STAMPED PDF. T-MOBILE DA01278B@ ATC 309374 COPPELL #2 (CO-LOCATE) TX (14185798_G3_03). AE(CD). REV0.ADM_APP.041823<<w=175; h=175; n=BLANK - SIG; a=11>> SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.G-001 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 TITLE SHEET LOCATION MAPVICINITY MAP PROJECT SUMMARY PROJECT DESCRIPTION SHEET INDEX SHEET NO:DESCRIPTION:REV:DATE:BY: G-001 TITLE SHEET 0 04/11/23 JBW G-002 GENERAL NOTES 0 04/11/23 JBW C-101 DETAILED SITE PLAN 0 04/11/23 JBW C-102 DETAILED EQUIPMENT PLAN 0 04/11/23 JBW C-201 TOWER ELEVATION 0 04/11/23 JBW C-401 ANTENNA INFORMATION & SCHEDULE 0 04/11/23 JBW C-501 CONSTRUCTION DETAILS 0 04/11/23 JBW E-501 GROUNDING DETAILS 0 04/11/23 JBW R-601 SUPPLEMENTAL R-602 SUPPLEMENTAL R-603 SUPPLEMENTAL R-604 SUPPLEMENTAL R-605 SUPPLEMENTAL R-606 SUPPLEMENTAL R-607 SUPPLEMENTAL R-608 SUPPLEMENTAL SITE LOCATION T-MOBILE REPLACEMENT AMENDMENT PLAN 56790EZ_SR_4SEC CONFIGURATION E SANDY LAKE RD. THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASED AND TOWER MOUNTED EQUIPMENT AS INDICATED PER BELOW: TOWER WORK: REMOVE EXISTING SPRINT EQUIPMENT AT @ 85' REMOVE (1) PLATFORM, (4) ANTENNA(S), (4) RRU(S), (4) TTA(S), (2) 0.41" CNT-400, (16) 7/8" COAX, & (2) HCS 2.0 TRUNK CABLE CABLE(S) @ 65' INSTALL (3) ANTENNA(S), (4) RRU(S), (1) PENDANT(S) AND (3) HCS 2.0 TRUNK CABLE CABLE(S) EXISTING (4) ANTENNAS, (4) RRUs, AND (2) PENDANTS TO BE RELOCATED FROM 65' TO 85' GROUND WORK: REMOVE (1) FCOA CABINET INSTALL (1) JUNCTION BOX EXISTING (2) JUNCTION BOX, (1) FCOA CABINET, (1) DELTA HPL3, AND (1) DELTA LB3 TO REMAIN PROJECT LOCATION DIRECTIONS PROJECT TEAM APPLICANT: T-MOBILE TOWER OWNER: AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ENGINEER: ATC TOWER SERVICES, LLC 3500 REGENCY PKWY STE 100 CARY, NC 27518 PROPERTY OWNER: SITE ADDRESS: 636 SANDY LAKE ROAD COPPELL,TX 75019 COUNTY: DALLAS GEOGRAPHIC COORDINATES: LATITUDE: 32.97105907 LONGITUDE: -96.97426225 GROUND ELEVATION: 483' AMSL GRAY INVESTMENT PROPERTIES, INC. 500 CR 115 N BUNNELL, FL 32110 FROM I-35 & SANDY LAKE ROAD GO WEST ON SANDY LAKE ROAD 4 MILES, TOWER ON NORTH SIDE IF ROAD 1.THE FACILITY IS UNMANNED. 2.A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCE A MONTH FOR ROUTINE INSPECTION AND MAINTENANCE. 3.THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LAND DISTURBANCE OR EFFECT OF STORM WATER DRAINAGE. 4.NO SANITARY SEWER, POTABLE WATER OR TRASH DISPOSAL IS REQUIRED. 5.HANDICAP ACCESS IS NOT REQUIRED. 6.THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS AN ELIGIBLE FACILITIES REQUEST ENTITLED TO EXPEDITED REVIEW UNDER 47 U.S.C. § 1455(A) AS A MODIFICATION OF AN EXISTING WIRELESS TOWER THAT INVOLVES THE COLLOCATION, REMOVAL, AND/OR REPLACEMENT OF TRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIAL CHANGE UNDER CFR § 1.61000 (B)(7). PROJECT NOTES COMPLIANCE CODE UTILITY COMPANIES ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1.2015 INTERNATIONAL BUILDING CODE (IBC) 2.2020 NATIONAL ELECTRIC CODE (NEC) 3.LOCAL BUILDING CODE 4.CITY/COUNTY ORDINANCES ATC SITE NAME: COPPELL #2 (CO-LOCATE) ATC SITE NUMBER: 309374 T-MOBILE SITE NAME: SANDY LK-CINGULAR #3423 T-MOBILE SITE NUMBER: DA01278B SITE ADDRESS:636 SANDY LAKE ROAD COPPELL,TX 75019 SITE CLASS: MONOPOLE POWER COMPANY: TXU PHONE: (800) 242-9113 TELEPHONE COMPANY: SBC PHONE: (800) 559-7928 SAMUEL BLVDN MOORE RD. <<w=175; h=175; n=BLANK - SIG; a=11>> SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.G-002 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 GENERAL NOTES GENERAL CONSTRUCTION NOTES: 1.OWNER FURNISHED MATERIALS, T-MOBILE "THE COMPANY" WILL PROVIDE AND THE CONTRACTOR WILL INSTALL A.BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE SHELTER (GROUND BUILD/CO-LOCATE ONLY) B.AC/TELCO INTERFACE BOX (PPC) C.ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILD/CO-LOCATE ONLY, GC TO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION) D.TOWERS, MONOPOLES E.TOWER LIGHTING F.GENERATORS & LIQUID PROPANE TANK G.ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTING H.ANTENNAS (INSTALLED BY OTHERS) I.TRANSMISSION LINE J.TRANSMISSION LINE JUMPERS K.TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITS L.TRANSMISSION LINE GROUND KITS M.HANGERS N.HOISTING GRIPS O.BTS EQUIPMENT 2.THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THE COMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCH MATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB-FRAME FOR PLATFORM, ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDING WIRES, COPPER-CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS AND DISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER, CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORE DRILLING, SLEEPERS AND RUBBER MATTING, REBAR, CONCRETE CAISSONS, PADS AND/OR AUGER MOUNTS, MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES AND ALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TO THE DRAWINGS AND SPECIFICATIONS. IT IS THE POSITION OF T-MOBILE TO APPLY FOR PERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIRED PERMITS. 3.ALL WORK SHALL CONFORM TO ALL CURRENT APPLICABLE FEDERAL, STATE, AND LOCAL CODES, INCLUDING ANSI/EIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTION SPECIFICATIONS. 4.CONTRACTOR SHALL CONTACT LOCAL 811 FOR IDENTIFICATION OF UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION. 5.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIRED INSPECTIONS. 6.ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, AND SITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALL DISCREPANCIES REPORTED TO THE ENGINEER. 7.DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS. 8.DETAILS SHOWN ARE TYPICAL; SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESS OTHERWISE NOTED. 9.THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 10.CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDED FOR STABILITY ARE INSTALLED. THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING, ANCHOR BOLTS, ETC. 11.CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDS DRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCING WORK. 12.INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING OR NONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE T-MOBILE REP PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH REMEDIAL ACTION SHALL REQUIRE WRITTEN APPROVAL BY THE T-MOBILE REP PRIOR TO PROCEEDING. 13.EACH CONTRACTOR SHALL COOPERATE WITH THE T-MOBILE REP, AND COORDINATE HIS WORK WITH THE WORK OF OTHERS. 14.CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THIS PROJECT TO MATCH EXISTING PRE-CONSTRUCTION CONDITIONS TO THE SATISFACTION OF THE T-MOBILE CONSTRUCTION MANAGER. 15.ALL CABLE/CONDUIT ENTRY/EXIT PORTS SHALL BE WEATHERPROOFED DURING INSTALLATION USING A SILICONE SEALANT. 16.WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET, CONTRACTOR SHALL NOTIFY THE T-MOBILE REP AND ENGINEER OF RECORD IMMEDIATELY. 17.CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETE AND CURRENT SET OF DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT. 18.CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OF EACH DAY. 19.CONTRACTOR SHALL COORDINATE WORK SCHEDULE WITH AMERICAN TOWER CORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OF OTHER OCCUPANTS OF THE FACILITY. 20.CONTRACTOR SHALL FURNISH T-MOBILE AND AMERICAN TOWER CORPORATION (ATC) WITH A PDF MARKED UP AS-BUILT SET OF DRAWINGS UPON COMPLETION OF WORK. 21.PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDED SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR WILL INSTALL ALL ITEMS PROVIDED. 22.PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR. ALL REQUIRED PERMITS NOT OBTAINED BY T-MOBILE MUST BE OBTAINED, AND PAID FOR, BY THE CONTRACTOR. 23.CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH T-MOBILE SPECIFICATIONS AND REQUIREMENTS. 24.CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO T-MOBILE FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. 25.ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS AND LOCATED ACCORDING TO T-MOBILE SPECIFICATIONS, AND AS SHOWN IN THESE PLANS. 26.THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 27.CONTRACTOR SHALL NOTIFY T-MOBILE REP A MINIMUM OF 48 HOURS IN ADVANCE OF POURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS OR SEALING ANY WALL, FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW AND APPROVAL. 28.CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY INCLUDING COMPLIANCE WITH ALL APPLICABLE OSHA STANDARDS AND RECOMMENDATIONS AND SHALL PROVIDE ALL NECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICES SUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING, TRENCH BOXES/SLOPING, BARRIERS, ETC. 29.THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES AND SUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD. ANY DAMAGE CAUSED BY NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES, OR BY THE ELEMENTS DUE TO NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HIS WORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HIS EXPENSE TO THE OWNER'S SATISFACTION. 30.ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNER BY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIP SHALL BE SUBJECT TO THE APPROVAL OF THE T-MOBILE REP. ANY WORK FOUND BY THE T-MOBILE REP TO BE OF INFERIOR QUALITY AND/OR WORKMANSHIP SHALL BE REPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL IS OBTAINED. 31.IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OF MATERIALS LISTED HEREINAFTER BY MANUFACTURER’S NAMES AND/OR MANUFACTURER’S CATALOG NUMBER SHALL BE PROVIDED BY THESE MANUFACTURERS AS SPECIFIED. 32.T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED-UP AT THE T-MOBILE WAREHOUSE, NO LATER THAN 48HR AFTER BEING NOTIFIED INSURED, STORED, UNCRATE, PROTECTED AND INSTALLED BY THE CONTRACTOR WITH ALL APPURTENANCES REQUIRED TO PLACE THE EQUIPMENT IN OPERATION, READY FOR USE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP. 33.T-MOBILE OR HIS ARCHITECT/ENGINEER RESERVES THE RIGHT TO REJECT ANY EQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITH THE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THE EQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TO T-MOBILE OR THEIR ARCHITECT/ENGINEER. SPECIAL CONSTRUCTION ANTENNA INSTALLATION NOTES: 1.WORK INCLUDED: A.ANTENNA AND COAXIAL CABLES ARE FURNISHED BY T-MOBILE UNDER A SEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA INSTALLATION CONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS. ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF PERSONNEL. B.INSTALL ANTENNAS AS INDICATED ON DRAWINGS AND T-MOBILE SPECIFICATIONS. C.INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS. D.INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE. E.CONTRACTOR SHALL PROVIDE FOUR (4) SETS OF SWEEP TESTS USING ANRITZU-PACKARD 8713B RF SCALAR NETWORK ANALYZER. SUBMIT FREQUENCY DOMAIN REFLECTOMETER(FDR) TESTS RESULTS TO THE PROJECT MANAGER. SWEEP TESTS SHALL BE AS PER ATTACHED RFS "MINIMUM FIELD TESTING RECOMMENDED FOR ANTENNA AND HELIAX COAXIAL CABLE SYSTEMS" DATED 10/5/93. TESTING SHALL BE PERFORMED BY AN INDEPENDENT TESTING SERVICE AND BE BOUND AND SUBMITTED WITHIN ONE WEEK OF WORK COMPLETION. F.INSTALL COAXIAL CABLES AND TERMINATING BETWEEN ANTENNAS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALL CONNECTIONS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. TERMINATE ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OF ENTRY PORT LOCATION UNLESS OTHERWISE STATED. G.ANTENNA AND COAXIAL CABLE GROUNDING: 2.ALL EXTERIOR #6 GREEN GROUND WIRE "DAISY CHAIN" CONNECTIONS ARE TO BE WEATHER SEALED WITH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT #221213 OR EQUAL. 3.ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF COAXIAL CABLE (NOT WITHIN BENDS) ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESE CONSTRUCTION DRAWINGS SHALL BE COMMUNICATED TO ATC ENGINEERING IMMEDIATELY FOR CORRECTION OR RE-DESIGN. FAILURE TO COMMUNICATE DIRECTLY WITH ATC ENGINEERING OR ANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIOR APPROVAL FROM ATC ENGINEERING SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. <<w=175; h=175; n=BLANK - SIG; a=11>> SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.C-101 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 DETAILED SITE PLAN SITE PLAN NOTES: 1.THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. 2.ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL PROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN. BEFORE UTILIZING EXISTING CABLE SUPPORTS, COAX PORTS, INSTALLING NEW PORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS. 3.NO ELECTRICAL SCOPE IS INCLUDED IN THIS PROJECT. PROPOSED CABLE NOTES: 1.ESTIMATED LENGTH OF PROPOSED CABLE IS 158'. ESTIMATED LENGTH OF CABLE WAS PROVIDED BY CUSTOMER OR CALCULATED BY ADDING THE RAD CENTER AND THE DISTANCE FROM THE SHELTER ENTRY PLATE TO THE TOWER (ALONG THE ICE BRIDGE) AND A SAFETY FACTOR MEASUREMENT OF 15% (OF THE TWO PREVIOUS VALUES), CDS DEFER TO GREATEST CABLE LENGTH. 2.ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTING CABLES AND IN ACCORDANCE WITH STRUCTURAL ANALYSIS. IF ADEQUATE SPACE EXISTS, ROUTE CABLES THROUGH ENTRY PORT HOLE, UP INSIDE OF MONOPOLE, AND THROUGH EXIT PORT HOLE. IF ROUTING OUTSIDE THE MONOPOLE, ATTACH CABLES USING STAND-OFF ADAPTERS MOUNTED TO TOWER USING STAINLESS STEEL BANDING. ADEQUATELY SECURE CABLES USING EITHER APPROPRIATELY SIZED STAINLESS STEEL SNAP-INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE MANUFACTURER. 1 DETAILED SITE PLAN GRAPHIC SCALE ( IN FEET ) 1 UNIT = 5 FEET 52.505 LEGEND AUTOMATIC TRANSFER SWITCHATS DISCONNECTD ELECTRICALE FIBERF BOLLARDB GENERATOR RECEPTACLEG HAND HOLE, VAULTHH, V ICE BRIDGEIB KENTROX BOXK GENERATORGEN METERM LIGHTING CONTROLLC PULL BOXPB POWER POLEPP TELCOT TRANSFORMERTRN CHAINLINK FENCE GROUNDING TEST WELL CELL SITE CABINETCSC PROPOSED (3) HCS 2.0 TRUNK CABLE (SEE PROPOSED CABLE NOTES THIS PAGE FOR LENGTH AND ROUTING GUIDELINES) (2) 0.41" CNT-400, (16) 7/8" COAX, & (2) HCS 2.0 TRUNK CABLE (TO BE REMOVED) (MODIFIED AS REQUIRED FOR UPGRADE FROM 6794A_SR_U21 TO 56790EZ_SR_4SEC CONFIGURATION) 1 R-601 2 C-102 <<w=175; h=175; n=BLANK - SIG; a=11>> SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.C-102 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 DETAILED EQUIPMENT PLAN T-MOBILE CM APPROVAL REQUIRED BEFORE INSTALLING CABINETS. 1 EXISTING GROUND EQUIPMENT LAYOUT 2 PROPOSED GROUND EQUIPMENT LAYOUT SITE PLAN NOTES: 1.CONTRACTOR TO VERIFY THERE IS NO LIVE AAV FIBER RUNNING THROUGH EXISTING DEAD EQUIPMENT. IF SO, THIS WILL NEED TO BE RERUN THROUGH CONDUIT PRIOR TO REMOVING DEAD 2G (6201 CABS) EQUIPMENT. 2.ALL OPEN PORTS NEED TO BE SEALED / WEATHERPROOFED PROPERLY 3.ALL UNNEEDED / EXCESS EQUIPMENT AND GARBAGE TO BE REMOVED FROM EQUIPMENT AREA. DISPOSE OF MATERIALS PROPERLY OFF SITE. GRAPHIC SCALE ( IN FEET ) 1 UNIT = 5 FEET 2.505 5 GRAPHIC SCALE ( IN FEET ) 1 UNIT = 5 FEET 2.505 5 (2) 0.41" CNT-400, (16) 7/8" COAX, & (2) HCS 2.0 TRUNK CABLE (TO BE REMOVED) (TO BE REMOVED) PROPOSED (3) HCS 2.0 TRUNK CABLE PROPOSED JUNCTION BOX <<w=175; h=175; n=BLANK - SIG; a=11>> SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.C-201 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 TOWER ELEVATION 2 C-401 PROPOSED T-MOBILE EQUIPMENT PROPOSED T-MOBILE RAD CENTER @ 85' PER MOUNT ANALYSIS COMPLETED BY POD, DATED 3/13/2023, THE EXISTING MOUNT CAN ADEQUATELY SUPPORT THE PROPOSED LOADING. TOWER NOTE: 1.IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONFIRM WITH THE PROJECT MANAGER THAT THEY HAVE THE MOST RECENT VERSION OF THE STRUCTURAL ANALYSIS BEFORE COMMENCING WORK. EXISTING AND PROPOSED TOWER APPURTENANCES, MOUNTS, AND ANTENNAS ARE SHOWN BASED ON THE STRUCTURAL ANALYSIS. 2.WHERE APPLICABLE, ALL NEW ANTENNAS, EQUIPMENT, MOUNTS, CABLING, ETC. SHALL BE PAINTED/SOCKED TO MATCH EXISTING EQUIPMENT IN ACCORDANCE WITH FAA, JURISDICTION, AND/OR OTHER LOCAL REQUIREMENTS. 3.ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTING CABLES AND IN ACCORDANCE WITH STRUCTURAL ANALYSIS. IF ADEQUATE SPACE EXISTS, ROUTE CABLES THROUGH ENTRY PORT HOLE, UP INSIDE OF MONOPOLE, AND THROUGH EXIT PORT HOLE. IF ROUTING OUTSIDE THE MONOPOLE, ATTACH CABLES USING STAND-OFF ADAPTERS MOUNTED TO TOWER USING STAINLESS STEEL BANDING. ADEQUATELY SECURE CABLES USING EITHER APPROPRIATELY SIZED STAINLESS STEEL SNAP-INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE MANUFACTURER. 4.TOWER ELEVATIONS ARE MEASURED FROM TOP OF BASE PLATE TO MATCH STRUCTURAL ANALYSIS. ELEVATIONS DO NOT REFLECT TRUE ABOVE GROUND LEVEL (A.G.L.) 5. TOWER ELEVATION DEPICTION MAY NOT REFLECT ALL EQUIPMENT INCLUDED IN STRUCTURAL ANALYSIS. REFER TO STRUCTURAL ANALYSIS FOR FULL TOWER LOADING.2 PROPOSED TOWER ELEVATION SCALE: N.T.S.1 EXISTING TOWER ELEVATION SCALE: N.T.S. (TO BE REMOVED OR RELOCATED TO SPRINT MOUNT) 1 C-401 (TO BE REMOVED BY TMO) EXISTING T-MOBILE RAD CENTER @ 65' (2) 0.41" CNT-400, (16) 7/8" COAX, & (2) HCS 2.0 TRUNK CABLE (TO BE REMOVED) PROPOSED (3) HCS 2.0 TRUNK CABLE <<w=175; h=175; n=BLANK - SIG; a=11>> SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.C-401 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 ANTENNA INFORMATION & SCHEDULE 1 C-501 CONTRACTOR SHALL RE-ORIENT ANTENNA MOUNT(s) AS NECESSARY TO ACHIEVE PROPOSED ANTENNA AZIMUTHS 1 EXISTING ANTENNA PLAN @ 65' SCALE: N.T.S.2 FINAL ANTENNA PLAN @ 85' SCALE: N.T.S. 3 EQUIPMENT SCHEDULES CABLE LENGTHS FOR JUMPERS JUNCTION BOX TO RRU: 15' RRU TO ANTENNA: 10' 1.CONFIRM WITH T-MOBILE REP FOR APPLICABLE UPDATES/REVISIONS AND MOST RECENT RFDS FOR NSN CONFIGURATION (CONFIG). GC TO CAP ALL UNUSED PORTS. 2.CONFIRM SPACING OF PROPOSED EQUIP DOES NOT CAUSE TOWER CONFLICTS NOR IMPEDE TOWER CLIMBING PEGS. NOTES STATUS ABBREVIATIONS RMV: TO BE REMOVED : TO REMAIN REL: TO BE RELOCATED ADD: TO BE ADDED FINAL ANTENNA SCHEDULE LOCATION ANTENNA SUMMARY NON ANTENNA SUMMARY SECTOR RAD AZ POS ANTENNA BAND MECH/ELEC D-TILT STATUS ADDITIONAL TOWER MOUNTED EQUIPMENT STATUS ALPHA 85'0° A1 REL AHFII REL ADD A2 AEHC N2500 0°ADD -- BETA 85'120° B1 REL AHFII REL ADD B2 AEHC N2500 0°ADD -- GAMMA 85'240° C1 REL AHFII REL ADD C2 AEHC N2500 0°ADD -- DELTA 85'60°D1 REL AHFII REL ADD EXISTING ANTENNA SCHEDULE LOCATION ANTENNA SUMMARY NON ANTENNA SUMMARY SECTOR RAD AZ POS ANTENNA BAND MECH/ELEC D-TILT STATUS ADDITIONAL TOWER MOUNTED EQUIPMENT STATUS REL REL RMV RMV RMV REL REL RMV RMV RMV REL REL RMV RMV RMV REL REL RMV RMV RMV EXISTING FIBER DISTRIBUTION/OVP BOX EXISTING CABLING SUMMARY MODEL NUMBER STATUS CABLE QTY, SIZE, TYPE STATUS REL RMV FINAL FIBER DISTRIBUTION / OVP BOX FINAL CABLING SUMMARY MODEL NUMBER STATUS CABLE QTY, SIZE, TYPE STATUS REL HELIAX FIBERFEED 12 RRU PENDANT CONNECT ADD (3) HCS 2.0 TRUNK CABLE ADD PROPOSED AHFII RRU (1 PER SECTOR) (TYP. 4) PER MOUNT ANALYSIS COMPLETED BY POD, DATED 3/13/2023, THE EXISTING MOUNT CAN ADEQUATELY SUPPORT THE PROPOSED LOADING. PROPOSED AEHC ANTENNA (1 PER SECTOR) (TYP. 3) PROPOSED PENDANT (TYP. 1) (TO BE REMOVED) (TO BE RELOCATED TO MOUNT @ 85') (1 PER SECTOR) (TYP. 4) (TO BE RELOCATED TO MOUNT @ 85') (1 PER SECTOR) (TYP. 4) (TO BE REMOVED) (1 PER SECTOR) (TYP.4) (TO BE REMOVED) (1 PER SECTOR) (TYP.4) (TO BE RELOCATED TO MOUNT @ 85') (TYP. 2) (TO BE REMOVED) (1 PER SECTOR) (TYP. 4) A2 B2 C2AZ.=ALPHA0°AZ.= GAM M A 240 ° AZ . = BE T A 12 0 ° 2 C-501 <<w=175; h=175; n=BLANK - SIG; a=11>> SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.C-501 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 CONSTRUCTION DETAILS PROPOSED RRU MOUNT LOCATION (OPTION 2) (MOUNT PER MANUFACTURER'S SPECS) (ENSURE THAT BRACKET DOES NOT CONFLICT WITH EXISTING OR PROPOSED EQUIPMENT) PROPOSED RRU MOUNT LOCATION (OPTION 1) (MOUNT PER MANUFACTURER'S SPECS) (ENSURE THAT BRACKET DOES NOT CONFLICT WITH EXISTING OR PROPOSED EQUIPMENT) 2 PROPOSED RRU MOUNTING DETAIL - TYPICAL SCALE: N.T.S. PROPOSED ANTENNA 1 PROPOSED 5G ANTENNA MOUNTING DETAIL - TYPICAL SCALE: N.T.S. <<w=175; h=175; n=BLANK - SIG; a=11>> SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.E-501 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 GROUNDING DETAILS NOTES: 1.THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS. SLIGHT ADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THE CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THE CONSTRUCTION MANAGER OF ANY CONFLICTS. 2.SITE GROUNDING SHALL COMPLY WITH T-MOBILE GROUNDING STANDARDS, LATEST EDITION, AND COMPLY WITH T-MOBILE GROUNDING CHECKLIST, LATEST VERSION. WHEN NATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN. PROPOSED CONNECTOR AND WEATHERPROOFING KIT 1 TYPICAL ANTENNA GROUNDING DIAGRAM SCALE: N.T.S. PROPOSED ANTENNA PROPOSED JUMPER PROPOSED WEATHERPROOFING KIT 2 E-501 3 E-501 GROUND BAR MOUNTED NEAR/BELOW ANTENNA (TO BE INSTALLED IF REQUIRED) #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION ANTENNA CABLE TO CABINET (TYP.) PROPOSED CABLE GROUND KIT PROPOSED #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION TO PROPOSED RRU GROUND LUG (TYP.) DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT (ANDREW PART NUMBER 221213) AND INSTALL/TAPE PER MANUFACTURER'S SPECIFICATIONS. 2 CABLE GROUND KIT CONNECTION DETAIL SCALE: N.T.S. TO ANTENNA TO EQUIPMENT TO GROUND BAR ANTENNA CABLE 2 1/2"Ø MAX GROUNDING KIT PER CABLE MANUFACTURER'S RECOMMENDATIONS (ANDREW OR APPROVED EQUAL) #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) GROUND KIT NOTES: 1. 2. 1/4" X 4" X 6" GROUND BAR (ERICO P/N: EGBA14406CC OR EQUAL) 3 TOWER GROUND BAR DETAIL SCALE: N.T.S. GROUND BAR NOTES: 1.GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS, WASHERS, ETC. EXCEPT THE STRUCTURAL MOUNTING MEMBER(S). 2.GROUND BAR TO BE BONDED DIRECTLY TO TOWER. 3/8" SS LOCK WASHER (EACH SIDE) TWO-HOLE LUG, TO BE USED WITH #2 AWG BCW (LOWER TOWER GROUND BAR ONLY) 3/8" X 1-1/2" SS BOLT (EACH SIDE) SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.R-601 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 SUPPLEMENTAL NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.R-602 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 SUPPLEMENTAL NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.R-603 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 SUPPLEMENTAL NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.R-604 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 SUPPLEMENTAL NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.R-605 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 SUPPLEMENTAL NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.R-606 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 SUPPLEMENTAL NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. DC IN + - + -EAC SIN SOUT FAN STATUS SEI1 SEI2EIF3EIF1EIF2 RESET SERVICE LMP EIF4 NOKIA 474767A ASIL RESET SERVICE DC IN 48V (CLAMPS) EAC (HDMI)SIN (HDMI) SOUT (HDMI) SEI1 (OSFP) SEI2 (OSFP) EIF3 (SFP) EIF1 (SFP) EIF2 (SFP) LMP/EIF4 GROUND (DUAL-HOLE 2x M5)14.84"1.9"8.62" MANUFACTURER:NOKIA MODEL:ASIL CONTROLLER CARD (474767A) DIMENSIONS:1.9" X 8.62" X 14.84" WEIGHT:6.8 LBS SCALE: N.T.S.1 ASIL DETAIL MANUFACTURER:NOKIA MODEL:ABIO INTERFACE WEIGHT:5.84 LBS DIMENSIONS:0.98"x8.62"x14.33" ABIO DETAIL2 SCALE: N.T.S. 6X24 HCS 4AWG W/ PENDANT3 SCALE: N.T.S. SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.R-607 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 SUPPLEMENTAL OPT1 OPT2 OPT3OPT4 UNIT OPT1 OPT2 OPT3 OPT4 RET DC IN V DC -48V I kw 60a A XXX XX SCALE: N.T.S.1 34117 - AIRSCALE MAA B41 AEHC NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. MANUFACTURER:COMMSCOPE MODEL:FE-16148-OVP-B12 WEIGHT:15.2 LBS DIMENSIONS:14"x16"x 8"16"14" (6) JUMPER (.5" TO .7") (2) POWER (.9" TO 1.3") HCS CABLE (1.1" TO 1.7") (2) ALARM/GROUND (.2") 8" SCALE: N.T.S.3 33706 - HCS 2.0 JCT BOX 60KA34577 - AHFII - 4T4R DUAL-BAND RADIO2SCALE: N.T.S. SHEET NUMBER:REVISION:Copyright © 2023 ATC IP LLC, All Rights Reserved.R-608 SEAL: DESCRIPTIONREV.DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 F-6274 THE USE AND PUBLICATION OF THESE DRAWINGS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND ADVISE AMERICAN TOWER OR THE SPECIFIED CARRIER OF ANY DISCREPANCIES. ANY PRIOR ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST VERSION. ATC PROJ. #: SANDY LK-CINGULAR #3423 14185798_G3 DA01278BCUST. #: 309374 636 SANDY LAKE ROAD COPPELL,TX 75019 ATC SITE NUMBER: SITE ADDRESS: T-MOBILE SITE NAME: DESCRIPTIONREV.DATEBY CUST. ID: 309374 COPPELL #2 (CO-LOCATE) SANDY LK-CINGULAR #3423 ATC SITE NAME: 0 0 FOR CONSTRUCTION JBW 04/11/23 SUPPLEMENTAL NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. PLEASE REFERENCE THE MOUNT ANALYSIS REPORT FOR COMPLETE MOUNT ANALYSIS CALCULATIONS AND DETAILS. SUPPLEMENTAL PAGES INCLUDED IN THE CONSTRUCTION DRAWINGS ARE FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TO VERYIFY THEY HAVE THE MOST RECENT MOUNT ANALYSIS PRIOR TO CONTRUCTION. 1 MOUNT ANALYSIS