Trash Enclosure_v1A005
A005
A0053A005
7
5
10
28' - 0"
4' - 0"4' - 0"1' - 0"26' - 0 3/4"
8X8X16 CMU BLOCKS
#5 RE-BAR AT 32" O.C. MIN. VERTICAL REINFORCING
FILL CELLS SOLID WITH GROUT
HORIZONTAL TRUSS TYPE REINFORCING @ 16" O.C. MIN.
BY HOHMANN & BARNARD WWW.H-B.COM OR EQUAL
6" DIA. STEEL PIPE
CONCRETE FILLED
BOLLARDS
MIN. CLEAR OPENING
11' - 6"
11 5/8"
11 5/8"11 5/8"12' - 0 3/8"13' - 0"A005
8
9
6" ⌀PIPE
HINGECANE
BOLT
DROP
ROD
LOCKING
PIN
ANCHOR
HOLE
11
A005
SLOPE CONC.0.5%-1.0%2' - 6"2' - 0"2' - 6"2' - 0"MIN. CLEAR OPENING
11' - 6"
4' - 0"4' - 0"
BRICK
FINISH
Top of Slab
0' -0"
Top of Wall
7' -6"
Foundation
-2' -6"
CANE BOLT
DROP ROD
3/4" ⌀
30" LONG
6" INTO
CONCRETE
1" ⌀HOLE
HINGE
6" STEEL PIPE
GATE PULL
4
A005
6' - 0 1/2"6' - 0 1/2"7' - 6"Top of Slab
0' -0"
Top of Wall
7' -6"
Foundation
-2' -6"
Top of Slab
0' -0"
Top of Wall
7' -6"
Foundation
-2' -6"
8x8x16
SPLIT FACE CMU
Top of Slab
0' -0"
Top of Wall
7' -6"
Foundation
-2' -6"
BRICK OVER CMU
BR-1
Top of Slab
0' -0"
Top of Wall
7' -6"
3"x2" TUBE STEEL FRAME
WITH 3x3 ANGLE
4
A005
1" METAL DECK
Top of Slab
0' -0"
Top of Wall
7' -6"5' - 0"A005
12
6" DIA. STEEL PIPE
CONCRETE FILLED
BOLLARDS
CMU BOND BEAM
8X8X16
CMU BLOCKS
#5 RE-BAR AT
32" O.C. MIN.
VERTICAL
REINFORCING
FILL CELLS
SOLID WITH GROUT
HORIZONTAL TRUSS
TYPE REINFORCING
@ 16" O.C. MIN.
BY HOHMANN &
BARNARD
WWW.H-B.COM
OR EQUAL
7'-4" TOP OF CMU
BOND BEAM
FOUNDATION PER
STRUCTURAL DRAWINGS
6" THICK
REINFORCED CONCRETE SLAB
W/ #4 RE-BARS @ 16" O.C. EA. WAY
EPOXY PAINT OVER CMU AT INTERIOR
2" THICK CONCRETE CAP
BLOCK
2 in. x 8 in. x 16 in.
SET IN MORTAR BED
CONCRETE
LEDGE FOR
BRICK
#5 X 5'-0" DOWELS @ 24" O.C.2"1' - 0"7' - 4"MODULAR BRICK
FINIISH
6" DIA. STEEL PIPE
CONCRETE FILLED
BOLLARD
PAINT SAFETY
YELLOW
CONCRETE
ROUNDED TOP
24" DIA. CONCRETE FOOTING
REINFORCING PER STRUCTURAL
ENGINEER
1/2" EXPANSION JOINT
CONCRETE PAVING
RE-BAR
WELDED TO PIPE4'-0" AT OVERHEAD DOORS5'-0" AT TRASH ENCLOSUREPER STRUCTURAL1" THICK METAL DECK WELDED
TO STEEL FRAME
PAINTED FINISH
3x2" TUBE
STEEL FRAME
3 X 3 STEEL
ANGLE
INSIDE
OUTSIDE
3"
Scale
Project number:
Date:
Drawn by:
Checked by:
THIS DOCUMENT MAY
NOT
BE USED FOR
CONSTRUCTION,
PERMITING, OR
REGULATORY
APPROVAL
NOT FOR
CONSTRUCTION
Seal:
Architect:
Greg Guerin Architect
TX License # 22011
EAST STAR DESIGN
P.O. BOX 53
FORNEY, TX 75126 USA
(972) 200-7340
Architect@
EastStarDesign.com
TX Firm # BR 1785
Revisions:
OFFICE & RETAIL
DEVELOPMENT
LEGAL DESCRIPTION
B B B & C RR ABST 1772
PG 430
TR 5 ACS 2.464
DALLAS CAD
#65177243010050000
DATE: NOVEMBER 2022
OWNER:
AVATAR REALTY GROUP LLC
906 BOXWOOD DR
LEWISVILLE, TEXAS 75067
RAO KARUSALA
RAO@TECHORBIT.COM
VIJAY KLOSER
STP.KLOSER@GMAIL.COM
ARCHITECT:
GREG GUERIN, NCARB
EAST STAR DESIGN
P.O. BOX 53
FORNEY, TX 75126
(972) 200-7340
gguerin@EastStarDesign.com
ENGINEER:
THOMAS
SITE DEVELOPMENT
ENGINEERING, INC.
TBPE REG. NO. F-10289
MATHEW THOMAS P.E.
P.O. BOX 1261
COLLEYVILLE, TX 76034
(214) 680-2728
mathew@thomas-eng.com
LANDSCAPE ARCHITECT:
FAIN CUPPETT
LANDSCAPE
ARCHITECTS, LLC
GREG CUPPETT, ASLA,
PLA, CLARB
1921 MAPLEWOOD DR
WEATHERFORD, TX 76087
C 682-215-9151
gcuppett@faincuppett.com
SURVEYOR:
TEXAS HERITAGE
Firm No. 1016930
DOUG R. STEWART
10610 METRIC DRIVE,
SUITE 124
DALLAS, TEXAS 75243
214-340-9700
Doug@txheritage.com
11/14/2022 11:13:36
AM
As indicated11/14/2022 11:13:36 AM Z:\OneDrive - East Star Design\Revit Active Projects\22027-Coppell Office and Retail\22027-Trash Enclosure Double (v23).rvtA005
Trash Enclosure -
Double
22-002
OFFICE & RETAIL
DEVELOPMENT
GG
-
1730 State Hwy 121
Coppell, TX 75019
1/4" = 1'-0"6 Floor Plan
1/4" = 1'-0"7 Front Elevation
1/4" = 1'-0"10 Left Elevation 1/4" = 1'-0"3 Right Elevation
1/4" = 1'-0"5 Rear Elevation1/4" = 1'-0"9 Interior Front Elevation
1/4" = 1'-0"8 Interior Rear Elevation
1 Axonometric - Front Left
2 Axonometric - Rear Right
3/4" = 1'-0"11 Refuse Enclosure Section
3/4" = 1'-0"12 Bollard
1 1/2" = 1'-0"4 Trash Enclosure-Gate Detail Plan
No. Description Date