Landscape Plans_v150'
I
N
G
R
E
S
S
&
EG
R
E
S
S
E
A
S
E
M
E
N
T
VO
L
.
9
5
2
2
5
,
P
G
.
1
7
7
2
D.
R
.
D
.
C
.
T
.
S 53°
1
9'
2
4"
W
3
2
8.
3
9'S 00°13'20" E 180.03'S 89°30'20" W 336.81'
N 03°44'55" W 24.59'N 24°11
'56
"
W48.78
'
S 69°
4
7
'
1
5
"
E
2
0
9
.
4
4
'
APPROX.
LOCATION
ZONE AE
(SFHA)
APPROX.
LOCATION
ZONE X
(NFHA)
APPROX.
LOCATION
ZONE X
(SHADED)
WATER
N 48°08'57" E 188.38'
N 43°09'22" E 33.80'
N 48°22'09" E 349.33'
100' BRAZOS ELECTRIC
POWER COOPERATIVE INC.
EASEMENT
VOL. 90122, PG. 3403
D.R.D.C.T.
20'
E
A
S
E
M
E
N
T
VO
L
.
7
9
0
7
4
,
P
G
.
4
7
D.
R
.
D
.
C
.
T
.
50'
I
N
G
R
E
S
S
&
EG
R
E
S
S
E
A
S
E
M
E
N
T
VO
L
.
9
5
2
2
5
,
P
G
.
1
7
7
2
D.
R
.
D
.
C
.
T
.
SANITARY
SEWER
MANHOLE
RIM = 483.67'
SANITARY
SEWER
MANHOLE
RIM = 478.79'101102103104105106108107110111109114115112113116117118120119156155154153127147150129128126121122123124125130131132133134135136137138139161160159158157149162163167166186188189190191192193187196195221225224228229227231233234235236237238239240241242243244245246247248249250251252180179178177176140141143142144145148146152151164165168169170171172173174175181182185204183184210211207208206209212213232226197198199200201194218219220222223214215216230217202203205253254255256257258259260261262263TREE SURVEY TOTALS:
TOTAL NET PROTECTED TREES ON SITE: 2,176 CALIPER INCHES
TOTAL PROTECTED TREES REMOVED (GROSS RETRIBUTION): 1,140 CALIPER INCHES
TOTAL PROTECTED TREES PRESERVED: 1,036 CALIPER INCHES
1,036/2,176 = 48% PRESERVED
1,140 X 48% = 547 PRESERVATION CREDIT
1,140-547 = 593" REQUIRED MITIGATION
TOTAL TREES ON SITE: 2,192 CALIPER INCHES TOTAL
UNHEALTHY TREES REMOVED: 0 CALIPER INCHES
EXISTING TREE TO BE REMOVED499
499
EXISTING TREE TO BE REMOVED
KEY
(PROTECTED)
(UNPROTECTED)
GAC
NOV 14 2022
Revisions
Drawn By
Checked By GAC
CDate
1921 MAPLEWOOD DRIVEWEATHERFORD, TX 76087 682-215-9151THIS ELECTRONIC DRAWING FILE IS RELEASED UNDER THE AUTHORITY OF GREGORY CUPPETT, LICENSEDIRRIGATOR & LANDSCAPE ARCHITECT (LICENSED IRRIGATOR NUMBER 0023539, LANDSCAPE ARCHITECT REGISTRATION NUMBER 2672) ON 11/14/22 WHO MAINTAINS THE ORIGINAL FILE. THIS ELECTRONICRULES AND REGULATIONS OF THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS AND THE RULES ANDELECTRONIC DRAWING FILE AGREES TO ASSUME ALL RESPONSIBILITY FOR ANY MODIFICATION TO ORUSE OF THIS DRAWING FILE THAT IS INCONSISTENT WITH THE REQUIREMENTS OF THE RULES ANDREGULATIONS OF THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS AND THE TEXAS DEPARTMENT OF LICENSING AND REGULATION. NO PERSON MAY MAKE MODIFICATIONS TO THIS ELECTRONICDRAWING FILE WITHOUT THE IRRIGATOR/LANDSCAPE ARCHITECT'S EXPRESS WRITTEN PERMISSION.DRAWING FILE MAY BE USED AS A BACKGROUND DRAWING. PURSUANT TO RULE 3.103(F) OF THE REGULATIONS OF THE TEXAS DEPARTMENT OF LICENSING AND REGULATION, THE USER OF THISTREE SURVEY
34 X 4" =136" PLANTED
460" PAID TO FUND = $69,600
499
EXISTING TREE TO BE PRESERVED
GAC
NOV 14 2022
Revisions
Drawn By
Checked By GAC
CDate
1921 MAPLEWOOD DRIVEWEATHERFORD, TX 76087 682-215-9151THIS ELECTRONIC DRAWING FILE IS RELEASED UNDER THE AUTHORITY OF GREGORY CUPPETT, LICENSEDIRRIGATOR & LANDSCAPE ARCHITECT (LICENSED IRRIGATOR NUMBER 0023539, LANDSCAPE ARCHITECT REGISTRATION NUMBER 2672) ON 11/14/22 WHO MAINTAINS THE ORIGINAL FILE. THIS ELECTRONICRULES AND REGULATIONS OF THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS AND THE RULES ANDELECTRONIC DRAWING FILE AGREES TO ASSUME ALL RESPONSIBILITY FOR ANY MODIFICATION TO ORUSE OF THIS DRAWING FILE THAT IS INCONSISTENT WITH THE REQUIREMENTS OF THE RULES ANDREGULATIONS OF THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS AND THE TEXAS DEPARTMENT OF LICENSING AND REGULATION. NO PERSON MAY MAKE MODIFICATIONS TO THIS ELECTRONICDRAWING FILE WITHOUT THE IRRIGATOR/LANDSCAPE ARCHITECT'S EXPRESS WRITTEN PERMISSION.DRAWING FILE MAY BE USED AS A BACKGROUND DRAWING. PURSUANT TO RULE 3.103(F) OF THE REGULATIONS OF THE TEXAS DEPARTMENT OF LICENSING AND REGULATION, THE USER OF THISTREE SURVEY
50'
I
N
G
R
E
S
S
&
EG
R
E
S
S
E
A
S
E
M
E
N
T
VO
L
.
9
5
2
2
5
,
P
G
.
1
7
7
2
D.
R
.
D
.
C
.
T
.
S 53°
1
9'
2
4"
W
3
2
8.
3
9'S 00°13'20" E 180.03'S 89°30'20" W 336.81'
N 03°44'55" W 24.59'N 24°11
'56
"
W48.78
'
S 69°
4
7
'
1
5
"
E
2
0
9
.
4
4
'
APPROX.
LOCATION
ZONE AE
(SFHA)
APPROX.
LOCATION
ZONE X
(NFHA)
APPROX.
LOCATION
ZONE X
(SHADED)
N 48°08'57" E 188.38'
N 43°09'22" E 33.80'
N 48°22'09" E 349.33'
100' BRAZOS ELECTRIC
POWER COOPERATIVE INC.
EASEMENT
VOL. 90122, PG. 3403
D.R.D.C.T.
20'
E
A
S
E
M
E
N
T
VO
L
.
7
9
0
7
4
,
P
G
.
4
7
D.
R
.
D
.
C
.
T
.
50'
I
N
G
R
E
S
S
&
EG
R
E
S
S
E
A
S
E
M
E
N
T
VO
L
.
9
5
2
2
5
,
P
G
.
1
7
7
2
D.
R
.
D
.
C
.
T
.
SANITARY
SEWER
MANHOLE
RIM = 483.67'
SANITARY
SEWER
MANHOLE
RIM = 478.79'
4" Cal.
(2) QUE SHU
7 gal.
(43) ILE BUR
4" Cal.
(3) QUE MUE
4" Cal.
(6) ULM CRA
4" Cal.
(4) PIS CHI
4" Cal.
QUE SHU (2)
4" Cal.
QUE VIR (2)
7 gal.
ILE BUR (80)
4" Cal.
QUE SHU (2)
4" Cal.
QUE MUE (1)
4" Cal.
ULM PAR (2)
4" Cal.
(1) QUE VIR
4" Cal.
(1) ULM PAR
4" Cal.
(2) QUE SHU
4" Cal.
QUE VIR (1)
7 gal.
ILE BUR (18)
AREA
PROVIDED
4,425 SF
10% OF ALL PAVED AREAS
43,241 SF PAVED X 10% = 4,324 SF
REQUIRED
1 TREE PER 400 SF OF REQUIRED LANDSCAPE
14 TREES4,324 SF / 400 SF = 11 TREES
PROVIDEDREQUIRED
ISLANDS GREATER THAN 12% OF PARKING SPACES
15 ISLANDS110 SPACES X 12% = 14 ISLANDS
PROVIDEDREQUIRED
1 TREE PER 50 LF, 15' ALONG STREETS, 10' ALONG PROPERTY LINES
PARKING LOT SCREENINGPARKING LOT SCREENING
PROVIDEDREQUIRED
15% OF SITE (LESS BUILDINGS) SHALL BE LANDSCAPE
25,697 SF (25%)(117,182 -13,959) X 15% = 15,483 SF
PROVIDEDREQUIRED
50% OF LANDSCAPE AREA SHALL BE IN FRONT YARD
11,485 SF (74%) 15,483 x 50% = 7,742 SF
PROVIDEDREQUIRED
1 LARGE SHADE TREE AT TERMINUS OF PARKING ROWS
15' BUFFER15' BUFFER
15' BUFFER15' BUFFER
HWY 121
COPPELL ROAD
9 EXISTING 3 NEW TREES
4 EXISTING 3 NEW TREES337 LF / 50 = 7 TREE
571 LF / 50 = 12 TREE
TRACT C
NON-VEHICULAR
OPEN SPACE
PERIMETER
LANDSCAPE
INTERIOR LANDSCAPE/
PARKING LOT
LANDSCAPE PLAN
PLANTING NOTES:
1.PLANT SIZE, TYPE, AND CONDITION SUBJECT TO APPROVAL OF OWNER'S
REPRESENTATIVE.
2.ALL PLANT MATERIAL TO BE NURSERY GROWN STOCK.
3.CONTRACTOR RESPONSIBLE FOR MAINTENANCE OF ALL PLANT MATERIAL UNTIL
PROJECT ACCEPTANCE.
4.ALL CONTAINER GROWN PLANTS TO HAVE FULL, VIGOROUS ROOT SYSTEM,
COMPLETELY ENCOMPASSING CONTAINER.
5.ALL PLANTS WELL ROUNDED AND FULLY BRANCHED. ALL TREES WITH SPREAD 2/3
OF HEIGHT.
6.CONTRACTOR TO PROVIDE OWNER WITH PREFERRED MAINTENANCE SCHEDULE OF
ALL PLANTS AND LAWNS.
7.MAINTAIN/PROTECT VISIBILITY TRIANGLE WITH PLANT MATERIAL PER CITY
STANDARDS AT ALL ENTRANCES TO SITE.
8.PREP ENTIRE WIDTH OF ALL DEFINED PLANTING BEDS WITH MIX AS OUTLINED IN
SPECS. WHERE SHRUBS ARE LOCATED ALONG CURB, SET SHRUBS BACK FROM
CURB 3 FT.
9.SEE DETAIL SHEET FOLLOWING FOR PLANTING DETAILS.
10.CONTRACTOR RESPONSIBLE FOR LOCATION OF ALL UTILITIES, INCLUDING BUT NOT
LIMITED TO TELEPHONE, TELECABLE, ELECTRIC, GAS, WATER AND SEWER. ANY
DAMAGE TO UTILITIES TO BE REPAIRED BY CONTRACTOR AT NO COST TO OWNER.
11.EXISTING TREES ARE SHOWN TO REMAIN, CONTRACTOR SHALL PRUNE ONLY ON
APPROVAL OF CITY ARBORIST. WORK TO INCLUDE REMOVAL OF ALL SUCKER
GROWTH; DEAD AND DISEASED BRANCHES AND LIMBS; VINES, BRIARS AND OTHER
INVASIVE GROWTH; AND ALL INTERFERING BRANCHES. MAKE ALL CUTS FLUSH TO
REMAINING LIMB. RETAIN NATURAL SHAPE OF PLANT. ALL WORK SUBJECT TO
APPROVAL OF OWNER'S REPRESENTATIVE.
12.QUANTITIES ARE PROVIDED AS A COURTESY AND NOT INTENDED FOR BID
PURPOSES. CONTRACTOR TO VERIFY PRIOR TO PRICING.
13.INSTALL EDGING BETWEEN LAWN AND PLANTING BEDS. REFER TO SPECIFICATIONS.
FILE ALL CORNERS SMOOTH.
14.INSTALL CURLEX BLANKET (OR EQUAL) PER MANUFACTURES INSTRUCTIONS ON ALL
GROUNDCOVER/SHRUB BEDS WITH A SLOPE OF 4:1 OR GREATER.
15.AT TIME OF PLAN PREPARATION, SEASONAL PLANT AVAILABILITY CANNOT BE
DETERMINED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO SECURE AND
RESERVE ALL B&B PLANTS WHEN AVAILABLE IN CASE ACTUAL INSTALLATION
OCCURS DURING THE OFF-SEASON. PURCHASE AND HOLD B&B PLANTS FOR LATE
SEASON INSTALLATION.
16.BERM ALL PARKING LOT ISLANDS AS SHOWN ON ENCLOSED DETAIL SHEET. (BERMS
MAY NOT BE SHOWN ON GRADING PLAN.)
17.PRIOR TO PLANTING, CONTRACTOR SHALL STAKE TREE LOCATIONS FOR APPROVAL
BY OWNER.
NOTE:
1.NO LANDSCAPE PLANTINGS WITHIN 18" OF PARKING LOT
CURBS.
2.LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR AND SHALL
MAINTAIN THE LANDSCAPING FOR 90 DAYS PAST THE FINAL
INSPECTION.
3.TEMPORARY IRRIGATION WILL BE REQUIRED TO ESTABLISH
TURF IN ALL DISTURBED AREAS WITHOUT A PERMANENT
IRRIGATION SYSTEM.
4.SOD TURF IN ALL DISTURBED AREAS AS IDENTIFIED ON
GRADING AND EROSION CONTROL PLANS.
5.ALL REQUIRED LANDSCAPE SHALL BE IRRIGATED BY AN
UNDERGROUND IRRIGATION SYSTEM WITH FREEZE AND
MOISTURE SENSORS, APPROVED BY ADMINISTRATOR.
6.ALL PLANT MATERIAL SHALL CONFORM TO THE STANDARDS OF
THE "AMERICAN STANDARD FOR NURSERY STOCK"
7.ALL REQUIRED LANDSCAPING SHALL BE MAINTAINED BY
DEVELOPER/OWNER OF THE LAND AT ALL TIMES.
REFERENCE SHEET L-4 FOR PLANT LEGEND
ONE TREE PER 2500 SF OF NON-VEHICULAR OPEN SPACE FOR AREA < 30%
7 EXISTING TREES15,483 / 2500 = 7 TREES
PROVIDEDREQUIRED
GAC
NOV 14 2022
Revisions
Drawn By
Checked By GAC
CDate
1921 MAPLEWOOD DRIVEWEATHERFORD, TX 76087 682-215-9151THIS ELECTRONIC DRAWING FILE IS RELEASED UNDER THE AUTHORITY OF GREGORY CUPPETT, LICENSEDIRRIGATOR & LANDSCAPE ARCHITECT (LICENSED IRRIGATOR NUMBER 0023539, LANDSCAPE ARCHITECT REGISTRATION NUMBER 2672) ON 11/14/22 WHO MAINTAINS THE ORIGINAL FILE. THIS ELECTRONICRULES AND REGULATIONS OF THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS AND THE RULES ANDELECTRONIC DRAWING FILE AGREES TO ASSUME ALL RESPONSIBILITY FOR ANY MODIFICATION TO ORUSE OF THIS DRAWING FILE THAT IS INCONSISTENT WITH THE REQUIREMENTS OF THE RULES ANDREGULATIONS OF THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS AND THE TEXAS DEPARTMENT OF LICENSING AND REGULATION. NO PERSON MAY MAKE MODIFICATIONS TO THIS ELECTRONICDRAWING FILE WITHOUT THE IRRIGATOR/LANDSCAPE ARCHITECT'S EXPRESS WRITTEN PERMISSION.DRAWING FILE MAY BE USED AS A BACKGROUND DRAWING. PURSUANT TO RULE 3.103(F) OF THE REGULATIONS OF THE TEXAS DEPARTMENT OF LICENSING AND REGULATION, THE USER OF THIS15' BUFFER10' BUFFER
15' BUFFER10' BUFFER
5 EXISTING 6 NEW TREES
5 EXISTING TREES209 LF / 50 = 5 TREE
508 LF / 50 = 11 TREE
RESIDENTIAL
FLOOD PLAIN
01-01
01-01
01-01
PLANTING DETAIL
TREES CODE QTY BOTANICAL NAME COMMON NAME SIZE HEIGHT SPACING REMARKS
PIS CHI 4 Pistacia chinensis Chinese Pistache 3" Cal.10` Min.Single Straight Trunk
QUE MUE 4 Quercus muehlenbergii Chinkapin Oak 3" Cal.12` Height Min Single Straight Trunk
QUE SHU 8 Quercus shumardii Shumard Oak 3" Cal.12` Height Min Single Straight Trunk
QUE VIR 4 Quercus virginiana Southern Live Oak 3" Cal.12` Height Min Single Straight Trunk
ULM CRA 6 Ulmus crassifolia Cedar Elm 3" Cal.12` Height Min Single Straight Trunk
ULM PAR 3 Ulmus parvifolia Lacebark Elm 3" Cal.12` Height Min Single Straight Trunk
SHRUBS CODE QTY BOTANICAL NAME COMMON NAME SIZE HEIGHT SPACING REMARKS
ILE BUR 141 Ilex cornuta 'Burfordii Nana'Dwarf Burford Holly 7 gal.32" - 36" Min Ht 36" O.C.
GROUND COVERS CODE QTY BOTANICAL NAME COMMON NAME SIZE HEIGHT SPACING REMARKS
CYN DAC 30,466 sf Cynodon dactylon Bermudagrass Solid Sod
LIR GIG 187 sf Liriope gigantea Giant Liriope 4" pots 12" O.C.
NAS TEN 675 Nassella tenuissima Mexican Feather Grass 4" pots 24" O.C.
TRA ASI 1,977 Trachelospermum asiaticum Asiatic Jasmine 4" pots 12" O.C.
PLANT SCHEDULE
NOTES:
1.TEMPORARY IRRIGATION WILL BE REQUIRED TO ESTABLISH TURF IN ALL OFF SITE DISTURBED AREAS
WITHOUT A PERMANENT IRRIGATION SYSTEM.
2.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CONFIRM TREE CALIPER MEASUREMENT
HEIGHTABOVE GRADE AS REQUIRED BY TOWN.
3.NO LANDSCAPE PLANTINGS WITHIN 18" OF PARKING LOT CURBS.
4.LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR AND SHALL MAINTAIN THE LANDSCAPING FOR 90 DAYS
PAST THE FINAL INSPECTION.
5.HYDRO MULCH IN ALL DISTURBED AREAS AS IDENTIFIED ON GRADING AND EROSION CONTROL PLAN.
GAC
NOV 14 2022
Revisions
Drawn By
Checked By GAC
CDate
1921 MAPLEWOOD DRIVEWEATHERFORD, TX 76087 682-215-9151THIS ELECTRONIC DRAWING FILE IS RELEASED UNDER THE AUTHORITY OF GREGORY CUPPETT, LICENSEDIRRIGATOR & LANDSCAPE ARCHITECT (LICENSED IRRIGATOR NUMBER 0023539, LANDSCAPE ARCHITECT REGISTRATION NUMBER 2672) ON 11/14/22 WHO MAINTAINS THE ORIGINAL FILE. THIS ELECTRONICRULES AND REGULATIONS OF THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS AND THE RULES ANDELECTRONIC DRAWING FILE AGREES TO ASSUME ALL RESPONSIBILITY FOR ANY MODIFICATION TO ORUSE OF THIS DRAWING FILE THAT IS INCONSISTENT WITH THE REQUIREMENTS OF THE RULES ANDREGULATIONS OF THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS AND THE TEXAS DEPARTMENT OF LICENSING AND REGULATION. NO PERSON MAY MAKE MODIFICATIONS TO THIS ELECTRONICDRAWING FILE WITHOUT THE IRRIGATOR/LANDSCAPE ARCHITECT'S EXPRESS WRITTEN PERMISSION.DRAWING FILE MAY BE USED AS A BACKGROUND DRAWING. PURSUANT TO RULE 3.103(F) OF THE REGULATIONS OF THE TEXAS DEPARTMENT OF LICENSING AND REGULATION, THE USER OF THIS
PLANTING SPECIFICATIONS
–
–
–
’
’
’
’
’
’
”
”
¾”
–
–
–
–
–
”
’
–
–
’
’
”
”
”
’
”
”
”
”
”
”
”
”
”
”
GAC
NOV 14 2022
Revisions
Drawn By
Checked By GAC
CDate
1921 MAPLEWOOD DRIVEWEATHERFORD, TX 76087 682-215-9151THIS ELECTRONIC DRAWING FILE IS RELEASED UNDER THE AUTHORITY OF GREGORY CUPPETT, LICENSEDIRRIGATOR & LANDSCAPE ARCHITECT (LICENSED IRRIGATOR NUMBER 0023539, LANDSCAPE ARCHITECT REGISTRATION NUMBER 2672) ON 11/14/22 WHO MAINTAINS THE ORIGINAL FILE. THIS ELECTRONICRULES AND REGULATIONS OF THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS AND THE RULES ANDELECTRONIC DRAWING FILE AGREES TO ASSUME ALL RESPONSIBILITY FOR ANY MODIFICATION TO ORUSE OF THIS DRAWING FILE THAT IS INCONSISTENT WITH THE REQUIREMENTS OF THE RULES ANDREGULATIONS OF THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS AND THE TEXAS DEPARTMENT OF LICENSING AND REGULATION. NO PERSON MAY MAKE MODIFICATIONS TO THIS ELECTRONICDRAWING FILE WITHOUT THE IRRIGATOR/LANDSCAPE ARCHITECT'S EXPRESS WRITTEN PERMISSION.DRAWING FILE MAY BE USED AS A BACKGROUND DRAWING. PURSUANT TO RULE 3.103(F) OF THE REGULATIONS OF THE TEXAS DEPARTMENT OF LICENSING AND REGULATION, THE USER OF THIS
TURF SPECIFICATIONS
GAC
NOV 14 2022
Revisions
Drawn By
Checked By GAC
CDate
1921 MAPLEWOOD DRIVEWEATHERFORD, TX 76087 682-215-9151THIS ELECTRONIC DRAWING FILE IS RELEASED UNDER THE AUTHORITY OF GREGORY CUPPETT, LICENSEDIRRIGATOR & LANDSCAPE ARCHITECT (LICENSED IRRIGATOR NUMBER 0023539, LANDSCAPE ARCHITECT REGISTRATION NUMBER 2672) ON 11/14/22 WHO MAINTAINS THE ORIGINAL FILE. THIS ELECTRONICRULES AND REGULATIONS OF THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS AND THE RULES ANDELECTRONIC DRAWING FILE AGREES TO ASSUME ALL RESPONSIBILITY FOR ANY MODIFICATION TO ORUSE OF THIS DRAWING FILE THAT IS INCONSISTENT WITH THE REQUIREMENTS OF THE RULES ANDREGULATIONS OF THE TEXAS BOARD OF ARCHITECTURAL EXAMINERS AND THE TEXAS DEPARTMENT OF LICENSING AND REGULATION. NO PERSON MAY MAKE MODIFICATIONS TO THIS ELECTRONICDRAWING FILE WITHOUT THE IRRIGATOR/LANDSCAPE ARCHITECT'S EXPRESS WRITTEN PERMISSION.DRAWING FILE MAY BE USED AS A BACKGROUND DRAWING. PURSUANT TO RULE 3.103(F) OF THE REGULATIONS OF THE TEXAS DEPARTMENT OF LICENSING AND REGULATION, THE USER OF THIS