Site PlanLEGEND
PROPERTY LINE
NOTES:
1.CONTRACTOR TO NOTIFY ENGINEER IF EXISTING CONDITIONS VARY
FROM THOSE SHOWN.
2.ALL WORK AND MATERIALS SHALL COMPLY WITH CITY AND COUNTY
REGULATIONS AS WELL AS O.S.H.A STANDARDS.
3.ALL DIMENSIONS ARE TO THE FACE OR CURB UNLESS OTHERWISE
NOTED.
4.ALL FIRE LANE RADII ARE 30-FEET MINIMUM.
5.ALL FIRE LANES ARE 24-FEET WIDE MINIMUM.
6.HANDICAP PARKING AND MARKING SHALL BE IN ACCORDANCE WITH
ADA STANDARDS.
7.REFER TO CITY OF COPPELL CONSTRUCTION DETAILS AND
SPECIFICATIONS.
8.ALL SCREENING SHALL BE IN ACCORDANCE WITH CITY OF COPPELL
REQUIREMENTS.
9.CONTRACTOR TO COORDINATE WITH CITY TRAFFIC ENGINEER PRIOR
TO INSTALLING ROAD SIGNS OR PAVEMENT MARKINGS.
10.REFER TO LANDSCAPE AND ARCHITECTURAL PLANS FOR FINAL
SIDEWALK LAYOUT.
11.CONTRACTOR TO COORDINATE WITH RESPECTIVE COMPANY FOR
ANY RELOCATIONS, INCLUDING POWER POLES, LIGHT POLES, AND
ELECTRICAL BOXES
12.REFERENCE GEOTECHNICAL REPORT FOR BUILDING PAD AND PAVING
SUBGRADE PREPARATION.
KEY
TYP TYPICAL
BFR BARRIER FREE RAMP
FH FIRE HYDRANT
SSMH SEWER MANHOLE
LP LIGHT POLE
PP POWER POLE
ESMT EASEMENT
NUMBER OF PARKING SPACES
STMH STORM MANHOLE
WYE WYE INLET
FDC FIRE DEPARTMENT CONNECTION
EXISTING MANHOLE
EXISTING FIRE HYDRANT
EASEMENT LINE
BARRIER FREE RAMP
PROPOSED CURB INLET
PROPOSED GATE VALVE
FIRE DEPARTMENT CONNECTION
PROPOSED FIRE HYDRANT ASSEMBLY
PROPOSED MANHOLE
PROPOSED DOMESTIC METER
PROPOSED IRRIGATION METER
PROPOSED WYE INLET
POWER POLE
BIKE RACKS
CI CURB INLET
BUILDING 1
120,120 SF
FFE: 542.50
(42' HEIGHT)BUILDING 2
161,720 SF
FFE: 540.50
(42' HEIGHT)
13
14
5 14
12
9
9
9
9
9
16 16
16 8 7
1211
55 7
3
5
1255
12
11
4
6
12
12
11
12
10
9
8
8
R330'
R 3 0 'R30'R 2 5 'R5
4'R30
'R24'R15 'R30'R30'R 3 0 0 '
R 3 0 1'R54'R
3
0'R50'R74'R5 0 '
R 9 3 'R25 'R1
5'R3
0'R30'R
3
0'
R 30'R10'
R 30'R
3
0'
R 10'R
1
0'
R
15'R 15'NO PARKING NO PARKING NO PARKING NO PARKING
NO PARKING NO PARKING NO PARKING NO PARKING
R 1
5'R 1 5'R 10'R24'R30'R
2
5'
HOODED
MEDIAN BREAK
5' CITY SIDEWALK
SCREEN WALLS
(12 FEET TALL)
GI
GI
GI
CI
CI
CI
CI
CI
CI
CI
FH
FH
FH
FH
FH
FHFH
FH
FH
FH
FH
FH
FDC
FDC
PROPOSED
BOLLARDS
PROPOSED
BOLLARDS
BFR
10'24'19'9'9'30'220'
40'
40'90'90'24'STAIRS
STAIRS
STAIRS
STAIRS
STAIRS
STAIRS
STAIRS
STAIRS
STAIRS
STAIRS
STAIRS
STAIRS
PROPOSED 24' FIRE
LANE, ACCESS AND
UTILITY EASEMENT
PROPOSED 24' FIRE
LANE, ACCESS AND
UTILITY EASEMENT
PROPOSED 30' FIRE LANE,
ACCESS AND UTILITY
EASEMENT
PROPOSED 40' FIRE
LANE, ACCESS AND
UTILITY EASEMENT
PROPOSED 24' FIRE
LANE, ACCESS AND
UTILITY EASEMENT
19'9'19'19'24'19'PROPOSED 24' FIRE LANE,
ACCESS AND UTILITY
EASEMENT
24'30'5' SIDEWALK
5' SIDEWALK
5' SIDEWALK
5' SIDEWALK5' SIDEWALK
5' SIDEWALK
5' SIDEWALK
5' SIDEWALK
5' SIDEWALK
PROPOSED RET. WALK
WITH GUARDRAIL
/
/
////OHEOHEOHEOHEOHEOHE
OHE
OHE
OHE
OHE
OHE
OHE
OHEOHEOHEOHEOHEOHEOHE//////////////////N 56°51'16" W 48.73'N 00°02'51" W 1068.45'GAT
E
W
A
Y
B
O
U
L
E
V
A
R
D
////////////////////////////////////////////////(VARI
A
B
L
E
W
I
D
T
H
)(VARIABLE WIDTH)INT
E
R
S
T
A
T
E
H
I
G
H
W
A
Y
N
O
.
6
3
5
L.B.
J
.
F
R
W
Y
(VARI
A
B
L
E
W
I
D
T
H
P
U
B
L
I
C
R
I
G
H
T
-
O
F
-
W
A
Y
)SOUTH ROYAL LANE/
/
////OHEOHEOHEOHEOHE//////////////////GAT
E
W
A
Y
B
O
U
L
E
V
A
R
D
////////////////////////////////////////////////(VARI
A
B
L
E
W
I
D
T
H
)(VARIABLE WIDTH)INT
E
R
S
T
A
T
E
H
I
G
H
W
A
Y
N
O
.
6
3
5
L.B.
J
.
F
R
W
Y
(VARI
A
B
L
E
W
I
D
T
H
P
U
B
L
I
C
R
I
G
H
T
-
O
F
-
W
A
Y
)
ST. LOUIS & SOUT
H
W
E
S
T
E
R
N
R
A
I
L
R
O
A
D
SCREEN WALL
(12 FEET TALL)
24'
30'
BUILDING
SETBACK
REMOVE
EXIST
BILLBOARD
REMOVE
EXIST
BILLBOARD160'325'
MONUMENT
SIGN
MONUMENT
SIGN
AI
JB
JB
JB
JB
JB
FH
LIGHT POLE
LIGHT POLE
BARRIER
FREE
RAMPS
SP-1SITE PLANREVISIONS
REV NO.DATE DESCRIPTION
DESIGNED BY:
DATE:
PROJECT NUMBER:
SHEET NO.
2595 Dallas Parkway, Suite 101
BGE, Inc.
Frisco, TX 75034
TBPE Registration No. F-1046
Tel: 972-464-4800 ●www.bgeinc.com
Copyright 2022
CONTACT: 1-800-DIG-TESS
48 HOURS PRIOR TO CONSTRUCTION
CAUTION !!!SEEFRIED ADDITION!!CAUTION !!
Contractor to Verify exact location & Depth of
Exist Facilities Prior to any Construction
Activities
EJB
SEPTEMBER 2022 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY:
10821-00G:\TXN\Projects\Seefried_Industrial_Props\10821-00-16_Acres_Coppell_TX\LD-NTX\01_CADD\01_SHTS\COPPELL_SITE PLAN.dwg Oct 10, 2022-2:53pm jkhalfanBGE, INC.SEEFRIED COPPELLNDH
BEFORE YOU DIG, CALL DIG TESS
1-800-DIG-TESS
3030 LBJ Freeway, Suite 1650
SEEFRIED INDUSTRIAL
Dallas, TX 75234
OWNER/DEVELOPER
Contact:Jonathan Stites
Tel: 214-393-6066
5310 Harvest Hill Rd, Suite 180
PROSS DESIGN GROUP, INC.
Dallas, Texas 75230
ARCHITECT
Contact:Mark Pross
Tel: 972-759-1400
THESE PLANS ARE ISSUED FOR
THE PURPOSE OF PRELIMINARY
REVIEW AND ARE NOT INTENDED FOR
CONSTRUCTION.
WHEN ISSUED IN
FINAL FORM THEY WILL BE
SEALED, SIGNED AND DATED.
RESPONSIBLE ENGINEER:
BGE, INC.
TEXAS REGISTERED ENGINEERING
FIRM F-1046
NICHOLAS D. HOBBS, P.E.
TEXAS REGISTRATION NO. 112949
OCTOBER 10, 2022LOT 1, BLOCK A16.071 ACRESBASE ZONING: LIGHT INDUSTRIALROYAL LNGATEWAY BLVDLBJ
F
W
Y
I
H
6
3
5
ST. LOUIS & SOUTHERN
R
A
I
L
R
O
A
D
EXCHANGE CIRCLEVICINITY MAP
(NOT TO SCALE)
PNF-DALLAS, LLC
2060 Mt. Paran Rd., N.W., Ste 207
Atlanta, GA 30327
OWNER