Welbilt_Civil_Preliminary Engineering Plan_v1 (2)BARTEL-3859RCH...\V8i\PlotTables\PENTABLE.TBLPDF_2D_MON_FW_MR_300.pltSheetA:\56000s\56543\001\LD\CADD\Sheets\DSP Sheets\PEP-56543.dgnHALFFah27793:06:54 PM4/12/2024X
PP
LEGEND
449
FH
FDC
VICINITY MAP
N.T.S.
PARKW AY
K
YLEQUIETVALLEYMORNINGALEXHEATHERGLENEDGEWOODGLENWOODLAKEWOODVAN
BEBBER
BRAEWOOD SIMMONSAndrew Brown
Community Park RI
DGEMONTCITY
LIMIT
LIMIT
CITY
CLEARWILLOW
SPRIN
AMBRIACWISE
WOODHURSTP
ARK MEADOWOAK
BROOK
SANDYHEARTZ BETHELOAK TRAILSHARONDALEWILLOWAY
SANDY LAKEDENTON TAPHARRISFLOWER MOUNDGR AP E VINE
C ITY L IMIT
C ITY
C OP P E L L
L IMIT
COTTONWOODCOPPELLSTATERU
BY
KAYE
OAK GROVECOPPELLLIMIT
MISTY HAVEN
TAN BARKALDERWIN DIN G HOLLOWNORTH POINT
GATEVIEW
CREEKVIEW
SANDY LAKE
MAGNOL IA
ASHLEYRICHMONDBAYOU
PLANTATION
SPANISH MOSS
COOPER
SCOTTCOZBY
LEISURE
SUHMERPLACESANDY LAKE
SANDY LAKE
CANYON DRIVE
S . H. 121
121
121 PROJECT
SITE
PROPERTY LINE
LOT LINE
EASEMENT LINE
EXISTING CONTOUR
EXISTING FENCE
EXISTING POWER POLE
10' CURB INLET
STANDARD 'Y' INLET
STORM DRAIN MANHOLE
FIRE HYDRANT
FIRE DEPARTMENT CONNECTION
SANITARY SEWER MANHOLE
FOR
BEING A
SITUATED IN THE
PREPARED BY
CASE NO. SPXX-XXXX
9.01 ACRE TRACT
CITY OF COPPELL, DALLAS COUNTY, TEXAS
JOHN E. HOLLAND SURVEY, ABSTRACT NO. 614
& WHITESTONE HOSPITALITY
MCII DEVELOPMENT COMPANY, LLC
LIST OF VARIANCES
PD CONDITIONS
N
1. THE ELEMENT HOTEL REQUIRED PARKING SHALL BE REDUCED BY ONE PARKING SPACE.
2. REQUEST A VARIANCE FROM HC ZONING REQUIREMENT OF 50% OF REQUIRED
OFF STREET PARKING LOCATED OUTSIDE THE FRONT YARD. THIS REQUEST
AFFECTS LOTS 1, 2, 3, AND 4, AND IS DUE TO THE TRIANGULAR CONFIGURATION
OF THE OVERALL SITE.
1. THIS PROPERTY WILL BE PLATTED TO PROVIDE BUILDING SITES, EASEMENTS, AND FIRE LANES, PRIOR
TO AND CONCURRENT WITH ANY DEVELOPMENT ACTIVITY.
2. THERE SHALL BE A COHERENT ARCHITECTURAL THEME AND CONSISTENT SIGN PACKAGE FOR ALL
ATTACHED SIGNS WITHIN LOTS 2 AND 3.
3. THE ROYAL LANE/SANDY LAKE INTERSECTION IMPROVEMENTS SHALL BE INCLUDED IN THE LOT 1 AND 4
INFRASTRUCTURE PLANS AND CONSTRUCTED BY THE OWNER/DEVELOPER PRIOR TO OR CONCURRENT
WITH ISSUANCE OF A BUILDING PERMIT FOR THE FIRST BUILDING.
4. THE EXISTING SIGNAL AT THE INTERSECTION OF SANDY LAKE ROAD AND ROYAL LANE SHALL BE MODIFIED
TO ACCOMMODATE THE NEW SOUTHBOUND LEG. THIS WILL INCLUDE A NEW TRAFFIC SIGNAL POLE FOR
THE SOUTHBOUND DIRECTION AND PEDESTRIAN SIGNALS FOR ALL LEGS.
5. FINAL NORTHBOUND ROYAL LANE CONFIGURATION SUBJECT TO CURRENT TIA REQUIREMENTS.
6. PROVIDE FOR ONE 40-FOOT TALL SIGN ON LOT 2 AS SHOWN ON SUBMITTAL DOCUMENTS.
7. MONUMENT SIGN ON LOT 2 WILL ALLOW FOR OFF-PREMISES SIGNAGE FOR LOTS 1, 3 AND 4.
8. BUILDING ELEVATIONS FOR EACH LOT SHALL BE APPROVED AS PRESENTED.
9. FINAL IRRIGATION PLANS TO BE SUMBITTED FOR APPROVAL DURING PERMIT PROCESS
10. SITE LIGHTING SHALL MEET CITY OF COPPELL REQUIREMENTS. FINAL LIGHTING PLANS TO BE
SUBMITTED FOR APPROVAL DURING PERMIT PROCESS.
SITE DATA TABLE
LOT 1 (WAREHOUSE)
EXISTING ZONING PD-297R-LI -
PROPOSED ZONING -
PROPOSED USE WAREHOUSE -
TOTAL SITE AREA 9.01 AC
TOTAL SITE AREA 392,476 SF
BUILDING SQUARE FOOTAGE 130,698 SF
WAREHOUSE 50%-
OFFICE 16%-
UNCONCENTRATED 8%-
KITCHEN 7%-
SHOWROOM 19%-
GROSS FLOOR AREA 130,030 SF
BUILDING HEIGHT 40 FT
PARKING PROVIDED/REQUIRED 228 / 228 SPACES
WAREHOUSE (1000:1)65 SPACES
OFFICE (300:1)72 SPACES
UNCONCENTRATED (500:1)21 SPACES
KITCHEN (500:1)19 SPACES
SHOWROOM (500:1)51 SPACES
LOT BUILDING COVERAGE 33.30%-
FLOOR AREA RATIO 33.13%-
PERVIOUS COVER 77,313 SF
PERVIOUS COVERAGE 19.70%-
IMPERVIOUS COVER 315,163 SF
IMPERVIOUS COVERAGE 80.3%-
(214) 346-6200
RICHARDSON, TX 75081-2275
1201 NORTH BOWSER ROAD
3. REQUEST A VARIANCE FROM 60' SIDE YARD SETBACK TO BE REDUCED TO 34' AT PROPOSED
PORTE COCHERE AT SOUTHWEST BUILDING ENTRY.
PROPOSED VARIANCE
PD CONDITIONS 1 THRU 10 APPROVED IN PD-297-HC/LI, DATED 11/11/2021
VARIANCES 1-2 APPROVED IN PD-297-HC/LI, DATED 11/11/2021
LOTS 1, BLOCK A
WEST SANDY LAKE ROAD ADDITION II
SANDY LAKE - 121
TOWER OHE TRANSMISSIONFL IN 8" (S) = 510.06 FL OUT 8" (E) = 510.01 FL IN 8" (W) = 510.26 TOP OF RIM = 521.81 SANITARY SEWER MANHOLETOWER OHE TRANSMISSIONFL = 517.05 TOP OF RIM = 527.70 EXISTING STORM CURB INLETFL OUT (S) = 511.21 FL BOX = 511.48 TOP OF RIM = 515.58 EXISTING STORM CURB INLETFL = 511.00 LIP = 515.00 TOP OF RIM = 515.89STORM Y-INLET TSSIGNAL POLE EXISTING TRAFFIC TT
TTTT TT TT TTTTTTTTTTTTTTFHFHTT7'x2'24" RCP21" RCP21" RCP
FH FH
FH
FHFH
FH
T T21" RCP @ 0.75%21" RCP @ 0.75%24" RCP @ 0.75%@ 0.20%RCB48" RCP @ 0.20%@ 0.20%6'x2' RCP42" RCP @ 0.20%42" RCP @ 0.20%30" RCP @ 0.20%
FDC
24" RCP @ 1.55%TFHFH FHFDCFDCFHFHDD161336557211677109101051036871010105108484818182112
86
86
6
FHFHFHFH10
10
10
9
12
6
1313
11 11
7 10
5 8
7
11
11
9
6
7
4
3
LP LP
1.56 ACRES
LOT 4
FF = 521.00
9,600 SF
BUILDING D
ZONING: HC
FUTURE PHASESANDY LAKE ROADDD161336557211677109101051036871010105108FF = 520.75
130,698 SF
BUILDING C
9.01 ACRES
LOT 1, BLOCK A
6 10
12
inst. no. 201400150002
227.37' S 00°15'11" E 92.60' N 89°52'07" E 136.00' S 47°54'03" E
84.94' S 47°54'03" E
116.42' N 89°52'07" E 538.91' S 01°08'49" E
208.07' S 88°51'11" W117.97' N 47°53'35" WS 42°05'57" W41.00'
N 42°05'57" E
41.00'
18.00'
S 00°15'11" E
10008
10007
10006
10000
14.62' S 47°54'03" E
CB= S 0°00'00" E
CL= 30.98'
L= 31.69'
R= 43.00'
Δ= 42°1
LANDSCAPE ARCHITECT:
STATE HIGH
WAY 121
INST. NO. 201200116873)
STATE OF TEXAS
(VARIABLE WIDTH R.O.W.NN 41° 58' 59" E 446.86'550.00'1,254.86'S 01° 08' 49" EN 47° 49' 57" E 382.68'ENGINEER:
CEL: (214) 984-7321
TEL: (214) 346-6347
EMAIL: PBARTEL@HALFF.COM
CONTACT: PAUL D. BARTEL, P.E.
RICHARDSON, TX. 75081
1201 NORTH BOWSER ROAD
HALFF ASSOCIATES, INC.
ARCHITECT:
OWNER:
CEL: (512) 992-5349
TEL: (737) 309-4703
EMAIL: TFOX@HALFF.COM
CONTACT: TOBY FOX
AUSTIN, TX. 78729
13620 BRIARWICK DR BUIDLING C SUITE 100
HALFF ASSOCIATES, INC.
PRELIMINARY ENG. - LOT 1, BLOCK A
CEL: (214) 695-3616
TEL:
EMAIL: KEVIN.CLARK@WELBILT.COM
CONTACT: KEVIN CLARK
VERNON HILLS, IL 60061
101 CORPORATE WOODS PKWY.
WELBUILT, INC.
CEL: (469) 657-7080
TEL: (972) 419-3964
EMAIL: CVAUGHN@ENTOSDESIGN.COM
CONTACT: COLTON VAUGHN, RID
DALLAS, TX 75240
5400 LYNDON B. JOHNSON FWY, SUITE 125
ENTOS DESIGN
ZONING: LI
2 x 12'x14' DOCK DOORS
33 x 9'x10' DOCK DOORS
(ACTUAL NUMBER OF SPACES = 228)
19% SHOWROOM = 51 SPACES
7% KITCHEN = 19 SPACES
8% UNCONCENTRATED = 21 SPACES
16% OFFICE = 72 SPACES
50% WAREHOUSE = 65 SPACESELEMENT HOTEL BYMARRIOTT125 ROOMS5 STORY132 PARKING SPACESHOME 2 SUITES BYHILTON126 ROOMS5 STORY133 PARKING SPACES2.85 ACRESLOT 2, BLOCK A3.16 ACRESLOT 3, BLOCK AZONING: HC
TSPELEMENT HOTEL BYMARRIOTT125 ROOMS5 STORY132 PARKING SPACESHOME 2 SUITES BYHILTON126 ROOMS5 STORY133 PARKING SPACES2.85 ACRESLOT 2, BLOCK A3.16 ACRESLOT 3, BLOCK AZONING: HC
60' BUILDING SETBACK
D.R.D.C.T.
VOL. 2005005, PG. 70
10' BUILDING LINE
D.R.D.C.T.
VOL. 2005005, PG. 70
ONCOR 15' EASEMENT
D.R.D.C.T.
VOL. 2005005, PG. 70
EASEMENT
PRIVATE DRAINAGE
(O.P.R.D.C.T.)(INST. NO. 20140015002)(PARCEL II) (STATE OF TEXAS)(CALLED 6.925 ACRES)
ACCESS EASEMENT
VARIABLE WIDTH MUTUAL
EASEMENT
20' WATER
EASEMENT
24' FIRE LANE
EASEMENT
24' FIRE LANE
EASEMENT
26' FIRE LANE
EASEMENT
26' FIRE LANE
EASEMENT
40' FIRE LANE
EASEMENT
10' PRIVATE SEWER
15' WATER EASEMENT
D.R.D.C.T.
VOL. 86153, PG. 1282
T.P.&L. EASEMENT
AND SIDEWALK EASEMENT
VARIABLE WIDTH STREET
20' REAR SETBACK (HC)
30' SIDE SETBACK
10' REAR SETBACK (LI)
EASEMENT
20' WATER
EASEMENT
26' FIRE LANE
SETBACK
60' FRONT
EASEMENT
30' FIRE LANE
SETBACK
60' FRONT
EASEMENT
30' FIRE LANE
EASEMENT
MUTUAL ACCESS
VARIABLE WIDTH
EASEMENT
26' FIRE LANE
EASEMENT
26' FIRE LANE
EASEMENT
24' FIRE LANE
EASEMENT
ACCESS
25' MUTUAL
EASEMENT
ACCESS
34' MUTUAL
EASEMENT
ACCESS
25' MUTUAL
60' FRONT SETBACK
806040200
SCALE: 1"=40'
TRAP
PROPOSED GREASE
AND REPLACED
TO BE REMOVED
EX. TRANSFORMER
PROPOSED BACKUP GENERATOR
UNITS (TYP.)
PROPOSED DOAS