Utility Plan_v1g
d
J
H
O
U
W
2
(n
Z
U
V)
0
U
W
O
0-
W
U
L�
L.�
O
J
o_
0
U
N
CD
N
0
0
Y
Of
0
M
U
W
W
ZM
O
cD
='6
tR
N
N
1n O
� N
W \
(N
U
UTILITY MATERIAL SPECIFICATIONS
DESCRIPTION
SPECIFICATION
6" WATER LINE AND LARGER
AWWA C900
3" WATER LINE AND SMALLER
AWWA C901 & ASTM F714 PE PIPE
GAS LINES
ASTM D-2513 DIRECT BURIAL PE PIPE
SANITARY SEWER (4" TO 15")
1 SDR35 MEETING ASTM D3034
0 30 60 90 120
GRAPHIC SCALE IN FEET
I " = 30'
PROPERTY LINE
— —
ADJOINED PROPERTY
BUILDING SETBACK LINE
EXISTING EASEMENTS
— PROPOSED EASEMENTS
—
EXISTING CURB
PROPOSED CURB
AND GUTTER
•
PROPOSED SAN. SEWER CLEANOUT
T
PROPOSED GATE VALVE
w
PROPOSED PRIVATE WATER LINE
w
SS
PROPOSED 4" PRIVATE SAN. SEWER LINE
SS
Gw
PROPOSED GREASE WASTE LINE
Gw
GAS
PROPOSED GAS LINE
GAS
UGE
PROPOSED UNDERGROUND ELECTRICAL LINE
UGE
coM
coM
PROPOSED COMMUNICATIONS LINE
QTATG (1G TPYAQ
/�LEC.
5ti� � xmussw r:w.0
1
yta II TRANS. /4
18" RCP
5
SS /
Q
10
00
st� °1e' y1 18" ,
s 1/2" IR / � / <CM> 2� AK /
/z o 6•' OAK
1/2"
/ z i z'`1�K 9�e
SIGN °tee / T •
—r/ m
• • 14" OAK 12" OA "
3 22" OAK • �"'�
"X" FND.
/sr SI N °
S INSTALL FIRE N. COPPELL ROAD HYDRANT PER
12" WATER
LINE (60' RIGHT-OF-WAY) STD. DETAIL 4120
°� 3 12" WATER
LINE
/ (_w w-Fw w w w w w w w w A w w w w w w w w w w w w w w w w w w w w w
ode WV
GENERAL NOTES:
9. ALL PAVEMENT DIMENSIONS ARE TO FACE OF CURB UNLESS INDICATED OTHERWISE. ALL
BUILDING DIMENSIONS ARE TO OUTSIDE FACE OF WALL UNLESS INDICATED OTHERWISE.
2. SEEARCHITECTURAL SHEETS FOR EXACT DIMENSIONS OF BUILDING, AND DETAILS
AROUND THE BUILDING.
3. ALL CURVE RADII ARE 3' UNLESS NOTED OTHERWISE.
4. SEE ELECTRICAL PLANS FOR SITE LIGHTING DESIGN AND DETAILS.
100' BRAZOS ELECTRIC
POWER COOPERATIVE INC.
EASEMENT
VOL. 90122, PG. 3403
D.R.D.C.T.
N. COPPELL ROAD
(60' RIGHT-OF-WAY)
e
POINT OF
BEGINNING /�/ °�e
/ SS
OHP OHP Ofip' OHP OHP OHP OHP —
e'��' °fie I
I 1/ "IRFYC
"BRITTN/CRAWFORD" *41111.
So
6" ELM1j2 j0,
TXDOT / / 12" ELnd`
Y° FIND12" ELM 0 DBI
10" E TRIPLE 6" HACK
10"^LM \ ` / 6" HACK \ 8„
e / LM— — {
g' M
O ELM 8;ELM
14" ELM 8 ELM 0" BOIS D'ARC 8" ELM 6" ELM
a I 1�-. 10" ELL \
II
1/2" IRF OC
"PIBURN PARTNERS"
LOT
<CM>
\
2X
1/2" IRE BRICK
<CM> RET. WALL
STONE
RET. WALL
w w w w w w w w w w w w w w w w w w w w
JOHN EGELSTON, REBECCA EGELSTON CASO,
SARA EGELSTON AKERS, IRENE WHALEY,
WYNELLE WHALEY, JOHN W. WHALEY,
AND FRANCES WHALEY CARLEY
VOL. 200531, PG. 8619
D.R.D.C.T.
111111, � �6
LF 8"E
12" ELlvl� 6" ELM
APPROX.
LOCATION_
ZONE AE
(SFHA) —
10" E
�DBL�BOIS ` 8" EL
8" PECAN dBL 6" BOIS D'ARC \
NLE 10"Lt4<
6" PECAN 12" ELM APPRO'�_ �
ER STUB �\/\ LOCATION
L $ ✓— 8'*&3.50t ZONE X /
•
8" ELII -..n
POST FOR
WATER
LOCATION) 12 ELM (SHADED) o
r \ i
1/2" IRF •�
" ELM
6" HACK APT
10
J EYIN ' LOT
' - 6" ELM
6" El,pt' r 3X
INSTALL 4' DIA. SAN. SEWER �\
MANHOLE. s
FL IN 6" = 464.20 LL
FL OUT 8 464.00 t$ / Sz 2p'F
7 00'C S 0�,
8�, %NSF
iLM 9\� SANITARY \ 4,
K 10"COTTONW004 / 6g�yy SEWER
NHOLE
0" EL 11�+°j�LEERG`I �z RI 478.79'
�dyy
J/ S �� LO
HACK y" 20 CONNECT 8" WASTE(,
;�// � LINE TO EXISTING 8",
55� s„� / WILLOW PARK
PS
ty �NOCLEANOUT INST. NO. 201100027028 OR MANHOLE O.P.R.D.C.T.
Zt� HERE
I
ICV LOT
zt WM
•
8" SAN. 19
3 \ f SEWER LINE
s
DA VINCII COURT
(50' RIGHT-PF-WAY)
3
3
i
_ I
WILLOW PARK
INST. NO. 201100027028
O.P.R.D.C.T.
TH
SI E
T PA e�V\��Qat�
off �
PG0�`
W MISTY HAVEN
0
Y
�r o
OAK GROVE
\ 10P
FG so',
< 9 F'�hs VICINITY MAP (1 " = 2000 )
0 2s FM
.ROOT ��2T
GENERAL NOTES
Z)
m
1. ALL UNDERGROUND UTILITIES SHOWN ARE BASED ON THE BEST
AVAILABLE INFORMATION. THE CONTRACTOR SHALL VERIFY EXACT
UTILITY LOCATIONS PRIOR TO ANY CONSTRUCTION. THE CONTRACTOR
SHALL CALL DIG- TESS AT 1.800.344.8377 PRIOR TO ANY EXCAVATION.
2. IF ANY CONFLICT OR DISCREPANCY FROM THE PLANS IS FOUND,
NOTIFY THE ENGINEER BEFORE CONTINUING WITH ANY FURTHER
CONSTRUCTION.
3. ALL PIPE SHALL BE LAID STARTING AT THE PUBLIC TIE-IN LOCATION
AND LAID UPSTREAM FROM THAT POINT.
4. ALL SANITARY SEWER AND WATER PIPE AND APPURTENANCES SHALL
MEET ASTM AND CITY OF COPPELL STANDARDS FOR UTILITY
CONSTRUCTION.
5. SEE GENERAL NOTES SHEET C-0.3 FOR ADDITIONAL INFORMATION.
6. FOR IRRIGATION AND ELECTRICAL SLEEVE LOCATIONS REFER TO THE
IRRIGATION AND ELECTRICAL PLANS.
TRENCH SAFETY.
STATE OF TEXAS LAW REQUIRES THAT THE CONTRACTOR WILL
PROVIDE TRENCH SAFETY PLAN (TRENCH SHORING) FOR UTILITY
TRENCHES GREATER THAN FIVE (5) FEET IN DEPTH. THIS PLAN SHALL
BE PREPARED BYA PROFESSIONAL ENGINEER. THE CONTRACTOR
SHALL SUBMIT THE TRENCH SAFETY PLAN TO THE CITY ENGINEER
PRIOR TO THE START OF CONSTRUCTION.
UTILITY PLAN
LOT 1, BLOCKA
117,511 SF (2.70 Ac.)
PROPOSED 121 A VA TAR SUBDIVISION
BBB & CRR SURVEY, ABSTRACT NO.1772
CITY OF COPPELL, DALLAS COUNTY, TEXAS
DEVELOPER ENGINEER
AVATAR REALTY GROUP LLC THOMAS SITE DEVELOPMENT ENGINEERING INC.
906 BOXWOOD DR LEWISVILLE, TEXAS 75067 P.O. BOX 1261, COLLEYVILLE, TX 76034
RAO KARUSALA RAO@TECHORBIT.COM ATTN: MA THEW THOMAS, PE
VIJAYKLOSER S TP. KL OSER@GMA IL. COM PH: (214) 680-2728
Z
W
W
W W o
Z
Z O
y W �wU
� J Q uj
J
uj
J
J 1
O � W
m0Q
Lu O =
LV
THIS DOCUMENT IS RELEASED
FOR THE PURPOSE OF INTERI
REVIEW UNDER THE
AUTHORITYOF:
MA THEW THOMAS, P.E.
LICENSED ENGINEER # 81576
11 NOV 2022
NOT FOR REGULATORY
APPROVAL, PERMITTING OR
L CONSTRUCTION
LQ
O
WQ�
O �
O
O
W �
J � w
\ a J
Q � W
\_ O
N
O
Z
0
I—
U
N
w
0
Cw4mO