Loading...
Exhibit B - Site PlanBARTEL-3859RCH...\HALFF_MON_PENTABLE.TBLPDF_2D_MON_FW_MR_300.pltSheetA:\56000s\56543\001\LD\CADD\Sheets\DSP Sheets\DSP-56543.dgnHALFFah27796:05:17 PM6/24/2024X PP LEGEND 449 FH FDC VICINITY MAP N.T.S. PARKW AY K YLEQUIETVALLEYMORNINGALEXHEATHERGLENEDGEWOODGLENWOODLAKEWOODVAN BEBBER BRAEWOOD SIMMONSAndrew Brown Community Park RI DGEMONTCITY LIMIT LIMIT CITY CLEARWILLOW SPRIN AMBRIACWISE WOODHURSTP ARK MEADOWOAK BROOK SANDYHEARTZ BETHELOAK TRAILSHARONDALEWILLOWAY SANDY LAKEDENTON TAPHARRISFLOWER MOUNDGR AP E VINE C ITY L IMIT C ITY C OP P E L L L IMIT COTTONWOODCOPPELLSTATERU BY KAYE OAK GROVECOPPELLLIMIT MISTY HAVEN TAN BARKALDERWIN DIN G HOLLOWNORTH POINT GATEVIEW CREEKVIEW SANDY LAKE MAGNOL IA ASHLEYRICHMONDBAYOU PLANTATION SPANISH MOSS COOPER SCOTTCOZBY LEISURE SUHMERPLACESANDY LAKE SANDY LAKE CANYON DRIVE S . H. 121 121 121 PROJECT SITE SANITARY SEWER MANHOLE FIRE DEPARTMENT CONNECTION FIRE HYDRANT STORM DRAIN MANHOLE STANDARD 'Y' INLET 10' CURB INLET EXISTING POWER POLE EXISTING FENCE EXISTING CONTOUR EASEMENT LINE LOT LINE PROPERTY LINE FOR BEING A SITUATED IN THE PREPARED BY 9.01 ACRE TRACT CITY OF COPPELL, DALLAS COUNTY, TEXAS JOHN E. HOLLAND SURVEY, ABSTRACT NO. 614 & WHITESTONE HOSPITALITY MCII DEVELOPMENT COMPANY, LLC PD CONDITIONS N SUBMITTED FOR APPROVAL DURING PERMIT PROCESS. 10. SITE LIGHTING SHALL MEET CITY OF COPPELL REQUIREMENTS. FINAL LIGHTING PLANS TO BE 9. FINAL IRRIGATION PLANS TO BE SUMBITTED FOR APPROVAL DURING PERMIT PROCESS 8. BUILDING ELEVATIONS FOR EACH LOT SHALL BE APPROVED AS PRESENTED. 7. MONUMENT SIGN ON LOT 2 WILL ALLOW FOR OFF-PREMISES SIGNAGE FOR LOTS 1, 3 AND 4. 6. PROVIDE FOR ONE 40-FOOT TALL SIGN ON LOT 2 AS SHOWN ON SUBMITTAL DOCUMENTS. 5. FINAL NORTHBOUND ROYAL LANE CONFIGURATION SUBJECT TO CURRENT TIA REQUIREMENTS. THE SOUTHBOUND DIRECTION AND PEDESTRIAN SIGNALS FOR ALL LEGS. TO ACCOMMODATE THE NEW SOUTHBOUND LEG. THIS WILL INCLUDE A NEW TRAFFIC SIGNAL POLE FOR 4. THE EXISTING SIGNAL AT THE INTERSECTION OF SANDY LAKE ROAD AND ROYAL LANE SHALL BE MODIFIED WITH ISSUANCE OF A BUILDING PERMIT FOR THE FIRST BUILDING. INFRASTRUCTURE PLANS AND CONSTRUCTED BY THE OWNER/DEVELOPER PRIOR TO OR CONCURRENT 3. THE ROYAL LANE/SANDY LAKE INTERSECTION IMPROVEMENTS SHALL BE INCLUDED IN THE LOT 1 AND 4 ATTACHED SIGNS WITHIN LOTS 2 AND 3. 2. THERE SHALL BE A COHERENT ARCHITECTURAL THEME AND CONSISTENT SIGN PACKAGE FOR ALL TO AND CONCURRENT WITH ANY DEVELOPMENT ACTIVITY. 1. THIS PROPERTY WILL BE PLATTED TO PROVIDE BUILDING SITES, EASEMENTS, AND FIRE LANES, PRIOR (214) 346-6200 RICHARDSON, TX 75081-2275 1201 NORTH BOWSER ROAD PD CONDITIONS 1 THRU 12 APPROVED IN PD-297-HC/LI, DATED 11/11/2021 LOTS 1, BLOCK A WEST SANDY LAKE ROAD ADDITION II SANDY LAKE - 121 PROPOSED PD CONDITIONS OF THE OVERALL SITE. AFFECTS LOTS 1, 2, 3, AND 4, AND IS DUE TO THE TRIANGULAR CONFIGURATION OFF STREET PARKING LOCATED OUTSIDE THE FRONT YARD. THIS REQUEST 12. REQUEST A VARIANCE FROM HC ZONING REQUIREMENT OF 50% OF REQUIRED 11. THE ELEMENT HOTEL REQUIRED PARKING SHALL BE REDUCED BY ONE PARKING SPACE. ATTACHED SIGNAGE SHALL BE ALLOWED ON PORTE-COCHERE.14. PORTE-COCHERE AT THE SOUTHWEST BUILDING ENTRY THE FRONT YARD SETBACK ON W SANDY LAKE SHALL BE REDUCED TO 34' AT PROPOSED13. SITE DATA TABLE LOT 1 (WAREHOUSE) EXISTING ZONING PD-297R-LI - PROPOSED ZONING - PROPOSED USE WAREHOUSE - TOTAL SITE AREA 9.01 AC TOTAL SITE AREA 392,476 SF BUILDING SQUARE FOOTAGE 124,810 SF WAREHOUSE 52%- OFFICE 12%- UNCONCENTRATED 8%- KITCHEN 8%- SHOWROOM 20%- GROSS FLOOR AREA 130,030 SF BUILDING HEIGHT 40 FT PARKING PROVIDED/REQUIRED 208 / 208 SPACES WAREHOUSE (1000:1)65 SPACES OFFICE (300:1)52 SPACES UNCONCENTRATED (500:1)20 SPACES KITCHEN (500:1)20 SPACES SHOWROOM (500:1)51 SPACES LOT BUILDING COVERAGE 31.80%- FLOOR AREA RATIO 33.13%- PERVIOUS COVER 77,313 SF PERVIOUS COVERAGE 19.70%- IMPERVIOUS COVER 315,163 SF IMPERVIOUS COVERAGE 80.3%- CASE NO. PD-297R2-LI PD CONDITIONS 13 THRU 14 APPROVED IN PD-297R2-LI, DATED 06/11/2024 TOWER OHE TRANSMISSIONFL IN 8" (S) = 510.06 FL OUT 8" (E) = 510.01 FL IN 8" (W) = 510.26 TOP OF RIM = 521.81 SANITARY SEWER MANHOLETOWER OHE TRANSMISSIONFL = 517.05 TOP OF RIM = 527.70 EXISTING STORM CURB INLETFL OUT (S) = 511.21 FL BOX = 511.48 TOP OF RIM = 515.58 EXISTING STORM CURB INLETFL = 511.00 LIP = 515.00 TOP OF RIM = 515.89STORM Y-INLET FH FH FH FHFH FH FDCFHFHFDCFDCFHFH48 4818182112 86 86 6 FHFHFHFHD.R.D.C.T.VOL. 79085, PG. 2171FERGUSON REALTY COMPANY(CALLED 54.769 ACRES)10 10 10 9 12 6 1313 11 11 7 10 5 8 7 11 11 9 6 7 4 3 LP LP 1.56 ACRES LOT 4 FF = 521.00 9,600 SF BUILDING D ZONING: HC FUTURE PHASESANDY LAKE ROADinst. no. 201400150002 227.37' S 00°15'11" E 92.60' N 89°52'07" E 14.62' S 47°54'03" E 136.00' S 47°54'03" E 84.94' S 47°54'03" E 116.42' N 89°52'07" E 538.91' S 01°08'49" E 208.07' S 88°51'11" W117.97' N 47°53'35" WCB= S 0°00'00" ECL= 30.98'L= 31.69'R= 43.00'Δ= 42°1S 42°05'57" W41.00' N 42°05'57" E 41.00' 18.00' S 00°15'11" E DD133655777109101051036871010105108FF = 520.75 124,810 SF BUILDING C 9.01 ACRES LOT 1, BLOCK A 8 3 STATE HIGH WAY 121 INST. NO. 201200116873) STATE OF TEXAS (VARIABLE WIDTH R.O.W. SITE PLAN - LOT 1, BLOCK A NN 41° 58' 59" E 446.86'550.00'1,254.86'S 01° 08' 49" EN 47° 49' 57" E 382.68' BAND CONCRETE 7' STAMPED LANDSCAPE ARCHITECT: ENGINEER: CEL: (214) 984-7321 TEL: (214) 346-6347 EMAIL: PBARTEL@HALFF.COM CONTACT: PAUL D. BARTEL, P.E. RICHARDSON, TX. 75081 1201 NORTH BOWSER ROAD HALFF ASSOCIATES, INC. ARCHITECT: OWNER: CEL: (512) 992-5349 TEL: (737) 309-4703 EMAIL: TFOX@HALFF.COM CONTACT: TOBY FOX AUSTIN, TX. 78729 13620 BRIARWICK DR BUIDLING C SUITE 100 HALFF ASSOCIATES, INC. A - A SIGN EX. MONUMENT EX. FOCAL POINT SCREENWALL EX. 10' ABOVE FINISH FLOOR SCREENWALL EX. 10' ABOVE FINISH FLOOR EX. DUMPSTER AREA RETAINING WALL EXISTING VARIABLE HEIGHT (0' - 10') HEADWALL EXISTING TXDOT RETAINING WALL EXISTING VARIABLE HEIGHT (0' - 3') 3 CEL: (214) 695-3616 TEL: EMAIL: KEVIN.CLARK@WELBILT.COM CONTACT: KEVIN CLARK VERNON HILLS, IL 60061 101 CORPORATE WOODS PKWY. WELBUILT, INC. CEL: (469) 657-7080 TEL: (972) 419-3964 EMAIL: CVAUGHN@ENTOSDESIGN.COM CONTACT: COLTON VAUGHN, RID DALLAS, TX 75240 5400 LYNDON B. JOHNSON FWY, SUITE 125 ENTOS DESIGN ZONING: LI 2 x 12'x14' DOCK DOORS 33 x 9'x10' DOCK DOORS (ACTUAL NUMBER OF SPACES = 208) 20% SHOWROOM = 51 SPACES 8% KITCHEN = 20 SPACES 8% UNCONCENTRATED = 20 SPACES 12% OFFICE = 52 SPACES 52% WAREHOUSE = 65 SPACESTSPHOME 2 SUITES BYHILTON126 ROOMS5 STORY133 PARKING SPACES2.85 ACRESLOT 2, BLOCK AZONING: HC 60' BUILDING SETBACKD.R.D.C.T. VOL. 2005005, PG. 70 10' BUILDING LINE D.R.D.C.T. VOL. 2005005, PG. 70 ONCOR 15' EASEMENT D.R.D.C.T. VOL. 2005005, PG. 70 EASEMENT PRIVATE DRAINAGE (O.P.R.D.C.T.)(INST. NO. 20140015002)(PARCEL II) (STATE OF TEXAS)(CALLED 6.925 ACRES) ACCESS EASEMENT VARIABLE WIDTH MUTUAL EASEMENTACCESS34' MUTUALEASEMENT26' FIRE LANEEASEMENTACCESS25' MUTUALEASEMENT 20' WATER EASEMENT20' WATER EASEMENTACCESS25' MUTUALEASEMENT26' FIRE LANEEASEMENT 24' FIRE LANE EASEMENT 24' FIRE LANE EASEMENT 26' FIRE LANE EASEMENT26' FIRE LANEEASEMENT 26' FIRE LANE EASEMENT30' FIRE LANEEASE MENT 30' FIRE LANE EASEMENT M UTUAL ACCESS VARIABLE WIDTH EASEMENT 40' FIRE LANE EASEMENT 10' PRIVATE SEWER 15' WATER EASEMENT D.R.D.C.T. VOL. 86153, PG. 1282 T.P.&L. EASEMENT AND SIDEWALK EASEMENT VARIABLE WIDTH STREET 20' REAR SETBACK (HC) 30' SIDE SETBACK SETBACK 60' FRONT SETBACK 60' FRONT 10' REAR SETBACK (LI) 60' FRONT SETBACK 1210'18'26'18'10'18'111'109' 9' 49'60'(TYP) 52'(TYP) 50'8'26'18'5' SIDEWALK5'R 10'18'26'38'24'18'9'10'RDISTANCE TO ADJACENT DRIVEWAY: 323'50'150'618'10'10'20'26'84'210'18' 132'140'9'49' 92' 20'62'10'10'80'40'82'26'109'5' SIDEWALK234' 325' 100' 30'R 30'R 70'RDRIVEWAY: 136'DISTANCE TO ADJANCENT806040200 SCALE: 1"=40' AND COMPACTOR ENCLOSURE W/ DUMPSTER PROPOSED DUMPSTER 50.5'22'83'11'9'SIGN PROPOSED MONUMENT 18'(5' X 22') PROPOSED 3" SPEED TABLE (5' X 22') PROPOSED 3" SPEED TABLEAA22'5'3"5' SPEED TABLE DETAIL N.T.S. (APPROVED BY PD) FUTURE MONUMENT SIGN 40'27' 18' UNITS PROPOSED DOAS UNITS PROPOSED DOAS W/ INTERIOR LIGHTING CANOPY STRUCTURE PROPOSED BUILDING W/ INTERIOR LIGHTING CANOPY STRUCTURE PROPOSED BUILDING PROPOSED SECURITY FENCE speed humps to prevent cut through traffic. elevation, add a portacachere to the southwest corner, and add two screening, add a canopy structure to the northwest corner of the front The purpose of this Site Plan Amendment is to add generator and Purpose Statement: FROM BUILDING OPENINGS ENSURE PROPER CLEARENCES PAD/ENCLOSURE POWERED GENERATOR PROPOSED EMERGENCY DIESEL