Loading...
Welbilt_Civil_Preliminary Engineering Plan_v1 (2)BARTEL-3859RCH...\V8i\PlotTables\PENTABLE.TBLPDF_2D_MON_FW_MR_300.pltSheetA:\56000s\56543\001\LD\CADD\Sheets\DSP Sheets\PEP-56543.dgnHALFFah27793:06:54 PM4/12/2024X PP LEGEND 449 FH FDC VICINITY MAP N.T.S. PARKW AY K YLEQUIETVALLEYMORNINGALEXHEATHERGLENEDGEWOODGLENWOODLAKEWOODVAN BEBBER BRAEWOOD SIMMONSAndrew Brown Community Park RI DGEMONTCITY LIMIT LIMIT CITY CLEARWILLOW SPRIN AMBRIACWISE WOODHURSTP ARK MEADOWOAK BROOK SANDYHEARTZ BETHELOAK TRAILSHARONDALEWILLOWAY SANDY LAKEDENTON TAPHARRISFLOWER MOUNDGR AP E VINE C ITY L IMIT C ITY C OP P E L L L IMIT COTTONWOODCOPPELLSTATERU BY KAYE OAK GROVECOPPELLLIMIT MISTY HAVEN TAN BARKALDERWIN DIN G HOLLOWNORTH POINT GATEVIEW CREEKVIEW SANDY LAKE MAGNOL IA ASHLEYRICHMONDBAYOU PLANTATION SPANISH MOSS COOPER SCOTTCOZBY LEISURE SUHMERPLACESANDY LAKE SANDY LAKE CANYON DRIVE S . H. 121 121 121 PROJECT SITE PROPERTY LINE LOT LINE EASEMENT LINE EXISTING CONTOUR EXISTING FENCE EXISTING POWER POLE 10' CURB INLET STANDARD 'Y' INLET STORM DRAIN MANHOLE FIRE HYDRANT FIRE DEPARTMENT CONNECTION SANITARY SEWER MANHOLE FOR BEING A SITUATED IN THE PREPARED BY CASE NO. SPXX-XXXX 9.01 ACRE TRACT CITY OF COPPELL, DALLAS COUNTY, TEXAS JOHN E. HOLLAND SURVEY, ABSTRACT NO. 614 & WHITESTONE HOSPITALITY MCII DEVELOPMENT COMPANY, LLC LIST OF VARIANCES PD CONDITIONS N 1. THE ELEMENT HOTEL REQUIRED PARKING SHALL BE REDUCED BY ONE PARKING SPACE. 2. REQUEST A VARIANCE FROM HC ZONING REQUIREMENT OF 50% OF REQUIRED OFF STREET PARKING LOCATED OUTSIDE THE FRONT YARD. THIS REQUEST AFFECTS LOTS 1, 2, 3, AND 4, AND IS DUE TO THE TRIANGULAR CONFIGURATION OF THE OVERALL SITE. 1. THIS PROPERTY WILL BE PLATTED TO PROVIDE BUILDING SITES, EASEMENTS, AND FIRE LANES, PRIOR TO AND CONCURRENT WITH ANY DEVELOPMENT ACTIVITY. 2. THERE SHALL BE A COHERENT ARCHITECTURAL THEME AND CONSISTENT SIGN PACKAGE FOR ALL ATTACHED SIGNS WITHIN LOTS 2 AND 3. 3. THE ROYAL LANE/SANDY LAKE INTERSECTION IMPROVEMENTS SHALL BE INCLUDED IN THE LOT 1 AND 4 INFRASTRUCTURE PLANS AND CONSTRUCTED BY THE OWNER/DEVELOPER PRIOR TO OR CONCURRENT WITH ISSUANCE OF A BUILDING PERMIT FOR THE FIRST BUILDING. 4. THE EXISTING SIGNAL AT THE INTERSECTION OF SANDY LAKE ROAD AND ROYAL LANE SHALL BE MODIFIED TO ACCOMMODATE THE NEW SOUTHBOUND LEG. THIS WILL INCLUDE A NEW TRAFFIC SIGNAL POLE FOR THE SOUTHBOUND DIRECTION AND PEDESTRIAN SIGNALS FOR ALL LEGS. 5. FINAL NORTHBOUND ROYAL LANE CONFIGURATION SUBJECT TO CURRENT TIA REQUIREMENTS. 6. PROVIDE FOR ONE 40-FOOT TALL SIGN ON LOT 2 AS SHOWN ON SUBMITTAL DOCUMENTS. 7. MONUMENT SIGN ON LOT 2 WILL ALLOW FOR OFF-PREMISES SIGNAGE FOR LOTS 1, 3 AND 4. 8. BUILDING ELEVATIONS FOR EACH LOT SHALL BE APPROVED AS PRESENTED. 9. FINAL IRRIGATION PLANS TO BE SUMBITTED FOR APPROVAL DURING PERMIT PROCESS 10. SITE LIGHTING SHALL MEET CITY OF COPPELL REQUIREMENTS. FINAL LIGHTING PLANS TO BE SUBMITTED FOR APPROVAL DURING PERMIT PROCESS. SITE DATA TABLE LOT 1 (WAREHOUSE) EXISTING ZONING PD-297R-LI - PROPOSED ZONING - PROPOSED USE WAREHOUSE - TOTAL SITE AREA 9.01 AC TOTAL SITE AREA 392,476 SF BUILDING SQUARE FOOTAGE 130,698 SF WAREHOUSE 50%- OFFICE 16%- UNCONCENTRATED 8%- KITCHEN 7%- SHOWROOM 19%- GROSS FLOOR AREA 130,030 SF BUILDING HEIGHT 40 FT PARKING PROVIDED/REQUIRED 228 / 228 SPACES WAREHOUSE (1000:1)65 SPACES OFFICE (300:1)72 SPACES UNCONCENTRATED (500:1)21 SPACES KITCHEN (500:1)19 SPACES SHOWROOM (500:1)51 SPACES LOT BUILDING COVERAGE 33.30%- FLOOR AREA RATIO 33.13%- PERVIOUS COVER 77,313 SF PERVIOUS COVERAGE 19.70%- IMPERVIOUS COVER 315,163 SF IMPERVIOUS COVERAGE 80.3%- (214) 346-6200 RICHARDSON, TX 75081-2275 1201 NORTH BOWSER ROAD 3. REQUEST A VARIANCE FROM 60' SIDE YARD SETBACK TO BE REDUCED TO 34' AT PROPOSED PORTE COCHERE AT SOUTHWEST BUILDING ENTRY. PROPOSED VARIANCE PD CONDITIONS 1 THRU 10 APPROVED IN PD-297-HC/LI, DATED 11/11/2021 VARIANCES 1-2 APPROVED IN PD-297-HC/LI, DATED 11/11/2021 LOTS 1, BLOCK A WEST SANDY LAKE ROAD ADDITION II SANDY LAKE - 121 TOWER OHE TRANSMISSIONFL IN 8" (S) = 510.06 FL OUT 8" (E) = 510.01 FL IN 8" (W) = 510.26 TOP OF RIM = 521.81 SANITARY SEWER MANHOLETOWER OHE TRANSMISSIONFL = 517.05 TOP OF RIM = 527.70 EXISTING STORM CURB INLETFL OUT (S) = 511.21 FL BOX = 511.48 TOP OF RIM = 515.58 EXISTING STORM CURB INLETFL = 511.00 LIP = 515.00 TOP OF RIM = 515.89STORM Y-INLET TSSIGNAL POLE EXISTING TRAFFIC TT TTTT TT TT TTTTTTTTTTTTTTFHFHTT7'x2'24" RCP21" RCP21" RCP FH FH FH FHFH FH T T21" RCP @ 0.75%21" RCP @ 0.75%24" RCP @ 0.75%@ 0.20%RCB48" RCP @ 0.20%@ 0.20%6'x2' RCP42" RCP @ 0.20%42" RCP @ 0.20%30" RCP @ 0.20% FDC 24" RCP @ 1.55%TFHFH FHFDCFDCFHFHDD161336557211677109101051036871010105108484818182112 86 86 6 FHFHFHFH10 10 10 9 12 6 1313 11 11 7 10 5 8 7 11 11 9 6 7 4 3 LP LP 1.56 ACRES LOT 4 FF = 521.00 9,600 SF BUILDING D ZONING: HC FUTURE PHASESANDY LAKE ROADDD161336557211677109101051036871010105108FF = 520.75 130,698 SF BUILDING C 9.01 ACRES LOT 1, BLOCK A 6 10 12 inst. no. 201400150002 227.37' S 00°15'11" E 92.60' N 89°52'07" E 136.00' S 47°54'03" E 84.94' S 47°54'03" E 116.42' N 89°52'07" E 538.91' S 01°08'49" E 208.07' S 88°51'11" W117.97' N 47°53'35" WS 42°05'57" W41.00' N 42°05'57" E 41.00' 18.00' S 00°15'11" E 10008 10007 10006 10000 14.62' S 47°54'03" E CB= S 0°00'00" E CL= 30.98' L= 31.69' R= 43.00' Δ= 42°1 LANDSCAPE ARCHITECT: STATE HIGH WAY 121 INST. NO. 201200116873) STATE OF TEXAS (VARIABLE WIDTH R.O.W.NN 41° 58' 59" E 446.86'550.00'1,254.86'S 01° 08' 49" EN 47° 49' 57" E 382.68'ENGINEER: CEL: (214) 984-7321 TEL: (214) 346-6347 EMAIL: PBARTEL@HALFF.COM CONTACT: PAUL D. BARTEL, P.E. RICHARDSON, TX. 75081 1201 NORTH BOWSER ROAD HALFF ASSOCIATES, INC. ARCHITECT: OWNER: CEL: (512) 992-5349 TEL: (737) 309-4703 EMAIL: TFOX@HALFF.COM CONTACT: TOBY FOX AUSTIN, TX. 78729 13620 BRIARWICK DR BUIDLING C SUITE 100 HALFF ASSOCIATES, INC. PRELIMINARY ENG. - LOT 1, BLOCK A CEL: (214) 695-3616 TEL: EMAIL: KEVIN.CLARK@WELBILT.COM CONTACT: KEVIN CLARK VERNON HILLS, IL 60061 101 CORPORATE WOODS PKWY. WELBUILT, INC. CEL: (469) 657-7080 TEL: (972) 419-3964 EMAIL: CVAUGHN@ENTOSDESIGN.COM CONTACT: COLTON VAUGHN, RID DALLAS, TX 75240 5400 LYNDON B. JOHNSON FWY, SUITE 125 ENTOS DESIGN ZONING: LI 2 x 12'x14' DOCK DOORS 33 x 9'x10' DOCK DOORS (ACTUAL NUMBER OF SPACES = 228) 19% SHOWROOM = 51 SPACES 7% KITCHEN = 19 SPACES 8% UNCONCENTRATED = 21 SPACES 16% OFFICE = 72 SPACES 50% WAREHOUSE = 65 SPACESELEMENT HOTEL BYMARRIOTT125 ROOMS5 STORY132 PARKING SPACESHOME 2 SUITES BYHILTON126 ROOMS5 STORY133 PARKING SPACES2.85 ACRESLOT 2, BLOCK A3.16 ACRESLOT 3, BLOCK AZONING: HC TSPELEMENT HOTEL BYMARRIOTT125 ROOMS5 STORY132 PARKING SPACESHOME 2 SUITES BYHILTON126 ROOMS5 STORY133 PARKING SPACES2.85 ACRESLOT 2, BLOCK A3.16 ACRESLOT 3, BLOCK AZONING: HC 60' BUILDING SETBACK D.R.D.C.T. VOL. 2005005, PG. 70 10' BUILDING LINE D.R.D.C.T. VOL. 2005005, PG. 70 ONCOR 15' EASEMENT D.R.D.C.T. VOL. 2005005, PG. 70 EASEMENT PRIVATE DRAINAGE (O.P.R.D.C.T.)(INST. NO. 20140015002)(PARCEL II) (STATE OF TEXAS)(CALLED 6.925 ACRES) ACCESS EASEMENT VARIABLE WIDTH MUTUAL EASEMENT 20' WATER EASEMENT 24' FIRE LANE EASEMENT 24' FIRE LANE EASEMENT 26' FIRE LANE EASEMENT 26' FIRE LANE EASEMENT 40' FIRE LANE EASEMENT 10' PRIVATE SEWER 15' WATER EASEMENT D.R.D.C.T. VOL. 86153, PG. 1282 T.P.&L. EASEMENT AND SIDEWALK EASEMENT VARIABLE WIDTH STREET 20' REAR SETBACK (HC) 30' SIDE SETBACK 10' REAR SETBACK (LI) EASEMENT 20' WATER EASEMENT 26' FIRE LANE SETBACK 60' FRONT EASEMENT 30' FIRE LANE SETBACK 60' FRONT EASEMENT 30' FIRE LANE EASEMENT MUTUAL ACCESS VARIABLE WIDTH EASEMENT 26' FIRE LANE EASEMENT 26' FIRE LANE EASEMENT 24' FIRE LANE EASEMENT ACCESS 25' MUTUAL EASEMENT ACCESS 34' MUTUAL EASEMENT ACCESS 25' MUTUAL 60' FRONT SETBACK 806040200 SCALE: 1"=40' TRAP PROPOSED GREASE AND REPLACED TO BE REMOVED EX. TRANSFORMER PROPOSED BACKUP GENERATOR UNITS (TYP.) PROPOSED DOAS