ADMIN APP 12-2-2024 Lot 1, Blk 3 Town Center Tank Enclosure21'-4"PAP Area of LeaseProposed BleachTank Enclosure(1 Tank)165'-3 1/2"Site slopes to drain at streetWill need a spill containment system that does not include an open drain that would allow storm water to infiltrate the sanitary sewersystem.ADMINISTRATIVELY APPROVED ON 12/02/2024 Matthew S. Steer, AICP, LEED® Green Associate ADMINISTRATIVELY APPROVED ON 12/02/2024 Matthew S. Steer, AICP, LEED® Green Associate TFEOSAR105189 TA EXRPBRIAN G. TORTIS T NNELAEOINSSGIF OEE The seal appearing on thisdocument was authorized byBrian G. Torti, P.E. #105189This document may not be changedin any fashion without permissionfrom Brian G. Torti, P.E.F-249041 REVISE CMU SCREEN WALL TO 10'11/08/24 2 3 4 5 6 7 8 PINCH-A-PENNY PINCH-A-PENNY 230 N. DENTON TAP RD. SUITE #102 COPPELL, TEXAS PLAN: TANK ADDITION 11/08/24 11/08/24GENERAL NOTES1. DESIGN CODESa)2015 I.B.Cb)BUILDING CODE REQUIREMENTS FOR REINFORCEDCONCRETE, ACI 318-08c)AISC SPECIFICATION FOR THE DESIGN, FABRICATIONAND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS,THIRTEENTH EDITION.d)ACI 117 "STANDARD SPECIFICATIONS FOR TOLERANCEFOR CONCRETE CONSTRUCTION AND MATERIALS"e)ACI 301 "SPECIFICATION FOR STRUCTURAL CONCRETEFOR BUILDINGS"f)ACI 318 "BUILDING CODE REQUIREMENTS FORREINFORCED CONCRETE"g)AISI "SPECIFICATIONS FOR THE DESIGN OFCOLD-FORMED STEEL STRUCTURAL MEMBERS"h)SJI "SPECIFICATIONS, LOAD TABLES AND WEIGHTTABLES FOR STEEL JOISTS AND JOIST GIRDERS"i)SDI "STEEL DECK MANUAL FOR FLOOR DECKS AND ROOFDECKS"j)ASW D1.1 "STRUCTURAL WELDING CODE - STEEL"k)ACI 530 "BUILDING CODE REQUIREMENTS FOR MASONRYSTRUCTURES"2. DESIGN LOADS:LIVE LOADS: ROOF: 20 PSFDEAD LOADS: WEIGHT OF MATERIALSWIND SPEED: 115 MPH (ULT)EXPOSURE CATEGORY: BBUILDING CATEGORY II3. EXISTING CONDITIONS: CONTRACTOR/BUILDER SHALL VISIT THEJOBSITE AS REQUIRED TO VERIFY EXISTING CONDITIONS.4. SEE ARCHITECTURAL DRAWINGS FOR FLOOR ELEVATIONS,SLOPES, AND LOCATIONS OF FLOOR DEPRESSIONS PRIOR TOSETTING FORMS. NOTIFY ENGINEER IMMEDIATELY SHOULD ANYDISCREPANCY BE FOUND BETWEEN ENGINEERING PLANS ANDARCHITECTURAL PLANS.5. FRAMING CONDITIONS NOT SPECIFICALLY SHOWN SHALL BEFRAMED SIMILAR TO DETAILS HEREIN.DRAWING INDEXS1 FOUNDATION PLANSCONCRETE NOTES1)ALL STRUCTURAL CONCRETE SHALL BE CLASSIFIED AS NORMAL WEIGHTCONCRETE WITH UNIT WEIGHT OF 145 LBS/FT^3. STRUCTURAL CONCRETEMEMBERS SHALL NOT BE LOADED UNITL THE SPECIFIED COMPRESSIVESTRENGTH HAS BEEN ACHIEVED.2)MINIMUM CONCRETE COMPRESSIVE STRENGTH AND SLUMP: MEMBER: STRENGTH: MIN. MAX.WALLS, SLABS & GRADE BEAMS 3000 PSI 4" 6"PIERS 3000 PSI 4" 6"3)CONCRETE MIX DESIGNS AND TEST RESULTS SHALL BE SUBMITTED FOREVALUATION AND APPROVAL. CONCRETE MIX DESIGNS SHALL COMPLY WITHACI CHAPTER 5.4)ALL CAST -IN-PLACE CONCRTE WORK SHALL BE IN ACCORDANCE WITH ACI 301,LATEST EDITION.5)ALL DETAILING, FABRICATION, AND INSTALLATION OF STEEL REINFORCINGSHALL BE IN ACCORDANCE WITH ACI 315 AND ACI 318, LATEST EDITIONS.6)CONCRET REINFORCING STEEL SHALL BE DEFORMED BARS.7)MINIMUM COVERAGE ON REINFORCING STEEL:CONCRETE CAST AGAINST EARTH:3" CLEAR TO STIRRUPCONCRETE CAST AGAINS FORMS:2" CLEAR TO STIRRUPGRADE BEAMS2" CLEAR TO STIRRUPSLAB ON VOIDS1 1/2" FOR TOPSLAB ON GRADEPLACE BARS IN MIDDLE8)PROVIDE 45-DEGREE CHAMFER AT ALL EXPOSED EDGES AND CORNERS.9)GENERAL CONTRACTOR SHALL COMPARE AND COORDINATE THIS PLAN WITHARCHITECTURAL SET. ANY DISCREPANCIES OR CHANGES SHALL BE BROUGHTTO THE ATTENTION OF THE ENGINEER.10)ALL OPENINGS FOR MECHNANICAL EQUIPMENT, TRENCHES, SLOPES TODRAINS ETC. SHALL BE VERIFIED BY THE GENERAL CONTRACTOR ANDINDICATED ON SHOP DRAWINGS. COORDINATE LOCATION AND SIZE OF ALLOPENINGS WITH APPLICABLE TRADES.11)PROVIDE (2) #4'S DIAGONALLY AT THE CORNERS OF ALL SLAB OPENINGS.12)SLAB REINFORCING SHALL HAVE STANDARD HOOKS AT SLAB ENDS.REINFORCING NOTES1)ALL REINFORCING SHALL CONFORM TO ASTM-A-615, GR. 60. STIRRUPS MAY BE 40KSI U.N.O.2)REINFORCING STEEL SHALL BE DESIGNED, DETAILED, FABRICATED AND PLACEDIN ACCORDANCE WITH THE LATEST ACI "MANUAL OF STANDARD PRACTICE FORDETAILING REINFORCED CONCRETE STRUCTURES, ACI-315 AND THE CRSI"RECOMMENDED PRACTICE FOR PLACING REINFORCING BARS, LATEST EDITION.3)SPLICES IN REINFORCING SHALL OCCUR AT POINTS OF MINIMUM STRESS ANDSHALL BE LAPPED MIN. OF 40 BAR DIAMETERS.4)PROVIDE CORNER BARS AT ALL CORNERS AND INTERSECTIONS. BARS SHOULDBE THE SAME SIZE AND SPACING OF LARGER REINFORCING.5)SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL PRIOR TO FABRICATIONOF MATERIALS.REVISIONS SHEET NUMBER:DATE:SCALE:DATE Precision Structural Engineering, LLC P.O. Box #2421 Coppell, Texas 75019 Office: 214-223-0286S0SEE PLANADMINISTRATIVELY APPROVED ON 12/02/2024 Matthew S. Steer, AICP, LEED® Green Associate TFEOSAR105189 TA EXRPBRIAN G. TORTIS T NNELAEOINSSGIF OEE The seal appearing on thisdocument was authorized byBrian G. Torti, P.E. #105189This document may not be changedin any fashion without permissionfrom Brian G. Torti, P.E.F-249041 REVISE CMU SCREEN WALL TO 10'11/08/24 2 3 4 5 6 7 8 PINCH-A-PENNY PINCH-A-PENNY 230 N. DENTON TAP RD. SUITE #102 COPPELL, TEXAS PLAN: TANK ADDITION 11/08/24TANK PAD PLAN 11/08/242'-8"5'-4"6'-7"2" CLEAR1'-0"1TANK PAD SECTION10'-0" MAX 2'-8"5'-4"DRY STACK PATTERN FOR CONCRETEBLOCK BASE STRUCTURE AT EACH TANK25'-4"5'-4"TOP VIEW2AREVISIONS SHEET NUMBER:DATE:SCALE:DATE Precision Structural Engineering, LLC P.O. Box #2421 Coppell, Texas 75019 Office: 214-223-0286S1SEE PLANADMINISTRATIVELY APPROVED ON 12/02/2024 Matthew S. Steer, AICP, LEED® Green Associate