Exhibit B - Site PlanBARTEL-3859RCH...\HALFF_MON_PENTABLE.TBLPDF_2D_MON_FW_MR_300.pltSheetA:\56000s\56543\001\LD\CADD\Sheets\DSP Sheets\DSP-56543.dgnHALFFah27796:05:17 PM6/24/2024X
PP
LEGEND
449
FH
FDC
VICINITY MAP
N.T.S.
PARKW AY
K
YLEQUIETVALLEYMORNINGALEXHEATHERGLENEDGEWOODGLENWOODLAKEWOODVAN
BEBBER
BRAEWOOD SIMMONSAndrew Brown
Community Park RI
DGEMONTCITY
LIMIT
LIMIT
CITY
CLEARWILLOW
SPRIN
AMBRIACWISE
WOODHURSTP
ARK MEADOWOAK
BROOK
SANDYHEARTZ BETHELOAK TRAILSHARONDALEWILLOWAY
SANDY LAKEDENTON TAPHARRISFLOWER MOUNDGR AP E VINE
C ITY L IMIT
C ITY
C OP P E L L
L IMIT
COTTONWOODCOPPELLSTATERU
BY
KAYE
OAK GROVECOPPELLLIMIT
MISTY HAVEN
TAN BARKALDERWIN DIN G HOLLOWNORTH POINT
GATEVIEW
CREEKVIEW
SANDY LAKE
MAGNOL IA
ASHLEYRICHMONDBAYOU
PLANTATION
SPANISH MOSS
COOPER
SCOTTCOZBY
LEISURE
SUHMERPLACESANDY LAKE
SANDY LAKE
CANYON DRIVE
S . H. 121
121
121 PROJECT
SITE
SANITARY SEWER MANHOLE
FIRE DEPARTMENT CONNECTION
FIRE HYDRANT
STORM DRAIN MANHOLE
STANDARD 'Y' INLET
10' CURB INLET
EXISTING POWER POLE
EXISTING FENCE
EXISTING CONTOUR
EASEMENT LINE
LOT LINE
PROPERTY LINE
FOR
BEING A
SITUATED IN THE
PREPARED BY
9.01 ACRE TRACT
CITY OF COPPELL, DALLAS COUNTY, TEXAS
JOHN E. HOLLAND SURVEY, ABSTRACT NO. 614
& WHITESTONE HOSPITALITY
MCII DEVELOPMENT COMPANY, LLC
PD CONDITIONS
N
SUBMITTED FOR APPROVAL DURING PERMIT PROCESS.
10. SITE LIGHTING SHALL MEET CITY OF COPPELL REQUIREMENTS. FINAL LIGHTING PLANS TO BE
9. FINAL IRRIGATION PLANS TO BE SUMBITTED FOR APPROVAL DURING PERMIT PROCESS
8. BUILDING ELEVATIONS FOR EACH LOT SHALL BE APPROVED AS PRESENTED.
7. MONUMENT SIGN ON LOT 2 WILL ALLOW FOR OFF-PREMISES SIGNAGE FOR LOTS 1, 3 AND 4.
6. PROVIDE FOR ONE 40-FOOT TALL SIGN ON LOT 2 AS SHOWN ON SUBMITTAL DOCUMENTS.
5. FINAL NORTHBOUND ROYAL LANE CONFIGURATION SUBJECT TO CURRENT TIA REQUIREMENTS.
THE SOUTHBOUND DIRECTION AND PEDESTRIAN SIGNALS FOR ALL LEGS.
TO ACCOMMODATE THE NEW SOUTHBOUND LEG. THIS WILL INCLUDE A NEW TRAFFIC SIGNAL POLE FOR
4. THE EXISTING SIGNAL AT THE INTERSECTION OF SANDY LAKE ROAD AND ROYAL LANE SHALL BE MODIFIED
WITH ISSUANCE OF A BUILDING PERMIT FOR THE FIRST BUILDING.
INFRASTRUCTURE PLANS AND CONSTRUCTED BY THE OWNER/DEVELOPER PRIOR TO OR CONCURRENT
3. THE ROYAL LANE/SANDY LAKE INTERSECTION IMPROVEMENTS SHALL BE INCLUDED IN THE LOT 1 AND 4
ATTACHED SIGNS WITHIN LOTS 2 AND 3.
2. THERE SHALL BE A COHERENT ARCHITECTURAL THEME AND CONSISTENT SIGN PACKAGE FOR ALL
TO AND CONCURRENT WITH ANY DEVELOPMENT ACTIVITY.
1. THIS PROPERTY WILL BE PLATTED TO PROVIDE BUILDING SITES, EASEMENTS, AND FIRE LANES, PRIOR
(214) 346-6200
RICHARDSON, TX 75081-2275
1201 NORTH BOWSER ROAD
PD CONDITIONS 1 THRU 12 APPROVED IN PD-297-HC/LI, DATED 11/11/2021
LOTS 1, BLOCK A
WEST SANDY LAKE ROAD ADDITION II
SANDY LAKE - 121
PROPOSED PD CONDITIONS
OF THE OVERALL SITE.
AFFECTS LOTS 1, 2, 3, AND 4, AND IS DUE TO THE TRIANGULAR CONFIGURATION
OFF STREET PARKING LOCATED OUTSIDE THE FRONT YARD. THIS REQUEST
12. REQUEST A VARIANCE FROM HC ZONING REQUIREMENT OF 50% OF REQUIRED
11. THE ELEMENT HOTEL REQUIRED PARKING SHALL BE REDUCED BY ONE PARKING SPACE.
ATTACHED SIGNAGE SHALL BE ALLOWED ON PORTE-COCHERE.14.
PORTE-COCHERE AT THE SOUTHWEST BUILDING ENTRY
THE FRONT YARD SETBACK ON W SANDY LAKE SHALL BE REDUCED TO 34' AT PROPOSED13.
SITE DATA TABLE
LOT 1 (WAREHOUSE)
EXISTING ZONING PD-297R-LI -
PROPOSED ZONING -
PROPOSED USE WAREHOUSE -
TOTAL SITE AREA 9.01 AC
TOTAL SITE AREA 392,476 SF
BUILDING SQUARE FOOTAGE 124,810 SF
WAREHOUSE 52%-
OFFICE 12%-
UNCONCENTRATED 8%-
KITCHEN 8%-
SHOWROOM 20%-
GROSS FLOOR AREA 130,030 SF
BUILDING HEIGHT 40 FT
PARKING PROVIDED/REQUIRED 208 / 208 SPACES
WAREHOUSE (1000:1)65 SPACES
OFFICE (300:1)52 SPACES
UNCONCENTRATED (500:1)20 SPACES
KITCHEN (500:1)20 SPACES
SHOWROOM (500:1)51 SPACES
LOT BUILDING COVERAGE 31.80%-
FLOOR AREA RATIO 33.13%-
PERVIOUS COVER 77,313 SF
PERVIOUS COVERAGE 19.70%-
IMPERVIOUS COVER 315,163 SF
IMPERVIOUS COVERAGE 80.3%-
CASE NO. PD-297R2-LI
PD CONDITIONS 13 THRU 14 APPROVED IN PD-297R2-LI, DATED 06/11/2024
TOWER OHE TRANSMISSIONFL IN 8" (S) = 510.06 FL OUT 8" (E) = 510.01 FL IN 8" (W) = 510.26 TOP OF RIM = 521.81 SANITARY SEWER MANHOLETOWER OHE TRANSMISSIONFL = 517.05 TOP OF RIM = 527.70 EXISTING STORM CURB INLETFL OUT (S) = 511.21 FL BOX = 511.48 TOP OF RIM = 515.58 EXISTING STORM CURB INLETFL = 511.00 LIP = 515.00 TOP OF RIM = 515.89STORM Y-INLET FH FH
FH
FHFH
FH
FDCFHFHFDCFDCFHFH48
4818182112
86
86
6
FHFHFHFHD.R.D.C.T.VOL. 79085, PG. 2171FERGUSON REALTY COMPANY(CALLED 54.769 ACRES)10
10
10
9
12
6
1313
11 11
7 10
5 8
7
11
11
9
6
7
4
3
LP LP
1.56 ACRES
LOT 4
FF = 521.00
9,600 SF
BUILDING D
ZONING: HC
FUTURE PHASESANDY LAKE ROADinst. no. 201400150002
227.37' S 00°15'11" E 92.60' N 89°52'07" E 14.62' S 47°54'03" E 136.00' S 47°54'03" E
84.94' S 47°54'03" E
116.42' N 89°52'07" E 538.91' S 01°08'49" E
208.07' S 88°51'11" W117.97' N 47°53'35" WCB= S 0°00'00" ECL= 30.98'L= 31.69'R= 43.00'Δ= 42°1S 42°05'57" W41.00'
N 42°05'57" E
41.00'
18.00'
S 00°15'11" E DD133655777109101051036871010105108FF = 520.75
124,810 SF
BUILDING C
9.01 ACRES
LOT 1, BLOCK A
8
3
STATE HIGH
WAY 121
INST. NO. 201200116873)
STATE OF TEXAS
(VARIABLE WIDTH R.O.W.
SITE PLAN - LOT 1, BLOCK A NN 41° 58' 59" E 446.86'550.00'1,254.86'S 01° 08' 49" EN 47° 49' 57" E 382.68'
BAND
CONCRETE
7' STAMPED
LANDSCAPE ARCHITECT:
ENGINEER:
CEL: (214) 984-7321
TEL: (214) 346-6347
EMAIL: PBARTEL@HALFF.COM
CONTACT: PAUL D. BARTEL, P.E.
RICHARDSON, TX. 75081
1201 NORTH BOWSER ROAD
HALFF ASSOCIATES, INC.
ARCHITECT:
OWNER:
CEL: (512) 992-5349
TEL: (737) 309-4703
EMAIL: TFOX@HALFF.COM
CONTACT: TOBY FOX
AUSTIN, TX. 78729
13620 BRIARWICK DR BUIDLING C SUITE 100
HALFF ASSOCIATES, INC.
A - A
SIGN
EX. MONUMENT
EX. FOCAL POINT
SCREENWALL
EX. 10' ABOVE FINISH FLOOR
SCREENWALL
EX. 10' ABOVE FINISH FLOOR
EX. DUMPSTER AREA
RETAINING WALL
EXISTING VARIABLE HEIGHT (0' - 10')
HEADWALL
EXISTING TXDOT
RETAINING WALL
EXISTING VARIABLE HEIGHT (0' - 3')
3
CEL: (214) 695-3616
TEL:
EMAIL: KEVIN.CLARK@WELBILT.COM
CONTACT: KEVIN CLARK
VERNON HILLS, IL 60061
101 CORPORATE WOODS PKWY.
WELBUILT, INC.
CEL: (469) 657-7080
TEL: (972) 419-3964
EMAIL: CVAUGHN@ENTOSDESIGN.COM
CONTACT: COLTON VAUGHN, RID
DALLAS, TX 75240
5400 LYNDON B. JOHNSON FWY, SUITE 125
ENTOS DESIGN
ZONING: LI
2 x 12'x14' DOCK DOORS
33 x 9'x10' DOCK DOORS
(ACTUAL NUMBER OF SPACES = 208)
20% SHOWROOM = 51 SPACES
8% KITCHEN = 20 SPACES
8% UNCONCENTRATED = 20 SPACES
12% OFFICE = 52 SPACES
52% WAREHOUSE = 65 SPACESTSPHOME 2 SUITES BYHILTON126 ROOMS5 STORY133 PARKING SPACES2.85 ACRESLOT 2, BLOCK AZONING: HC
60' BUILDING SETBACKD.R.D.C.T.
VOL. 2005005, PG. 70
10' BUILDING LINE
D.R.D.C.T.
VOL. 2005005, PG. 70
ONCOR 15' EASEMENT
D.R.D.C.T.
VOL. 2005005, PG. 70
EASEMENT
PRIVATE DRAINAGE
(O.P.R.D.C.T.)(INST. NO. 20140015002)(PARCEL II) (STATE OF TEXAS)(CALLED 6.925 ACRES)
ACCESS EASEMENT
VARIABLE WIDTH MUTUAL EASEMENTACCESS34' MUTUALEASEMENT26' FIRE LANEEASEMENTACCESS25' MUTUALEASEMENT
20' WATER EASEMENT20' WATER EASEMENTACCESS25' MUTUALEASEMENT26' FIRE LANEEASEMENT
24' FIRE LANE
EASEMENT
24' FIRE LANE
EASEMENT
26' FIRE LANE
EASEMENT26' FIRE LANEEASEMENT
26' FIRE LANE EASEMENT30' FIRE LANEEASE
MENT
30' FIRE LANE
EASEMENT
M UTUAL ACCESS
VARIABLE WIDTH
EASEMENT
40' FIRE LANE
EASEMENT
10' PRIVATE SEWER
15' WATER EASEMENT
D.R.D.C.T.
VOL. 86153, PG. 1282
T.P.&L. EASEMENT
AND SIDEWALK EASEMENT
VARIABLE WIDTH STREET
20' REAR SETBACK (HC)
30' SIDE SETBACK
SETBACK
60' FRONT
SETBACK
60' FRONT
10' REAR SETBACK (LI)
60' FRONT SETBACK
1210'18'26'18'10'18'111'109'
9'
49'60'(TYP)
52'(TYP) 50'8'26'18'5' SIDEWALK5'R
10'18'26'38'24'18'9'10'RDISTANCE TO ADJACENT DRIVEWAY: 323'50'150'618'10'10'20'26'84'210'18'
132'140'9'49'
92'
20'62'10'10'80'40'82'26'109'5' SIDEWALK234'
325'
100'
30'R
30'R
70'RDRIVEWAY: 136'DISTANCE TO ADJANCENT806040200
SCALE: 1"=40'
AND COMPACTOR
ENCLOSURE W/ DUMPSTER
PROPOSED DUMPSTER
50.5'22'83'11'9'SIGN
PROPOSED MONUMENT
18'(5' X 22')
PROPOSED 3" SPEED TABLE
(5' X 22')
PROPOSED 3" SPEED TABLEAA22'5'3"5'
SPEED TABLE DETAIL
N.T.S.
(APPROVED BY PD)
FUTURE MONUMENT SIGN
40'27'
18'
UNITS
PROPOSED DOAS
UNITS
PROPOSED DOAS
W/ INTERIOR LIGHTING
CANOPY STRUCTURE
PROPOSED BUILDING
W/ INTERIOR LIGHTING
CANOPY STRUCTURE
PROPOSED BUILDING
PROPOSED SECURITY FENCE
speed humps to prevent cut through traffic.
elevation, add a portacachere to the southwest corner, and add two
screening, add a canopy structure to the northwest corner of the front
The purpose of this Site Plan Amendment is to add generator and
Purpose Statement:
FROM BUILDING OPENINGS
ENSURE PROPER CLEARENCES
PAD/ENCLOSURE
POWERED GENERATOR
PROPOSED EMERGENCY DIESEL