VERIFYING ON-STRUCTURE FILTER FABRIC/SOIL COMPATIBILITYSHALL BE PART OF THE OVERALL ANALYSIS. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.20.TOPSOIL SHALL BE A MINIMUM OF 4" IN DEPTH. SOIL SHALL BE FREE OF STONES, ROOTS AND ANY OTHER FOREIGN MATERIAL THAT IS NOT BENEFICIAL FORPLANT GROWTH.21.REFER TO CIVIL FOR GRADING AND UTILITY COORDINATION.22.APPROXIMATE LIMITS OF SEEDING AND SODDING ARE SHOWN AS ON PLAN; CONTRACTOR TO PROVIDE SOD ON ALL AREAS DISTURBED BY CONSTRUCTION.23.CONTRACTOR TO VERIFY CONSTRUCTION COMPLIANCE WITH ADA. NOTIFY PROJECT ENGINEER OF ANY DISCREPANCIES.24.CONTRACTOR TO PROVIDE NECESSARY EROSION CONTROL MEASURES AS NEEDED.25.ALL CONSTRUCTION SHALL CONFORM TO THE PLANS AND SPECIFICATIONS PROVIDED HEREIN OR OTHERWISE TO CITY OF KAUFMAN COUNTY STANDARDS.TREE STAKING NOTES:1. STAKE ALL TREES 2" CALIPER AND ABOVE.2. LOCATE STAKES OUTSIDE OF TREE WELL POSITION STAKES TO SECURE TREE AGAINSTSEASONAL PREVAILING WINDS.4" HIGH WATERING RINGFINISH GRADEMETAL T-POSTS PAINTED GREENROOT BALL, DO NOT DISTURB. TOPOF ROOT BALL TO BE SET 1" ABOVEEXISTING GRADE. REMOVE TOP 1/3 BURLAP.SCARIFY SIDESDO NOT CUT CENTRAL LEADERNYLON STRAPPINGNATIVE SOILPREPARED SOIL MIX PER SPECS.ROOT BALL, DO NOT DISTURBFINISH GRADE3" LAYER OF ROCK MULCHREF. PLAN FOR SHRUB TYPE4'- 5' MTG. HT.
IF REQUIRED
3" LAYER MULCH, REF. SPECIFICATIONS2X DIAMETEROF ROOT BALL4" DIAMETER PERFORATEDPVC PIPE W/CAP.6"6"4" HIGH WATERING RINGFINISH GRADEMETAL T-POSTS PAINTED GREENNATIVE SOIL, REF. SPECIFICATIONSCRUSHED ROCKSCARIFY SIDES6"DO NOT CUT CENTRAL LEADERREFERENCE PLAN FOR TREE TYPENYLON STRAPPINGSPACING PER PLAN6"NATIVE SOILPREPARED SOIL MIX PER SPECS.ROOT BALL, DO NOT DISTURBFINISH GRADEREF. PLAN FOR SHRUB TYPEPLAN3/4" MAXIMUM1/8" X 4" GREEN STEEL EDGINGWITH STAKESLAWNNOTE:NO STEEL EDGING TO BEINSTALLED ALONG SIDEWALKS.SEE LANDSCAPE NOTES #16 ONSHEET L1.03 & DETAIL D/L1.03LANDSCAPE NOTES & SPECIFICATIONS
L2.6COPPELL LANDSCAPE REQUIREMENTS Required ProvidedINTERIOR LANDSCAPING [SEC. 12-34-8 (B)]: - 10% OF GROSS NONEXEMPT PARKING AND LOADING 19,153 SF 22,403 SF AREA SHALL BE LANDSCAPED 191,522SF X 10% = 19,153 SF - (1) 3 IN CAL. SHADE TREE FOR EVERY 400 SF 48 TREES 49 TREES OF REQ. INTERIOR LANDSCAPE 19,153 / 400 = 48 TREES - LANDSCAPE ISLANDS MUST BE LANDSCAPED AND YES YES CONTAIN AT LEAST (1) 3 IN CAL. SHADE TREEPERIMETER LANDSCAPING [SEC. 12-34-8 (C)]: - ALL PARKING AND VEHICULAR USE AREAS, INCLUDINGYES YES DRIVEWAYS, SHALL BE SCREENED FROM ABUTTING PROPERTIES/ PUBLIC R.O.W.S WITH A 30 IN HEDGE - PERIMETERS /R.O.W.S SHALL CONTAIN 1 TREE PER 50 LF OF PERIMETER LANDSCAPE AREA-NORTH PROPERTY LINE: (10' BUFFER/ 8,162 SF)17 TREES 13 EXISTING841/50 = 17 TREES 6 PROPOSED*-EAST PROPERTY LINE: (10' BUFFER/ 10,470 SF)22 TREES 22 PROPOSED*1,069/50 = 22 TREES-SOUTH PROPERTY LINE: (15' BUFFER/ 12,831 SF)18 TREES 9 EXISTING870/50 = 18 TREES 9 PROPOSED-WEST PROPERTY LINE: (15' BUFFER/ 8,703 SF)17 TREES 7 EXISTING841/50 = 17 TREES 10 PROPOSEDNON-VEHICULAR LANDSCAPING [SEC. 12-34-9 (A)]: - 15% OF NON-VEHICULAR SPACE THAT IS NOT COVERED 7,391 SF IN 32,865 SF IN BY BUILDINGS SHALL BE DEVOTED TO FEATUREFRONT YARD FRONT YARD LANDSCAPING WITH 50% LOCATED IN FRONT YARD(S) 49,273 SF (OF NON-VEHICULAR OS) X .15 = 7,391 SF -TREES SHALL BE PLANTED IN NON-VEHICULAR OPEN SPACE20 TREES 20 PROPOSED AT A RATE OF 1 TREE/ 2,500 SF 49,273 SF/ 2,500 = 20 TREESTOTAL LANDSCAPE AREA REQUIREMENTS: - TOTAL OF ALL LANDSCAPE AREAS ABOVE: 59,319 SF 117,231 SF - TOTAL OF ALL PROPOSED TREES ABOVE:142 TREES 113 PROPOSED* 29 EXISTING*NOTE: SOME CANOPY TREE REQUIREMENTS ARE MET WITH ORNAMENTAL TREES AT A 3:1 RATIODUE TO UTILITY AND AREA CONFLICTS. LI 37 Lagerstroemia indica/ Crape Myrtle45 GAL. 8'-10' HT MULTI-TRUNK, 3 CANE MIN. CONTAINER VA 44 Vitex agnus-castus / Chaste Tree45 GAL. 8'-10' HT MULTI-TRUNK, 3 CANE MIN. CONTAINER