AdminApproval7-15-20249101581215361449112118AC HOTELBY MARRIOT5 STORY130 ROOM HOTELSITE AREA = 2.657 ACBUILDING FOOTPRINT = 17,050 SQ. FT.POOL18.0'9.0'18.0'9.0'9.0'9.0'18.0'9.0'24.0'29.0'
9.0'9.0'18.0'18.0'24.0'9.0'18.0'9.0'18.0'9.0'18.0'
9.0'
9.0'18.0'18.0'9.0'
9.0'18.0'9.0'18.0'MECHANICAL/ELECTRICAL(RISER ROOM)18.0'
24.0'OUTDOORPLAZAPORTECOCHERE6.0'5.0'LOADING ZONE5.0'
12.0'6.0'5.0'
5.0'5.0'5.0'
24.0'
18.0'18.00'35.3'99.1'43.7'PROP. TRANSFORMERPROP FIRE HYDRANTPROP FIREHYDRANTPROP FIREHYDRANTPROP FDCPROPDUMPSTERSPROP 4' ORNAMENTALIRON FENCING.REFERENCELANDSCAPE PLAN.VARIABLE WIDTHMUTUAL ACCESS ESMT.DOC. NO. 20070445910O.P.R.D.C.T.R54.0'R24
.
0
'R24.0'R
2
4
.
0
'
R
3
0
.
0
'R30.0'R30.0'R24.0'R24.0'R54.0'R30.0'R54.0'R48.0'R54.0'R30.0'LEGENDPROPERTY LINEPROPOSED BUILDINGVICINITY MAP1" = 3000'ENGINEER:QUIDDITY ENGINEERING, LLC2805 DALLAS PARKWAY, SUITE 600PLANO, TX 75093TEL (972) 265-7174CONTACT: ALEK W. STRIMPLE, PEASTRIMPLE@QUIDDITY.COMLANDSCAPE ARCHITECT:EVERGREEN DESIGN GROUP15305 DALLAS PKWY., STE 300ADDISON, TX 75001TEL (800) 680-6630 x14CONTACT: STEPHEN SALESSTEPHEN@EVERGREENDESIGNGROUP.COMOWNER:FRISCO 5 VENTURES LP4055 VALLEY VIEW LN, SUITE 500DALLAS, TEXAS 75244TEL (972) 600-8162CONTACT: DK PatelDK@WHITESTONEHM.COMARCHITECT:TYPE-SIXDEVELOPMENT SERVICES, LLC910 SOUTH MAIN STREET, SUITE 150GRAPEVINE, TEXAS 76054TEL (501) 416-9826CONTACT: CONNOR WALKER, AIACONNOR.WALKER@TYPE-SIX.COMPROJECTLOCATION1.THIS PROPERTY WILL BE PLATTED TO PROVIDE EASEMENTS AND FIRE LANES PRIOR TOANY DEVELOPMENT.2.A VARIANCE SHALL BE REQUIRED FOR THE FOLLOWING:·TO ALLOW A 5' LANDSCAPE BUFFER ALONG THE SOUTHERN PROPERTY LINE.·TO ALLOW FOR A SINGLE LOADING SPACE ON THE WEST SIDE OF THE BUILDING.PD CONDITIONSK:\16189\16189-0003-00 Coppell Hilton Garden Inn\2 Design Phase\CAD\Exhibits\PD ZONING\DETAIL SITE PLAN.dwg Jul 15,2024 - 1:37pm mtuvdenTexas Board of Professional Engineers and Land Surveyors Registration Nos. F-23290 & 10046100
2805 Dallas Parkway, Suite 600 Plano, TX 75093 972.488.3880
AC HOTEL BY MARRIOTT
1543 S BELT LINE RD - COPPELL, TX, 75093OF No.REVISIONSHEET NO.JOB NO.:
DESIGNED BY.:ZA
CHECKED BY:AWSDATE:
DRAWN BY:OT
JULY 2024
16189-0003-03
APP.DateTEXAS811 NOTIFICATION SYSTEMCALL BEFORE YOU DIG!!!www.texas811.orgTexas811 or 1-800-545-6005CONTRACTOR TO VERIFY ELEVATION AND LOCATIONOF ALL EXISTING UTILITIES PRIOR TOCOMMENCEMENT OF ANY NEW CONSTRUCTIONDETAIL SITE PLAN11SITE PLANAC HOTELPD-221R3R5-HCLOT 1R-8RBLK C DUKE LESLEY (AC BY MARRIOTT)Not intended for construction,bidding or permit purposes.INTERIM REVIEWALEK W. STRIMPLE, P.E.142586Date:P.E. Serial No.:Engineer:APRIL 2024Not intended for construction,bidding or permit purposes.INTERIM REVIEWALEK W. STRIMPLE, P.E.142586Date:P.E. Serial No.:Engineer:APRIL 2024Not intended for construction,bidding or permit purposes.INTERIM REVIEWALEK W. STRIMPLE, P.E.142586Date:P.E. Serial No.:Engineer:FEBRUARY 2023Not intended for construction,bidding or permit purposes.INTERIM REVIEWALEK W. STRIMPLE, P.E.142586Date:P.E. Serial No.:Engineer:FEBRUARY 2023Not intended for construction bidding or permit purposes.INTERIM REVIEWALEK W. STRIMPLE, P.E.142586Date:P.E. Serial No.:Engineer:JANUARY 2023Not intended for construction bidding or permit purposes.INTERIM REVIEWALEK W. STRIMPLE, P.E 142586Date:P.E. Serial No.:Engineer:DECEMBER 2022ALEK W. STRIMPLE142586JANUARY 2022INTERIM REVIEWNot intended for construction bidding or permit purposes.P.E. Serial No.:Date:Engineer:ALEK W. STRIMPLE142586JANUARY 2022INTERIM REVIEWNot intended for construction bidding or permit purposes.P.E. Serial No.:Date:Engineer:01/24/20 02/04/20 03/15/20 03/23/20 03/24/20 05/13/20 05/14/20 05/13/20 05/26/20 06/06/20 06/14/20 07/14/20 07/15/20 12/07/20 1/11/20 02/10/20 08/25/20 09/06/20 09/27/20 10/13/20 10/25/20 04/19/20 07/02/202407/11/2024Administratively Approved on 07/15/2024
1QV1QV1QV3QS1QV1QV1QS1QV1QV2QV1QV1LI1QV1QV2QV77MP50IN35MP54IN41MP51AG33AG1LI3CC1QS5LC9SA6LC12SA5EC3CS3CS6HP3CS6RA3CS7SA9LF6BR6SA9MPTURFTURFTURFTURFTURFTURFTURFTURFTURFTURFTURFTURFTURFTURFTURF4CI1CC1CC3CC1CC1CC12IS6IS9IS3IS91015812153614491121186HP7EC7HP2RA6LC6SA6HP6LF6BR7LF6BR6SA1QS6BR3CS4EC6RA4HP6EC3HP3CS5EC6BR6LF6EC6BR6LF4EC1CC5RA5LF4CI3LILANDSCAPE CALCULATIONSTOTAL SITE AREA:115,739 SFBUILDING:17,753 SFNON-EXEMPT PARKING AREA:46,451 SFOPEN SPACE:30,673 (26.5%)INTERIOR LANDSCAPINGLANDSCAPE REQUIRED:5,574 SF (12% OF NON-EXEMPT AREA)LANDSCAPE PROVIDED:5,578 SF (12%)TREES REQUIRED IN REQUIRED LANDSCAPE:14 TREES (1 TREE PER 400 SF)TREES PROVIDED:19 TREESNON-VEHICULAR OPEN SPACELANDSCAPE REQUIRED:14,698 SF (15% OF SITE NOT COVEREDBY BUILDING)LANDSCAPE PROVIDED:15,049 SF (15.4%)TREES REQUIRED:6 TREES (1 PER 2,500 SF)TREES PROVIDED:5 CANOPY TREES, 5 ACCENT TREES (3:1)Scale 1" = 20'10'40'20'0'NO EXISTING TREESON SITEIRRIGATION CONCEPT1.AN AUTOMATIC IRRIGATION SYSTEM SHALL BE INSTALLED AND OPERATIONAL BY THE TIME OF FINALINSPECTION. THE ENTIRE IRRIGATION SYSTEM SHALL BE INSTALLED BY A LICENSED AND QUALIFIEDIRRIGATION CONTRACTOR.2.THE IRRIGATION SYSTEM WILL OPERATE ON POTABLE WATER, AND THE SYSTEM WILL HAVE APPROPRIATEBACKFLOW PREVENTION DEVICES INSTALLED TO PREVENT CONTAMINATION OF THE POTABLE SOURCE.3.ALL NON-TURF PLANTED AREAS SHALL BE DRIP IRRIGATED. SODDED AND SEEDED AREAS SHALL BE IRRIGATEDWITH SPRAY OR ROTOR HEADS AT 100% HEAD-TO-HEAD COVERAGE.4.ALL PLANTS SHARING SIMILAR HYDROZONE CHARACTERISTICS SHALL BE PLACED ON A VALVE DEDICATED TOPROVIDE THE NECESSARY WATER REQUIREMENTS SPECIFIC TO THAT HYDROZONE.5.THE IRRIGATION SYSTEM SHALL BE DESIGNED AND INSTALLED, TO THE MAXIMUM EXTENT POSSIBLE, TOCONSERVE WATER BY USING THE FOLLOWING DEVICES AND SYSTEMS: MATCHED PRECIPITATION RATETECHNOLOGY ON ROTOR AND SPRAY HEADS (WHEREVER POSSIBLE), RAIN SENSORS, AND MULTI-PROGRAMCOMPUTERIZED IRRIGATION CONTROLLERS FEATURING SENSORY INPUT CAPABILITIES.6.IRRIGATION PLAN SHALL BE PROVIDED WITH THE BUILDING PERMIT.THE CONTRACTOR SHALL INSTALL ROOT BARRIERS NEAR ALL NEWLY-PLANTED TREES THAT ARE LOCATED WITHINFIVE (5) FEET OF PAVING OR CURBS. ROOT BARRIERS SHALL BE "CENTURY" OR "DEEP-ROOT" 24" DEEP PANELS (OREQUAL). BARRIERS SHALL BE LOCATED IMMEDIATELY ADJACENT TO HARDSCAPE. INSTALL PANELS PERMANUFACTURER'S RECOMMENDATIONS. UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR USE ROOTBARRIERS OF A TYPE THAT COMPLETELY ENCIRCLE THE ROOTBALL.ROOT BARRIERSMULCHESAFTER ALL PLANTING IS COMPLETE, CONTRACTOR SHALL INSTALL 3" THICK LAYER OF 1-1/2" SHREDDED WOODMULCH, NATURAL (UNDYED), OVER LANDSCAPE FABRIC IN ALL PLANTING AREAS (EXCEPT FOR TURF AND SEEDEDAREAS). CONTRACTOR SHALL SUBMIT SAMPLES OF ALL MULCHES TO LANDSCAPE ARCHITECT AND OWNER FORAPPROVAL PRIOR TO CONSTRUCTION. ABSOLUTELY NO EXPOSED GROUND SHALL BE LEFT SHOWING ANYWHEREON THE PROJECT AFTER MULCH HAS BEEN INSTALLED (SUBJECT TO THE CONDITIONS AND REQUIREMENTS OF THE"GENERAL GRADING AND PLANTING NOTES" AND SPECIFICATIONS).GENERAL GRADING AND PLANTING NOTES1.BY SUBMITTING A PROPOSAL FOR THE LANDSCAPE PLANTING SCOPE OF WORK, THE CONTRACTORCONFIRMS THAT HE HAS READ, AND WILL COMPLY WITH, THE ASSOCIATED NOTES, SPECIFICATIONS, ANDDETAILS WITH THIS PROJECT.2.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL EXISTING VEGETATION (EXCEPT WHERENOTED TO REMAIN).3.IN THE CONTEXT OF THESE PLANS, NOTES, AND SPECIFICATIONS, "FINISH GRADE" REFERS TO THE FINALELEVATION OF THE SOIL SURFACE (NOT TOP OF MULCH) AS INDICATED ON THE GRADING PLANS.a.BEFORE STARTING WORK, THE LANDSCAPE CONTRACTOR SHALL VERIFY THAT THE ROUGH GRADESOF ALL LANDSCAPE AREAS ARE WITHIN +/-0.1' OF FINISH GRADE. SEE SPECIFICATIONS FOR MOREDETAILED INSTRUCTION ON TURF AREA AND PLANTING BED PREPARATION.b.CONSTRUCT AND MAINTAIN FINISH GRADES AS SHOWN ON GRADING PLANS, AND CONSTRUCT ANDMAINTAIN SLOPES AS RECOMMENDED BY THE GEOTECHNICAL REPORT. ALL LANDSCAPE AREASSHALL HAVE POSITIVE DRAINAGE AWAY FROM STRUCTURES AT THE MINIMUM SLOPE SPECIFIED INTHE REPORT AND ON THE GRADING PLANS, AND AREAS OF POTENTIAL PONDING SHALL BE REGRADEDTO BLEND IN WITH THE SURROUNDING GRADES AND ELIMINATE PONDING POTENTIAL.c.THE LANDSCAPE CONTRACTOR SHALL DETERMINE WHETHER OR NOT THE EXPORT OF ANY SOIL WILLBE NEEDED, TAKING INTO ACCOUNT THE ROUGH GRADE PROVIDED, THE AMOUNT OF SOILAMENDMENTS TO BE ADDED (BASED ON A SOIL TEST, PER SPECIFICATIONS), AND THE FINISH GRADESTO BE ESTABLISHED.d.ENSURE THAT THE FINISH GRADE IN SHRUB AREAS IMMEDIATELY ADJACENT TO WALKS AND OTHERWALKING SURFACES, AFTER INSTALLING SOIL AMENDMENTS, IS 3" BELOW THE ADJACENT FINISHSURFACE, IN ORDER TO ALLOW FOR PROPER MULCH DEPTH. TAPER THE SOIL SURFACE TO MEETFINISH GRADE, AS SPECIFIED ON THE GRADING PLANS, AT APPROXIMATELY 18" AWAY FROM THEWALKS.e.ENSURE THAT THE FINISH GRADE IN TURF AREAS IMMEDIATELY ADJACENT TO WALKS AND OTHERWALKING SURFACES, AFTER INSTALLING SOIL AMENDMENTS, IS 1" BELOW THE FINISH SURFACE OFTHE WALKS. TAPER THE SOIL SURFACE TO MEET FINISH GRADE, AS SPECIFIED ON THE GRADINGPLANS, AT APPROXIMATELY 18" AWAY FROM THE WALKS.f.SHOULD ANY CONFLICTS AND/OR DISCREPANCIES ARISE BETWEEN THE GRADING PLANS,GEOTECHNICAL REPORT, THESE NOTES AND PLANS, AND ACTUAL CONDITIONS, THE CONTRACTORSHALL IMMEDIATELY BRING SUCH ITEMS TO THE ATTENTION OF THE LANDSCAPE ARCHITECT,GENERAL CONTRACTOR, AND OWNER.4.ALL PLANT LOCATIONS ARE DIAGRAMMATIC. ACTUAL LOCATIONS SHALL BE VERIFIED WITH THE LANDSCAPEARCHITECT OR DESIGNER PRIOR TO PLANTING. THE LANDSCAPE CONTRACTOR SHALL ENSURE THAT ALLREQUIREMENTS OF THE PERMITTING AUTHORITY ARE MET (I.E., MINIMUM PLANT QUANTITIES, PLANTINGMETHODS, TREE PROTECTION METHODS, ETC.).a.THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR DETERMINING PLANT QUANTITIES; PLANTQUANTITIES SHOWN ON LEGENDS AND CALLOUTS ARE FOR GENERAL INFORMATION ONLY. IN THEEVENT OF A DISCREPANCY BETWEEN THE PLAN AND THE PLANT LEGEND, THE PLANT QUANTITY ASSHOWN ON THE PLAN (FOR INDIVIDUAL SYMBOLS) OR CALLOUT (FOR GROUNDCOVER PATTERNS)SHALL TAKE PRECEDENCE.b.NO SUBSTITUTIONS OF PLANT MATERIALS SHALL BE ALLOWED WITHOUT THE WRITTEN PERMISSIONOF THE LANDSCAPE ARCHITECT. IF SOME OF THE PLANTS ARE NOT AVAILABLE, THE LANDSCAPECONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT IN WRITING (VIA PROPER CHANNELS).c.THE CONTRACTOR SHALL, AT A MINIMUM, PROVIDE REPRESENTATIVE PHOTOS OF ALL PLANTSPROPOSED FOR THE PROJECT. THE CONTRACTOR SHALL ALLOW THE LANDSCAPE ARCHITECT ANDTHE OWNER/OWNER'S REPRESENTATIVE TO INSPECT, AND APPROVE OR REJECT, ALL PLANTSDELIVERED TO THE JOBSITE. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS FORSUBMITTALS.5.THE CONTRACTOR SHALL MAINTAIN THE LANDSCAPE IN A HEALTHY CONDITION FOR 90 DAYS AFTERACCEPTANCE BY THE OWNER. REFER TO SPECIFICATIONS FOR CONDITIONS OF ACCEPTANCE FOR THESTART OF THE MAINTENANCE PERIOD, AND FOR FINAL ACCEPTANCE AT THE END OF THE MAINTENANCEPERIOD.6.SEE SPECIFICATIONS AND DETAILS FOR FURTHER REQUIREMENTS.PERIMETER LANDSCAPINGFRONTAGE LENGTH (NORTH):276.47 LFTREES REQUIRED:6 TREES (1 PER 50 LF OF FRONTAGE)TREES PROVIDED:1 CANOPY TREE; 15 ACCENT TREES (3:1)(LOW ROOT IMPACT TREES DUE TO WATER EASEMENT)FRONTAGE LENGTH (EAST):341.86 LFTREES REQUIRED:7 TREES (1 PER 50 LF OF FRONTAGE)TREES PROVIDED:7 TREESFRONTAGE LENGTH (SOUTH):230.54 LFTREES REQUIRED:5 TREES (1 PER 50 LF OF FRONTAGE)TREES PROVIDED:5 TREESFRONTAGE LENGTH (WEST):394.47 LFTREES REQUIRED:8 TREES (1 PER 50 LF OF FRONTAGE)TREES PROVIDED:3 CANOPY TREES; 15 ACCENT TREES (3:1)(LOW ROOT IMPACT TREES DUE TO UTILITY EASEMENT)SHRUBS REQUIRED:30" CONTINUOUS HEDGESHRUBS PROVIDED:PROVIDED AS REQUIREDTREESQTYBOTANICAL NAMECOMMON NAMECONTCALSIZECC11CERCIS CANADENSISEASTERN REDBUDCONT.3" CAL MIN7` HT MINLOW ROOT IMPACTCI8CARYA ILLINOINENSISPECANCONT.3" CAL MIN10` HT MINIS30ILEX X ATTENUATA `SAVANNAH`SAVANNAH HOLLYCONT.3" CAL MIN7` HT MINACCENT (3:1); LOW ROOT IMPACTLI5LAGERSTROEMIA INDICACRAPE MYRTLECONT.3" CAL MIN7` HT MINACCENT (3:1)QS6QUERCUS SHUMARDIISHUMARD RED OAKCONT.3" CAL MIN10` HT MINQV14QUERCUS VIRGINIANASOUTHERN LIVE OAKCONT.3" CAL MIN10` HT MINSHRUBSQTYBOTANICAL NAMECOMMON NAMECONTSPACINGSIZEAG84ABELIA X GRANDIFLORAGLOSSY ABELIA3 GAL36" OC30" HT MINBR36BERBERIS THUNBERGII `ROSE GLOW`ROSY GLOW BARBERRY3 GAL36" OC24" HT MINCS18CORTADERIA SELLOANAPAMPAS GRASS3 GAL48" OC24" HT MINEC37EUONYMUS ALATUS `COMPACTUS`COMPACT BURNING BUSH3 GAL36" OC24" HT MINMP162MYRICA PUSILLADWARF WAX MYTRLE3 GAL36" OC30" HT MINHP32HESPERALOE PARVIFLORARED YUCCA3 GAL36" OC24" HT MININ104ILEX VOMITORIA `NANA`DWARF YAUPON3 GAL36" OC30" HT MINLC17LOROPETALUM CHINENSE `HINES PURPLELEAF PLUM DELIGHT` TMPLUM DELIGHT FRINGE-FLOWER3 GAL36" OC24" HT MINLF39LEUCOPHYLLUM FRUTESCENSTEXAS SAGE3 GAL36" OC24" HT MINRA19RHAPHIOLEPIS INDICA `ALBA`WHITE INDIAN HAWTHORN3 GAL36" OC24" HT MINSA46SPIRAEA X BUMALDA `ANTHONY WATERER`ANTHONY WATERER SPIRAEA3 GAL36" OC24" HT MINSOD/SEEDQTYBOTANICAL NAMECOMMON NAMECONTSIZESPACINGSPACINGTURF18,900 SFCYNODON DACTYLONCOMMON BERMUDA GRASSHYDROMULCHPLANT_SCHEDULE1P:\Shared\Projects\2024\AC HOTEL BY MARRIOTT - COPPELL TX - 635 & BELTLINE\AC Marriott - Coppell TX_LP 2024-07-11.dwg Jul 11,2024 - 12:18pm ComputerTexas Board of Professional Engineers and Land Surveyors Registration Nos. F-23290 & 10046100
2805 Dallas Parkway, Suite 600 Plano, TX 75093 972.488.3880
AC HOTEL BY MARRIOTT
1543 S BELT LINE RD - COPPELL, TX, 75093
No.REVISIONSHEET NO.JOB NO.:
DESIGNED BY.:
CHECKED BY:DATE:
DRAWN BY:
APP.Date
(800) 680-663015455 Dallas Pkwy, Ste 600Addison, TX 75001www.EvergreenDesignGroup.comEVERGREENDESIGN GROUPLANDSCAPE PLANLP-1.HIAENSSTE
HCCTTES
A
P
ETSTAIREG
03OF47ETX LRLDRE
CAANDSWEPAESETSSITE PLANAC HOTELPD-221R3R5-HCLOT 1R-8RBLK C DUKE LESLEY (AC BY MARRIOTT)TEXAS811 NOTIFICATION SYSTEMCALL BEFORE YOU DIG!!!www.texas811.orgTexas811 or 1-800-545-6005CONTRACTOR TO VERIFY ELEVATION AND LOCATIONOF ALL EXISTING UTILITIES PRIOR TOCOMMENCEMENT OF ANY NEW CONSTRUCTIONAdministratively Approved on 07/15/2024
PLANT SPACINGSCALE: NTSC4X2X3215674123SHRUB, PERENNIAL, OR ORNAMENTAL GRASS.MULCH, TYPE AND DEPTH PER PLANS. PLACE NOMORE THAN 1" OF MULCH WITHIN 6" OF PLANTCENTER.FINISH GRADE.BACKFILL. AMEND AND FERTILIZE ONLY ASRECOMMENDED IN SOIL FERTILITY ANALYSIS.ROOT BALL.UNDISTURBED NATIVE SOIL.3" HIGH EARTHEN WATERING BASIN.567SHRUB AND PERENNIAL PLANTINGSCALE: NTSB8WEED FABRIC UNDER MULCH.8PLANTING SPECIFICATIONSFINISH GRADE.44321NOTES:1)INSTALL EDGING SO THAT STAKES WILL BE ON INSIDE OF PLANTING BED.2)BOTTOM OF EDGING SHALL BE BURIED A MINIMUM OF 1" BELOW FINISH GRADE.3)TOP OF MULCH SHALL BE 1" LOWER THAN TOP OF EDGING.MULCH, TYPE AND DEPTH PER PLANS.3TAPERED STEEL STAKES.2ROLLED-TOP STEEL EDGING PER PLANS.1DSCALE: NOT TO SCALESTEEL EDGINGTURF (WHERE SHOWN ON PLAN).4PLANT.3MULCH LAYER.2CURB.11432OF MATURE CANOPY24" MIN. TO EDGEDISTANCE PER PLANESCALE: NOT TO SCALEPLANTING AT PARKING AREATREE PLANTINGSCALE: NOT TO SCALEAPLANT CENTER (TYP.)EQUAL EQUALE
Q
U
A
LEDGE OF PLANTING AREAEQUALNOTE: ALL PLANTS SHALL BE PLANTED AT EQUAL TRIANGULAR SPACING (EXCEPT WHERE SHOWN ON PLANS ASINFORMAL GROUPINGS). REFER TO PLANT LEGEND FOR SPACING DISTANCE BETWEEN PLANTS.1) STEP 1: DETERMINE TOTAL PLANTS FOR THE AREA WITH THE FOLLOWING FORMULA:TOTAL AREA / AREA DIVIDER = TOTAL PLANTSPLANT SPACINGAREA DIVIDERPLANT SPACINGAREA DIVIDER6"0.2218"1.958"0.3924"3.4610"0.6030"5.4112"0.8736"7.7915"1.352) STEP 2: SUBTRACT THE ROW (S) OF PLANTS THAT WOULD OCCUR AT THE EDGE OF THE PLANTED AREA WITHTHE FOLLOWING FORMULA: TOTAL PERIMETER LENGTH / PLANT SPACING = TOTAL PLANT SUBTRACTIONEXAMPLE: PLANTS AT 18" O.C. IN 100 SF PLANTING AREA, 40 LF PERIMETERSTEP 1: 100 SF/1.95 = 51 PLANTSSTEP 2: 51 PLANTS - (40 LF / 1.95 = 21 PLANTS) = 30 PLANTS TOTAL5674189111012PREVAILINGWINDSNOTES:1.SCARIFY SIDES OF PLANTING PIT PRIOR TO SETTING TREE.2.REMOVE EXCESS SOIL APPLIED ON TOP OF THE ROOTBALL THATCOVERS THE ROOT FLARE. THE PLANTING HOLE DEPTH SHALL BESUCH THAT THE ROOTBALL RESTS ON UNDISTURBED SOIL, AND THEROOT FLARE IS 2"-4" ABOVE FINISH GRADE.3.FOR B&B TREES, CUT OFF BOTTOM 1/3 OF WIRE BASKET BEFOREPLACING TREE IN HOLE, CUT OFF AND REMOVE REMAINDER OFBASKET AFTER TREE IS SET IN HOLE, REMOVE ALL NYLON TIES,TWINE, ROPE, AND OTHER PACKING MATERIAL. REMOVE AS MUCHBURLAP FROM AROUND ROOTBALL AS IS PRACTICAL.4.REMOVE ALL NURSERY STAKES AFTER PLANTING.5.FOR TREES 36" BOX/2.5" CAL. AND LARGER, USE THREE STAKES ORDEADMEN (AS APPROPRIATE), SPACED EVENLY AROUND TREE.6.STAKING SHALL BE TIGHT ENOUGH TO PREVENT TRUNK FROMBENDING, BUT LOOSE ENOUGH TO ALLOW SOME TRUNK MOVEMENTIN WIND.123TREE CANOPY.CINCH-TIES (24" BOX/2" CAL. TREES AND SMALLER) OR12 GAUGE GALVANIZED WIRE WITH NYLON TREESTRAPS AT TREE AND STAKE (36" BOX/2.5" CAL. TREESAND LARGER). SECURE TIES OR STRAPS TO TRUNKJUST ABOVE LOWEST MAJOR BRANCHES.GREEN STEEL T-POSTS. EXTEND POSTS 12" MIN. INTOUNDISTURBED SOIL.24" X 3/4" P.V.C. MARKERS OVER WIRES.PRESSURE-TREATED WOOD DEADMAN, TWO PERTREE (MIN.). BURY OUTSIDE OF PLANTING PIT AND18" MIN. INTO UNDISTURBED SOIL.MULCH, TYPE AND DEPTH PER PLANS. DO NOTPLACE MULCH WITHIN 6" OF TRUNK.FINISH GRADE.BACKFILL. AMEND AND FERTILIZE ONLY ASRECOMMENDED IN SOIL FERTILITY ANALYSIS.ROOT BALL.UNDISTURBED NATIVE SOIL.4" HIGH EARTHEN WATERING BASIN.TRUNK FLARE.CONIFEROUSTREEPREVAILINGWINDSSTAKING EXAMPLES (PLAN VIEW)2467891011143X ROOTBALL DIA.523512NON-CONIFEROUSTREE1313FINISH GRADE.ROOT BARRIER - PLAN VIEWSCALE: NOT TO SCALEFGENERALA.QUALIFICATIONS OF LANDSCAPE CONTRACTOR1.ALL LANDSCAPE WORK SHOWN ON THESE PLANS SHALL BE PERFORMED BY A SINGLE FIRMSPECIALIZING IN LANDSCAPE PLANTING.2.A LIST OF SUCCESSFULLY COMPLETED PROJECTS OF THIS TYPE, SIZE AND NATURE MAY BEREQUESTED BY THE OWNER FOR FURTHER QUALIFICATION MEASURES.3.THE LANDSCAPE CONTRACTOR SHALL HOLD A VALID NURSERY AND FLORAL CERTIFICATE ISSUED BYTHE TEXAS DEPARTMENT OF AGRICULTURE, AS WELL AS OPERATE UNDER A COMMERCIAL PESTICIDEAPPLICATOR LICENSE ISSUED BY EITHER THE TEXAS DEPARTMENT OF AGRICULTURE OR THE TEXASSTRUCTURAL PEST CONTROL BOARD.B.SCOPE OF WORK1.WORK COVERED BY THESE SECTIONS INCLUDES THE FURNISHING AND PAYMENT OF ALL MATERIALS,LABOR, SERVICES, EQUIPMENT, LICENSES, TAXES AND ANY OTHER ITEMS THAT ARE NECESSARY FORTHE EXECUTION, INSTALLATION AND COMPLETION OF ALL WORK, SPECIFIED HEREIN AND / OR SHOWNON THE LANDSCAPE PLANS, NOTES, AND DETAILS.2.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES ANDREGULATIONS REQUIRED BY AUTHORITIES HAVING JURISDICTION OVER SUCH WORK, INCLUDING ALLINSPECTIONS AND PERMITS REQUIRED BY FEDERAL, STATE AND LOCAL AUTHORITIES IN SUPPLY,TRANSPORTATION AND INSTALLATION OF MATERIALS.3.THE LANDSCAPE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITY LINES(WATER, SEWER, ELECTRICAL, TELEPHONE, GAS, CABLE, TELEVISION, ETC.) PRIOR TO THE START OFANY WORK.PRODUCTSA.ALL MANUFACTURED PRODUCTS SHALL BE NEW.B.CONTAINER AND BALLED-AND-BURLAPPED PLANTS:1.FURNISH NURSERY-GROWN PLANTS COMPLYING WITH ANSI Z60.1-2014. PROVIDE WELL-SHAPED, FULLYBRANCHED, HEALTHY, VIGOROUS STOCK FREE OF DISEASE, INSECTS, EGGS, LARVAE, AND DEFECTSSUCH AS KNOTS, SUN SCALD, INJURIES, ABRASIONS, AND DISFIGUREMENT. ALL PLANTS WITHIN ASPECIES SHALL HAVE SIMILAR SIZE, AND SHALL BE OF A FORM TYPICAL FOR THE SPECIES. ALL TREESSHALL BE OBTAINED FROM SOURCES WITHIN 200 MILES OF THE PROJECT SITE, AND WITH SIMILARCLIMACTIC CONDITIONS.2.ROOT SYSTEMS SHALL BE HEALTHY, DENSELY BRANCHED ROOT SYSTEMS, NON-POT-BOUND, FREEFROM ENCIRCLING AND/OR GIRDLING ROOTS, AND FREE FROM ANY OTHER ROOT DEFECTS (SUCH ASJ-SHAPED ROOTS).3.TREES MAY BE PLANTED FROM CONTAINERS OR BALLED-AND-BURLAPPED (B&B), UNLESS SPECIFIEDON THE PLANTING LEGEND. BARE-ROOT TREES ARE NOT ACCEPTABLE.4.ANY PLANT DEEMED UNACCEPTABLE BY THE LANDSCAPE ARCHITECT OR OWNER SHALL BEIMMEDIATELY REMOVED FROM THE SITE AND SHALL BE REPLACED WITH AN ACCEPTBLE PLANT OF LIKETYPE AND SIZE AT THE CONTRACTOR'S OWN EXPENSE. ANY PLANTS APPEARING TO BE UNHEALTHY,EVEN IF DETERMINED TO STILL BE ALIVE, SHALL NOT BE ACCEPTED. THE LANDSCAPE ARCHITECT ANDOWNER SHALL BE THE SOLE JUDGES AS TO THE ACCEPTABILITY OF PLANT MATERIAL.5.ALL TREES SHALL BE STANDARD IN FORM, UNLESS OTHERWISE SPECIFIED. TREES WITH CENTRALLEADERS WILL NOT BE ACCEPTED IF LEADER IS DAMAGED OR REMOVED. PRUNE ALL DAMAGED TWIGSAFTER PLANTING.6.CALIPER MEASUREMENTS FOR STANDARD (SINGLE TRUNK) TREES SHALL BE AS FOLLOWS: SIX INCHESABOVE THE ROOT FLARE FOR TREES UP TO AND INCLUDING FOUR INCHES IN CALIPER, AND TWELVEINCHES ABOVE THE ROOT FLARE FOR TREES EXCEEDING FOUR INCHES IN CALIPER.7.MULTI-TRUNK TREES SHALL BE MEASURED BY THEIR OVERALL HEIGHT, MEASURED FROM THE TOP OFTHE ROOT BALL. WHERE CALIPER MEASUREMENTS ARE USED, THE CALIPER SHALL BE CALCULATEDAS ONE-HALF OF THE SUM OF THE CALIPER OF THE THREE LARGEST TRUNKS.8.ANY TREE OR SHRUB SHOWN TO HAVE EXCESS SOIL PLACED ON TOP OF THE ROOT BALL, SO THATTHE ROOT FLARE HAS BEEN COMPLETELY COVERED, SHALL BE REJECTED.C.SOD: PROVIDE WELL-ROOTED SOD OF THE VARIETY NOTED ON THE PLANS. SOD SHALL BE CUT FROMHEALTHY, MATURE TURF WITH SOIL THICKNESS OF 3/4" TO 1". EACH PALLET OF SOD SHALL BEACCOMPANIED BY A CERTIFICATE FROM SUPPLIER STATING THE COMPOSITION OF THE SOD.D.TOPSOIL: SANDY TO CLAY LOAM TOPSOIL, FREE OF STONES LARGER THAN ½ INCH, FOREIGN MATTER,PLANTS, ROOTS, AND SEEDS.E.COMPOST: WELL-COMPOSTED, STABLE, AND WEED-FREE ORGANIC MATTER, pH RANGE OF 5.5 TO 8;MOISTURE CONTENT 35 TO 55 PERCENT BY WEIGHT; 100 PERCENT PASSING THROUGH 3/4-INCH SIEVE;SOLUBLE SALT CONTENT OF 5 TO 10 DECISIEMENS/M; NOT EXCEEDING 0.5 PERCENT INERT CONTAMINANTSAND FREE OF SUBSTANCES TOXIC TO PLANTINGS. NO MANURE OR ANIMAL-BASED PRODUCTS SHALL BEUSED.F.FERTILIZER: GRANULAR FERTILIZER CONSISTING OF NITROGEN, PHOSPHORUS, POTASSIUM, AND OTHERNUTRIENTS IN PROPORTIONS, AMOUNTS, AND RELEASE RATES RECOMMENDED IN A SOIL REPORT FROM AQUALIFIED SOIL-TESTING AGENCY (SEE BELOW).G.MULCH: SIZE AND TYPE AS INDICATED ON PLANS, FREE FROM DELETERIOUS MATERIALS AND SUITABLE AS ATOP DRESSING OF TREES AND SHRUBS.H.TREE STAKING AND GUYING1.STAKES: 6' LONG GREEN METAL T-POSTS.2.GUY AND TIE WIRE: ASTM A 641, CLASS 1, GALVANIZED-STEEL WIRE, 2-STRAND, TWISTED, 0.106 INCHDIAMETER.3.STRAP CHAFING GUARD: REINFORCED NYLON OR CANVAS AT LEAST 1-1/2 INCH WIDE, WITHGROMMETS TO PROTECT TREE TRUNKS FROM DAMAGE.I.STEEL EDGING: PROFESSIONAL STEEL EDGING, 14 GAUGE THICK X 4 INCHES WIDE, FACTORY PAINTED DARKGREEN. ACCEPTABLE MANUFACTURERS INCLUDE COL-MET OR APPROVED EQUAL.J.PRE-EMERGENT HERBICIDES: ANY GRANULAR, NON-STAINING PRE-EMERGENT HERBICIDE THAT IS LABELEDFOR THE SPECIFIC ORNAMENTALS OR TURF ON WHICH IT WILL BE UTILIZED. PRE-EMERGENT HERBICIDESSHALL BE APPLIED PER THE MANUFACTURER'S LABELED RATES.METHODSA.SOIL PREPARATION1.BEFORE STARTING WORK, THE LANDSCAPE CONTRACTOR SHALL VERIFY THAT THE GRADE OF ALLLANDSCAPE AREAS ARE WITHIN +/-0.1' OF FINISH GRADE. THE CONTRACTOR SHALL NOTIFY THEOWNER IMMEDIATELY SHOULD ANY DISCREPANCIES EXIST.2.SOIL TESTING:a.AFTER FINISH GRADES HAVE BEEN ESTABLISHED, CONTRACTOR SHALL HAVE SOIL SAMPLESFROM THE PROJECT'S LANDSCAPE AREAS TESTED BY AN ESTABLISHED SOIL TESTINGLABORATORY. EACH SAMPLE SUBMITTED TO THE LAB SHALL CONTAIN NO LESS THAN ONEQUART OF SOIL, TAKEN FROM BETWEEN THE SOIL SURFACE AND 6" DEPTH. IF NO SAMPLELOCATIONS ARE INDICATED ON THE PLANS, THE CONTRACTOR SHALL TAKE A MINIMUM OF THREESAMPLES FROM VARIOUS REPRESENTATIVE LOCATIONS FOR TESTING.b.THE CONTRACTOR SHALL HAVE THE SOIL TESTING LABORATORY PROVIDE RESULTS FOR THEFOLLOWING: SOIL TEXTURAL CLASS, GENERAL SOIL FERTILITY, pH, ORGANIC MATTER CONTENT,SALT (CEC), LIME, SODIUM ADSORPTION RATIO (SAR) AND BORON CONTENT.c.THE CONTRACTOR SHALL ALSO SUBMIT THE PROJECT'S PLANT LIST TO THE LABORATORY ALONGWITH THE SOIL SAMPLES.d.THE SOIL REPORT PRODUCED BY THE LABORATORY SHALL CONTAIN RECOMMENDATIONS FORTHE FOLLOWING (AS APPROPRIATE): SEPARATE SOIL PREPARATION AND BACKFILL MIXRECOMMENDATIONS FOR GENERAL ORNAMENTAL PLANTS, XERIC PLANTS, TURF, AND NATIVESEED, AS WELL AS PRE-PLANT FERTILIZER APPLICATIONS AND RECOMMENDATIONS FOR ANYOTHER SOIL RELATED ISSUES. THE REPORT SHALL ALSO PROVIDE A FERTILIZER PROGRAM FORTHE ESTABLISHMENT PERIOD AND FOR LONG-TERM MAINTENANCE.3.THE CONTRACTOR SHALL INSTALL SOIL AMENDMENTS AND FERTILIZERS PER THE SOILS REPORTRECOMMENDATIONS. ANY CHANGE IN COST DUE TO THE SOIL REPORT RECOMMENDATIONS, EITHERINCREASE OR DECREASE, SHALL BE SUBMITTED TO THE OWNER WITH THE REPORT.4.FOR BIDDING PURPOSES ONLY, THE SOIL PREPARATION SHALL CONSIST OF THE FOLLOWING:a.TURF: INCORPORATE THE FOLLOWING AMENDMENTS INTO THE TOP 8" OF SOIL BY MEANS OFROTOTILLING AFTER CROSS-RIPPING:i.NITROGEN STABILIZED ORGANIC AMENDMENT - 4 CU. YDS. PER 1,000 S.F.ii.PREPLANT TURF FERTILIZER (10-20-10 OR SIMILAR, SLOW RELEASE, ORGANIC) - 15 LBS PER 1,000S.F.iii."CLAY BUSTER" OR EQUAL - USE MANUFACTURER'S RECOMMENDED RATEb.TREES, SHRUBS, AND PERENNIALS: INCORPORATE THE FOLLOWING AMENDMENTS INTO THE TOP8" OF SOIL BY MEANS OF ROTOTILLING AFTER CROSS-RIPPING:i.NITROGEN STABILIZED ORGANIC AMENDMENT - 4 CU. YDS. PER 1,000 S.F.ii.12-12-12 FERTILIZER (OR SIMILAR, ORGANIC, SLOW RELEASE) - 10 LBS. PER CU. YD.iii."CLAY BUSTER" OR EQUAL - USE MANUFACTURER'S RECOMMENDED RATEiv.IRON SULPHATE - 2 LBS. PER CU. YD.5.IN THE CONTEXT OF THESE PLANS, NOTES, AND SPECIFICATIONS, "FINISH GRADE" REFERS TO THEFINAL ELEVATION OF THE SOIL SURFACE (NOT TOP OF MULCH) AS INDICATED ON THE GRADING PLANS.a.BEFORE STARTING WORK, THE LANDSCAPE CONTRACTOR SHALL VERIFY THAT THE ROUGHGRADES OF ALL LANDSCAPE AREAS ARE WITHIN +/-0.1' OF FINISH GRADE. SEE SPECIFICATIONSFOR MORE DETAILED INSTRUCTION ON TURF AREA AND PLANTING BED PREPARATION.b.CONSTRUCT AND MAINTAIN FINISH GRADES AS SHOWN ON GRADING PLANS, AND CONSTRUCTAND MAINTAIN SLOPES AS RECOMMENDED BY THE GEOTECHNICAL REPORT. ALL LANDSCAPEAREAS SHALL HAVE POSITIVE DRAINAGE AWAY FROM STRUCTURES AT THE MINIMUM SLOPESPECIFIED IN THE REPORT AND ON THE GRADING PLANS, AND AREAS OF POTENTIAL PONDINGSHALL BE REGRADED TO BLEND IN WITH THE SURROUNDING GRADES AND ELIMINATE PONDINGPOTENTIAL.c.THE LANDSCAPE CONTRACTOR SHALL DETERMINE WHETHER OR NOT THE EXPORT OF ANY SOILWILL BE NEEDED, TAKING INTO ACCOUNT THE ROUGH GRADE PROVIDED, THE AMOUNT OF SOILAMENDMENTS TO BE ADDED (BASED ON A SOIL TEST, PER SPECIFICATIONS), AND THE FINISHGRADES TO BE ESTABLISHED.d.ENSURE THAT THE FINISH GRADE IN SHRUB AREAS IMMEDIATELY ADJACENT TO WALKS ANDOTHER WALKING SURFACES, AFTER INSTALLING SOIL AMENDMENTS, IS 3" BELOW THE ADJACENTFINISH SURFACE, IN ORDER TO ALLOW FOR PROPER MULCH DEPTH. TAPER THE SOIL SURFACETO MEET FINISH GRADE, AS SPECIFIED ON THE GRADING PLANS, AT APPROXIMATELY 18" AWAYFROM THE WALKS.e.ENSURE THAT THE FINISH GRADE IN TURF AREAS IMMEDIATELY ADJACENT TO WALKS ANDOTHER WALKING SURFACES, AFTER INSTALLING SOIL AMENDMENTS, IS 1" BELOW THE FINISHSURFACE OF THE WALKS. TAPER THE SOIL SURFACE TO MEET FINISH GRADE, AS SPECIFIED ONTHE GRADING PLANS, AT APPROXIMATELY 18" AWAY FROM THE WALKS.f.SHOULD ANY CONFLICTS AND/OR DISCREPANCIES ARISE BETWEEN THE GRADING PLANS,GEOTECHNICAL REPORT, THESE NOTES AND PLANS, AND ACTUAL CONDITIONS, THECONTRACTOR SHALL IMMEDIATELY BRING SUCH ITEMS TO THE ATTENTION OF THE LANDSCAPEARCHITECT, GENERAL CONTRACTOR, AND OWNER.6.ONCE SOIL PREPARATION IS COMPLETE, THE LANDSCAPE CONTRACTOR SHALL ENSURE THAT THEREARE NO DEBRIS, TRASH, OR STONES LARGER THAN 1" REMAINING IN THE TOP 6" OF SOIL.B.SUBMITTALS1.THE CONTRACTOR SHALL PROVIDE SUBMITTALS AND SAMPLES, IF REQUIRED, TO THE LANDSCAPEARCHITECT, AND RECEIVE APPROVAL IN WRITING FOR SUCH SUBMITTALS BEFORE WORK COMMENCES.2.SUBMITTALS SHALL INCLUDE PHOTOS OF PLANTS WITH A RULER OR MEASURING STICK FOR SCALE,PHOTOS OR SAMPLES OF ANY REQUIRED MULCHES, AND SOIL TEST RESULTS AND PREPARATIONRECOMMENDATIONS FROM THE TESTING LAB (INCLUDING COMPOST AND FERTILIZER RATES ANDTYPES, AND OTHER AMENDMENTS FOR TREE/SHRUB, TURF, AND SEED AREAS AS MAY BEAPPROPRIATE).3.SUBMITTALS SHALL ALSO INCLUDE MANUFACTURER CUT SHEETS FOR PLANTING ACCESSORIES SUCHAS TREE STAKES AND TIES, EDGING, AND LANDSCAPE FABRICS (IF ANY).4.WHERE MULTIPLE ITEMS ARE SHOWN ON A PAGE, THE CONTRACTOR SHALL CLEARLY INDICATE THEITEM BEING CONSIDERED.C.GENERAL PLANTING1.REMOVE ALL NURSERY TAGS AND STAKES FROM PLANTS.2.EXCEPT IN AREAS TO BE PLANTED WITH ORNAMENTAL GRASSES, APPLY PRE-EMERGENT HERBICIDESAT THE MANUFACTURER'S RECOMMENDED RATE.3.TRENCHING NEAR EXISTING TREES:a.CONTRACTOR SHALL NOT DISTURB ROOTS 1-1/2" AND LARGER IN DIAMETER WITHIN THE CRITICALROOT ZONE (CRZ) OF EXISTING TREES, AND SHALL EXERCISE ALL POSSIBLE CARE ANDPRECAUTIONS TO AVOID INJURY TO TREE ROOTS, TRUNKS, AND BRANCHES. THE CRZ ISDEFINED AS A CIRCULAR AREA EXTENDING OUTWARD FROM THE TREE TRUNK, WITH A RADIUSEQUAL TO 1' FOR EVERY 1" OF TRUNK DIAMETER-AT-BREAST-HEIGHT (4.5' ABOVE THE AVERAGEGRADE AT THE TRUNK).b.ALL EXCAVATION WITHIN THE CRZ SHALL BE PERFORMED USING HAND TOOLS. NO MACHINEEXCAVATION OR TRENCHING OF ANY KIND SHALL BE ALLOWED WITHIN THE CRZ.c.ALTER ALIGNMENT OF PIPE TO AVOID TREE ROOTS 1-1/2" AND LARGER IN DIAMETER. WHERETREE ROOTS 1-1/2" AND LARGER IN DIAMETER ARE ENCOUNTERED IN THE FIELD, TUNNEL UNDERSUCH ROOTS. WRAP EXPOSED ROOTS WITH SEVERAL LAYERS OF BURLAP AND KEEP MOIST.CLOSE ALL TRENCHES WITHIN THE CANOPY DRIP LINES WITHIN 24 HOURS.d.ALL SEVERED ROOTS SHALL BE HAND PRUNED WITH SHARP TOOLS AND ALLOWED TO AIR-DRY.DO NOT USE ANY SORT OF SEALERS OR WOUND PAINTS.D.TREE PLANTING1.TREE PLANTING HOLES SHALL BE EXCAVATED TO MINIMUM WIDTH OF TWO TIMES THE WIDTH OF THEROOTBALL, AND TO A DEPTH EQUAL TO THE DEPTH OF THE ROOTBALL LESS TWO TO FOUR INCHES.2.SCARIFY THE SIDES AND BOTTOM OF THE PLANTING HOLE PRIOR TO THE PLACEMENT OF THE TREE.REMOVE ANY GLAZING THAT MAY HAVE BEEN CAUSED DURING THE EXCAVATION OF THE HOLE.3.FOR CONTAINER AND BOX TREES, TO REMOVE ANY POTENTIALLY GIRDLING ROOTS AND OTHER ROOTDEFECTS, THE CONTRACTOR SHALL SHAVE A 1" LAYER OFF OF THE SIDES AND BOTTOM OF THEROOTBALL OF ALL TREES JUST BEFORE PLACING INTO THE PLANTING PIT. DO NOT "TEASE" ROOTSOUT FROM THE ROOTBALL.4.INSTALL THE TREE ON UNDISTURBED SUBGRADE SO THAT THE TOP OF THE ROOTBALL IS TWO TOFOUR INCHES ABOVE THE SURROUNDING GRADE.5.BACKFILL THE TREE HOLE UTILIZING THE EXISTING TOPSOIL FROM ON-SITE. ROCKS LARGER THAN 1"DIA. AND ALL OTHER DEBRIS SHALL BE REMOVED FROM THE SOIL PRIOR TO THE BACKFILL. SHOULDADDITIONAL SOIL BE REQUIRED TO ACCOMPLISH THIS TASK, USE STORED TOPSOIL FROM ON-SITE ORIMPORT ADDITIONAL TOPSOIL FROM OFF-SITE AT NO ADDITIONAL COST TO THE OWNER. IMPORTEDTOPSOIL SHALL BE OF SIMILAR TEXTURAL CLASS AND COMPOSITION IN THE ON-SITE SOIL.6.TREES SHALL NOT BE STAKED UNLESS LOCAL CONDITIONS (SUCH AS HEAVY WINDS OR SLOPES)REQUIRE STAKES TO KEEP TREES UPRIGHT. SHOULD STAKING BE REQUIRED, THE TOTAL NUMBER OFTREE STAKES (BEYOND THE MINIMUMS LISTED BELOW) WILL BE LEFT TO THE LANDSCAPECONTRACTOR'S DISCRETION. SHOULD ANY TREES FALL OR LEAN, THE LANDSCAPE CONTRACTORSHALL STRAIGHTEN THE TREE, OR REPLACE IT SHOULD IT BECOME DAMAGED. TREE STAKING SHALLADHERE TO THE FOLLOWING GUIDELINES:a.1"-2" TREESTWO STAKES PER TREEb.2-1/2"-4" TREESTHREE STAKES PER TREEc.TREES OVER 4" CALIPERGUY AS NEEDEDd.MULTI-TRUNK TREESTHREE STAKES PER TREE MINIMUM, QUANTITY AND POSITIONS ASNEEDED TO STABILIZE THE TREEe.MULTI-TRUNK TREESTHREE STAKES PER TREE MINIMUM, QUANTITY AND POSITIONS ASNEEDED TO STABILIZE THE TREE7.UPON COMPLETION OF PLANTING, CONSTRUCT AN EARTH WATERING BASIN AROUND THE TREE.COVER THE INTERIOR OF THE TREE RING WITH THE WEED BARRIER CLOTH AND TOPDRESS WITHMULCH (TYPE AND DEPTH PER PLANS).E.SHRUB, PERENNIAL, AND GROUNDCOVER PLANTING1.DIG THE PLANTING HOLES TWICE AS WIDE AND 2" LESS DEEP THAN EACH PLANT'S ROOTBALL. INSTALLTHE PLANT IN THE HOLE. BACKFILL AROUND THE PLANT WITH SOIL AMENDED PER SOIL TESTRECOMMENDATIONS.2.INSTALL THE WEED BARRIER CLOTH, OVERLAPPING IT AT THE ENDS. UTILIZE STEEL STAPLES TO KEEPTHE WEED BARRIER CLOTH IN PLACE.3.WHEN PLANTING IS COMPLETE, INSTALL MULCH (TYPE AND DEPTH PER PLANS) OVER ALL PLANTINGBEDS, COVERING THE ENTIRE PLANTING AREA.F.SODDING1.SOD VARIETY TO BE AS SPECIFIED ON THE LANDSCAPE PLAN.2.LAY SOD WITHIN 24 HOURS FROM THE TIME OF STRIPPING. DO NOT LAY IF THE GROUND IS FROZEN.3.LAY THE SOD TO FORM A SOLID MASS WITH TIGHTLY FITTED JOINTS. BUTT ENDS AND SIDES OF SODSTRIPS - DO NOT OVERLAP. STAGGER STRIPS TO OFFSET JOINTS IN ADJACENT COURSES.4.ROLL THE SOD TO ENSURE GOOD CONTACT OF THE SOD'S ROOT SYSTEM WITH THE SOILUNDERNEATH.5.WATER THE SOD THOROUGHLY WITH A FINE SPRAY IMMEDIATELY AFTER PLANTING TO OBTAIN ATLEAST SIX INCHES OF PENETRATION INTO THE SOIL BELOW THE SOD.G.MULCH1.INSTALL MULCH TOPDRESSING, TYPE AND DEPTH PER MULCH NOTE, IN ALL PLANTING AREAS ANDTREE RINGS.2.DO NOT INSTALL MULCH WITHIN 6" OF TREE ROOT FLARE AND WITHIN 24" OF HABITABLE STRUCTURES,EXCEPT AS MAY BE NOTED ON THESE PLANS. MULCH COVER WITHIN 6" OF CONCRETE WALKS ANDCURBS SHALL NOT PROTRUDE ABOVE THE FINISH SURFACE OF THE WALKS AND CURBS. MULCHCOVER WITHIN 12" OF WALLS SHALL BE AT LEAST 3" LOWER THAN THE TOP OF WALL.H.CLEAN UP1.DURING LANDSCAPE PREPARATION AND PLANTING, KEEP ALL PAVEMENT CLEAN AND ALL WORK AREASIN A NEAT, ORDERLY CONDITION.2.DISPOSED LEGALLY OF ALL EXCAVATED MATERIALS OFF THE PROJECT SITE.I.INSPECTION AND ACCEPTANCE1.UPON COMPLETION OF THE WORK, THE LANDSCAPE CONTRACTOR SHALL PROVIDE THE SITE CLEAN,FREE OF DEBRIS AND TRASH, AND SUITABLE FOR USE AS INTENDED. THE LANDSCAPE CONTRACTORSHALL THEN REQUEST AN INSPECTION BY THE OWNER TO DETERMINE FINAL ACCEPTABILITY.2.WHEN THE INSPECTED PLANTING WORK DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS, THELANDSCAPE CONTRACTOR SHALL REPLACE AND/OR REPAIR THE REJECTED WORK TO THE OWNER'SSATISFACTION WITHIN 24 HOURS.3.THE LANDSCAPE MAINTENANCE PERIOD WILL NOT COMMENCE UNTIL THE LANDSCAPE WORK HASBEEN RE-INSPECTED BY THE OWNER AND FOUND TO BE ACCEPTABLE. AT THAT TIME, A WRITTENNOTICE OF FINAL ACCEPTANCE WILL BE ISSUED BY THE OWNER, AND THE MAINTENANCE ANDGUARANTEE PERIODS WILL COMMENCE.J.LANDSCAPE MAINTENANCE1.THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL WORK SHOWNON THESE PLANS FOR 90 DAYS BEYOND FINAL ACCEPTANCE OF ALL LANDSCAPE WORK BY THEOWNER. LANDSCAPE MAINTENANCE SHALL INCLUDE WEEKLY SITE VISITS FOR THE FOLLOWINGACTIONS (AS APPROPRIATE): PROPER PRUNING, RESTAKING OF TREES, RESETTING OF PLANTS THATHAVE SETTLED, MOWING AND AERATION OF LAWNS, WEEDING, TREATING FOR INSECTS ANDDISEASES,REPLACEMENT OF MULCH, REMOVAL OF LITTER, REPAIRS TO THE IRRIGATION SYSTEM DUETO FAULTY PARTS AND/OR WORKMANSHIP, AND THE APPROPRIATE WATERING OF ALL PLANTINGS.THE LANDSCAPE CONTRACTOR SHALL MAINTAIN THE IRRIGATION SYSTEM IN PROPER WORKINGORDER, WITH SCHEDULING ADJUSTMENTS BY SEASON TO MAXIMIZE WATER CONSERVATION.2. SHOULD SEEDED AND/OR SODDED AREAS NOT BE COVERED BY AN AUTOMATIC IRRIGATION SYSTEM,THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR WATERING THESE AREAS AND OBTAININGA FULL, HEALTHY STAND OF PLANTS AT NO ADDITIONAL COST TO THE OWNER.3.TO ACHIEVE FINAL ACCEPTANCE AT THE END OF THE MAINTENANCE PERIOD, ALL OF THE FOLLOWINGCONDITIONS MUST OCCUR:a.THE LANDSCAPE SHALL SHOW ACTIVE, HEALTHY GROWTH (WITH EXCEPTIONS MADE FORSEASONAL DORMANCY). ALL PLANTS NOT MEETING THIS CONDITION SHALL BE REJECTED ANDREPLACED BY HEALTHY PLANT MATERIAL PRIOR TO FINAL ACCEPTANCE.b.ALL HARDSCAPE SHALL BE CLEANED PRIOR TO FINAL ACCEPTANCE.c.SODDED AREAS MUST BE ACTIVELY GROWING AND MUST REACH A MINIMUM HEIGHT OF 1 1/2INCHES BEFORE FIRST MOWING. BARE AREAS LARGER THAN TWELVE SQUARE INCHES MUST BERESODDED (AS APPROPRIATE) PRIOR TO FINAL ACCEPTANCE. ALL SODDED TURF SHALL BENEATLY MOWED.K.WARRANTY PERIOD, PLANT GUARANTEE AND REPLACEMENTS1.THE LANDSCAPE CONTRACTOR SHALL GUARANTEE ALL TREES, SHRUBS, PERENNIALS, SOD, ANDIRRIGATION SYSTEMS FOR A PERIOD OF ONE YEAR FROM THE DATE OF THE OWNER'S FINALACCEPTANCE (90 DAYS FOR ANNUAL PLANTS). THE CONTRACTOR SHALL REPLACE, AT HIS OWNEXPENSE AND TO THE SATISFACTION OF THE OWNER, ANY PLANTS WHICH DIE IN THAT TIME, ORREPAIR ANY PORTIONS OF THE IRRIGATION SYSTEM WHICH OPERATE IMPROPERLY.2.AFTER THE INITIAL MAINTENANCE PERIOD AND DURING THE GUARANTEE PERIOD, THE LANDSCAPECONTRACTOR SHALL ONLY BE RESPONSIBLE FOR REPLACEMENT OF PLANTS WHEN PLANT DEATHCANNOT BE ATTRIBUTED DIRECTLY TO OVERWATERING OR OTHER DAMAGE BY HUMAN ACTIONS.L.PROVIDE A MINIMUM OF (2) COPIES OF RECORD DRAWINGS TO THE OWNER UPON COMPLETION OF WORK. ARECORD DRAWING IS A RECORD OF ALL CHANGES THAT OCCURRED IN THE FIELD AND THAT AREDOCUMENTED THROUGH CHANGE ORDERS, ADDENDA, OR CONTRACTOR/CONSULTANT DRAWING MARKUPS.TYPICAL CURB AND GUTTERTYPICAL PLANTING AREALINEAR ROOT BARRIER MATERIAL. SEEPLANTING NOTES FOR TYPE ANDMANUFACTURER. INSTALL PERMANUFACTURER'S SPECIFICATIONS.TREE CANOPYTREE TRUNKTYPICAL WALKWAY OR PAVING1234561423565'5'5'5'OPEN LANDSCAPETO 10'PARKWAYOR ISLANDNOTES:1)INSTALL ROOT BARRIERS NEAR ALLNEWLY-PLANTED TREES THAT ARE LOCATEDWITHIN FIVE (5) FEET OF PAVING OR CURBS.2)BARRIERS SHALL BE LOCATED IMMEDIATELYADJACENT TO HARDSCAPE. UNDER NOCIRCUMSTANCES SHALL THE CONTRACTORUSE ROOT BARRIERS OF A TYPE THATCOMPLETELY ENCIRCLE THE ROOTBALL.P:\Shared\Projects\2024\AC HOTEL BY MARRIOTT - COPPELL TX - 635 & BELTLINE\AC Marriott - Coppell TX_LP 2024-07-11.dwg Jul 11,2024 - 12:12pm ComputerTexas Board of Professional Engineers and Land Surveyors Registration Nos. F-23290 & 10046100
2805 Dallas Parkway, Suite 600 Plano, TX 75093 972.488.3880
AC HOTEL BY MARRIOTT
1543 S BELT LINE RD - COPPELL, TX, 75093
No.REVISIONSHEET NO.JOB NO.:
DESIGNED BY.:
CHECKED BY:DATE:
DRAWN BY:
APP.Date
(800) 680-663015455 Dallas Pkwy, Ste 600Addison, TX 75001www.EvergreenDesignGroup.comEVERGREENDESIGN GROUPLP-2LANDSCAPE DETAILS AND SPECIFICATIONS.HIAENSSTE
HCCTTES
A
P
ETSTAIREG
03OF47ETX LRLDRE
CAANDSWEPAESETSSITE PLANAC HOTELPD-221R3R5-HCLOT 1R-8RBLK C DUKE LESLEY (AC BY MARRIOTT)Administratively Approved on 07/15/2024
DD D
W W W
UP
B.0
D.0
E.0
F.0
1.02.03.05.0 4.09.0 8.0 7.0 6.013.014.0 10.011.012.015.018.0 17.0 16.019.0
131
MEETING SPACE
108
LAUNDRY
111
BREAK ROOM
113
WORK SPACE
102
MECHANICAL
G.0
C.0
A.0
A5.01
1
117
IDF
114
OFFICE
115
OFFICE
116
OFFICE
112
KITCHEN
121
VESTIBULE
129
WOMENS RR
130
MENS RR
124
BAR
106
ENG. OFFICE
104
ELECTRICAL
120
RECEPTION
107
02 DQ
109
02 DQ
105
02 DQ
103
02 DQ
110
ELEV. LOBBY
101
04 DQ ADA
100
STAIR 1118
BISTRO
119
LUGGAGE
123
DINING
122
LOBBY
125
LIBRARY
135
STAIR 2
126
MEDIA SALON
127
MEDIA SALON
128
MEETING CORRIDOR1'-2"12'-9 1/2"1'-2"12'-9 1/2"1'-6"5'-1"30'-11 1/2"8'-6"64'-6 1/2"6'-4"59'-1 1/2"52'-6 1/2"10'-8"
13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"13'-0"
A5.02 2
25'-2"25'-2"108B
LINEN STORAGE
A5.021
A5.01
2
50'-11 1/2"1'-8"18'-0 1/2"2'-7 3/4"10'-7 3/4"61'-7 1/4"45'-3 1/4"4'-6 3/4"6'-0"5'-0"6'-0"5'-0"6'-0"5'-0"10'-8"4'-2 3/4"6'-3 1/4"13'-0"13'-0"5'-8"1'-8"11'-4"1'-8"11'-4"1'-8"1'-5 3/4"
232'-8"33'-6 3/4"11'-6 3/4"23'-3 1/4"16'-10 3/4"10'-7 3/4"6'-11 1/4"34'-4"2'-3"9'-6"2'-11"11'-4"2'-11"9'-6"2'-10"10'-2"2'-10"10'-8"8 1/4"
PD-221R3R5-HC, LOT 1R-8R, BLK C DUKE LESLEY (AC BY MARRIOTT)
CITY OF COPPELL
DALLAS COUNTY, TEXAS 75019
OWNER
WHITESTONE HOSPITALITY, LLC
972.600.8162
PREPARED BY:
TYPE-SIX DESIGN AND DEVELOPMENT
PROJECT CONTACT: CONNOR WALKER, AIA
920 SOUTH MAIN STREET, SUITE 150
GRAPEVINE, TEXAS 76051
AC HOTEL -BY MARRIOTT
SUBMITTAL DATE: 15 JULY 2024
SITE
SITE LOCATION
ROOM MATRIX
GUESTROOMS
01 KING
1ST FLOOR 2ND FLOOR 3RD FLOOR 4TH FLOOR 5TH FLOOR
0 1916
02 DOUBLE QUEEN
0 1
1 1
00
1 1
4 1211 12
03 KING ACCESSIBLE
04 DQ ACCESSIBLE
19
1
1
11
19
TOTALS
73
4
3
50
TOTAL 325293232 130
SHEET NUMBER
ISSUE DATE
ISSUED FOR
ARCHITECT
D. HAYES HINKLE
TYPE-SIX
DEVELOPMENT SERVICES, LLC
TYPE-SIX
SHEET NAME
REVIEW
THIS DOCUMENT IS
INCOMPLETE AND MAY
NOT BE USED FOR
REGULATORY APPROVAL,
PERMIT, OR
CONSTRUCTION.
D. HAYES HINKLE - 26067
910 SOUTH MAIN STREET #150
GRAPEVINE, TEXAS 76054
972.677.9075
7 /1 5 /2 0 2 4 6 :3 5 :4 1 A M
A1.01
01 DIMENSION PLANWHITESTONE HOSPITALITYAC HOTEL BY MARRIOTT7.12.2024 PROJECT # 24021POINT WEST DEVELOPMENT - PD ZONINGLOT 1R-8R, BLOCK C1/8" = 1'-0"1 01 LEVEL - DIMENSION PLAN
# Revision Date
1
4' 8'16'0
2"0
1/8" = 1'-0"
Administratively Approved on 07/15/2024
DN UP
DN
UP
PD-221R3R5-HC, LOT 1R-8R, BLK C DUKE LESLEY (AC BY MARRIOTT)
CITY OF COPPELL
DALLAS COUNTY, TEXAS 75019
OWNER
WHITESTONE HOSPITALITY, LLC
972.600.8162
PREPARED BY:
TYPE-SIX DESIGN AND DEVELOPMENT
PROJECT CONTACT: CONNOR WALKER, AIA
920 SOUTH MAIN STREET, SUITE 150
GRAPEVINE, TEXAS 76051
AC HOTEL -BY MARRIOTT
SUBMITTAL DATE: 15 JULY 2024
SITE
SITE LOCATION
B.0
D.0
E.0
F.0
1.02.03.05.0 4.09.0 8.0 7.0 6.013.014.0 10.011.012.015.018.0 17.0 16.019.0
G.0
A.0
302
02 DQ
300
STAIR 1
301
01 KING
303
01 KING
304
02 DQ
305
02 DQ
306
02 DQ
307
02 DQ
308
02 DQ
309
02 DQ
310
01 KING
311
02 DQ
312
BOH
313
02 DQ
314
ELECTRICAL/IT
315
02 DQ
316
01 KING
317
01 KING
318
01 KING
319
01 KING
320
01 KING
321
01 KING
322
01 KING
323
01 KING
324
01 KING
325
01 KING
326
01 KING
327
01 KING
328
01 KING
329
01 KING
330
01 KING
331
01 KING
332
02 DQ
333
03 KING ADA
334
02 DQ
335
STAIR 2
26'-5 1/2"103'-6 1/2"26'-0"13'-5 1/2"52'-6 1/2"10'-8"3'-10 3/4"
336
ELEVATOR LOBBY
27'-8"6'-8"31'-5 3/4"65'-9 3/4"236'-6 3/4"29'-1"7'-11"6'-7"23'-3 1/4"130'-6"78'-5 1/4"28'-1 1/2"
B.0
D.0
E.0
F.0
1.02.03.05.0 4.09.0 8.0 7.0 6.013.014.0 10.011.012.015.018.0 17.0 16.019.0
G.0
C.0
A.0
A5.01
1
202
04 DQ ADA
200
STAIR 1
201
01 KING
203
01KING
204
02 DQ
206
02 DQ
208
02 DQ
210
01 KING212
BOH
216
01 KING
218
01 KING
223
01 KING
225
01 KING
222
FITNESS
227
01 KING
228
01 KING
229
01 KING
230
01 KING
231
01 KING
232
02 DQ
233
03 KING ADA
234
02 DQ
235
STAIR 2
205
02 DQ
207
02 DQ
209
02 DQ
211
02 DQ
213
02 DQ
215
02 DQ
217
01 KING
219
01 KING
221
01 KING
A5.02 2
236
ELEVATOR LOBBY
220
01 KING
64'-10"A5.021
226
ELECTRICAL/IT
A5.01
2
27'-8"6'-8"31'-6"26'-5 1/2"103'-6 1/2"26'-0"13'-5 1/2"52'-6 1/2"10'-8"3'-10 3/4"
236'-6 3/4"
130'-6"78'-5 1/4"28'-1 1/2"29'-1"7'-11"6'-8 1/2"23'-1 3/4"3'-10 3/4"1'-6 1/2"2'-1 1/4"
FITNESS STORAGE CLOSET
AC UNIT CLOSET
SHEET NUMBER
ISSUE DATE
ISSUED FOR
ARCHITECT
D. HAYES HINKLE
TYPE-SIX
DEVELOPMENT SERVICES, LLC
TYPE-SIX
SHEET NAME
REVIEW
THIS DOCUMENT IS
INCOMPLETE AND MAY
NOT BE USED FOR
REGULATORY APPROVAL,
PERMIT, OR
CONSTRUCTION.
D. HAYES HINKLE - 26067
910 SOUTH MAIN STREET #150
GRAPEVINE, TEXAS 76054
972.677.9075
7 /1 5 /2 0 2 4 6 :3 5 :4 7 A M
A1.02
UPPER LEVEL DIMENSION
PLANSWHITESTONE HOSPITALITYAC HOTEL BY MARRIOTT7.12.2024 PROJECT # 24021POINT WEST DEVELOPMENT - PD ZONINGLOT 1R-8R, BLOCK C# Revision Date
14' 8'16'0
2"0
1/8" = 1'-0"
1/8" = 1'-0"2 3RD- 5TH - DIMENSION PLAN
1/8" = 1'-0"1 02 LEVEL - DIMENSION PLAN
4' 8'16'0
2"0
1/8" = 1'-0"
4' 8'16'0
2"0
1/8" = 1'-0"
Administratively Approved on 07/15/2024
EI-1 EIFS -"SW7003 -TOQUE WHITE
MATERIAL CALLOUTS
KING KLINKER -WHITE NIGHT -CHARCOAL GREY -TYPE N MORTARBR-1
SF STOREFRONT -KAWNEER -"DARK BRONZE #40"
EI-3
GL EXTERIOR WINDOWS: STOREFRONT WINDOW SYSTEM
LOUVER FINISH -DARK BRONZE TO MATCH STOREFRONTLF-1
AF-1 ALUMINUM PARAPET FLASHING TO MATCH STOREFRONT
EI-2 EFIS -"SW7054 -MODERN GREY
ADDITIONAL NOTES:
EN-V VS SERIES METAL PANEL -MUSKET GREY
ELEVATION PRECENTAGES
WS-1 CORONADO -BARN WOOD STONE -RUSTIC FARMHOUSE
• ALL SIGNAGE SUBJECT TO BUILDING INSPECTION
DEPARTMENT APPROVAL.
• MECHANICAL UNITS SHALL BE SCREENED IN ACCORDANCE
WITH LOCAL CITY AND ZONING ORDINANCES.
• UTILITY BOXES AND CONDUIT SHALL BE PAINTED TO MATCH
BUILDING COLOR
• ROMAN SIZE, FACE BRICK, WITH 3/8" CONCAVE GROUT
JOINT-MORTAR TO BE MATCHED TO GROUT
• CONTRACTOR TO ENSURE METAL PANELS ARE INSTALLED IN
ACCORDANCE WITH MANUFACTURERS RECOMMENDATION.
• SIGN DESIGNED AND FABRICRATED BY APPROVED VENDOR
TO MEET BRAND STANDARDS, FOR LOCATION ONLY
• ALL UTILITY BOXES AND METERS SHALL BE PAINTED TO MATCH
SURROUNDING BUILDING FACADE.
• FINAL SIGN DESIGN TO BE DRAFTER BY THIRD PARTY
CONTRACTOR TO ENSURE FINAL SIGN PACKAGE IS
SUBMITTED APPROVED BY THE BRAND
MP-1
EFIS -"SW7047 PORPOISE"
NORTH ELEVATION
OVERALL -5,454 TOTAL SQ. FT.
268 SQ. FT. -GLAZING
5,186 SQ. FT. -MASONRY MATERIALS
• EIFS
• STONE
• MASONRY COMPOSITE
PANELS
SOUTH ELEVATION
OVERALL -5,449 TOTAL SQ. FT.
536 SQ. FT. -GLAZING
4,330 SQ. FT. -MASONRY MATERIALS
• EIFS
• STONE
• MASONRY COMPOSITE
PANELS
583 SQ. FT. -METAL PANEL( 9%)
SIGNAGE -100SF
EAST ELEVATION
OVERALL -16,636 TOTAL SQ. FT.
3,622 SQ. FT. -GLAZING
12,391 SQ. FT. -MASONRY MATERIALS
• EIFS
• STONE
• MASONRY COMPOSITE
PANELS
623 SQ. FT. -METAL PANEL(3%)
SIGNAGE -130SF
WEST ELEVATION
OVERALL -16,561 TOTAL SQ. FT.
3,063 SQ. FT. -GLAZING
13,041 SQ. FT. -MASONRY MATERIALS
• EIFS
• STONE
• MASONRY COMPOSITE
PANELS
457 SQ. FT. -METAL PANEL(2.7%)
SIGNAGE -148SF
HIGHWAY COMMERCIAL EXTERIOR CONSTRUCTION REGULATIONS
CORNICE/CAP
3 COLORS MAX.
100% MAX BASE COLOR
5% MAX SECONDARY COLOR & 1% MAX ACCENT COLOR
50% MAX GLAZING PER FACADE
ZONING
YES
YES -3 EIFS COLORS
YES
NO (PREV. APPROVED)
YES
NOTE: ALL ATTACHED BUILDING SIGNAGE WILL COMPLY WITH
THE SIGN SECTION OF THE ZONING ORDINANCE AND WILL BE
PERMITTED SEPARATELY.
01 LEVEL
0' -0"
02 LEVEL
18' -0"
03 LEVEL
29' -2"
04 LEVEL
40' -4"
05 LEVEL
51' -6"
ROOF_LEVEL
62' -8"
PARAPET_LEVEL
67' -8"
EI-1 EI-2 EI-1AFBR-1 WS-1 AF-1EI-2
BR-1 MP-1 EI-1 EI-2MP-1AF-1
AF-1 LF-1 AS-1
LF-1
MP-1
GLGL
EI-3EI-3
EI-3
01 LEVEL
0' -0"
02 LEVEL
18' -0"
03 LEVEL
29' -2"
04 LEVEL
40' -4"
05 LEVEL
51' -6"
ROOF_LEVEL
62' -8"
PARAPET_LEVEL
67' -8"
EI-2 EI-1 EI-1
EI-2
EI-1 EI-1 EI-1 GLAF-1 GLLF-1EI-3 BR-1 MP-1GLGLEI-1 EI-3 EI-3BR-1 BR-1 WS-1BR-1
SHEET NUMBER
ISSUE DATE
ISSUED FOR
ARCHITECT
D. HAYES HINKLE
TYPE-SIX
DEVELOPMENT SERVICES, LLC
TYPE-SIX
SHEET NAME
REVIEW
THIS DOCUMENT IS
INCOMPLETE AND MAY
NOT BE USED FOR
REGULATORY APPROVAL,
PERMIT, OR
CONSTRUCTION.
D. HAYES HINKLE - 26067
910 SOUTH MAIN STREET #150
GRAPEVINE, TEXAS 76054
972.677.9075
7 /1 5 /2 0 2 4 6 :3 6 :1 3 A M
A5.01
BUILDING ELEVATIONSWHITESTONE HOSPITALITYAC HOTEL BY MARRIOTT7.12.2024 PROJECT # 24021POINT WEST DEVELOPMENT - PD ZONINGLOT 1R-8R, BLOCK C# Revision Date
1/8" = 1'-0"1 EAST ELEVATION
1/8" = 1'-0"2 WEST ELEVATION Administratively Approved on 07/15/2024
EI-1 EIFS -"SW7003 -TOQUE WHITE
MATERIAL CALLOUTS
KING KLINKER -WHITE NIGHT -CHARCOAL GREY -TYPE N MORTARBR-1
SF STOREFRONT -KAWNEER -"DARK BRONZE #40"
EI-3
GL EXTERIOR WINDOWS: STOREFRONT WINDOW SYSTEM
LOUVER FINISH -DARK BRONZE TO MATCH STOREFRONTLF-1
AF-1 ALUMINUM PARAPET FLASHING TO MATCH STOREFRONT
EI-2 EFIS -"SW7054 -MODERN GREY
ADDITIONAL NOTES:
EN-V VS SERIES METAL PANEL -MUSKET GREY
ELEVATION PRECENTAGES
WS-1 CORONADO -BARN WOOD STONE -RUSTIC FARMHOUSE
• ALL SIGNAGE SUBJECT TO BUILDING INSPECTION
DEPARTMENT APPROVAL.
• MECHANICAL UNITS SHALL BE SCREENED IN ACCORDANCE
WITH LOCAL CITY AND ZONING ORDINANCES.
• UTILITY BOXES AND CONDUIT SHALL BE PAINTED TO MATCH
BUILDING COLOR
• ROMAN SIZE, FACE BRICK, WITH 3/8" CONCAVE GROUT
JOINT-MORTAR TO BE MATCHED TO GROUT
• CONTRACTOR TO ENSURE METAL PANELS ARE INSTALLED IN
ACCORDANCE WITH MANUFACTURERS RECOMMENDATION.
• SIGN DESIGNED AND FABRICRATED BY APPROVED VENDOR
TO MEET BRAND STANDARDS, FOR LOCATION ONLY
• ALL UTILITY BOXES AND METERS SHALL BE PAINTED TO MATCH
SURROUNDING BUILDING FACADE.
• FINAL SIGN DESIGN TO BE DRAFTER BY THIRD PARTY
CONTRACTOR TO ENSURE FINAL SIGN PACKAGE IS
SUBMITTED APPROVED BY THE BRAND
MP-1
EFIS -"SW7047 PORPOISE"
NORTH ELEVATION
OVERALL -5,454 TOTAL SQ. FT.
268 SQ. FT. -GLAZING
5,186 SQ. FT. -MASONRY MATERIALS
• EIFS
• STONE
• MASONRY COMPOSITE
PANELS
SOUTH ELEVATION
OVERALL -5,449 TOTAL SQ. FT.
536 SQ. FT. -GLAZING
4,330 SQ. FT. -MASONRY MATERIALS
• EIFS
• STONE
• MASONRY COMPOSITE
PANELS
583 SQ. FT. -METAL PANEL( 9%)
SIGNAGE -100SF
EAST ELEVATION
OVERALL -16,636 TOTAL SQ. FT.
3,622 SQ. FT. -GLAZING
12,391 SQ. FT. -MASONRY MATERIALS
• EIFS
• STONE
• MASONRY COMPOSITE
PANELS
623 SQ. FT. -METAL PANEL(3%)
SIGNAGE -130SF
WEST ELEVATION
OVERALL -16,561 TOTAL SQ. FT.
3,063 SQ. FT. -GLAZING
13,041 SQ. FT. -MASONRY MATERIALS
• EIFS
• STONE
• MASONRY COMPOSITE
PANELS
457 SQ. FT. -METAL PANEL(2.7%)
SIGNAGE -148SF
HIGHWAY COMMERCIAL EXTERIOR CONSTRUCTION REGULATIONS
CORNICE/CAP
3 COLORS MAX.
100% MAX BASE COLOR
5% MAX SECONDARY COLOR & 1% MAX ACCENT COLOR
50% MAX GLAZING PER FACADE
ZONING
YES
YES -3 EIFS COLORS
YES
NO (PREV. APPROVED)
YES
NOTE: ALL ATTACHED BUILDING SIGNAGE WILL COMPLY WITH
THE SIGN SECTION OF THE ZONING ORDINANCE AND WILL BE
PERMITTED SEPARATELY.
01 LEVEL
0' -0"
02 LEVEL
18' -0"
03 LEVEL
29' -2"
04 LEVEL
40' -4"
05 LEVEL
51' -6"
ROOF_LEVEL
62' -8"
PARAPET_LEVEL
67' -8"
AF-1
EI-1BR-1 EI-2 EI-2
EI-1
MP-1 EI-3AF-1
01 LEVEL
0' -0"
02 LEVEL
18' -0"
03 LEVEL
29' -2"
04 LEVEL
40' -4"
05 LEVEL
51' -6"
ROOF_LEVEL
62' -8"
PARAPET_LEVEL
67' -8"
BR-1 EI-1WS-1
BR-1
BR-1EI-2
?
GL AF-1
?AF-1
PD-221R3R5-HC, LOT 1R-8R, BLK C DUKE LESLEY (AC BY MARRIOTT)
CITY OF COPPELL
DALLAS COUNTY, TEXAS 75019
OWNER
WHITESTONE HOSPITALITY, LLC
972.600.8162
PREPARED BY:
TYPE-SIX DESIGN AND DEVELOPMENT
PROJECT CONTACT: CONNOR WALKER, AIA
920 SOUTH MAIN STREET, SUITE 150
GRAPEVINE, TEXAS 76051
AC HOTEL -BY MARRIOTT
SUBMITTAL DATE: 15 JULY 2024
SITE
SITE LOCATION
SHEET NUMBER
ISSUE DATE
ISSUED FOR
ARCHITECT
D. HAYES HINKLE
TYPE-SIX
DEVELOPMENT SERVICES, LLC
TYPE-SIX
SHEET NAME
REVIEW
THIS DOCUMENT IS
INCOMPLETE AND MAY
NOT BE USED FOR
REGULATORY APPROVAL,
PERMIT, OR
CONSTRUCTION.
D. HAYES HINKLE - 26067
910 SOUTH MAIN STREET #150
GRAPEVINE, TEXAS 76054
972.677.9075
7 /1 5 /2 0 2 4 6 :3 7 :1 1 A M
A5.02
BUILDING ELEVATIONSWHITESTONE HOSPITALITYAC HOTEL BY MARRIOTT7.12.2024 PROJECT # 24021POINT WEST DEVELOPMENT - PD ZONINGLOT 1R-8R, BLOCK C# Revision Date
1/8" = 1'-0"1 NORTH ELEVATION
1/8" = 1'-0"2 SOUTH ELEVATION
Administratively Approved on 07/15/2024
Administratively Approved on 07/15/2024
Administratively Approved on 07/15/2024
Administratively Approved on 07/15/2024
Administratively Approved on 07/15/2024
Administratively Approved on 07/15/2024
Administratively Approved on 07/15/2024