Loading...
DA01328A_A_and_E_CDs_Final_TMO_Anchor_Rev0_10.11.2022_v1.ADM APP.12082022T-MOBILE SITE NUMBER: T-MOBILE SITE NAME: SITE TYPE: TOWER HEIGHT: DA01328A CROWN #876558 MONOPOLE 711-611 lUlo�ilP� BUSINESS UNIT #: SITE ADDRESS: COUNTY: JURISDICTION: T-MOBILE ANCHOR SITE CONFIGURATION: 56761EK SR SITE INFORMATION CROWN CASTLE USA INC. F3 - COPPELL MIDDLE S SITE NAME: SITE ADDRESS: 1301 WRANGLER COPPELL, TX 75019 COUNTY: DALLAS MAP/PARCEL #: 65005640510070000 AREA OF CONSTRUCTION: EXISTING LATITUDE: 32.93485000° LONGITUDE: -97.00155000' LAT/LONG TYPE: NAD83 GROUND ELEVATION: 526.5 FT CURRENT ZONING: LIGHT INDUSTRIAL JURISDICTION: CITY OF COPPELL OCCUPANCY CLASSIFICATION: U TYPE OF CONSTRUCTION: IIB A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION PROPERTY OWNER: COPPELL I S D 200 S DENTON TAP RD COPPELL, TX 75019-3205 TOWER OWNER: CROWN CASTLE USA, INC. 2 CHASE CORPORATE DRIVE, SUITE 105 BIRMINGI IAM, AL 35244 ELECTRIC PROVIDER: ONCOR 888-313-4747 TELCO PROVIDER AT&T 800-288-2020 PROJECT TEAM A&E FIRM: P. MARSHALL & ASSOCIATES, LLC. 6801 PORTWEST DR. - SUITE 100 HOUSTON, TX 77024 SENIOR ENGINEER - PATRICK W. MARSHALL, P.E. PROJECT ENGINEER - SAM ELLIS 713-677-0964 CARRIER/APPLICANT: T-MOBILE 7668 WARREN PARKWAY FRISCO, TX 75034 SHAMROSE ALI - PROJECT MANAGER 505-250-7489 CROWN CASTLE 1220 AUGUSTA DRIVE, SUITE 500 USA INC. DISTRICT HOUSTON, TX 77057 CONTACTS: BRIAN SEBASTIAN - PROJECT MANAGER 904-624-0745 JOE MCCALL - CONSTRUCTION MANAGER DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET GN-1 GENERAL NOTES C-1 OVERALL SITE PLAN C-2.I ENLARGED SITE PLAN (EXISTING) C-2.2 ENLARGED SITE PLAN (PROPOSED) C-3 FINAL ELEVATION & ANTENNA PLANS C-4 ANTENNA & CABLE SCHEDULE C-5 RF DESIGN SHEET C-6 PLUMBING DIAGRAM C-7 EQUIPMENT SPECS C-7.1 EQUIPMENT SPECS G-1 GROUNDING SITE PLAN G-2 GROUNDING DETAILS G-3 GROUNDING DETAILS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11' X 17'. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. f PROJECT SCOPE 1 FINAL TOWER CONFIG: • (12) ANTENNAS • (9) RRUs • (3) TMAs • (3) HCS 2.0 J-BOXES • (3) 1-1/2" HCS 2.0 CABLES • (6) 7/8" COAX LINES • (1) ANTENNA PLATFORM MOUNT FINAL GROUND CONFIG: • (1) HPL3 CABINET • (1) LB3 CABINET • (3) HCS 2.0 J-BOXES • (1) AMIA ELECTRICAL NOTE: NO NEW AC ELECTRICAL WORK IS CAPTURED WITHIN THIS PROJECT SCOPE. ALL ELECTRICAL UPGRADES AND OR WORK WILL BE HANDLED BY THE GENERAL CONTRACTOR AND PERFORMED IN ACCORDANCE WITH THE LOCAL JURISDICTIONAL REQUIREMENTS. EMERGENCY NOTE: NO EQUIPMENT PROPOSED WITHIN THE PROJECT SCOPE SHALL BE USED FOR EMERGENCY RESPONSE. NOTE: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER 876558 PLANNING AOMINISTRATIVE APPROVAL COPPELL 12/08/2022 1301 WRANGLER,COPPELL, TX 75019 DALLAS CITY OF COPPELL LOCATION MAP O ar Rodeo Goat } o Cypress Waters!' jf •� 12T SIIEID: DA01328A QuiiCTfip LAT: 32.93485000" O G LONG:-97.00155000, / a Texas Roadhouse {keld Dallas/Fort Worth �..- .. Airport Marriott„(p Hello, lridia- gr�^~�WFtayal. NO SCALE APPLICABLE CODES/REFERENCE DOCUMENTS ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING 2015IBC MECHANICAL 2015IMC ELECTRICAL 2014 NEC REFERENCE DOCUMENTS: STRUCTURAL ANALYSIS: MORRISON HERSHFIELD DATED: 10/18/2022 MOUNT ANALYSIS: BY OTHERS DATED: RFDS REVISION: 30 DATED: 10/26/2022 ORDER ID: 622870 REVISION: 0 ©CALL TEXAS ONE CALL p (L3 DIG-TESS p CALL 3 WORHING DAYS �asv BEFORE YOU DIGI VALLEY RANCH 07 tr a RancO<t 11 Sams Club data 420221 APPROVALS APPROVAL SIGNATURE DATE PROPERTY OWNER OR REP. LAND USE PLANNER T-MOBILE OPERATIONS RF NETWORK BACKHAUL CONSTRUCTION MANAGER AN 0 Nd WON rs "bj i ME 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HWY 161, SUITE 200 IRVING, TX 75038 p� P. MARSHALL & ASSOCIATES 6801 PORTWEST DR- STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA A 08/16/2022 EAK PRELIM SBE 0 11/11/2022 EAK FINAL SBE OF 7, rah PATRICK W MARSHALL ....:................................... 86101 1, %.20NAL FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. NUMBER f--77&A 22CT2M-132 SHEET NUMBER: REVISION: T-1 o CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS: GENERAL NOTES: ELECTRICAL INSTALLATION NOTES: 1. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE TO PROCEED (NTP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN CASTLE USA INC. NOC AT 800-788-7011 & THE CROWN CASTLE USA INC. CONSTRUCTION MANAGER. 2. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL REQUIREMENTS. 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND CROWN CASTLE USA INC. STANDARD CED-STD-10253, INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION TO CERTIFY THE SUPPORTING STRUCTURES IN ACCORDANCE WITH ANSI TIA-322 LATEST EDITION . 11 ( ) 5. ALL SITE WORK TO COMPLY WITH GAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWN CASTLE USA INC. TOWER SITE" AND LATEST VERSION OF ANSI TIA-1019-A-2012 "STANDARD FOR INSTALLATION ALTERATION AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS:' 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY PROCEDURES. 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATEST APPROVED REVISION. 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, TOWER OWNER, CROWN CASTLE USA INC., AND/OR LOCAL UTILITIES. 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. I. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER: T-MOBILE TOWER OWNER: CROWN CASTLE USA INC. 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY. 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 6. PRIOR TO THE SUBMISSION OF BIDS THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CROWN CASTLE. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC. 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. CONCRETE, FOUNDATIONS, AND REINFORCING STEEL: 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST -IN -PLACE CONCRETE. 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 psf. 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (fc) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90°f AT TIME OF PLACEMENT. 4. CONCRETE EXPOSED TO FREEZE -THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR ENTRAINMENT TO BE BASED ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A MAXIMUM WATER -TO -CEMENT RATIO (W/C) OF 0.45. 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC(WWF) SHALL CONFORM TO ASTM A185. ALL SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, UNLESS NOTED OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: #4 BARS AND SMALLER 40 ksi #5 BARS AND LARGER 60 ksi 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" CONCRETE EXPOSED TO EARTH OR WEATHER: #6 BARS AND LARGER 2" #5 BARS AND SMALLER- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-T/2"- - - CONCRETE NOT EXPOSED TO EARTH OR WEATHER- - - - - - - - - - - - - - - - - - - - - - - - - - SLAB AND WALLS 3/4" BEAMS AND COLUMNS 1-1/2" 7. A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. GREENFIELD GROUNDING NOTES: 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 2. THE CONTRACTOR SHALL PERFORM IEEE FALL -OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH 46 COPPER WIRE ULAPPROVED GROUNDING TYPE CONDUIT CLAMPS. S. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARESOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 900 BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45° BENDS CAN BE ADEQUATELY SUPPORTED. 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6 It OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR SUCH AS METALLIC CONDUITS MErALSUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD -WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). I. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS NEC AND ALL APPLICABLE FEDERAL STATE AND LOCAL CODES/ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE IBM BRAND 1 2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S). 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 8. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR 1#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR, TYPE SCOW CORD 1#14 OR LARGER) UNLESS OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR TYPE TC CABLE #14 OR LARGER WITH TYPE THHW THWN THWN-2 XHHW XHHW-2 THW THW-2 RHW OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETT$ OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75° C (90- C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT. 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SETSCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE NEC. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i.e. POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW'T-MOBILE'. 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. CONDUCTOR COLOR CODE SYSTEM CONDUCTOR COLOR 120/240V, 10 A PHASE BLACK B PHASE RED NEUTRAL WHITE GROUND GREEN 120/208V, 30 A PHASE BLACK B PHASE RED C PHASE BLUE NEUTRAL WHITE GROUND GREEN 277/480V, 30 A PHASE BROWN B PHASE ORANGE OR PURPLE C PHASE YELLOW NEUTRAL GREY GROUND GREEN DC VOLTAGE POS (+) RED** NEG (-) BLACK** - Nei. Z I Ua1�11 I) ANU 1Z1 POLARITY MARKED AT TERMINATION ABBREVIATIONS: ANT ANTENNA (E) EXISTING FIF FACILITY INTERFACE FRAME GEN GENERATOR GPS GLOBAL POSITIONING SYSTEM GSM GLOBAL SYSTEM FOR MOBILE HE LONGTERM EVOLUTION MGB MASTER GROUND BAR MW MICROWAVE (N NEW NEC NATIONAL ELECTRIC CODE (P) PROPOSED PP POWER PLANT QTY QUANTITY RECT RECTIFIER RBS RADIO BASE STATION RET REMOTE ELECTRIC TILT RFDS RADIO FREQUENCY DATA SHEET RRH REMOTE RADIO HEAD RRU REMOTE RADIO UNIT SIAD SMART INTEGRATED DEVICE TMA TOWER MOUNTED AMPLIFIER TYP TYPICAL UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM W.P. WORK POINT APWA UNIFORM COLOR CODE: WHITE PROPOSED EXCAVATION ® TEMPORARY SURVEY MARKINGS ELECTRIC POWER LINES, CABLES, CONDUIT, AND LIGHTING CABLES YELLOW GAS, OIL, STEAM, PETROLEUM, OR GASEOUS ATERIALS COMMUNICATION, ALARM OR SIGNAL LINES, CABLES, OR CONDUIT AND TRAFFIC LOOPS ® POTABLE WATER RECLAIMED WATER, IRRIGATION, AND SLURRY LINES ® SEWERS AND DRAIN LINES Pu ADMINISTRATIVE APPROVAL COPPE L / 12/08/2022 ON 0 Me rs "bj i WIM 7668 WARREN PARKWAY FRISCO, TX 75034 CROWN CASTLE v 6191 N STATE HWY 161, SUITE 200 IRVING, TX 75038 Nmo P. MARSHALL & ASSOCIATES 6801 PORTWEST DR_ STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 08/16/2022 EAK PRELIM SBE 0 11/11/2022 EAK FINAL SBE OF 7, �s1kit1 �17� ; � •• 7C11 PATRICK W MARSHAL_L 86101 III,�,SCENS.•�G-�� FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A NUMBER: 22CT2M-132 SHEET NUMBER: REVISION: GN-11 0 SITE PLAN DISCLAIMER: PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROM PREVIOUS PLAN SETS OR FROM ASSESSORS MAPS. PM&A HAS NOT COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIMS AS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET. CONTRACTOR SHALL FIELD VERIFY SITE PLAN & EQUIPMENT SHOWN AGAINST PRESENT FIELD CONDITIONS. IF PLANS DO NOT MATCH UP WITH SITE CONDITION AT TIME OF CONSTRUCTION, CONTACT T-MOBILE AND THE CROWN CASTLE CM. F x x x x (E) UTILIT` FRAME (TYP. x x x x +59'-5.. X x (E) GATE (TYP.) X x X (E) CROWN CASTLE COMPOUND x (E) FIBER MARKER x (E) CHAIN -LINK FENCE (TYP.) x ----Ih x u ul fLL - (E) T-MOBILE 10'-11'. x 16'-0" EQUIPMENT PLATFORM x x x k_� x X X x x +16' 0" COVERALL SITE PLAN ( SCALE: 319-1'-0"(FULL SIZE) N 2' 1' 0 2' 3/16"-1'-U'H 1.17) PLANNING ADMINISTRATIVE APPROVAL COPPELL 12/08/2022 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HWY 161, SUITE 200 IRVING, TX 75038 p ° P. MARSHALL & ASSOCIATES 6801 PORTWEST DR STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 08/16/2022 EAK PRELIM SBE 0 11/11/2022 EAK FINAL SBE �- P�� o F • re��S ���1 . ....................................... PATRICK W MARSHAL_L ........................................ 86101 . ICE N FS � FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A NUMBER: 22CT2M-132 SHEET NUMBER: REVISION: c - 1 10 SITE PLAN DISCLAIMER: PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROM PREVIOUS PLAN SETS OR FROM ASSESSORS MAPS. PM&A HAS NOT COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIMS AS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET. CONTRACTOR SHALL FIELD VERIFY SITE PLAN & EQUIPMENT SHOWN AGAINST PRESENT FIELD CONDITIONS. IF PLANS DO NOT MATCH UP WITH SITE CONDITION AT TIME OF CONSTRUCTION, CONTACT T-MOBILE AND THE CROWN CASTLE CM. (E) T-MOBILE FEEDLINES TO BE REMOVED: (6) 7/8" COAX CABLES (E) T-MOBILE FEEDLINES TO REMAIN: (6) 7/8" COAX CABLES (E) 71 6" MONOPOLE TOWER (E) T-MOBILE 200A METER (E) T-MOBILE (6) DIPLEXERS (MOUNTED BELOW ICE BRIDGE) TO BE REMOVED _L (E)T-MOBILE FLOOD LIGHT / (E) T-MOBILE TW CABINET (E) T-MOBILE TO REMAIN DISCONNECT (E) T-MOBILE / FCOA CABINET / TO BE REMOVED ' I I I � �I — — — — — — — — — —ly— i UTILITY X UTILITY POST (E) T-MOBILE PPC & TELCO CABINET ON 0 Me rs "bj i WON 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HWY 161, SUITE 200 IRVING, TX 75038 p ° 0 P. MARSHALL & ASSOCIATES 6801 PORTWEST DR- STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T-MOBILE SITE NUMBER: DA01328A ------- BU #: 876558 i F3 - COPPELL MIDDLE S 1301 WRANGLER \\ \\\\ \\ \\ COPPELL, TX 75019 \\ \ \ \ \ (E) T-MOBILE 10'-11"x 16'-0" \\ \\ \\ EQUIPMENTPLATFORM - \ \ W/ ENNT (E) EQUIPMENT - EXISTING 71'-6" MONOPOLE 1=====_____ — - - - - - - - - - - ) Li —� (E)T-MOBILE (El HYBRID (2J 1-1/4"NSN HIGH CAP CABLES TO BE REMOVED ° o ------------ t— I CIENA I I I _ (E) T-MOBILE (2) COVP ISSUED FOR: (E) T-MOBILE TO BE REMOVED SSC CABINET (E) T-MOBILE REV DATE DRWN DESCRIPTION DES./Q TO BE REMOVED FCOA CABINET TO BE REMOVED A 08/16/2022 FAK PRELIM SBE 0 11/11/2022 EAK FINAL SBE (E) T-MOBILE GPS ANTENNA (TYP.) o L o — J ' (E) T-MOBILE UTILITY FRAME ------------J -\�---------� (E)T-MOBILE ICE BRIDGE (TYP.) (E) CARRIER ICE BRIDGE (TYP.) (E) TOWER END PAD (E) T-MOBILE ICE BRIDGE POST (TYP.) ENLARGED SITE PLAN (EXISTING) (SCALE: 1"=r-o(Fusae� 0 ' 11T-1'-0(IW7) N PLANNING ADMINISTRATIVE APPROVAL COPPELL 12/08/2022 �- P�� OF . ... PATRICK W MARSHAL_L ........................................ ,IIII�. 86101 FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A NUMBER: 22CT2M-132 SHEET NUMBER: REVISION: C- 2.1 0 SITE PLAN DISCLAIMER: PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROM PREVIOUS PLAN SETS OR FROM ASSESSORS MAPS. PM&A HAS NOT COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIMS AS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET. CONTRACTOR SHALL FIELD VERIFY SITE PLAN & EQUIPMENT SHOWN AGAINST PRESENT FIELD CONDITIONS. IF PLANS DO NOT MATCH UP WITH SITE CONDITION AT TIME OF CONSTRUCTION, CONTACT T-MOBILE AND THE CROWN CASTLE CM. (ROUTE ALL (P) CONDUITS ALONG BOTFOM OF EQUIPMENT PLATFORM WITH UNISTRUT & CONDUIT STRAPS (P) (3) 1-1/2" NOKIA 2.0 HYBRII W/ BREAKOUT FEATURE ROUTEI J-BOX TO TOWER ALONG ICE (±125' CABLE I (E) T-MOBILE FEI (6) 7/8" COAX ICE BRIDGE (TYP.) ENLARGED SITE PLAN (PROPOSED) I / SCALE: I"=I'-o (FULL SIZE) N KEY NOTES: CO PROPOSED 2' x 10" CHASE NIPPLES FINAL RAN SECTION (HP LARGE 3): EXISTING/PROPOSED: • (2) PSU 4813 • (I) AMIA UNIT: •• (2J ASIL UNITS •• (IJ ABTA UNIT FOR L2100, L1900 •• (2) ABIO UNITS FOR L2100, L1900, N 1900 (DARK), N2100 (DARK) •• (I) ABIO UNIT FOR L2500 •• (I) ABIO UNIT FOR N2500 •• (1) ABIO UNIT FOR N600, L600, L700 AMIA AIRSCALE SUBRACK HOUSES UP TO (2) ASIA UNITS & (6) ABIA UNITS. PLANNING AOMINISTRATIYE APPROVAL COPPELL 12/08/2022 7668 WARREN PARKWAY FRISCO, TX 75034 CROWN v CASTLE 6191 N STATE HWY 161, SUITE 200 IRVING, TX 75038 [pVm P. MARSHALL & ASSOCIATES 6801 PORTWEST DR- STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 08/16/2022 EAK PRELIM SBE 0 11/11/2022 EAK FINAL SBE OF reds kit 1 PATRICK W MARSHAL_L ........................................ ,IIII�. 86101 F 1� �S�ONAL FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A I.ICENSI D PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A NUMBER: 22CT2M-132 SHEET NUMBER: REVISION: C-2.2 0 NOTE: DIRECT TOWER MOUNTED EQUIPMENT MUST NOT TRAP OR INTERFERE WITH CLIMBING PEGS/STEPS AND SAFETY CLIMB. DO NOT OBSTRUCT BEACON IF TOWER LIT. T-MOBILE EQUIPMENT ANTENNA CL: 75' MOUNT CL: 73' (ANY AND ALL TOWER MOUNTED EQUIPMENT MUST NOT TRAP OR INTERFERE W/ EXISTING SAFETY CLIMB 1 FINAL ELEVATION SCALE: NOT TO SCALE (P) T-MOBILE EQUIPMENT (6) ANTENNAS (9) RRUs (3) HCS 2.0 HYBRID TRUNK W/ BREAKOUT FEATURE (E) T-MOBILE EQUIPMENT (6) ANTENNAS (3) TMAs (1) ANTENNA PLATFORM MOUNT (E) CARRIER MW ANTENNA (E) CARRIER ANTENNAS (TYP.J (E) 71'4" MONOPOLE TOWER (P) T-MOBILE FEEDLINES: (3) NOKIA HCS 2.0 HYBRID CABLES (1-1/2") (E) T-MOBILE FEEDLINES: (12) COAX CABLES (7/8") 526.5 FT AMSL NOTE: NEW EQUIPMENT CANNOT BE MOUNTED TO TOWER. RELOCATE MOUNTED EP ^ ENT TO CUSTOMER MOUNT. El ❑M(OhR ElEQUQUIIINGT (E) T-MOBILE ANTENNA (E) T-MOBILE ANTENNA 7668 WARREN L'ARKIX-:`�Y ANDREW - DB O BE REM A2M TO BE REMOVED (ALPHA) ANDREW - HBXX-3319DS-A2M 0° AZIMUTH TOWER &ANTENNA STANDARD NOTES: FRISCO, TX 75034 TOTAL, 1 PER SECTOR TO REMAIN (6 TOTAL, 1 PER SECTOR) ALPHA, BETA &GAMMA) A. TOWER STRUCTURAL ANALYSIS BY [TBD). DATED [TBD). PROJECT # [TBDI. L (FOX) NO NEW ANTENNAS OR EQUIPMENT INSTALLED WITHOUT APPROVAL 300° AZIMUTH OF STRUCTURAL ENGINEER AND CROWN CASTLE. (E) T-MOBILE ANTENNA B. MOUNT ANALYSIS BY [TBD). DATED [TBD). PROJECT # [TBD). NO NEW CROWN PLATFORM MOUNT TO REMAIN (DELTA) 60° AZIMUTH OF STRUCTURAL ENGINEER AND CROWN CASTLE. MOUNT$ TU MOUNT REINFORCEMENT INSTALLED WITHOUT APPROVAL0:0 CASTLE (I TOTAL) C. INSTALLED EQUIPMENT MUST HAVE A MATCHING CROWN APPLICATION AND STRUCTURAL ANALYSIS 6191 N STATE HWY 161, SUITE 200 (E) T-MOBILE NOKIA- FHFB UNIT (E) T-MOBILE DIPLEXER D. VERIFY AZIMUTHS WITH RFDS. IRVING, TX 75038 TO BE REMOVED COMMSCOPE - ECC 1920-VPUS (6 TOTAL, 1 PER SECTOR) TO BE REMOVED E. T ANTENNA SEPARATION REQUIRED. CONTRACTOR TO MOVE (E) (GAMMA) (24 TOTAL) ANTENNAS TO ENDS OF MOUNT AS REQUIRED. 240° AZIMUTH (E) T-MOBILE COVP TO BE REMOVED F. MOUNT COMPLIANCE IS BY OTHERS. NO NEW ANTENNAS OR EQUIPMENT [plm (2 TOTAL) INSTALLED ON MOUNTS WITHOUT THE APPROVAL OF ASTRUCTURAL ENGINEER. P. MARSHALL &ASSOCIATES ` 1¢ (E) 71'-6" MONOPOLE TOWER G. PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, (E) TOWER AND TOWER FOUNDATION MUST BE ANALYZED BY A LICENSED 6801 PORTWEST DR STE 100, (E) T-MOBILE STRUCTURAL ENGINEER TO VERIFY TOWER IS CAPABLE OF SUPPORTING HOUSTON, TX 77024 N FRBG UNIT THE PROPOSED LOADS. REFER TO STRUCTURAL ANALYSIS BY OTHERS. OFFICE 713-677-0964 To BE REMOVED TO BE � (BETA) (3 TOTAL, 1 PER SECTOR 120° AZIMUTH H. PROPOSED ANTENNA PLACEMENT LOCATION TO BE FIELD VERIFIED BY ALPHA, BETA & GAMMA) GENERAL CONTRACTOR PRIOR TO CONSTRUCTION TO AVOID ANY INTERFERENCE OR SHADOWING OF EXISTING ANTENNAS. IF (E) T-MOBILE INTERFERENCE OR SHADOWING OF EXISTING ANTENNAS IS DISCOVERED NOKIA- FRIJ UNIT - 1 ` `� DURING FIELD VERIFICATION, PLEASE CONTACT (A&E VENDOR) FOR TO BE REMOVED DESIGN REVISION PRIOR TO ANY NEW ANTENNA INSTALLATION. (6 TOTAL, I PER SECTOR) (ECHO) E c� it T-MOBILE NA 180° AZIMUTH (E) T-MOBILE TMA COMMSCOPE I. DURING INSTALLATION, THE RADIOS ARE NOT TO EXCEED E FROM THE SITE UMBER: TWIN STYLE 3C - TMAH 921 B78-21 A WORKING SURFACE TO THE TOP OF RADIOS. DA�1328A TO REMAIN 1 O (3 TOTAL) /1�L 1/ EXISTING ANTENNA LAYOUT _ SCALE: NOT TO SCALE 0 o w �o wvUigx a wo� (E) T-MOBILE ANTENNA PLATFORM MOUNT (1 TOTAL) ��vryry�/ (P) T-MOBILE PANEL ANTENNA J NOKIA - AEHC (3 TOTAL, 1 PER SECTOR ALPHA, BETA & GAMMA) (E) 71'-6"MONOPOLE TOWER 3 FINAL ANTENNA LAYOUT SCALE: NOT TO SCALE ol (E) T-MOBILE ANTENNA ANDREW-HBXX-3319DS-A2M (6 TOTAL, 1 PER SECTOR) (P) T-MOBILE UNIT NOKIA - AHFIG (6 TOTAL, 1 PER SECTOR) — (P) T-MOBILE PANEL ANTENNA COMMSCOPE - FFVV-65C-R3-V 1 (3 TOTAL, 1 PER SECTOR ALPHA, BETA & GAMMA) (P) T-MOBILE COMMSCOPE HCS 2.0 BREAKOUT FEATURE (3 TOTAL) (E) T-MOBILE TMA COMMSCOPE TWIN STYLE 3C - TMAH 921 B78-21 A (3 TOTAL) w NOTE: G.C. TO FEILD VERIFY ANTENNA PLACEMENT WITH THE T-MOBILE CM PRIOR TO INSTALL. SEE TOWER TOP EQUIPMENT SCHEDULE ON SHEET C3 FOR ANTENNA MODEL INFORMATION. PM&A DID NOT PERFORML MOUNT ANALYSIS FOR THTINGOR PROPOSED LOADINGWN.REFER TO STRUCTURAL BYRS. PLANNING ADMINISTRATIVE APPROVAL COPPELL r 12/08/2022 BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 08/16/2022 EAK PRELIM SBE 0 11/11/2022 EAK FINAL SBE �- P�� OF . •.. PATRICK W MARSHAL_L ........................................ 86101 F 1� ,-.20NAL FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A I.ICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A NUMBER: 22CT2M-132 SHEET NUMBER: REVISION: C-3 01 J TOWER TOP EQUIPMENT SCHEDULE ANTENNASECTOR ANTENNA PLACEMENT ANTENNA MARK ANTENNA MODEL ANTENNA AZIMUTH RRU MODEL DIPLEXER/TMA MODEL COVE MODEL ANTENNA CABLE DESCRIPTION ALPHA '3* 'A3' (I) NOKIA-AEHC (P) 0° - - (3) BREAKOUT FEATURE - EXACT SPECS TBD (P) (3) 1-1/2" DIA. X 125' FT 2.0 HYBRID CABLE- (P) "(6) 7/8" COAX CABLES REQUIRED FOR FINAL TOWER CONFIGURATION" *2* AT (1)COMMSCOPE-FFVV-65C-R3-V1(P) 0° (1)AHLOA(P) - '1* 'Al' (1) ANDREW -HBXX-3319DS-A2M (E) 0° (1) AHFIG (P) - BETA `6- '133' (1) NOKIA -AEHC (P) 120° - - *5* '132' (1)COMMSCOPE-FFW-65C-R3-V1(P) 120° (1)AHLOA(P) - -4* 'Bl' (1) ANDREW - HBXX-3319DS-A2M (E) 120° (1) AHFIG (P) - GAMMA .9. 'C3 (I) NOKIA -AEHC (P) 240° - - `8. 'C2' (I)COMMSCOPE-FFW-65C-R3-V1(P) 240° (1)AHLOA(P) - *7* 'C1' (1) ANDREW -HBXX-3319DS-A2M (E) 240° (1) AHFIG (P) - DELTA 10` 'DI' (1) ANDREW -HBXX-3319DS-A2M (E) 60° (1) AHFIG (P) - ECHO .11` 'El' (1) ANDREW -HBXX-3319DS-A2M (E) 180° (1) AHFIG (P) - FOX -12- TV (1) ANDREW -HBXX-3319DS-A21,4 (E) 300° (1) AHFIG (P) - NOTE: (P) DENOTES PROPOSED EQUIPMENT; (E) DENOTES EXISTING EQUIPMENT EQUIPMENT NOTES: 1. THE HYBRID CABLE LENGTHS SHOWN ARE ONLY ESTIMATES AND SHOULD NOT BE USED FOR ORDERING MATERIALS. CONFIRM THE REQUIRED HYBRID CABLE LENGTH WITH T-MOBILE PRIOR TO ORDERING OR INSTALLATION. 2. THE CONTRACTOR SHALL TEST THE OPTICAL FIBER AFTER INSTALLATION IN ACCORDANCE WITH T-MOBILE STANDARDS AND SUPPLY THE RESULTS TO T-MOBILE. 3. THE CONTRACTOR SHALL CONFIRM THE TOWER TOP EQUIPMENT LIST ABOVE WITH THE FINAL T-MOBILE REDS PRIOR TO INSTALLATION. 4. ALL EXISTING AND PROPOSED ANTENNA CABLES SHALL BE COLOR CODED PER T-MOBILE STANDARDS. 5. REFER TO NOKIA SIEMENS NETWORKS EQUIPMENT INSTALLATION STANDARDS FOR ADDITIONAL INFORMATION. 6. REFER TO EQUIPMENT MANUFACTURER'S SPECIFICATION SHEETS FOR ADDITIONAL INFORMATION NOT LISTED ABOVE. 7. SCAN ALL T-MOBILE ASSET ITEMS TO SITE DURING CONSTRUCTION. INSTALLER NOTES: 1. COMPLY WITH MANUFACTURERS INSTRUCTIONS TO ENSURE THAT ALL RRHs RECEIVE ELECTRICAL POWER WITHIN 24 HOURS OF BEING REMOVED FROM THE MANUFACTURER'S PACKAGING. 2. DO NOT OPEN RRH PACKAGES IN THE RAIN. 3. ALL PIPES, BRACKETS, AND MISCELLANEOUS HARDWARE TO BE GALVANIZED UNLESS NOTED OTHERWISE. T-MOBILE RRH AND HARDWARE SUPPLIED BY MANUFACTURER (TYP) MOUNTING BRACKET (SUPPLIED W/ ANTENNA) MOUNTING PIPE (TYP) ANTENNA MOUNTING PIPE VALMONT- RRU DSM AND HARDWARE (TYP) MOUNTING BRACKET (SUPPLIED W/ ANTENNA) ANTENNA WITH RRHs MOUNTING DETAIL �/ SCALE: NOT TO SCALE NEW ANTENNA TOWER LOADING SUMMARY EXISTING QUANTITY REMOVE QUANTITY EQUIPMENT TYPE ADD QUANTITY TOTAL QUANTITY 9 3 PANEL ANTENNA 6 12 12 6 COAX CABLE 0 6 27 24 TMA/DIPLEXER 0 3 6 6 FRIJ 0 0 6 6 FHFB 0 0 3 3 FRBG 0 0 0 0 AHFIG 6 6 0 0 AHLOA 3 3 2 2 HIGH CAP. HYBRID CABLE 0 0 2 2 LARGE COVP 0 0 0 0 2.0 HYBRID CABLE 3 3 0 0 BREAKOUT FEATURE 3 3 (� ANTENNA AND CABLE SCHEDULE ( SCALE: NOT TO SCALE T-MOBILE ANTENNA (12 TOTAL) #2 AW G STRANDED COPPE INSULATED GROUND WIR ANTENNA AND RRU DIAGRAM SCALE: NOT TO SCALE ANTENNA MOUNT DETAIL IS SHOWN DIAGRAMMATICALLY AND IS NOT REPRESENTED AS SITE SPECIFIC. SEE STING TOWER ANTENNA ORIENTATION PLAN FOR EXISTING AND PROPOSED EQUIPMENT LOCATIONS. REFER TO STRUCTURAL PLATFORM MOUNT AND/OR MOUNT ANALYSIS FOR DETAILS PRIOR TO CONSTRUCTION. PLANNING AOMINIBTRATIVE APPROVAL PPE R ANTENNA :ROUND BAR COPPELL iAX CABLES 12/08/2022 ON WON rs "bj i Will 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HWY 161, SUITE 200 IRVING, TX 75038 Nmo P. MARSHALL & ASSOCIATES 6801 PORTWEST DR- STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 08/16/2022 EAK PRELIM SBE 0 11/11/2022 EAK FINAL SBE �,rx- P�� o F • �1i� ; � ••�11 PATRICK W MARSHAL_L ........................................ ,��. 86101 1i�o F FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A I.ICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A NUMBER: 22CT2M-132 SHEET NUMBER: REVISION: C-4 0 J Section 1 - Site Information Bile ID: DM132M Site Name: Craven 076558 latitude: 32.93485 Sintus: FI-1 Bite Class: Monopole Longitude:-97.001% I.- 30 Bite Type: B—O, Non B,,Tdhg Atltlresi 1305-13 Wrangler Protect Type: Anc Plan Year'. 2022 City, Slate: Coppell, TX ApP.— 102fi20224:41:01 PM Markel: DALLAS TX Reion: SOUTH APProvad By: MILIND.GANDHI6®T-MOBILE.COM vendor: Nokia Last Motleied 102&20224:41 Ui PM Land —Crown Wstle Last Modified By: MILIND.GANDHI6@T-MOBILE.COM RAN Template: —1EK SR AL Template: 56]61EK SR Sector Court: 8 na Count 12 Coax Line Court'. 0 MA Court: 0 RRU Count 9 Proposed RAN Equipment Template: 56]61EK BR Pndpaum 1 2 3 4 Endosure Type over Top Mount (Noltla alto HPL3 fi00A Bile Support cabinet Mcillery Equipment (Nokia) Ito LB3 Battery Cabinet (4 stings) Retlia DIM Basebantl g5'QOx2 �2m�02) (opRX) (DARK) G� 09m asebantl Bubmatlule A9]OOxS AN2m�04) (DARK) (OaRIq Basebantl Babcock AMIA (x2 Transpod System e5R IXRe V2 (Gen2j Hybritl Cable System is HCS 20 Jumper Cable mle'Select Len9iM1' (x 12) d ROOST Voltage Bmaterwl4 Ma HCS 2.0 Tmnk'Seled NenOtM1' (x 3) re Maame mr Delm vonage Booster Junction Box Naka HCB 2.0 Tmver JuncdOn Box (x 3) RAN Scope of WOM: 10r92022: RFDS updatetl tc PH2Y design. OUip on top'. 3 FFW-65C-R3-V1+(3) AEHCe(6) HBXX-3319DSA2M 6 AHFIG+(3)AHLOA (3) HCS 2.0 trunk mblas (1) H—rtumpers (3) TMM Nate: (3) AHFG ♦ (3) AHLOA will conned ro 1st HCS 2.0 using vdtage booster (3) AHFIG will conned to 2M HCS 2.0 (3) AEHC will mm.db 3,,1 HCS 2.0 Rx Freq: mk-600TBW nk(MHz) Uplink(MHz) 81]-62]6G873 Bl--]00 Oownlink (MHz) Upllnk (MHz) 729-]34699-]01 Block- PCs Dmvnllnk (MHz) Uplink (MHz) 1945-196518651885 AWS Downlink (MHz) Uplink (MHz) 2110-2115,213521551710-1715.1735-1755 A-., Downlink (MHz) Uplink (MHz) 249fi-2fi902496-2690 Sector 1 (Proposed) view from front (Note: the images show view from behind) Coverege Type p-Outtlmr Mew Mtenna 1 2 3 Mbnna Motlel Md.-HBXX-3319DS W(puad) Commscope-FFW{SGRSVI(Odo) AEHC(A— lin. O O 0 M. Tilt O O O Height O O 0 Pom P7 P2 P3 P4 P5 P6 P7 Adiva TecM1 U220 Lt900 L2100 G1900 T Lt900 9100 G1900 L800 200 Nfi00 V00 L600 E09 N0500 Dart Tech 2100 1900 2100 N1900 R�trid�TaaM1 Dammm. TecM1 E. Tit Cables TMAs Diplexerl Combiners Ratla Sector Equipment Umm­ Equipment scope of Work Sector 2 (Proposed) view from front (Note: the images show view from behind) Coverege Type p_OUWmr Macro Antenna 1 2 3 Antenna Motlal Mtlrew-HBXX-3319—M(0-0) FFW{dGRSV1(OJ) AEHC(Acdve Antenna- M111.1 MIMO) —.1, O O O M. Tilt O O O Height O O 0 rods P1 P2 P3 P4 P5 P6 P7 Adwe Tact' L1B00 t2100 2100 G1900 L1900 t2100 2100 G1900 L]00 L-1 Nfi00 L600 N600 L]00 N2500 rk Tent 1900 2100 2100 N1900 Reslridetl TecM1 Demmm. TecM1 E. Tit Cables TMI Diplexerl Combiners Sector Equipment U­mctetl Equipment Smpe of Work: Sector 3 (Proposed) view from front (Note: the images show view from behind) Coverage Type p-OUWmr Mew A—— 1 2 3 Mtenna Motlel Andrew-HBXX-3319DS W(Ouad) Commscope-FFW{SGRSVI(Odo) AEHC(Acd. Mlenna-Massive MIMCO Azimuth 240 240 240 M. Tilt O O Q HeigM1t © O O Pom 1 P1 P2 P3 P4 P5 P6 P7 Alive Tech 1900 L2100 U2100 G1900 1900 L2100 U2100 G1900 L100 L800 Nfi00 200 L600 E09 N25o0 Dart Tech 1900 2100 1900 2100 ResVided TecM1 Oecomm. TecM1 E Tit Ceblas TM. Diple erl Combiners R0 sector Equipment Umm­ Equipment: scope of Work: (D RID' SCALE: NOT TO SCALE Sector (Proposed) view from front (Note: the images show view from behind) Coverage Type A-OUWoor Macro Mtenna 1 Anmnna Model Md.-HS-3319D5-A2M(Ouatl) —Oh 9 M. Tit Q Haight Q Pans P1 P2 Allve TecM1 O L1900 L2100 L1900 Dark Tec1, N2100 N1900 N2100 N1900 Rastri d TecM1 Dl­ E. Tilt Cables TMM Diplexerl co 0b Sector Equipment Unconnected Equipment: Bmpa or WOA'. Sector 5 (Proposed) view from front (Nate: the images show view from behind) C .Ne TYDe A-OUWoor Macro Mtenna Anmnna Model Antlrew-HBX%3319D5-A2M (Ouetl) -Oh eB M. Tit Q Haight Pans P1 P2 Allve TecM1 L1900 L2100 L1900 L2100 Dark TecM1 N1900 N2100 N1900 N2100 Resd d TecM1 Dammm. TecM1 E. nit Cables T.M Diplexer/ Dambine,a B 01 Equipment Umm-edetl Equipment Smpe of Wark'. Sector 6 (Proposed) view from front (Note: the images show view from behind) Cove rage Type A_Outtloor Macro Mtenna Antenna Modal Mtlrew-HBX%3319D5-A2M (Ouatl) Azlmuth 300 Tit O Height Q Po P1 P2 Alive TecM1 L2100 L1900 L2100 L1900 D.A TecM1 N2100 N1900 N2100 EN ResN d Tech E. Tilt Cable Diplexerl Combiners Ratlia Sector Equipment Ummm.datl Equipment: S.P.— Work'. PL IIJNIG ADMINISTRATIVE APPROVAL COPPELL 12/08/2022 ON E Me rs "bj i W131 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HWY 161, SUITE 200 IRVING, TX 75038 p ° P. MARSHALL & ASSOCIATES 6801 PORTWEST DR STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T—MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 — COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 08/16/2022 EAK PRELIM SBE 0 11/11/2022 EAK FINAL SBE 01� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A NUMBER: 22CT2M-132 SHEET NUMBER: REVISION: C-5 0 J Configuration 56761EK.—SR For 5G and LTE Airscale BB dimensioning refer to Fiber Port matrices. (Delta, Epsilon & Zeta) (Alpha, Beta & Gamma) PLUMBING DIAGRAM SCALE: NOT TO SCALE FDD - Lowband B 12 (L700) — 5 M H z B71 (L600)-10 MHz B71 (N600) — 10 MHz FDD - Midband B4 (L2100)— 20 MHz N2100-20MHz B2/B25 (L1900) — 20 MHz N1900 (B25) — 20 MHz LAWS3- 5MHz TDD - Band 41 L2.5(2.5GHz)— 60 MHz N41(2.5GHz)— 100MHz+2nd carrier (<=80M Hz) PLANNING AOMIN-RATNE APPROVAL COPPELL 12/08/2022 AN 0 ON E Me rsrbj 5113 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HWY 161, SUITE 200 IRVING, TX 75038 p ° O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 08/16/2022 EAK PRELIM SBE 0 11/11/2022 EAK FINAL SBE IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A NUMBER: 22CT2M-132 SHEET NUMBER: REVISION: C-6 0 NOKIA AEHC WEIGHT (WITHOUT MOUNTING HARDWARE): 99.2 LBS. SIZE (HxWzD): 35.43x22.83x8.26 IN. 1 AEHC ANTENNA DETAIL SCALE: NOT TO SCALE NOKIA AHFIG WEIGHT (WITHOUT MOUNTING HARDWARE): 79.4 LBS. SIZE (HxWzDJ: 27.6x13.4x5.6 IN. AHFIG RRU DETAIL 4 SCALE: NOT TO SCALE COMMSCOPE - FFVV-65C-R3-V 1 WEIGHT (WITHOUT MOUNTING HARDWARE): 124.60 LBS SIZE (HI95.90x25.20x9.30 IN. MOUNTING HARDWARE P/N: BSAMNT-4 RATED WIND VELOCITY: 150.0 MPH 2 FFVV-65C-R3-V1 ANTENNA DETAIL SCALE: NOT TO SCALE FRONT SIDE O TOP WEIGHT (WITHOUT MOUNTING HARDWARE): 23.5 LBS. SIZE (HI 14.Ox16.0x8.0 IN. Jr HCS JUNCTION -BOX DETAIL SCALE: NOT TO SCALE _E7 NOKIA - AHLOA WEIGHT (FULLY EQUIPPED): 83.8 LBS SIZE (HI 22.1 x12.1x7.4 IN. CONNECTOR TYPE: 4.3-1 FEMALE 3 AHLOA RRU DETAIL SCALE: NOT TO SCALE BASED BOX ASSEMBLY HEAT SHRINK TU 3RID CABLE WEIGHT (WITHOUT MOUNTING HARDWARE): 23.5 LBS. ALLIANCE SIZE (WxHxD): 9.3x14.9x5.8 IN. COMMSCOPE SIZE (WxHxD): 6.7x16.9x4.7 IN. NWS SIZE (WxHxD): 10.2x16.Ox3.2 IN. BREAKOUT FEATURE DETAIL SCALE: NOT TO SCALE PLANNING ADMQJISTRATIVE APPROVAL COPPELL /.(-7 `I weeE 12/08/2022 ON E Me rsrbj 51 IN 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HWY 161, SUITE 200 IRVING, TX 75038 p ° 0 P. MARSHALL & ASSOCIATES 6801 PORTWEST DR STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A O8/16/2022 EAK PRELIM SBE 0 11/11/2022 EAK FINAL SBE IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A NUMBER: 22CT2M-132 SHEET NUMBER: REVISION: C-7 0 Outer Diam Weight Min. Bend Rad DC Conductors Armor Conductor Termination Singl�Mode Fibers Fiber Tnrminafinn +BINET: MAXIMUM INSTALLED WEIGHT: -551 LBS. (W/O EQUIPMENT) !Y 3 CABINET: MAXIMUM INSTALLED WEIGHT: -540 LBS. (W/O BATTERIES) 7668 WARREN PARKWAY FRISCO, TX 75034 .able General Specifications CROWN mm® A''...Ilarc NWS - _ 0:0 CASTLE e ®'\, 6191 N STATE HWY 161, SUITE 200 1.46" 1.55" 1.48" // e \ _ _ , IRVING, TX 75038 1.611b/it 1,7116/R 1.6116/k 30.01, 35.0" 14.6" 18.6" 21.5" �' �` = .,,rc �I oo o e 0 M o e PIN 12x6AWG 12x6AWG 12 x6AWG - - O O ® P. MARSHALL & ASSOCIATES Corrugated Corrugated Cu tape, PVC U O U = e ° 6801 PORTWEST DR- STE 100, Cu AI CommScap ' _ _ ° HOUSTON, TX 77024 °°°°°°°°°°°°° °° o None None None e 0 °® °°_°°°°,°,,,° ° OFFICE 713-677-0964 °°°° °°°°° °°° r. 48 48 48 N LC pair LC pair LC pair i HCS 2.0 SPECIFICATIONS 1 SCALE: NOT TO SCALE 2 General Product Overview PSU 48 13 rywre+ A Mountie bra. BndetfalV'rxkimulatans. arwcke[anbs rvverssa. a DCIn DavereEHe+ficebrcon bles M1wn Ne er ainm button. c i:run,.lm, — hl .. ar ronn..e .i■�ca Fa„e,� c r�:e ronneaon cweee r�.a. r+n,�n,i. r«wnes na awt "c oc .wc a.m wue:lo aawa:. N ore�ne wnnenor -.wnasm�:�e F •zee"" rsu.a .� velmge 6aosler oeeign speoino.aon T • •b'1o:>i The neneral speufimtlons for the PSU 48 13 are as follows - PSUUnt K+t SKU34132 n w..wtr e.,.tirwe my e"n.n,.n ,svr +eanuu,e ntaLi uG/sowaaml ,f h E+ia able esozv3o 3 ruses'�nesch tab ssazvwe lutuEw.o", eov,uz 3heecinexh to ssnWso Imn.wbw,my, t•/. PSU 4813 4 SCALE: NOT TO SCALE r amfle+ 0 0 O O 2 DELTA HP -LARGE 3 CABINET / LARGE BATTERY 3 CABINET SCALE: NOT TO SCALE SPACE INTENTIONALLY LEFT BLANK Jr NOT USED SCALE: NOT TO SCALE NOKIA AMIA WEIGHT: 11.2 LBS. SIZE (HxWxD): 5.2xl 7.6xl 5.7 IN. 3 AMIA EQUIPMENT DETAIL SCALE: NOT TO SCALE SPACE INTENTIONALLY LEFT BLANK NOT USED SCALE: NOT TO SCALE PLANNING ADMINISTRATIVE APPROVAL T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./QA A 08/16/2022 EAK PRELIM SBE 0 11/11/2022 EAK FINAL SBE 01� IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A I.ICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. COPPELL PM&A NUMBER: 22CT2M-132 `� ¢E SHEET NUMBER: REVISION: 12/08/2022 C-7.1 0 GROUNDING KEY NOTES: OEXISTING EQUIPMENT GROUND RING. (FIELD VERIFY LOCATION) OGROUND PROPOSED HPL 3 CABINET TO EXISTING GROUND RING PER MANUFACTURE'S SPECIFICATIONS W/ #2 AWG SOLID TINNED COPPER WIRE. OGROUND PROPOSED LB3 CABINET TO EXISTING GROUND RING PER MANUFACTURE'S SPECIFICATIONS W/ #2 AWG SOLID TINNED COPPER WIRE. OGROUND AMIA SUBRACK TO MGB W/ #2 AWG SOLID TINNED COPPER WIRE. OGROUND PROPOSED JUNCTION BOX TO EXISTING GROUND RING PER MANUFACTURE'S SPECIFICATIONS W/ #2 AWG SOLID TINNED COPPER WIRE. NOTE: ALL TRENCHING REQUIRED WITHIN COMPOUND SHALL BE PERFORMED BY HAND -DIGGING ONLY. O (P) (3) 1-1 /2" NOKIA 2.0 HYBRID TRUNK W/ BREAKOUT FEATURE ROUTED FROM J-BOX TO TOWER ALONG ICE BRIDGE (±125' CABLE LENGTH) (E) T-MOBILE FEEDLINES: (6) 7/9' COAX CABLES / GROUNDING LEGEND INSPECTION WELL VERIFY LOCATION W/ CONSTR. MGR. w 519M 0'-0" COPPER CLAD GROUND J(Y�1 ROD, 10' O.C. (TYP) #6 AWG STRANDED &INSULATED 42 AWG SOLID COPPER TINNED GROUND BUS BAR EXOTHERMIC WELD (CADWELD) ■ (UNLESS OTHERWISE NOTED) MECHANICAL CONNECTION (E) 71'-6" MONOPOLE TOWER a ® ® u O 0 0 c (P) T-MOBILE (3) NOKIA HCS 2.0 JUNCTION BOX (FIELD VERIFY BEST LOCATION) (E) T-MOBILE UTILITY POST I P (E) T-MOBILE GPS ANTENNA (TYP.) r---------, I I I ( I I (P) T-MOBILE (P) T-MOBILE LB3 BATTERY HE LARGE 3 CABINET CABINET I I I I I I L------ J 0 0 O F­ PEA __ ADMINLST TN APPROVAL COPPELL 12/08/2022 O (E) T-MOBILE 200A METER x x (E) T-MOBILE FLOOD LIGHT T T-MOBILE (E) T-MOBILE O W CABINET DISCONNECT x (E) T-MOBILE PPC & TELCO CABINET x olf❑ ❑1S V ZSObLSIS� El 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HWY 161, SUITE 200 IRVING, TX 75038 p ° P. MARSHALL & ASSOCIATES 6801 PORTWEST DR STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T—MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 — COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE cI (E) T-MOBILE 10'-11"x 16-0" x ISSUED FOR: EQUIPMENT PLATFORM LREV_DRWN DESCRIPTION DES./QW/ (E) & (P) EQUIPMENT(P) T-MOBILE (1) AIRSCALE FAK PRELIM SBE AMIASUBRACK MOUNTED E EAIi FINAL SBE INSIDE HP LARGE 3 CABINET (FIELD VERIFY BEST LOCATION) (E) T-MOBILE x CIENA RESERVED SPACEFOR FUTURE EXPANSION CABINET x (E) T-MOBILE UTILITY FRAME (E) T-MOBILE x ICE BRIDGE (TYP.) (E) TOWER J I FND PAD � O (E) T-MOBILE ICE BRIDGE POST (TYP.) O U- (E) CARRIER ICE BRIDGE (TYP.) 3 4 2 X X X X X X X XX X X C> \ (E) CHAIN -LINK FENCE (TYP.) GROUNDING SITE PLAN SCALE: I"=1'V'(FULL SIZE] N 1/2'�I'-0"(1 lxl7) r*..............................:* i PATRICK W MWR AL_Lio 8 610 1 ICE N S'���G���� FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A I.ICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A NUMBER: 22CT2M-132 SHEET NUMBER: G-1 REVISION: 1 0 TO ANTENNA COAX COPPER/GALVANIZED GROUND BAR O o o: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O O O O O O O O O O O O O Q TWO HOLE LONG BARREL COMPRESSION LUG ITYP) NOTES: I. DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED. 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO ANTENNA MOUNT STEEL. (D ANTENNA SECTOR GROUND BAR DETAIL SCALE: NOT TO SCALE TO TOWER MOUNTED EQUIPMENT (TYP) TO ANTENNA STANDARD COAX — CABLE GROUND KIT ITYP) #6 STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION (OR AS PROVIDED WITH GROUND KIT) (TYP) COAX CABLE (TYP FOR ALL) TO BTS EQUIPMENT VIA TRAY OR ICE BRIDGE MONOPOLE ANTENNA GROUND BAR LOCATED AT MCL (BONDED TO TOWER STEEL) 2 HOLE LUG (TYPI MECHANICAL CONNECTION (TYP) COAX GROUND BAR WITH INSULATORS, CONNECTED DIRECTLY TO THE BOTTOM OF MONOPOLE. SEE NOTE 1. 2/0 TINNED BARE COPPER WIRE MONOPOLE PIER GROUND WIRE SEE NOTE 3 GROUND WIRE NOTE 3 INSPECTION WELL EXOTHERMIC WELD TYP NOTES: 1. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATIONS AND CONNECTION ORIENTATION. COAXIAL CABLES EXCEEDING 200 FEET ON THE TOWER SHALL HAVE GROUND KITS AT THE MIDPOINT. PROVIDE AS REQUIRED. 2. ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE USA INC. TOWERS. ALL MECHANICAL CONNECTIONS SHALL BE TREATED WITH AN ANTI -OXIDANT COATING. 3. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE RECOGNIZED EDITION OF ANSI/TIA 222 AND NFPA 780. 4 TYPICAL ANTENNA CABLE GROUNDING SCALE: NOT TO SCALE TO ANTENNA COAX COPPER/GALVANIZED GROUND BAR o O 0000000000000 O O 0000000000000 Q O O O O O O O O O O O O O O O O O 0 #2 SOLID TINNED COPPER CONDUCTOR TO TOWER/SHELTER GROUND RING (2 TYP. FOR BOTTOM TWO HOLE LONG BARREL COMPRESSION LUG (TYP) GROUND BAR ONLY) NOTES: 1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). 3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. TOWER/SHELTER GROUND BAR DETAIL SCALE: NOT TO SCALE STAINLESS STEEL BOLT (TYP) STAINLESS STEEL FLAT WASHER 2-HOLE CRIMP/ InP) COMPRESSIONlip CONNECTOR , GROUND BAR STAINLESS STEEL FLAT WASHER STAINLESS STEEL (TYP) BELLVILLE WASHER STAINLESS STEEL NUT (TYP) (TYP) SINGLE CONNECTOR AT GROUND BARS DRAGON TOOTH WASHER (TYP) STAINLESS STEEL BOLT STAINLESS STEEL FLAT WASHER - STEEL 2-HOLE CRIMP/ COMPRESSION STAINLESS STEEL CONNECTOR FLAT WASHER (TYP) STAINLESS STEEL STAINLESS STEEL NUT BELLVILLE WASHER (TYPI (TYP) SINGLE CONNECTOR AT STEEL OBJECTS STAINLESS STEEL SELF -DRILLING STAINLESS STEEL METAL SCREW FLAT WASHER (TYP) (TYP) 2-HOLE CRIMP/ COMPRESSION CONNECTOR DRAGON TOOTH METALLIC OBJECT WASHER (TYP) SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS Jr HARDWARE DETAIL FOR EXTERIOR CONNECTIONS SCALE: NOT TO SCALE T' PVC PLUG 8" PVC PLUG CPLG. (THIRD.) T/FINISH GRADE SUBGRADE #2 SOLID (TEST LOOP) Z NOTCH SIDES OF 8" PVC SCH 40 PIPE C2 a TO ALLOW EXIVENTRANCE OF p EXOTHERMIC WELD GROUND RING WIRE TRENCH BOTTOM 2/0 TINNED CU EXTERNAL CADWELD TEST LOOP TO TOWER GROUND RING WIRE GROUND RING WIRE NOTES: 5/8" 0 x 10'-0" LONG COPPER CLAD GROUND ROD 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) INSPECTION WELL DETAIL SCALE: NOT TO SCALE F'LwIiNRJG ApMPITS TRIE APPROVAL 6' WIDE METALLIC HTEL GRADE WARNING/LOCATOR TAPE AT 12" DEPTH N O z_ I=b� O EXOTHERMIC WELD GROUND RING 112 COPPER WIRE SOLID. TINNED FOR CARRIER AND ICE BRIDGE GROUNDLOOP GROUND RING 2/0 FOR TOWER GROUND LOOP GROUND ROD COPPER CLAD STEEL ROD W/MIN. 5/8 0 x 10'-0' LONG NOTES: 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30'BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) 6 LE: NOT GROUND ROD DETAIL SCATO SCALE ON 0 Me rs "bj i ME 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HWY 161, SUITE 200 IRVING, TX 75038 p ° P. MARSHALL & ASSOCIATES 6801 PORTWEST DR STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 08/16/2022 EAK PRELIM SBE 0 11/11 /2022 EAK PINAL SBE o F • �17� ; � •• 7C1� PATRICK W MARSHAL ................................... 86101 1� ,..20NAL FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A I.ICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A NUMBER: 22CT2M-132 SHEET NUMBER: REVISION: G-2 1 0 WEATHERPROOFING KIT (SEE NOTE 3) ANTENNA CABLE - WIRE SIZE BURNDY LUG BOLT SIZE #6 AWG GREEN INSULATED YA6C-2TC38 3/8" - 16 NC S 2 BOLT TYPE HS TYPE 2-YA-2 TYPE XA TYPE YA-2 TYPE GY #2 AWG SOLID TINNED YA3C-2TC38 3/8" - 16 NC S 2 BOLT � ^ #2 AWG STRANDED #2/0 AWG STRANDED #4/0 AWG STRANDED YA2C-2TC38 3/8" - 16 INC S 2 BOLT YA26-2TC38 3/8" - 16 INC S 2 BOLT YA28-2N 1/2'-16 NC 2 BOLT TYPE VV TYPE VN TYPE NC TYPE SS TYPE GR BURNDY GROUND LUG W/ H LONG BARREL EAT SHRINK (SEE CHART) (CLEAR) ■�j��, NUT GROUNDING (TYP) CONDUCTOR V �Y VVV LOCK WASHER (TYP) TYPE VS TYPE VB TYPE PT TYPE GP NOTE: 1. ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. 2. MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD. 1 CADWELD GROUNDING CONNECTIONS SCALE: NOT TO SCALE (TYPICALLY) I T'TO 24" 120" MAX. i 46 AWG STRANDED COPPER GROUND WIRE (GRO ", TO GROUND BAR). SEE NOTE 1 & 2 N Q 0 CABLE GROUND KIT CABLE CONNECTOR NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. CABLE GROUND KIT CONNECTION SCALE: NOT TO SCALE 3/8-11 xl"TAMPER RESISTANT BOLT (TYP) INSULATORS SEE NOTE 2. (TYP) WALL BRACKET (TYP) ® O Q ® L9 0 0 ® L9 UNIVERSAL COPPER ® GROUND BAR (4N20") LOCK WASHER P/N M10 (TYP) TWO -HOLE COMPRESSION LUG NOTES: 1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY QAS-STD-10091. NO MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, CAD -WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. GROUND BAR DETAIL Q SCALE: NOT TO SCALE TO ANTENNAS COAX JUMPER (TYF CONN WEATHERPROOF) (TYP. SEE t ANTENNA TO BTS EQUIPMEN GROUND BAR BOLT (SEE CHART) (TYP) BURNDY TWO HOLE LUG W/ LONG BARREL (SEE CHART) BARE WIRE TO BE NO-OX AT BOTH ENDS STRANDED (GREEN INSULATED) ONLY FOR #6 AWG (SEE CHART) WEATHERPROOFING I KIT (TYP) NOTES: GROUND KIT (TYP) 1. ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. 46 AWG MECHANICAL LUG CONNECTION COPPER/GALVANIZED COAX �/ SCALE: NOT TO SCALE GROUND BAR BONDED DIRECTLY TOWER #6 AWG MIN. FROM ANTENNA CABLE GROUND KIT NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. GROUND BAR ON SHELTER. BRIDGE, OR ON ANTENNA TON 2. WEATHERPROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE USED. l1/ GROUND CABLE CONNECTION � 4 SCALE: NOT TO SCALE NOTE: MINIMUM OF S/S NUT 3 THREADS TO BE (TYP) VISIBLE (TYP) S/S SPLIT WASHER 2 HOLE LONG (TYP) BARRELTINNED SOLID COPPER LUG 5/S FLAT (TYP) WASHER (TYP) TINCOATEDSOLID COPPER BUS BAR S/S FLAT WASHER (TYP) CHERRY INSULATOR INSTALLED IF REQUIRED S/S BOLT (TYP) LUG DETAIL SCALE: NOT TO SCALE "TWO HOLE LUG, OR EXOTHERN WELD TO BE USED WITH #2 AWG B/ CONDUCTOR WIRE TO BUILDII SERVICE GROUND OR GROUND RII GROUNDWIRE INSTALLATION �/ SCALE: NOT TO SCALE #2 TINNED SOLID IN 3/4' LIQUID TIGHT CONDUIT FROM 24" BELOW GRADE TO WITHIN T TO 6" OF CAD -WELD TERMINATION POINT. EXPOSED END OF THE LIQUID TIGHT CONDUIT MUST BE SEALED WITH SILICONE CAULK. CADWELD (TYP) TIE INTO EXISTING GROUND RING � TRANSITIONING GROUND DETAIL co. � SCALE: NOT TO SCALE im GROUNDING SHALL BE ELIMINATED WHEN GROUND BAR IS ELECTRICALLY BONDED TO METAL TOWER PLANNING ADMINISTRATIVE APPROVAL CQPPELL 12/08/2022 ofoo oMobUe ° 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HWY 161, SUITE 200 IRVING, TX 75038 p ° O P. MARSHALL & ASSOCIATES 6801 PORTWEST DR STE 100, HOUSTON, TX 77024 OFFICE 713-677-0964 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75019 EXISTING 71'-6" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 08/16/2022 EAK PRELIM SBE 0 11/11/2022 EAK FINAL SBE OF reds . ....................................... PATRICK W MARSHAL_L 86101 /ONAL E\ FIRM REGISTRATION #:13897 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A I.ICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A NUMBER: 22CT2M-132 SHEET NUMBER: G-3 REVISION: 1 0