Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Admin APP Property Lines Revised (1-10-2025)
D R I V E TH R U1560 S BELT LINE ROADRETAIL BUILDING BY OTHERS(10,990 SF)FFE=527.20OHE ZOHE ZOHE ZOHE ZOHE ZOHE ZOHE ZOHE ZOHE ZOHE ZOHE ZOHE ZOHES BELT LINE ROAD120' R.O.W.VOL. 4499, PAGE 159, D.R.D.C.T.FIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANE FIRELANEFIRELANERELA NE FIRELA NE FIRELANE FIRELANEFIRELANE FIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFI RE LA NE FIRELA NE FIRELA NE FIRELA NE FIRELA NE FIRELA NE FIRELA NE FIRELA NE FINOPARKINGNOPARKING14.0'24.0'R3.0' TYP.R5.0'20.3'R5.0'18.0' TYP.9.0' TYP.R3.0' TYP.24.0'R15.0'R10.0'R6.0'R10.0'8.3'18.0' TYP.9.0' TYP.9.0'R10.0' R20.0'R3.0'R2.0'8.0'R2.0'R3.0'R2 0 .0 'R10.0'18.0'R3 5 . 5 ' R 3 2 . 5 '9.0' TYP.14.0'4.0'12.0'12.5'3.0'5.0' TYP.LOT 4, BLOCK AVICTORY AT COPPELL ADDITION2.247 ACRES(97,865 SF)1560 S BELT LINE ROADRETAIL BUILDING BY OTHERS(10,990 SF)FFE=527.20LOT 9, BLOCK AVICTORY AT COPPELL ADDITION1.060 ACRES(46,160 SF)R 5 . 0 '42.2'79.4'R40.0'R40.0'18.0' TYP.18.0' TYP.9.0' TYP.38.5'135.2'1 6 . 3 '13.3'R5.0'19.0'R 4 8 . 0 'R3.0 '14.0'12.0'12.5'R15.0'8.0'14.0'5.0' TYP.81.9'LOT 5, BLOCK AVICTORY AT COPPELL ADDITION0.992 ACRES(45,223 SF)5.0'LOT 4, BLOCK AVICTORY AT COPPELL ADDITION2.247 ACRES(97,865 SF)NOTES1.ALL DIMENSIONS ARE SHOWN PERPENDICULAR AND TO THE FRONT OF THE CURB UNLESSOTHERWISE NOTED.2.ALL CURB IS PERMANENT UNLESS NOTED OTHERWISE.3.SEE ARCHITECT PLANS FOR EXACT BUILDING DIMENSIONS. CONTRACTOR TO NOTIFY ENGINEEROF ANY DISCREPANCIES.4.CONTRACTOR TO USE CARE NOT TO DISTURB EXISTING LANDSCAPING OUTSIDE DISTURBEDAREA. IF DISTURBED CONTRACTOR TO RESTORE TO ORIGINAL CONDITIONS OR BETTER.5.CONTRACTOR TO VERIFY THE LOCATION OF EXISTING UTILITIES PRIOR TO CONSTRUCTION.6.DELIVERIES TAKE PLACE OUTSIDE OF STORE HOURS. STORE HOURS ARE FROM 6 A.M. TO 9 P.M.7.FINAL PLAT SHALL BE RECORDED AND ALL PREVIOUSLY APPROVED CONDITIONS OFPD-301R3-HC, CONCEPTUAL PLAN ORDINANCE SHALL BE ADDRESSED PRIOR TO A BUILDINGPERMIT BEING ISSUED FOR THIS SITE.OWNERQUIDDITY, INC.4500 MERCANTILE PLAZA DRIVESUITE 210FORT WORTH, TEXAS 76137TEL (972) 265-7190CONTACT: AARON HAWKINS, PEENGINEERVICTORY GROUP, LLC2911 TURTLE CREEK BOULEVARD,SUITE 700DALLAS, TEXAS 75219TEL (214) 901-1514CONTACT: BOBBY MENDOZALEGENDPROPERTY LINEPARKING COUNT5BUILDING CORNERSPROP. SIDEWALKPROP. MENU BOARDEXIST. OVERHEAD POWERPROP. BARRIER FREE RAMPADA ROUTEEXIST. TREEEXIST. SIDEWALKC-5SITE PLAN 1570 S BELT LINE LOT 5, BLOCK A VICTORY AT COPPELL ADDITION COPPELL, TX 75019 EXISTING ZONING:PD - 301R3 - HC (HIGHWAY COMMERCIAL)PROPOSED ZONING: PD - 301R4 - HC (HIGHWAY COMMERCIALCURRENT USE: EMPTY PAD (DESIGNATED QSR)PROPOSED USE: DRIVE-THRU ONLY RESTAURANT (QSR)GENERALGROSS SITE AREA:0.992 ACRES (43,223 SQUARE FEET)SITE FRONTAGE:169 FEETSITE WIDTH:169 FEETSITE DEPTH:305 FEETIMPERVIOUS COVER:29,801 SQUARE FEET (0.684 ACRES)PERVIOUS COVER: 13,422 SQUARE FEET (0.308 ACRES)OVERALL SITEBUILDING AREA:1000 SQUARE FEETBUILDING HEIGHT:20 FEET (1 STORY)BUILDING COVERAGE:2.20%FLOOR:AREA RATIO0.02 : 1BUILDING DATAPARKING SPACE RATIO: 1/100 SF 1/71 SFPARKING SPACE:10 SPACES14 SPACESADA PARKING SPACES:1 SPACE2 SPACESQUEUING FROM POINT OF ORDER:5 SPACES5 SPACES - SW LANE6 SPACES - NE LANEPARKING CALCULATIONSREQUIREDPROPOSEDREVISIONSOFNo.Date App.SHEET NO.K:\17007\17007-0146-02 salad and go - i-635 and belt line - coppell\2 design phase\CAD\Plans\Site\17007-0146 SITE PLAN.dwg HTF: December 23, 2024© 2024 Quiddity JOB NO.: SCALE:DESIGNED BY.:HTF CHECKED BY:ACH ABCDEF1234 DATE: DRAWN BY:AM AS SHOWN DECEMBER 2024 17007-0146-02 BENCHMARKALL ELEVATIONS AND BEARINGS SHOWN HEREON ARE BASED ON GPS OBSERVATIONS UTILIZINGTHE ALLTERA RTK NETWORK. NAVD (88) DATUM, (GEOID 12A)TBM ABEING A TBM XCS BOX IN THE CONCRETE PAVEMENT LOCATED TO THE EAST OF THE LOT,APPROXIMATELY 378 FEET EAST AND 216 FEET NORTH OF THE NORTHEAST CORNER OF THESUBJECT TRACT.ELEVATION 530.06 FEET, NAVD 88 (2011 ADJUSTMENT).TBM BBEING A TBM XCS BOX ON THE CONCRETE PAVEMENT IN HACKBERRY ROAD LOCATED TO THESOUTH OF THE LOT, APPROXIMATELY 466 FEET SOUTH OF THE SOUTHERN CORNER OF THE SUBJECTTRACT.ELEVATION 536.84 FEET, NAVD 88 (2011 ADJUSTMENT).100-YEAR FLOOD PLAINACCORDING TO MAP NO. 48113C0135K OF THE FEDERAL EMERGENCY MANAGEMENT AGENCY'SFLOOD INSURANCE RATE MAPS FOR DALLAS COUNTY DATED JULY 7, 2014, THE SUBJECT TRACT ISSITUATED WITHIN: UNSHADED ZONE “X”; DEFINED AS AREA OF MINIMAL FLOOD HAZARD.TEXAS811 NOTIFICATION SYSTEMCALL BEFORE YOU DIG!!!www.texas811.orgTexas811 or 1-800-545-6005CONTRACTOR TO VERIFY ELEVATION AND LOCATIONOF ALL EXISTING UTILITIES PRIOR TOCOMMENCEMENT OF ANY NEW CONSTRUCTIONC-18Texas Board of Professional Engineers and Land Surveyors Reg. No. F-232904500 Mercantile Plaza Drive, Suite 210 Fort Worth, Texas 76137 682.268.2200 SALAD AND GO - COPPELL - I-635 AND BELT LINE 1570 S BELT LINE, COPPELL, TX 75019 PROP. 10'CURB INLET2314R2.0'PROP. 10'CURB INLETR10.0'4PROP. DUMPSTER ENCLOSURE.SEE ARCHITECT PLANS FOR DETAILS.DUMPSTER GATES TO REMAINCLOSED WHILE NOT IN SERVICEPROPOSED SALAD AND GODRIVE-THRU RESTAURANTFFE: 531.00SITE DATA BASED ON SALAD AND GO PROPOSED DEVELOPMENTVICTORY AT COPPELL ADDITION LOT 5 BLOCK APROP. MENU BOARDS ANDSPEAKER BASE. SEEARCHITECT PLANS FOR DETAILSPROP. SITE LIGHTING.SEE PHOTOMETRIC PLAN FOR DETAILS.12/23/2024ADMINISTRATIVELY APPROVED ON 01/10/2025 Matthew S. Steer, AICP, LEED® Green AssociateProperty Lines adjusted to reflect Approved Concept Plan NO PARKINGNOPARKINGONLY S BELT LINE ROAD120' R.O.W.VOL. 4499, PAGE 159, D.R.D.C.T.PAD SITE 51.04 acDRIVETHRUQSR2,200sf1 CE 845 AJ BERMUDA SOLID SOD, TYP. BERMUDA SOLID SOD, TYP. OLD TOWN FIBERGLASS PLANTER (2): 30" W, 60" L, 18" HT; FLAME #28, M, TYP. OLD TOWN FIBERGLASS PLANTER (3): 30" W, 120" L, 18" HT, FLAME #28, M, TYP.REF. CIVIL FOR CONTINUATION OF DRAINAGE VIA PIPE THROUGH FACE OF CURB, TYP. 1-3" RIVER ROCK, TYP. 1-3" RIVER ROCK, TYP. 26 WM 780 MG 4 RO 1 CE 65 GL STEEL EDGE, TYP. 3 RB 1380 AJ 25 GL 1 CE 25 GL 19 MS 1 CE 1 CE 1 CE 6 MS 3 RY 1 CE 6 RY 1 CE 25 GL 13 DY 7 MS 1 CE 5 DCM 10 RM 9 GM 3 CE 45 GL STEEL EDGE, TYP. STEEL EDGE, TYP. 1-3" RIVER ROCK, TYP. BERMUDA SOLID SOD, TYP. 2 CE REVISIONSOFNo.DateApp.SHEET NO.© 2024 QuiddityJOB NO.:SCALE:DESIGNED BY.:HTFCHECKED BY:ACHA B C D E F 1234DATE:DRAWN BY:AMAS SHOWNJANUARY 202517007-0146-02Texas Board of Professional Engineers and Land Surveyors Reg. No. F-232904500 Mercantile Plaza Drive, Suite 210 Fort Worth, Texas 76137 682.268.2200 SALAD AND GO - COPPELL - I-635 AND BELT LINESTA TE O F T E XASTCETHI R CA EPACSDNALDEE GEISRRT572 4AMANARICHDW. A RDSONa W R AWR Designs, LLC P.O. Box 1746 Aledo, Texas 76008 amanda@awr-designs.com c. 512.517.5589 2-19-24 1570 S BELT LINE, COPPELL, TX 750191570 S BELT LINELOT 5, BLOCK AVICTORY AT COPPELL ADDITIONCOPPELL, TX 75019L1.01TREE SURVEY/LANDSCAPE PLANGENERAL LAWN NOTES 1.CONTRACTOR SHALL COORDINATE OPERATIONS AND AVAILABILITY OF EXISTING TOPSOIL WITH ON-SITE CONSTRUCTION MANAGER 2.LAWN AREAS SHALL BE LEFT 1" BELOW FINAL FINISHED GRADE PRIOR TO TOPSOIL INSTALLATION. 3.CONTRACTOR TO FIND GRADE AREAS TO ACHIEVE FINAL CONTOURS AS SHOWN ON CIVIL DRAWINGS. POSITIVE DRAINAGE SHALL BE PROVIDED AWAY FROM ALL BUILDINGS. ROUNDING AT TOP AND BOTTOM OF SLOPES SHALL BE PROVIDED AND IN OTHER BREAKS IN GRADE. CORRECT AREAS WHERE STANDING WATER MAY OCCUR. 4.ALL LAWN AREAS SHALL BE FINE GRADED, IRRIGATION TRENCHES COMPLETELY SETTLED AND FINISH GRADE APPROVED BY THE OWNER'S CONSTRUCTION MANAGER OR LANDSCAPE ARCHITECT PRIOR TO LAWN INSTALLATION. 5.CONTRACTOR SHALL REMOVE ALL ROCKS 3/4" IN DIAMETER AND LARGER. REMOVE ALL DIRT CLODS, STICKS, CONCRETE SPOILS, TRASH ETC PRIOR TO PLACING TOPSOIL AND GRASS INSTALLATION. 6.CONTRACTOR SHALL MAINTAIN ALL LAWN AREAS UNTIL FINAL ACCEPTANCE. 7.CONTRACTOR SHALL GUARANTEE ESTABLISHMENT OF ACCEPTABLE TURF AREA AND SHALL PROVIDE REPLACEMENT IF NECESSARY. SOLID SOD: 1.SOLID SOD SHALL BE PLACED ALONG ALL IMPERVIOUS EDGES, AT A MINIMUM. THIS SHALL INCLUDE CURBS, WALKS, INLETS, MANHOLES AND PLANTING BED AREAS. SOD SHALL COVER OTHER AREAS COMPLETELY AS INDICATED BY PLAN. 2.SOD SHALL BE STRONGLY ROOTED DROUGHT RESISTANT SOD, NOT LESS THAN 2 YEARS OLD, FREE OF WEEDS AND UNDESIRABLE NATIVE GRASS AND MACHINE CUT TO PAD THICKNESS OF 3/4" (+1/4"), EXCLUDING TOP GROWTH AND THATCH. 3.LAY SOD BY HAND TO COVER INDICATED AREAS COMPLETELY, ENSURING EDGES ARE TOUCHING WITH TIGHTLY FITTING JOINTS, NO OVERLAPS WITH STAGGERED STRIPS TO OFFSET JOINTS. 4.TOP DRESS JOINTS IN SOD BY HAND WITH TOPSOIL TO FILL VOIDS IF NECESSARY 5.SOD SHALL BE ROLLED TO CREATE A SMOOTH EVEN SURFACE. SOD SHOULD BE WATERED THOROUGHLY DURING INSTALLATION PROCESS. 6.SHOULD INSTALLATION OCCUR BETWEEN OCTOBER 1ST AND MARCH 1ST, OVERSEED BERMUDAGRASS SOD WITH WINTER RYEGRASS AT A RATE OF 4 POUNDS PER 1000 S.F. HYDROMULCH: 1.SCARIFY AND LOOSEN ALL AREAS TO BE HYDROMULCHED TO A MINIMUM DEPTH OF 4" PRIOR TO TOPSOIL AND HYDROMULCH INSTALLATION. 2.BERMUDA GRASS SEED SHALL BE EXTRA HULLED, TREATED LAWN TYPE. SEED SHALL BE DELIVERED TO THE SITE IN ITS ORIGINAL UNOPENED CONTAINER AND SHALL MEET ALL STATE/LOCAL LAW REQUIREMENTS. 3.FIBER SHALL BE 100% WOOD CELLULOSE FIVER, DELIVERED TO THE SITE IN ITS ORIGINAL UNOPENED CONTAINER AS MANUFACTURED BY "CONWEB' OR EQUAL. 4.FIBER TACK SHALL BE DELIVERED TO THE SITE IN ITS UNOPENED CONTAINER AND SHALL BE 'TERRO-TACK ONE', AS MANUFACTURED BY GROWERS, INC OR APPROVED EQUAL. 5.HYDROMULCH WITH BERMUDA GRASS SEET AT A RATE OF 2 POUNDS PER 1000 S.F. 6.USE A BATTER BOARD AGAINST ALL BED AREAS TO PREVENT OVER SPRAY. 7.IF INADEQUATE MOISTURE IS PRESENT IN SOIL, APPLY WATER AS NECESSARY FOR OPTIMUM MOISTURE FOR SEED APPLICATION. 8.IF INSTALLATION OCCURS BETWEEN SEPTEMBER 1ST AND MAY 1ST, ALL HYDORMULCH AREAS SHALL BE OVER-SEEDED WITH WINTER RYE GRASS AT A RATE OF FOUR POUNDS PER ONE THOUSAND SQUARE FEET. CONTRACTOR SHALL BE REQUIRED TO RE-HYDROMULCH WITH BERMUDA GRASS THE FOLLOWING GROWING SEASON AS PART OF THIS CONTRACT. 9.AFTER APPLICATION, NO EQUIPMENT SHALL OPERATE OVER APPLIED AREAS. WATER SEEDED AREAS IMMEDIATELY AFTER INSTALLATION TO SATURATION. 10.ALL LAWN AREAS TO BE HYDROMULCHED SHALL ACHIEVE 100% COVERAGE PRIOR TO FINAL ACCEPTANCE. LANDSCAPE NOTES 1.CONTRACTOR TO VERIFY AND LOCATE ALL PROPOSED AND EXISTING ELEMENTS. NOTIFY LANDSCAPE ARCHITECT OR DESIGNATED REPRESENTATIVE FOR ANY LAYOUT DISCREPANCIES OR ANY CONDITION THAT WOULD PROHIBIT THE INSTALLATION AS SHOWN. SURVEY DATA OF EXISTING CONDITIONS WAS SUPPLIED BY OTHERS 2.CONTRACTOR SHALL CALL 811 TO VERIFY AND LOCATE ANY AND ALL UTILITIES ON SITE PRIOR TO COMMENCING WORK. LANDSCAPE ARCHITECT SHOULD BE NOTIFIED OF ANY CONFLICTS. CONTRACTOR TO EXERCISE EXTREME CAUTION WHEN WORKING NEAR UNDERGROUND UTILITIES. 3.A MINIMUM OF 2% SLOPE SHALL BE PROVIDED AWAY FROM ALL STRUCTURES. 4.CONTRACTOR SHALL FINE GRADE AREAS TO ACHIEVE FINAL CONTOURS AS INDICATED. LEAVE AREAS TO RECEIVE TOPSOIL 3" BELOW FINAL FINISHED GRADE IN PLANTING AREAS AND 1" BELOW FINAL FINISHED GRADE IN LAWN AREAS. 5.LANDSCAPE ISLANDS SHALL BE CROWNED, AND UNIFORM THROUGHOUT THE SITE. 6.PLANTING AREAS AND SOD TO BE SEPARATED BY STEEL EDGING. NO STEEL EDGING SHALL BE INSTALLED ADJACENT TO BUILDINGS, WALKS OR CURBS. EDGING NOT TO BE MORE THAN 1/2" ABOVE FINISHED GRADE. 7.EDGING SHALL BE CUT AT 45 DEGREE ANGLE WHERE IT INTERSECTS WALKS AND/OR CURBS. 8.MULCH SHALL BE INSTALLED AT 1/2" BELOW THE TOPS OF SIDEWALKS AND CURBING. 9.QUANTITIES ON THESE PLANS ARE FOR REFERENCE ONLY. THE SPACING OF PLANTS SHOULD BE AS INDICATED ON PLANS OR OTHERWISE NOTED. ALL TREES AND SHRUBS SHALL BE PLANTED PER DETAILS. 10.CONTAINER GROWN PLANT MATERIAL IS PREFERRED HOWEVER BALL AND BURLAP PLANT MATERIAL CAN BE SUBSTITUTED IF NEED BE AND IS APPROPRIATE TO THE SIZE AND QUALITY INDICATED ON THE PLANT MATERIAL LIST. 11.TREES SHALL BE PLANTED AT A MINIMUM OF 5' FROM ANY UTILITY LINE, SIDEWALK OR CURB. TREES SHALL ALSO BE 10' CLEAR FROM FIRE HYDRANTS. 12.4" OF SHREDDED HARDWOOD MULCH (2" SETTLED THICKNESS) SHALL BE PLACED OVER WEED BARRIER FABRIC. MULCH SHALL BE SHREDDED HARDWOOD MULCH OR APPROVED EQUAL, PINE STRAW MULCH IS PROHIBITED. 13.WEED BARRIER FABRIC SHALL BE USED IN PLANT BEDS AND AROUND ALL TREES AND SHALL BE MIRAFI 1405 WEED BARRIER OR APPROVED EQUAL. 14.CONTRACTOR TO PROVIDE UNIT PRICING OF LANDSCAPE MATERIALS AND BE RESPONSIBLE FOR OBTAINING ALL LANDSCAPE AND IRRIGATION PERMITS. IRRIGATION: 1.ALL REQUIRED LANDSCAPE AREAS SHALL HAVE AN AUTOMATIC IRRIGATION SYSTEM WITH A FREEZE/RAIN SENSOR. SYSTEM SHALL ALSO HAVE AN ET WEATHER BASED CONTROLLER AND BE DESIGNED AND INSTALLED BY A LICENSED IRRIGATOR. MAINTENANCE REQUIREMENTS: 1.VEGETATION SHOULD BE INSPECTED REGULARLY TO ENSURE THAT PLANT MATERIAL IS ESTABLISHING PROPERLY AND REMAINS IN A HEALTHY GROWING CONDITION APPROPRIATE FOR THE SEASON. IF DAMAGED OR REMOVED, PLANTS MUST BE REPLACED BY A SIMILAR VARIETY AND SIZE. 2.MOWING, TRIMMING, EDGING AND SUPERVISION OF WATER APPLICATIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR UNTIL THE OWNER OR OWNER'S REPRESENTATIVE ACCEPTS AND ASSUMES REGULAR MAINTENANCE. 3.ALL LANDSCAPE AREAS SHOULD BE CLEANED AND KEPT FREE OF TRASH, DEBRIS, WEEDS AND OTHER MATERIAL. MISCELLANEOUS MATERIALS: 1.STEEL EDGING SHALL BE 3/16" X 4 X 16' DARK GREEN DURAEDGE STEEL LANDSCAPE EDGING UNLESS NOTED OTHERWISE ON PLANS/DETAILS. 2.RIVER ROCK SHALL BE ARIZONA RIVER ROCK, 2" - 4" DIAMETER. RIVER ROCK SHALL BE COMPACTED TO A MINIMUM OF 3" DEPTH OVER FILTER FABRIC. FOR PLANTERS CONTACT: BRIAN VAVRINA BV ASSOCIATES 800.496.0487 brian@bv-associates.com TWO PLANTER TYPES: (2)30" W X 60" L X 18" HT (3)30" W X 120" L X 18" HT COLOR: FLAME #28, TEXTURE M CITY TREE NOTE: THERE ARE NO EXISTING TREES ON SITE. ADMINISTRATIVELY APPROVED ON 01/10/2025 Matthew S. Steer, AICP, LEED® Green Associate Property Lines adjusted to reflect Approved Concept Plan REVISIONSOFNo.DateApp.SHEET NO.© 2024 QuiddityJOB NO.:SCALE:DESIGNED BY.:HTFCHECKED BY:ACHA B C D E F 1234DATE:DRAWN BY:AMAS SHOWNJANUARY 202517007-0146-02Texas Board of Professional Engineers and Land Surveyors Reg. No. F-232904500 Mercantile Plaza Drive, Suite 210 Fort Worth, Texas 76137 682.268.2200 SALAD AND GO - COPPELL - I-635 AND BELT LINESTA TE O F T E XASTCETHI R CA EPACSDNALDEE GEISRRT572 4AMANARICHDW. A RDSONa W R AWR Designs, LLC P.O. Box 1746 Aledo, Texas 76008 amanda@awr-designs.com c. 512.517.5589 2-19-24 1570 S BELT LINE, COPPELL, TX 750191570 S BELT LINELOT 5, BLOCK AVICTORY AT COPPELL ADDITIONCOPPELL, TX 75019L1.02LANDSCAPE SPECIFICATIONS AND DETAILSSHRUB PLANTING SHRUBS OR GROUNDCOVER AS SPECIFIED ON PLAN PLANTING SOIL MIX. TILL IN WITH PARTS EXISTING SOIL, EXCLUDING LARGE CLODS AND ROCKS. ROOT BALL, DO NOT DISTURB UNDISTURBED SUBGRADE / NATIVE SOIL WEED BARRIER FABRIC LAYER OF MULCH, SETTLED THICKNESS SHOULD BE 2" MIN.CURB OR SIDEWALK, NO STEEL EDGING ALONG WALK, TYP. TOP OF MULCH SHOULD BE, AT MINIMUM, 1/2" BELOW WALK OR CURBING REF. LANDSCAPE PLAN FOR SPACING 2 N.T.S. 1/2" MAXIMUM O.C. SPACINGO.C. SPACING BACK OF CURB MULCH 24" MIN. SETBACK FOR SHRUBS & GROUNDCOVERS ALONG BACK OF CURB TO ALLOW FOR CAR OVERHANG SHRUB SPACING AND PLANTING AT B.O.C.3 N.T.S. 4' MIN. 2.5' MIN. SPECIFIED BED BORDER 2' MIN. BACK OF CURB MULCH PER SPECIFICATIONS LAWN SHRUBS AND GROUNDCOVER REFER TO PLANS FOR PLANT TYPES PREPARED SOIL MIX PER SPECIFICATIONS 3/16" X 4" X 16" STEEL EDGING WITH STAKES NOTE: NO STEEL EDGING TO BE INSTALLED ALONG SIDEWALKS 1/2" MAXIMUM STEEL EDGING DETAIL4 N.T.S. DECOMPOSED GRANITE / RIVER ROCK5 N.T.S. DECOMPOSED GRANITE AND/OR RIVER ROCK TO BE COMPACTED TO A 3" DEPTH PLANTING AREA, REFERENCE LANDSCAPE PLAN DECOMPOSED GRANITE / RIVER ROCK ENSURE PROPER DRAINAGE STEEL EDGING FILTER FABRIC, WRAP UP AT EDGING, TYP. COMPACTED SUBGRADE SECTION 32 9300 - LANDSCAPE PART 1 - GENERAL 1.1 QUALIFICATIONS OF THE LANDSCAPE CONTRACTOR. A.ALL LANDSCAPE WORK SHOWN ON THESE PLANS SHALL BE PERFORMED BY A SINGLE FIRM SPECIALIZING IN LANDSCAPE PLANTING 1.2 REFERENCE DOCUMENTS A.REFER TO LANDSCAPE PLANS, NOTES, SCHEDULES AND DETAILS FOR ADDITIONAL REQUIREMENTS 1.3 SCOPE OF WORK / DESCRIPTION OF WORK A.WORK COVERED BY THESE SECTIONS INCLUDES: FURNISH ALL SUPERVISIONS, LABOR, MATERIALS, SERVICES, EQUIPMENT AND APPLIANCES REQUIRED TO COMPLETE THE WORK COVERED IN CONJUNCTION WITH THE LANDSCAPING COVERED IN LANDSCAPE PLANS AND SPECIFICATIONS INCLUDING: 1. PLANTING (TREES, SHRUBS, GRASSES) 1.BED PREP AND FERTILIZATION 3. NOTIFICATION OF SOURCES 4. WATER AND MAINTENANCE UNTIL ACCEPTANCE 5. GUARANTEE B.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES AND REGULATIONS REQUIRED BY AUTHORITIES HAVING JURISDICTION OVER SUCH WORK, INCLUDING ALL INSPECTIONS AND PERMITS REQUIRED BY FEDERAL, STATE AND LOCAL AUTHORITIES IN SUPPLY, TRANSPORTATION AND INSTALLATION OF MATERIALS. C.THE LANDSCAPE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITY LINES (WATER, SEWER, ELECTRICAL, TELEPHONE, GAS, CABLE, TELEVISION, ETC.) PRIOR TO THE START OF ANY WORK 1.4 REFERENCES A.AMERICAN STANDARD FOR NURSERY STOCK PUBLISHED BY AMERICAN ASSOCIATION OF NURSERYMEN; 27 OCTOBER 1980, EDITION; BY AMERICAN NATIONAL STANDARDS INSTUTUTE (Z60.1) - PLANT MATERIAL B.AMERICAN JOINT COMMITTEE ON HORTICULTURE NOMENCLATURE; 1942 EDITION OF STANDARDIZED PLANT NAMES. C.TEXAS ASSOCIATION OF NURSERYMEN, GRADES AND STANDARDS 1.5 SUBMITTALS A.PROVIDE REPRESENTATIVE QUANTITIES OF EACH SOIL, MULCH, BED MIX, GRAVEL AND STONE BEFORE INSTALLATION. SAMPLES TO BE APPROVED BY OWNER'S REPRESENTATIVE BEFORE USE. B.SOIL AMENDMENTS AND FERTILIZERS SHOULD BE RESEARCHED AND BASED ON THE SOILS IN THE AREA. C.BEFORE INSTALLATION, SUBMIT DOCUMENTATION THAT PLANT MATERIALS ARE AVAILABLE AND HAVE BEEN RESERVED. FOR ANY PLANT MATERIAL NOT AVAILABLE, SUBMIT REQUEST FOR SUBSTITUTION. 1.6 JOB CONDITIONS, DELIVERY, STORAGE AND HANDLING A.GENERAL CONTRACTOR TO COMPLETE WORK BEFORE LANDSCAPE CONTRACTOR TO COMMENCE. B.ALL PLANTING BED AREAS SHALL BE LEFT THREE INCHES BELOW FINAL GRADE OF SIDEWALKS, DRIVES AND CURBS. ALL AREAS TO RECEIVE SOLID SOD SHALL BE LEFT ONE INCH BELOW THE FINAL GRADE OF WALKS, DRIVES AND CURBS. CONSTRUCTION DEBRIS SHALL BE REMOVED PRIOR TO LANDSCAPE CONTRACTOR BEGINNING WORK C.STORAGE OF MATERIALS AND EQUIPMENT AT THE JOB SITE WILL BE AT THE RISK OF THE LANDSCAPE CONTRACTOR. THE OWNER CANNOT BE HELD RESPONSIBLE FOR THEFT OR DAMAGE. 1.7 SEQUENCING A.INSTALL TREES, SHRUBS, AND LINER STOCK PLANT MATERIALS PRIOR TO INSTALLATION OF LAWN/SOLID SOD. B.WHERE EXISTING TURF AREAS ARE BEING CONVERTED TO PLANTING BEDS, THE TURF SHALL BE CHEMICALLY ERADICATED TO MINIMIZE RE-GROWTH IN THE FUTURE. AREAS SHALL BE PROPERLY PREPARED WITH AMENDED ORGANIC MATTER. 1.8 MAINTENANCE AND GUARANTEE MAINTENANCE: A.THE LANDSCAPE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE MAINTENANCE OF ALL WORK FROM THE TIME OF PLANTING UNTIL FINAL ACCEPTANCE BY OWNER. B.NO TREES, GRASS, GROUNDCOVER OR GRASS WILL BE ACCEPTED UNLESS THEY SHOW HEALTHY GROWTH AND SATISFACTORY FOLIAGE CONDITIONS. C.MAINTENANCE SHALL INCLUDE WATERING OF TREES AND PLANTS, CULTIVATION, WEED SPRAYING, EDGING, PRUNING OF TREES, MOWING OF GRASS, CLEANING UP AND ALL OTHER WORK NECESSARY FOR MAINTENANCE. D.A WRITTEN NOTICE REQUESTING FINAL INSPECTION AND ACCEPTANCE SHOULD BE SUBMITTED TO THE OWNER AT LEAST 7 DAYS PRIOR TO COMPLETION. AN ON SITE INSPECTION BY THE OWNER'S AUTHORIZED REPRESENTATIVE WILL BE COMPLETED PRIOR TO WRITTEN ACCEPTANCE. E.NOTIFY OWNER OR OWNER'S REPRESENTATIVE SEVEN DAYS PRIOR TO THE EXPIRATION OF THE WARRANTY PERIOD. F.REMOVE DEAD, UNHEALTHY AND UNSIGHTLY PLANTS DURING WARRANTY PERIOD G.REMOVE GUYING AND STAKING MATERIALS AFTER ONE YEAR H.ALL LANDSCAPE MUST BE MAINTAINED AND GRASS MOWED/EDGED ON A WEEKLY SCHEDULE UNTIL ACCEPTANCE BY OWNER. REMOVE CLIPPINGS AND DEBRIS FROM SITE PROMPTLY. I.REMOVE TRASH, DEBRIS, AND LITTER. WATER, PRUNE, RESTAKE TREES, FERTILIZE, WEED AND APPLY HERBICIDES AND FUNGICIDES AS REQUIRED. J.COORDINATE THE OPERATION OF IRRIGATION SYSTEM TO ENSURE THAT PLANTS ARE ADEQUATELY WATERED. HAND WATER AREAS NOT RECEIVING ADEQUATE WATER FROM AN IRRIGATION SYSTEM. K.THE LANDSCAPE CONTRACTOR SHALL MAINTAIN THE IRRIGATION SYSTEM IN ACCORDANCE TO THE MAINTENANCE SERVICE TO ENSURE THE SYSTEM IS IN PROPER WORKING ORDER WITH SCHEDULING ADJUSTMENTS BY SEASON TO MAXIMIZE WATER CONSERVATION. L.REAPPLY MULCH TO BARE AND THIN AREAS. M.SHOULD SEEDED AND/OR SODDED AREAS NOT BE COVERED BY AN AUTOMATIC IRRIGATION SYSTEM, THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR WATERING THESE AREAS AND OBTAINING A FULL, HEALTHY STAND OF GRASS AT NO ADDITIONAL COST TO THE OWNER. N.TO ACHIEVE FINAL ACCEPTANCE AT THE END OF THE MAINTENANCE PERIOD, ALL OF THE FOLLOWING CONDITIONS MUST OCCUR: a.THE LANDSCAPE SHALL SHOW ACTIVE, HEALTHY GROWTH (WITH EXCEPTIONS MADE FOR SEASONAL DORMANCY). ALL PLANTS NOT MEETING THIS CONDITION SHALL BE REJECTED AND REPLACED BY HEALTHY PLANT MATERIAL PRIOR TO FINAL ACCEPTANCE. b.ALL HARDSCAPE SHALL BE CLEANED PRIOR TO FINAL ACCEPTANCE. c.SODDED AREAS MUST BE ACTIVELY GROWING AND MUST REACH A MINIMUM HEIGHT OF 1 1/2 INCHES BEFORE FIRST MOWING. HYDROMULCHED AREAS SHALL SHOW ACTIVE, HEALTHY GROWTH. BARE AREAS LARGER THAN TWELVE SQUARE INCHES MUST BE RESODDED OR RESEEDED (AS APPROPRIATE) PRIOR TO FINAL ACCEPTANCE. ALL SODDED TURF SHALL BE NEATLY MOWED. GUARANTEE: A.TREES, SHRUBS, GROUNDCVOER SHALL BE GUARANTEED (IN WRITING) FOR A 12 MONTH PERIOD (90 DAYS FOR ANNUAL PLANTING OR AT THE END OF THE SEASONAL COLOR GROWING SEASON, WHICHEVER COMES SOONER) AFTER FINAL ACCEPTANCE. THE CONTRACTOR SHALL REPLACE ALL DEAD MATERIALS AS SOON AS WEATHER PERMITS AND UPON NOTIFICATION OF THE OWNER. B.PLANTS INCLUDING TREES, WHICH HAVE PARTIALLY DIED SO THAT SHAPE, SIZE OR SYMMETRY HAVE BEEN DAMAGED SHALL BE CONSIDERED SUBJECT TO REPLACEMENT. IN SUCH CASES, THE OPINION OF THE OWNER SHALL BE FINAL. C.PLANTS USED FOR REPLACEMENT SHALL BE OF THE SAME SIZE AND KIND AS THOSE ORIGINALLY PLANTED OR SPECIFIED. ALL WORK INCLUDING MATERIALS, LABOR AND EQUIPMENT USED IN REPLACEMENTS SHALL CARRY A 12 MONTH GUARANTEE. ANY DAMAGE INCLUDING RUTS IN LAWN OR BED AREAS INCURRED AS A RESULT OF MAKING REPLACEMENTS SHALL BE IMMEDIATELY REPAIRED. D.WHEN PLANT REPLACEMENTS ARE MADE, PLANTS, SOIL MIX, FERTILIZER AND MULCH ARE TO BE UTILIZED AS ORIGINALLY SPECIFIED AND RE-INSPECTED FOR FULL COMPLIANCE WITH THE CONTRACT REQUIREMENTS. ALL REPLACEMENTS ARE INCLUDED UNDER "WORK" OF THIS SECTION. E.THE OWNER AGREES THAT FOR THE ONE YEAR WARRANTY PERIOD TO BE EFFECTIVE, HE WILL WATER PLANTS AT LEAST TWICE A WEEK DURING DRY PERIODS. F.THE ABOVE GUARANTEE SHALL NOT APPLY WHERE PLANTS DIE AFTER ACCEPTANCE BECAUSE OF DAMAGE DUE TO ACTS OF GOD, VANDALISM, INSECTS, DISEASE, INJURY BY HUMANS, MACHINES, THEFT OR NEGLIGENCE BY OWNER. G.ACCEPTANCE FOR ALL LANDSCAPE WORK SHALL BE GIVEN AFTER FINAL INSPECTION BY THE OWNER PROVIDED THE JOB IS IN A COMPLETE, UNDAMAGED CONDITION AND THERE IS A STAND OF GRASS IN ALL LAWN AREAS. AT THAT TIME, THE OWNER WILL ASSUME MAINTENANCE ON THE ACCEPTED WORK. 1.9 QUALITY ASSURANCE A.COMPLY WITH ALL FEDERAL, STATE, COUNTY AND LOCAL REGULATIONS GOVERNING LANDSCAPE MATERIALS AND WORK. B.EMPLOY PERSONNEL EXPERIENCED AND FAMILIAR WITH THE REQUIRED WORK AND SUPERVISION BY A FOREMAN. C.MAKE CONTACT WITH SUPPLIERS IMMEDIATELY UPON OBTAINING NOTICE OF CONTRACT ACCEPTANCE TO SELECT AND BOOK MATERIALS. D.DEVELOP A PROGRAM OF MAINTENANCE (PRUNING AND FERTILIZATION) WHICH WILL ENSURE THE PURCHASED MATERIALS WILL MEET AND/OR EXCEED PROJECT SPECIFICATIONS. E.DO NOT MAKE PLANT MATERIAL SUBSTITUTIONS. IF THE LANDSCAPE MATERIAL SPECIFIED IS NOT READILY AVAILABLE, SUBMIT PROOF TO LANDSCAPE ARCHITECT ALONG WITH THE PROPOSED MATERIAL TO BE USED IN LIEU OF THE SPECIFIED PLANT. F.AT THE TIME BIDS ARE SUBMITTED, THE CONTRACTOR IS ASSUMED TO HAVE LOCATED THE MATERIALS NECESSARY TO COMPLETE THE JOB AS SPECIFIED. G.OWNER'S REPRESENTATIVE SHALL INSPECT ALL PLANT MATERIAL AND RETAINS THE RIGHT TO INSPECT MATERIALS UPON ARRIVAL TO THE SITE AND DURING INSTALLATION. THE OWNER'S REPRESENTATIVE MAY ALSO REJECT ANY MATERIALS HE/SHE FEELS TO BE UNSATISFACTORY OR DEFECTIVE DURING THE WORK PROCESS. ALL PLANTS DAMAGED IN TRANSIT OR AT THE JOB SITE SHALL BE REJECTED. 1.10 PRODUCT DELIVERY, STORAGE AND HANDLING A.PREPARATION 1. BALLED AND BURLAPPED B&B PLANTS): DIG AND PREPARE SHIPMENT IN A MANNER THAT WILL NOT DAMAGE ROOTS, BRANCHES, SHAPE AND FUTURE DEVELOPMENT. 2. CONTAINER GROWN PLANTS: DELIVER PLANTS IN RIGID CONTAINER TO HOLD BALL SHAPE AND PROTECT ROOT MASS. B.DELIVERY 1. DELIVER PACKAGED MATERIALS IN SEALED CONTAINERS SHOWING WEIGHT, ANALYSIS AND NAME OF MANUFACTURER. PROTECT MATERIALS FROM DETERIORATION DURING DELIVERY AND WHILE STORED ON SITE. 2. DELIVER ONLY PLANT MATERIALS THAT CAN BE PLANTED IN ONE DAY UNLESS ADEQUATE STORAGE AND WATERING FACILITIES ARE AVAILABLE ON SITE 3. PROTECT ROOT BALLS BY HEELING IN WITH SAWDUST OR OTHER APPROVED MOISTURE RETAINING MATERIAL IF NOT PLANTED WITHIN 24 HOURS OF DELIVERY. 4. PROTECT PLANTS DURING DELIVERY TO PREVENT DAMAGE TO ROOT BALL OR DESICCATION OF LEAVES. 5. KEEP PLANTS MOIST AT ALL TIMES. COVER ALL MATERIALS DURING TRANSPORT. 6. NOTIFY OWNERS REPRESENTATIVE OF DELIVERY 72 HOURS PRIOR TO DELIVERY OF PLANT MATERIAL AT JOB SITE. 7. REMOVE REJECTED PLANT MATERIAL IMMEDIATELY FROM JOB SITE. 8. TO AVOID DAMAGE OR STRESS, DO NOT LIFT, MOVE, ADJUST TO PLUMB, OR OTHERWISE MANIPULATE PLANTS BY TRUNK OR STEMS. PART 2 - PRODUCTS 2.1 PLANT MATERIALS A.GENERAL: WELL FORMED NO. 1 GRADE OR BETTER NURSERY GROWN STOCK. LISTED PLANT HEIGHTS ARE FROM TOPS OF FOOT BALLS TO NOMINAL TOPS OF PLANTS. PLANT SPREAD REFERS TO NOMINAL OUTER WIDTH OF THE PLANT NOT THE OUTER LEAF TIPS. PLANTS SHALL BE INDIVIDUALLY APPROVED BY THE OWNERS REPRESENTATIVE AND THEIR DECISION AS TO THEIR ACCEPTABILITY SHALL BE FINAL. B.QUANTITIES: THE DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY. ANYTHING CALLED FOR ON ONE AND NOT THE OTHER IS AS BINDING AS IF SHOWN AND CALLED FOR ON BOTH. THE PLANT SCHEDULE IS AN AID TO BIDDERS ONLY. CONFIRM ALL QUANTITIES ON PLAN. C.QUANTITIES AND SIZE: PLANT MATERIALS SHALL CONFORM TO THE SIZE GIVEN ON THE PLAN AND SHALL BE HEALTHY, WELL SHAPED, FULL BRANCHED AND WELL ROOTED. SYMMETRY IS ALSO IMPERATIVE. PLANTS SHALL BE FREE FROM INSECTS, INJURY, DISEASE, BROKEN BRANCHES, DISFIGUREMENTS, INSECT EGGS AND ARE TO BE OF SPECIMEN QUALITY. D.APPROVAL: ALL PLANTS WHICH ARE FOUND UNSUITABLE IN GROWTH OR ARE UNHEALTHY, BADLY SHAPED OR UNDERSIZED WILL BE REJECTED BY THE OWNERS REPRESENTATIVE EITHER BEFORE OR AFTER PLANTING AND SHALL BE REMOVED AT THE EXPENSE OF THE LANDSCAPE CONTRACTOR AND REPLACED WITH ACCEPTABLE SPECIMENS. E.TREES SHALL BE HEALTHY, FULL BRANCHED, WELL SHAPED AND SHALL MEET THE MINIMUM REQUIREMENTS AS SPECIFIED ON THE PLANT SCHEDULE. ALL TREES SHALL BE OBTAINED FROM SOURCES WITHIN 200 MILES OF THE PROJECT SITE IF POSSIBLE, AND WITH SIMILAR CLIMACTIC CONDITIONS. F.PRUNING: ALL PRUNING OF TREES AND SHRUBS SHALL BE EXECUTED BY THE LANDSCAPE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER, PRIOR TO FINAL ACCEPTANCE. G.PLANTS SHALL CONFORM TO THE MEASUREMENTS SPECIFIED, EXCEPT THE PLANTS LARGER THAN THOSE SPECIFIED MAY BE USED. USE OF LARGER PLANTS SHALL NOT INCREASE THE CONTRACT PRICE. H.WHERE MATERIALS ARE PLANTED IN MASSES, PROVIDE PLANTS OF UNIFORM SIZE. I.ROOT SYSTEMS SHALL BE HEALTHY, DENSELY BRANCHED, FIBROUS ROOT SYSTEMS, NON-POT-BOUND, FREE FROM ENCIRCLING AND/OR GIRDLING ROOTS, AND FREE FROM ANY OTHER ROOT DEFECTS (SUCH AS J-SHAPED ROOTS). J.ALL TREES SHALL BE STANDARD IN FORM, UNLESS OTHERWISE SPECIFIED. TREES WITH CENTRAL LEADERS WILL NOT BE ACCEPTED IF LEADER IS DAMAGED OR REMOVED. PRUNE ALL DAMAGED TWIGS AFTER PLANTING K.TREE TRUNKS TO BE STURDY, EXHIBIT HARDENED SYSTEMS AND VIGOROUS AND FIBROUS ROOT SYSTEMS, NOT ROOT OR POT BOUND. L.TREES WITH DAMAGED OR CROOKED LEADERS, BARK ABRASIONS, SUNSCALD, DISFIGURING KNOTS, OR\INSECT DAMAGE WILL BE REJECTED. M.CALIPER MEASUREMENTS FOR STANDARD (SINGLE TRUNK) TREES SHALL BE AS FOLLOWS: SIX INCHES ABOVE THE ROOT FLARE FOR TREES UP TO AND INCLUDING FOUR INCHES IN CALIPER, AND TWELVE INCHES ABOVE THE ROOT FLARE FOR TREES EXCEEDING FOUR INCHES IN CALIPER N.MULTI-TRUNK TREES SHALL BE MEASURED BY THEIR OVERALL HEIGHT, MEASURED FROM THE TOP OF THE ROOT BALL. O.ANY TREE OR SHRUB SHOWN TO HAVE EXCESS SOIL PLACED ON TOP OF THE ROOT BALL, SO THAT THE ROOT FLARE HAS BEEN COMPLETELY COVERED, SHALL BE REJECTED. P.SOD: PROVIDE WELL-ROOTED SOD OF THE VARIETY NOTED ON THE PLANS. SOD SHALL BE CUT FROM HEALTHY, MATURE TURF WITH SOIL THICKNESS OF 3/4" TO 1". EACH PALLET OF SOD SHALL BE ACCOMPANIED BY A CERTIFICATE FROM SUPPLIER STATING THE COMPOSITION OF THE SOD. 2.2 SOIL PREPARATION MATERIALS A.SANDY LOAM: 1. FRIABLE, FERTILE, DARK, LOAMY SOIL, FREE OF CLAY LUMPS, SUBSOIL, STONES AND OTHER EXTRANEOUS MATERIAL AND REASONABLY FREE OF WEEDS AND FOREIGN GRASSES. LOAM CONTAINING DALLASGRASS OR NUTGRASS SHALL BE REJECTED. 2. PHYSICAL PROPERTIES AS FOLLOWS: a.CLAY – BETWEEN 7-27% b.SILT – BETWEEN 15-25% c.SAND – LESS THAN 52% 3. ORGANIC MATTER SHALL BE 3%-10% OF TOTAL DRY WEIGHT. 4. IF REQUESTED, LANDSCAPE CONTRACTOR SHALL PROVIDE A CERTIFIED SOIL ANALYSIS CONDUCTED BY AN APPROVED SOIL TESTING LABORATORY VERIFYING THAT SANDY LOAM MEETS THE ABOVE REQUIREMENTS. B.ORGANIC MATERIAL: COMPOST WITH A MIXTURE OF 80% VEGETATIVE MATTER AND 20% ANIMAL WASTE. INGREDIENTS SHOULD BE A MIX OF COURSE AND FINE TEXTURED MATERIAL. C.PREMIXED BEDDING SOIL AS SUPPLIED BY VITAL EARTH RESOURCES, GLADEWATER, TEXAS; PROFESSIONAL BEDDING SOIL AS SUPPLIED BY LIVING EARTH TECHNOLOGY, DALLAS, TEXAS OR ACID GRO MUNICIPAL MIX AS SUPPLIED BY SOIL BUILDING SYSTEMS, DALLAS, TEXAS OR APPROVED EQUAL. D.SHARP SAND: SHARP SAND MUST BE FREE OF SEEDS, SOIL PARTICLES AND WEEDS. E.MULCH: DOUBLE SHREDDED HARDWOOD MULCH, PARTIALLY DECOMPOSED, DARK BROWN. F.ORGANIC FERTILIZER: FERTILAID, SUSTANE, OR GREEN SENSE OR EQUAL AS RECOMMENDED FOR REQUIRED APPLICATIONS. FERTILIZER SHALL BE DELIVERED TO THE SITE IN ORIGINAL UNOPENED CONTAINERS, EACH BEARING THE MANUFACTURER'S GUARANTEED STATEMENT OF ANALYSIS. G.COMMERCIAL FERTILIZER: 10-20-10 OR SIMILAR ANALYSIS. NITROGEN SOURCE TO BE A MINIMUM 50% SLOW RELEASE ORGANIC NITROGEN (SCU OR UF) WITH A MINIMUM 8% SULFUR AND 4% IRON, PLUS MICRONUTRIENTS. H.PEAT: COMMERCIAL SPHAGNUM PEAT MOSS OR PARTIALLY DECOMPOSED SHREDDED PINE BARK OR OTHER APPROVED ORGANIC MATERIAL. 2.3 MISCELLANEOUS MATERIALS A.STEEL EDGING - SHALL BE 3/16” X 4” X 16” DARK GREEN LANDSCAPE EDGING. DURAEDGE STEEL OR APPROVED EQUAL. B.TREE STAKING - TREE STAKING SOLUTIONS OR APPROVED SUBSTITUTE; REFER TO DETAILS. C.FILTER FABRIC - MIRAFI 1405 BY MIRAFI INC. OR APPROVED SUBSTITUTE. AVAILABLE AT LONE STAR PRODUCTS, INC. (469-523-0444) D.SAND - UNIFORMLY GRADED, WASHED, CLEAN, BANK RUN SAND. E.GRAVEL: WASHED NATIVE PEA GRAVEL, GRADED 1" TO 1.5" F.DECOMPOSED GRANITE - BASE MATERIAL OF NATURAL MATERIAL MIX OF GRANITE AGGREGATE NOT TO EXCEED 1/8” IN DIAMETER COMPOSED OF VARIOUS STAGES OF DECOMPOSED EARTH BASE. G.RIVER ROCK - LOCALLY AVAILABLE NATIVE RIVER ROCK BETWEEN 2”-4” IN DIAMETER. H.PRE-EMERGENT HERBICIDES: ANY GRANULAR, NON-STAINING PRE-EMERGENT HERBICIDE THAT IS LABELED FOR THE SPECIFIC ORNAMENTALS OR TURF ON WHICH IT WILL BE UTILIZED. PRE-EMERGENT HERBICIDES SHALL BE APPLIED PER THE MANUFACTURER'S LABELED RATES. PART 3 - EXECUTION 3.1 PREPARATION A.LANDSCAPE CONTRACTOR TO INSPECT ALL EXISTING CONDITIONS AND REPORT ANY DEFICIENCIES TO THE OWNER. B.ALL PLANTING AREAS SHALL BE CONDITIONED AS FOLLOWS: 1. PREPARE NEW PLANTING BEDS BY SCRAPING AWAY EXISTING GRASS AND WEEDS AS NECESSARY. TILL EXISTING SOIL TO A DEPTH OF SIX (6") INCHES PRIOR TO PLACING COMPOST AND FERTILIZER. APPLY FERTILIZER AS PER MANUFACTURER'S RECOMMENDATIONS. ADD SIX (6") INCHES OF COMPOST AND TILL INTO A DEPTH OF SIX (6") INCHES OF SPECIFIED MULCH (SETTLED THICKNESS). 2. BACKFILL FOR TREE PITS SHALL BE AS FOLLOWS: USE EXISTING TOP SOIL ON SITE (USE IMPORTED TOPSOIL AS NEEDED) FREE FROM LARGE CLUMPS, ROCKS, DEBRIS, CALICHE, SUBSOILS, ETC., PLACED IN NINE (9") INCH LAYERS AND WATERED IN THOROUGHLY. C.GRASS AREAS: 1. BLOCKS OF SOD SHOULD BE LAID JOINT TO JOINT (STAGGERED JOINTS) AFTER FERTILIZING THE GROUND FIRST. ROLL GRASS AREAS TO ACHIEVE A SMOOTH, EVEN SURFACE. THE JOINTS BETWEEN THE BLOCKS OF SOD SHOULD BE FILLED WITH TOPSOIL WHERE THEY ARE GAPED OPEN, THEN WATERED THOROUGHLY. 3.2 INSTALLATION A.MAINTENANCE OF PLANT MATERIALS SHALL BEGIN IMMEDIATELY AFTER EACH PLANT IS DELIVERED TO THE SITE AND SHALL CONTINUE UNTIL ALL CONSTRUCTION HAS BEEN SATISFACTORILY ACCOMPLISHED. B.PLANT MATERIALS SHALL BE DELIVERED TO THE SITE ONLY AFTER THE BEDS ARE PREPARED AND AREAS ARE READY FOR PLANTING. ALL SHIPMENTS OF NURSERY MATERIALS SHALL BE THOROUGHLY PROTECTED FROM THE WINDS DURING TRANSIT. ALL PLANTS WHICH CANNOT BE PLANTED AT ONCE, AFTER DELIVERY TO THE SITE, SHALL BE WELL PROTECTED AGAINST THE POSSIBILITY OF DRYING BY WIND AND BALLS OF EARTH OF B & B PLANTS SHALL BE KEPT COVERED WITH SOIL OR OTHER ACCEPTABLE MATERIAL. ALL PLANTS REMAIN THE PROPERTY OF THE CONTRACTOR UNTIL FINAL ACCEPTANCE. C.POSITION THE TREES AND SHRUBS IN THEIR INTENDED LOCATION AS PER PLAN. D.NOTIFY THE OWNER'S AUTHORIZED REPRESENTATIVE FOR INSPECTION AND APPROVAL OF ALL POSITIONING OF PLANT MATERIALS. E.EXCAVATE PITS WITH VERTICAL SIDES AND HORIZONTAL BOTTOM. TREE PITS SHALL BE LARGE ENOUGH TO PERMIT HANDLING AND PLANTING WITHOUT INJURY TO BALLS OF EARTH OR ROOTS AND SHALL BE OF SUCH DEPTH THAT,WHEN PLANTED AND SETTLED, THE CROWN OF THE PLANT SHALL BEAR THE SAME RELATIONSHIP TO THE FINISH GRADE AS IT DID TO SOIL SURFACE IN ORIGINAL PLACE OF GROWTH. THE SIDES OF THE HOLE SHOULD BE ROUGH AND JAGGED, NEVER SLICK OR GLAZED. F.SHRUB AND TREE PITS SHALL BE NO LESS THAN TWENTY-FOUR (24") INCHES WIDER THAN THE LATERAL DIMENSION OF THE EARTH BALL AND SIX (6") INCHES DEEPER THAN IT'S VERTICAL DIMENSION. REMOVE AND HAUL FROM SITE ALL ROCKS AND STONES OVER THREE-QUARTER (3 4") INCH IN DIAMETER. PLANTS SHOULD BE THOROUGHLY MOIST BEFORE REMOVING CONTAINERS. G.PERCOLATION TEST: FILL THE HOLE WITH WATER. IF THE WATER LEVEL DOES NOT PERCOLATE WITHIN 24 HOURS, THE TREE NEEDS TO MOVE TO ANOTHER LOCATION OR HAVE DRAINAGE ADDED. INSTALL A PVC STAND PIPE PER TREE IF THE PERCOLATION TEST FAILS. H.BACKFILL ONLY WITH 5 PARTS EXISTING SOIL OR SANDY LOAM AND 1 PART BED PREPARATION. WHEN THE HOLE IS DUG IN SOLID ROCK, TOPSOIL FROM THE SAME AREA SHOULD NOT BE USED. CAREFULLY SETTLE BY WATERING TO PREVENT AIR POCKETS. REMOVE THE BURLAP FROM THE TOP 13 OF THE BALL, AS WELL AS ALL NYLON, PLASTIC STRING AND WIRE. CONTAINER TREES WILL USUALLY BE ROOT BOUND, IF SO FOLLOW STANDARD NURSERY PRACTICE OF ‘ROOT SCORING’. I.DO NOT WRAP TREES. J.DO NOT OVER PRUNE. K.REMOVE NURSERY TAGS AND STAKES FROM ALL PLANTS L.REMOVE BOTTOM OF PLANT BOXES PRIOR TO PLACING PLANTS. REMOVE SIDES AFTER PLACEMENT AND PARTIAL BACKFILLING. M.REMOVE UPPER THIRD OF BURLAP FROM BALLED AND BURLAPPED TREES AFTER PLACEMENT. N.PLACE PLANT UPRIGHT AND PLUMB IN CENTER OF HOLE. ORIENT PLANTS FOR BEST APPEARANCE. O.MULCH THE TOP OF THE BALL. DO NOT PLANT GRASS ALL THE WAY TO THE TRUNK OF THE TREE. LEAVE THE AREA ABOVE THE TOP OF THE BALL AND MULCH WITH AT LEAST TWO (2") INCHES OF SPECIFIED MULCH. P.ALL PLANT BEDS AND TREES TO BE MULCHED WITH A MINIMUM SETTLED THICKNESS OF TWO (2") INCHES OVER THE ENTIRE BED OR PIT. Q.OBSTRUCTION BELOW GROUND: IN THE EVENT THAT ROCK, OR UNDERGROUND CONSTRUCTION WORK OR OBSTRUCTIONS ARE ENCOUNTERED IN ANY PLANT PIT EXCAVATION WORK TO BE DONE UNDER THIS SECTION, ALTERNATE LOCATIONS MAY BE SELECTED BY THE OWNER. WHERE LOCATIONS CANNOT BE CHANGED, THE OBSTRUCTIONS SHALL BE REMOVED TO A DEPTH OF NOT LESS THAN THREE (3') FEET BELOW GRADE AND NO LESS THAN SIX (6") INCHES BELOW THE BOTTOM OF BALL WHEN PLANT IS PROPERLY SET AT THE REQUIRED GRADE. THE WORK OF THIS SECTION SHALL INCLUDE THE REMOVAL FROM THE SITE OF SUCH ROCK OR UNDERGROUND OBSTRUCTIONS ENCOUNTERED AT THE COST OF THE LANDSCAPE CONTRACTOR. R.TREES AND LARGE SHRUBS SHALL BE STAKED AS SITE CONDITIONS REQUIRE. POSITION STAKES TO SECURE TREES AGAINST SEASONAL PREVAILING WINDS. S.PRUNING AND MULCHING: PRUNING SHALL BE DIRECTED BY THE LANDSCAPE ARCHITECT AND SHALL BE PRUNED IN ACCORDANCE WITH STANDARD HORTICULTURAL PRACTICE FOLLOWING FINE PRUNING, CLASS I PRUNING STANDARDS PROVIDED BY THE NATIONAL ARBORIST ASSOCIATION. 1.DEAD WOOD, SUCKERS, BROKEN AND BADLY BRUISED BRANCHES SHALL BE REMOVED. GENERAL TIPPING OF THE BRANCHES IS NOT PERMITTED. DO NOT CUT TERMINAL BRANCHES. 2.PRUNING SHALL BE DONE WITH CLEAN, SHARP TOOLS. 3.IMMEDIATELY AFTER PLANTING OPERATIONS ARE COMPLETED, ALL TREE PITS SHALL BE COVERED WITH A LAYER OF ORGANIC MATERIAL TWO (2") INCHES IN DEPTH. THIS LIMIT OF THE ORGANIC MATERIAL FOR TREES SHALL BE THE DIAMETER OF THE PLANT PIT. Q.STEEL EDGE INSTALLATION: EDGE SHALL BE ALIGNED AS INDICATED ON PLANS. STAKE OUT LIMITS OF STEEL CURBING AND OBTAIN OWNERS APPROVAL PRIOR TO INSTALLATION. 1.ALL STEEL CURBING SHALL BE FREE OF KINKS AND ABRUPT BENDS. 2.TOP OF EDGING SHALL BE 12" MAXIMUM HEIGHT ABOVE FINAL FINISHED GRADE. 3.STAKES ARE TO BE INSTALLED ON THE PLANTING BED SIDE OF THE CURBING, AS OPPOSED TO THE GRASS SIDE. 4.DO NOT INSTALL STEEL EDGING ALONG SIDEWALKS OR CURBS. 5.CUT STEEL EDGING AT 45 DEGREE ANGLE WHERE EDGING MEETS SIDEWALKS OR CURBS. 3.3 CLEANUP AND ACCEPTANCE A.CLEANUP: DURING THE WORK, THE PREMISES SHALL BE KEPT NEAT AND ORDERLY AT ALL TIMES. STORAGE AREAS FOR ALL MATERIALS SHALL BE SO ORGANIZED SO THAT THEY, TOO, ARE NEAT AND ORDERLY. ALL TRASH AND DEBRIS SHALL BE REMOVED FROM THE SITE AS WORK PROGRESSES. KEEP PAVED AREAS CLEAN BY SWEEPING OR HOSING THEM AT END OF EACH WORK DAY. B.REPAIR RUTS, HOLES AND SCARES IN GROUND SURFACES. C.ENSURE THAT WORK IS COMPLETE AND PLANT MATERIALS ARE IN VIGOROUS AND HEALTHY GROWING CONDITION. D.UPON COMPLETION OF THE WORK, THE LANDSCAPE CONTRACTOR SHALL PROVIDE THE SITE CLEAN, FREE OF DEBRIS AND TRASH, AND SUITABLE FOR USE AS INTENDED. THE LANDSCAPE CONTRACTOR SHALL THEN REQUEST AN INSPECTION BY THE OWNER TO DETERMINE FINAL ACCEPTABILITY. E.WHEN/IF THE INSPECTED PLANTING WORK DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS, THE LANDSCAPE CONTRACTOR SHALL REPLACE AND/OR REPAIR THE REJECTED WORK TO THE OWNER'S SATISFACTION WITHIN 24 HOURS. F.THE LANDSCAPE MAINTENANCE PERIOD WILL NOT COMMENCE UNTIL THE LANDSCAPE WORK HAS BEEN RE-INSPECTED BY THE OWNER AND FOUND TO BE ACCEPTABLE. AT THAT TIME, A WRITTEN NOTICE OF FINAL ACCEPTANCE WILL BE ISSUED BY THE OWNER, AND THE MAINTENANCE AND GUARANTEE PERIODS WILL COMMENCE. END OF SECTION TREE PLANTING N.T.S. 1 (3) 2" DIA. X 8' LENGTH LARGE METAL "T" POSTS IN UNDISTURBED SOIL TIE TO STAKE WITH PLASTIC CHAIN TIES NEVER CUT LEADER SET TOP OF ROOT BALL 3" ABOVE FINISH GRADE. MULCH - 3" MIN. DEPTH BUILD 4" HT. SAUCER AROUND PLANTING PIT WITH TOPSOIL. 6" MIN. UNDISTURBED SUBGRADE 12" MIN. ALL SIDES 12" MIN. ALL SIDES PLACE TWO ON PREVAILING WIND SIDE OF TREE (PAINTED BLACK) BACK FILL / PLANTING SOIL MIX. TILL IN WITH PARTS EXISTING SOIL, EXCLUDING LARGE CLODS AND ROCKS. FINISH GRADE ADMINISTRATIVELY APPROVED ON 01/10/2025 Matthew S. Steer, AICP, LEED® Green Associate Property Lines adjusted to reflect Approved Concept Plan S BELT LINE ROAD120' R.O.W.VOL. 4499, PAGE 159, D.R.D.C.T.PAD SITE 51.04 acQSR2,200sf1" IRRIGATION METER, ISOLATION VALVE, WYE STRAINER, 1" RPZ AND MASTER VALVE (REFERENCE CIVIL FOR LOCATION) IRRIGATION CONTROLLER WITH ON-SITE WEATHER MONITOR, WEATHER SENSORS LOCATED PER MANUFACTURE SPECIFICATIONS, VERIFY LOCATION IN THE FIELD WITH OWNER AND CONTRACTOR 1.5" Mainline1.5" Mainline 1.5" Mainline1.5" Mainline1.5" Mainline10a 10a 10a 10a 10a 10a 10a 10a 10a 10a 10a 10a 10a 10a 10a 10a 10a 12a 12a 15a 12a 15sst 15sst 6a 6a 6a 6a 8a 8a 8a 8a 8a 12a 12a 12a 12a 12a 12a 12a12a 10a 10a 10a 12a 12a 12a 12a 12a 10a 10a 10a 12a12a 12a 12a 12a 12a 12a 12a 12a 6a 6a 8a 8a 10a 10a 8a 8a 8a 8a 8a 8a 6a 6a 10a 10a 10a 10a 8a 8a R16 R16 R16 R16 R16 R16 R8 R8 R8 R14 R14 R14 25R25R 25R 25R 25R R8R8 R8 25R R16 R16 R20 R20 R20 R20 R20 R16 R14 10.51" T1 (TREE BUBBLER) 8.01" T2 (TREE BUBBLER) NOTE: SEE DETAIL FOR TREE ZONE'S LATERAL CONNECTIONS. NOTE: SEE DETAIL FOR TREE ZONE'S LATERAL CONNECTIONS. DRIP ZONE #1 DRIP ZONE #1 DRIP ZONE #2 DRIP ZONE #2 DRIP ZONE #3 DRIP ZONE #3 DRIP ZONE #4 (PLANTERS) DRIP ZONE #4 (PLANTERS) 17.11.5" D1 DRIP (SHRUBS) 18" LINE SPACING 8.61" D2 DRIP (SHRUBS) 18" LINE SPACING 5.21" D3 DRIP (SHRUBS) 18" LINE SPACING 2.01" D4 DRIP (PLANTERS) 11.31" R1 ROTOR/ ROTARY (TURF) 9.61" R2 ROTOR/ ROTARY (TURF) 21.51.5" S1 SPRAYS (TURF) 16.41" S2 SPRAYS (TURF) 19.01.5" S3 SPRAYS (TURF) 23.71.5" S4 SPRAYS (TURF) 3" Main Sleeve 3" Lateral Sleeve 2" Wire Sleeve 3" Main Sleeve 3" Lateral Sleeve 2" Wire Sleeve 3" Main Sleeve 3" Lateral Sleeve 2" Wire Sleeve 2" Wire Sleeve (3)3" Lateral Sleeve 3" Main Sleeve (2)3" Lateral Sleeve 2" Wire Sleeve 3" Main Sleeve (2)3" Lateral Sleeve 2" Wire Sleeve 3" Lateral Sleeve (2)3" Lateral Sleeve (2)3" Lateral Sleeve 3" Lateral Sleeve 3" Planter Sleeve 3" Planter Sleeve 3" Planter Sleeve 3" Planter Sleeve 3" Planter Sleeve 3" Planter Sleeve 12a 8a 8a 8a 8a 8a 8a 8a 8a 8a 8a 8a (2)3" Lateral Bore/Sleeve 3" Main Sleeve 2" Wire Sleeve REVISIONSOFNo.DateApp.SHEET NO.© 2024 QuiddityJOB NO.:SCALE:DESIGNED BY.:HTFCHECKED BY:ACHA B C D E F 1234DATE:DRAWN BY:AMAS SHOWNJANUARY 202517007-0146-02Texas Board of Professional Engineers and Land Surveyors Reg. No. F-232904500 Mercantile Plaza Drive, Suite 210 Fort Worth, Texas 76137 682.268.2200 SALAD AND GO - COPPELL - I-635 AND BELT LINESTATE O F TE X A SL I C E NSED I R GI ATORR 23713 CODY S RICHARDSON a W R AWR Designs, LLC P.O. Box 1746 Aledo, Texas 76008 amanda@awr-designs.com c. 512.517.5589 2-19-24 1570 S BELT LINE, COPPELL, TX 750191570 S BELT LINELOT 5, BLOCK AVICTORY AT COPPELL ADDITIONCOPPELL, TX 75019L2.01IRRIGATION PLANSLEEVING NOTES 1.PIPING AND CONTROL WIRES SHALL BE INSTALLED IN SEPARATE SLEEVES UNDER PAVING. REFERENCE DRAWINGS FOR SLEEVE SIZE AND LOCATION. 2.SLEEVES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. 3.INSTALLATION OF SLEEVES SHALL BE TWENTY - FOUR (24") BELOW TOP OF PAVEMENT OR FINISHED GRADE. 4.SLEEVES SHALL EXTEND ONE (1') FOOT BEYOND EDGE OF ALL PAVEMENT AND STAKED FOR LOCATION. 5.ALL SLEEVES SHALL BE SCHEDULE 40 PVC PIPE, CAPPED ON BOTH ENDS AND SIZED AT LEAST TWO TIMES LARGER THAN THE DIAMETER OF THE PIPE INSIDE THE SLEEVE. 6.SLEEVE LOCATIONS SHALL BE MARKED ONTO THE CURB WITH A SAWCUT OF TWO PARALLEL LINES THAT ARE TWO (2") INCHES LONG AND ONE (1") APART. 7.CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF SLEEVES AND SHALL ALSO BE RESPONSIBLE FOR LOCATING ANY SLEEVE THAT CANNOT BE FOUND DURING THE INSTALLATION OF THE SYSTEM. 8.CONTRACTOR SHALL FURNISH OWNER AND IRRIGATION CONTRACTOR WITH AN 'AS-BUILT' DRAWING SHOWING ALL SLEEVE LOCATIONS. IRRIGATION GENERAL NOTES 1.THE IRRIGATION CONTRACTOR SHALL COORDINATE INSTALLATION OF THE IRRIGATION SYSTEM WITH THE LANDSCAPE CONTRACTOR SO THAT ALL PLANT MATERIAL WILL BE WATERED IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. 2.THE CONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY THE IRRIGATION DESIGNER OF SITE CONDITIONS OR ASSUME FULL RESPONSIBILITY FOR ANY AND ALL ON SITE REVISIONS NECESSARY. 3.CONTRACTOR TO VERIFY DESIGN AND ITS INTENT TO PROVIDE FULL COVERAGE TO ALL NEW PLANTING MATERIAL. 4.NOTIFY IRRIGATION DESIGNER OF ANY LAYOUT DISCREPANCIES PRIOR TO BIDDING. 5.LOCATE ALL UTILITIES AND SITE LIGHTING CONDUITS BEFORE IRRIGATION INSTALLATION BEGINS. 6.IRRIGATION CONTRACTOR TO PROCURE ALL PERMITS, LICENSES AND GIVE ALL NECESSARY NOTICES THROUGHOUT THE DURATION OF THE PROJECT. 7.THE CONTRACTOR SHALL BE A REGISTERED LICENSED IRRIGATOR IN GOOD STANDING WITH THE STATE OF TEXAS BOARDS AND REGULATORS. 8.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL PLANT MATERIAL UPON ACCEPTANCE AND THROUGH THE WARRANTY PERIOD FOR DAMAGE DUE TO IRRIGATION SYSTEM FAILURE. 9.ALL ASPECTS OF THE IRRIGATION INSTALLATION SHALL CONFORM WITH THE PROPER GOVERNING AUTHORITIES, CODES AND ORDINANCES. 10.SLEEVES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. SLEEVE MATERIAL SHALL BE SCHEDULE 40, SIZE AS INDICATED ON PLAN. REFER TO SLEEVING NOTES. 11.ALL MAIN LINE AND LATERAL LINE PIPING IN PLANTING AND LAWN AREAS SHALL HAVE A MINIMUM OF 12 INCHES OF COVER. ALL PIPING UNDER PAVING SHALL HAVE A MINIMUM OF 18 INCHES OF COVER. CONTRACTOR TO VERIFY LOCAL FREEZE DEPTHS AND ADJUST DEPTH OF COVER ACCORDINGLY. 12.ZONE VALVES SHALL NOT BE LOCATED WITHIN THREE (3') FEET OF ANY DRIVEWAY, TRAFFIC AISLE, ISLAND ETC. WHERE THEY WILL BE DAMAGED BY VEHICLES DRIVING OVER CURBS. 13.ALL NOZZLES IN PARKING LOT ISLANDS AND PLANTING BEDS SHALL BE LOW ANGLE NOZZLES TO MINIMIZE OVER SPRAY ON PAVEMENT SURFACES. 14.AUTOMATIC CONTROLLER SHALL BE INSTALLED AT LOCATION SHOWN. POWER (120V) SHALL BE LOCATED IN A JUNCTION BOX WITHIN FIVE (5') FEET OF CONTROLLER, LOCATION BY OTHER TRADES. RAIN AND FREEZE SENSORS SHALL BE INSTALLED WITH EACH CONTROLLER. 15.ELECTRICAL SPLICES SHOULD BE LOCATED AT EACH VALVE AND CONTROLLER ONLY. 16.PROVIDE A 3/4" BLOW DOWN DRAIN TEE TO ALLOW WATER TO BE BLOWN FROM THE IRRIGATION LINES/SYSTEM. 17.DISTURBED AREAS IN NEED OF TURF ESTABLISHMENT MAY EXIST BEYOND COVERAGE LIMITS OF THE PERMANENT IRRIGATION SYSTEM. IN THESE AREAS, CONTRACTOR TO DETERMINE A TEMPORARY MEANS TO ESTABLISH NECESSARY TURF. CONTRACTOR IS ENCOURAGED TO BEGIN TURF ESTABLISHMENT IMMEDIATELY UPON FINAL GRADE IN ACCORDANCE WITH AND TO SATISFY SWPPP. 18.PROVIDE WITH OWNER A COPY OF ALL INSTALLED EQUIPMENT AND LINES (AS BUILT PLANS.) 19.PLACE COPY OF ZONE MAP WITH ALL ZONE VALVE LOCATIONS SHOWN AND APPROVED IRRIGATION PLAN IN PROTECTIVE JACKET IN MAIN CONTROL PANEL. 20.IRRIGATION IN TEXAS IS REGULATED BY: THE TEXAS COMMISSION ON ENVIRONMENTAL QUALITY (TCEQ) MC-178 / PO BOX 13087 AUSTIN, TEXAS 78711-3087 WWW.TECQ.STATE.TX.US. IRRIGATION PROJECT NOTES 1.THE LOCATION OF MAINLINE AND VALVES ON THIS PLAN MAY BE SHOWN IN PAVED AREAS FOR DESIGN CLARITY ONLY. IRRIGATION ELEMENTS HAVE BEEN SHOWN ON THIS PLAN AS ACCURATELY AS POSSIBLE WITHOUT THE FORFEIT OF DESIGN CLARITY AND INTENT. ALL PIPES AND VALVES SHALL BE INSTALLED WITHIN PERVIOUS AREAS. ALL PIPE AND WIRES THAT CROSS UNDER PAVING SHALL BE INSTALLED IN SEPARATE SLEEVES AS SPECIFIED. 2.ALL SPRINKLER EQUIPMENT NUMBERS REFERENCE THE HUNTER EQUIPMENT CATALOG UNLESS OTHERWISE INDICATED. 3.TEN DAYS PRIOR TO START OF CONSTRUCTION, IRRIGATION CONTRACTOR SHALL VERIFY STATIC WATER PRESSURE. THE IRRIGATION SYSTEM FOR THIS SITE IS DESIGNED TO OPERATE WITH A PRESSURE OF SIXTY FIVE (65 PSI) POUNDS PER SQUARE INCH. SHOULD THE DESIGN PRESSURE FOR THE SYSTEM BE HIGHER THAN THE EXISTING PRESSURE, THE IRRIGATION CONTRACTOR SHALL NOTIFY THE IRRIGATION DESIGNER IMMEDIATELY. 4.IRRIGATION CONTRACTOR SHALL COORDINATE THE LOCATION OF THE CONTROLLER AND SENSORS WITH THE GENERAL CONTRACTOR AND OWNER. A 110 VOLT ELECTRICAL SERVICE TO POWER THE IRRIGATION CONTROLLER SHALL BE PROVIDED BY THE GENERAL CONTRACTOR AT THE LOCATION SHOWN ON THIS PLAN. 5.WATER SERVICE TAP, METER AND LEAD FOR THE IRRIGATION SYSTEM SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. SERVICE LINE AND METER SHALL BE SIZED AS NOTED ON THIS PLAN. 6.TYPE AND INSTALLATION OF THE WATER METER AND BACK FLOW PREVENTION DEVICE SHALL BE DETERMINED BY THE GOVERNING AUTHORITY. AN ISOLATION VALVE SHALL BE PROVIDED BETWEEN THE WATER METER AND BACK FLOW DEVICE. 7.ALL CALCULATIONS FOR THIS IRRIGATION SYSTEM ARE BASED ON PRODUCTS AND EQUIPMENT INFORMATION PROVIDED BY HUNTER. INSTALLATION OF THESE PRODUCTS SHALL NOT EXCEED MANUFACTURERS RECOMMENDATIONS. 8.REFERENCE HUNTER GUIDELINES AND SPECIFICATIONS PRIOR TO INSTALLATION. CONFIRM REQUIREMENTS FOR CONTROLLER, WATERPROOF CONNECTIONS, GROUNDING, SURGE PROTECTORS, DECODERS, VALUES, AND WIRING PRIOR TO INSTALLATION. HUNTER TECHNICAL SERVICES (760) 591-7383. WWW.HUNTERINDUSTRIES.COM 9.SPRAY HEADS LOCATED IN TURF AREAS SHALL BE HUNTER PROS-04-PRS30 SPRAY BODIES WITH PRO ADJUSTABLE NOZZLES, FIXED ARC NOZZLES, AND STRIP PATTERN NOZZLES RATE AND AS INDICATED ON THE PLAN. 10.MP ROTATOR HEADS SHALL BE PROS-04-PRS40 SPRAY BODIES WITH MP1000, MP2000, MP3000, MP3500, MPRSS530, MPRCS515, AND MPLCS515 NOZZLES. RADIUS LESS THAN 12 FEET SHALL BE PRS30 AND PRS40 SPRAY BODIES WITH MP800SR. MP ROTATOR AREAS WITH LESS THAN 90 DEGREES SHALL BE MP CORNER NOZZLES. 11.IRRIGATION ROTOR HEADS SHALL BE PGP ULTRA MODELS PGP-04-PRB WITH MPR NOZZLES. 12.IRRIGATION REMOTE CONTROL VALVES SHALL BE 1" AND/OR 1.5" HUNTER ICV AS INDICATED. PRIOR TO ALL REMOTE CONTROL VALVES, INSTALL A NOMINALLY SIZED BALL VALVE WITHIN THE SAME BOX. 13.SIZE OF VALVES ARE AS SHOWN ON PLAN. VALVES SHALL BE INSTALLED IN APPROVED BOXES WITH COVERS LARGE ENOUGH TO PERMIT MANUAL OPERATION, REMOVAL OF SOLENOID AND / OR VALVE COVER WITHOUT ANY EARTH EXCAVATION. OWNERS MAY ELECT LOCKING BOXES ON A PROJECT BY PROJECT BASIS. 14.QUICK COUPLING VALVES SHALL BE HUNTER INSTALLED PER DETAIL SHOWN. SWING JOINTS SHALL BE CONSTRUCTED USING 3 4" SCHEDULE 80 ELBOWS. CONTRACTOR SHALL SUPPLY OWNER WITH TWO (2) HQ-3-RC COUPLERS WITH (2) HK-33 KEYS AND TWO (2) HS-0 HOSE SWIVELS AS PART OF THIS CONTRACT. 15.IRRIGATION SYSTEM AUTOMATIC CONTROLLER SHALL BE HUNTER PRO-C-12 STATION - PC-1200 WITH RAIN AND FREEZE SENSORS. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. CONFIRM WIRING, GROUNDING AND SURGE PROTECTION REQUIREMENTS BEFORE INSTALLING. 16.DRIP IRRIGATION REMOTE CONTROL VALVES SHALL BE HUNTER ICZ-101-LF-40 AS INDICATED. DRIP TUBING SHALL BE HUNTER HDL-06-12-CV. 17.INSTALL DRIP TUBING/LINES PER MANUFACTURERS RECOMMENDATIONS. USE PLD-LOC FITTINGS PLD-LOC 075, PLD-LOC 050, PLD-LOC ELB, PLD-LOC CPL, PLD-LOC CAP, PLD-LOC TEE, PLD-LOC OR USE FHS BARB FITTINGS PLD-075, PLD-050, PLD-ELB, PLD-CPL, PLD-CAP, PLD-TEE, PLD-075-TBTEE, PLD-BV. USE ECO-INDICATOR ECO-ID. USE LINE FLUSHING VALVE HUNTER AFV-B. 18.DRIP TUBING SHALL BE SPACED 18" APART IN SHRUB AREAS. REFER TO MANUFACTURERS RECOMMENDATIONS. 19.PATIO PLANTER DRIP TUBING SHALL BE HUNTER MLD-05-06-BL WITH 1/4" BARBED FITTINGS. USE FILTER REGULATORS HY-100. SEE DETAIL OTHER SHEET. PRIOR COORDINATE SLEEVING INSTALLATION PRIOR TO FLATWORK. 20.TREE BUBBLERS SHALL USE HUNTER PROS-06-PRS30 BODIES WITH HUNTER MULTI-STREAM BUBBLERS MODEL MSBN-50H NOZZLES. 21.ALL VALVE CONTROL WIRE SHALL BE SIZED PER MANUFACTURER GUIDELINES BY THE CONTRACTOR ACCORDING TO THE ACTUAL FIELD DISTANCE. ALL CONNECTIONS SHALL BE WATER-PROOF, KEPT TO A MINIMUM, AND LOCATED IN AN APPROVED BOX. 22.USE HUBBELL HOT BOX DROP OVER ENCLOSURE AND POLYMER CONCRETE MOUNTING PAD FOR BACKFLOW DEVICE. PRODUCE LP010026023T. Know what's below. before you dig.Call R 10a VALVE STATION # (WHERE D = DRIP TUBING, S = SPRAY, R = ROTOR, T = TREE DRIP) VALVE SIZE GPM8.81" D1 IRRIGATION LEGEND SYMBOL DESCRIPTION MANUFACTURER MODEL NO. SPRAYS WITH PRO ADJ. NOZZLES HUNTER PROS-04-PRS30 R20 MP ROTATORS HUNTER PROS-04-PRS40 MULTI-STREAM BUBBLERS HUNTER PROS-06-PRS30 W/ MSBN50H NOZZLES REMOTE CONTROL VALVE HUNTER ICV 1" REDUCED PRESSURE ZONE FEBCO 860 SERIES HDL DRIPLINE HUNTER HDL-06-12-CV LINE FLUSHING VALVE HUNTER AFV-B PRESSURE OPERATOR INDICATOR HUNTER ECO-ID DRIP CONTROL VALVE HUNTER ICZ-101-LF-40 IRRIGATION LEGEND SYMBOL DESCRIPTION 1" IRRIGATION METER HUNTER - PRO-C-12 STATION - PC-1200 WITH RAIN AND FREEZE SENSORS ISOLATION VALVE LATERAL PIPING REFER TO PLAN CLASS 200 PVC MAINLINE PIPING REFER TO PLAN SCH. 40 PVC, SIZED AS SHOWN IRRIGATION SLEEVE, SCH. 40 PVC, MIN. TWICE SIZE OF PIPE TO BE INSERTED, ONE SLEEVE PER PIPE CONTROL WIRING SLEEVE, 2" SCH. 40 PVC 25R ROTORS WITH MPR NOZZLES HUNTER PGP-04-PRB NOTE: 1. ENTIRE SYSTEM SHALL BE INSTALLED PER TCEQ STANDARDS, MANUFACTURER'S SPECIFICATIONS AND ALL CITY CODES. 2. THIS DESIGN IS DIAGRAMMATIC, ALL PIPING, VALVES, AND OTHER EQUIPMENT SHOWN WITHIN PAVED AREAS OR OUT OF PROPERTY BOUNDARIES ARE FOR DESIGN CLARIFICATION ONLY, AND SHALL BE INSTALLED IN PLANTING AREAS WITHIN THE PROPERTY LINES OR LIMITS INDICATED ON PLAN. THE IRRIGATION CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL ABOVE GROUND IRRIGATION EQUIPMENT WITH THE OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO INSTALLATION, OR IRRIGATION CONTRACTOR MAY BE REQUIRED TO MOVE SUCH ITEMS AT HIS OWN COST. 3. VARIOUS AREAS ON PLAN ARE SHOWING SINGLE HEAD COVERAGE. IF OWNER SHOULD ELECT FOR FULL COVERAGE, CONTRACTOR TO PROCURE THE PROPER PERMITS AND BID ALTERNATE FOR THESE ADDITIONAL SPRAY HEADS, ZONES, AND CONTROLLER EXPANSION FOR THE SYSTEM. 4. IRRIGATION CONTRACTOR IS TO COORDINATE LOCATION AND PLACEMENT OF ALL IRRIGATION ITEMS WITH THE GENERAL CONTRACTOR. CONTRACTOR IS TO USE EXTREME CAUTION IN TRENCHING TO AVOID EXISTING AND PROPOSED UTILITIES. CONTRACTOR TO LOCATE ALL UTILITIES PRIOR TO IRRIGATION INSTALLATION. 5. IRRIGATION SPRAY NOZZLES TO BE ADJUSTED TO AVOID PAVEMENT, BUILDING, WALLS, FENCES, UTILITIES, EQUIPMENT, SIGNAGE, AND CALL BOX 6. REFERENCE LANDSCAPE PLAN FOR LOCATION OF GRAVEL, STEEL EDGING AND ALL PROPOSED PLANT MATERIAL. 7. IN TURF AREAS (BOTH SOD AND HYDROMULCH AREAS) OUTSIDE OF IRRIGATION PERMANENT COVERAGE, CONTRACTOR TO PROVIDE TEMPORARY IRRIGATION UNTIL ESTABLISHED, TYP 8. CONTRACTOR TO TAKE ALL NECESSARY MEASURES TO PREVENT WATER HAMMER AND SYSTEM COLLAPSE BY DISCHARGING AIR DURING STARTUP AND ALLOWING AIR TO ENTER DURING SHUTDOWN. INSTALL THRUST BLOCKS AND AIR/VACUUM RELIEF VALVES AS NECESSARY TO PROTECT MAINLINE SYSTEM. FOR 3 INCH AND LARGER MAINLINE, INSTALL JOINT RESTRAINTS AT TURNS. INSTALL PER MANUFACTURE'S RECOMMENDATIONS. 9. ALL MAINLINE PIPING 3 INCHES AND LARGER SHALL BE BELL AND GASKETED CLASS 200 PVC PIPE, SDR 21. INSTALL PER MANUFACTURERS RECOMMENDATIONS, CONTACT MANUFACTURE OR DISTRIBUTOR FOR PRODUCT DEMONSTRATION. 10. GROUP VALVES IN FIELD AS NECESSARY FOR MAINLINE SIZING. CENTER FEED LATERALS WHEN POSSIBLE. (INSTALL THRUST BLOCKS AND AIR/VACUUM RELIEF VALVES AS NECESSARY TO PROTECT MAINLINE SYSTEM) SUGGESTED LATERAL PIPE SIZE, CLASS 200 PVC FLOW RANGE GPM PIPE SIZE 0 - 8 GPM 3/4" 8 - 12 GPM 1" 12 - 22 GPM 1-1/4 " 22 - 28 GPM 1-1/2" 28 + GPM 2" PATIO PLANTER (WITH MLD DRIPLINE) AND SLEEVE N.T.S. 14 NOTES: 1.COORDINATE PLANTER SLEEVES PRIOR TO FLATWORK INSTALLATION. 2.ZONE PATIO PLANTER SEPARATE FROM OTHER DRIP ZONES. 3.MDL SUPPLY LINE SHOULD LAY FLAT, USE TIE-DOWN STAKES AS NECESSARY. 4.SLEEVE THROUGH CONCRETE SHOULD SET FLUSH. THE SLEEVE SHOULD BE CONCEALED UNDER THE PLANTER AND NOT SEEN AFTER PLANTER INSTALLATION. 5.PROVIDE WATERPROOF SEAL OR CAP AT SLEEVE TO PREVENT WATER IN SLEEVES. PLAN VIEW PLANTER PER LANDSCAPE PLAN, LENGTHS VARY MLD-05-06-BL DRIPLINE USE TIE-DOWN STAKES IF NECESSARY, DRIPLINE SHALL LAY FLAT HUNTER 1/4" BARBED FITTINGS, QB-TEE AND QB-ELB ELBOW TO IRRIGATION HOSE AND RISER WITH THREADED CONNECTION CAP/PLUG END OF MDL DRIPLINE SECTION VIEW PLANTER PER LANDSCAPE PLAN, LENGTHS VARY PLANTS PER LANDSCAPE PLAN ELBOW TO IRRIGATION HOSE WITH THREADED CONNECTION IRRIGATION HOSE, THREADED CONNECTIONS TO SUPPLY TUBING PVC TEE 3" PVC SLEEVETO DRIP ZONE LATERAL OR VALVE TO NEXT PLANTER (IF SHARING SLEEVE ROUTE) TO DRIP ZONE LATERAL, VALVE, OR PREVIOUS PLANTERS (IF SHARING SLEEVE ROUTE) FIRST PLANTER (IF CONNECTION TO SECOND PLANTER) PLANTER/LAST PLANTER CONNECTION (IF SHARING SLEEVE ROUTE) 12" CONCRETE PATIO, PER CIVIL AND ARCHITECTURE PLANS 3" PVC RISER, CUT FLUSH WITH CONCRETE AFTER FLATWORK IS COMPLETE DRILL HOLE IN FIBERGLASS PLANTER TO ALIGN WITH SLEEVE 1/2" SUPPLY TUBING INSIDE SLEEVES PROVIDE WATERPROOF SEAL OR CAP AT SLEEVE TO AVOID WATER IN SLEEVING PVC ELBOW 3" PVC SLEEVE 3" PVC RISER, CUT FLUSH WITH CONCRETE AFTER FLATWORK IS COMPLETE 1/2" SUPPLY TUBING INSIDE SLEEVES PLANTER PER LANDSCAPE PLAN, LENGTHS VARY PLANTS PER LANDSCAPE PLAN ELBOW TO IRRIGATION HOSE WITH THREADED CONNECTION IRRIGATION HOSE, THREADED CONNECTIONS TO SUPPLY TUBING CONCRETE PATIO, PER CIVIL AND ARCHITECTURE PLANS DRILL HOLE IN FIBERGLASS PLANTER TO ALIGN WITH SLEEVE PROVIDE WATERPROOF SEAL OR CAP AT SLEEVE TO AVOID WATER IN SLEEVING Property Lines adjusted to reflect Approved Concept Plan An irrigation permit will be required. Review will take place at the time of permitting. REVISIONSOFNo.DateApp.SHEET NO.© 2024 QuiddityJOB NO.:SCALE:DESIGNED BY.:HTFCHECKED BY:ACHA B C D E F 1234DATE:DRAWN BY:AMAS SHOWNJANUARY 202517007-0146-02Texas Board of Professional Engineers and Land Surveyors Reg. No. F-232904500 Mercantile Plaza Drive, Suite 210 Fort Worth, Texas 76137 682.268.2200 SALAD AND GO - COPPELL - I-635 AND BELT LINESTATE O F TE X A SL I C E NSED I R GI ATORR 23713 CODY S RICHARDSON a W R AWR Designs, LLC P.O. Box 1746 Aledo, Texas 76008 amanda@awr-designs.com c. 512.517.5589 2-19-24 1570 S BELT LINE, COPPELL, TX 750191570 S BELT LINELOT 5, BLOCK AVICTORY AT COPPELL ADDITIONCOPPELL, TX 75019L2.02IRRIGATION SPECIFICATIONS AND DETAILSSECTION 32 8423 - UNDERGROUND IRRIGATION SLEEVES AND UTILITY CONDUITS PART 1 - GENERAL 1.1 DESCRIPTION A.PROVIDE UNDERGROUND IRRIGATION SLEEVES AS INDICATED ON THE DRAWINGS. 1.2 RELATED WORK A.SECTION 32 8424 - IRRIGATION SYSTEM. 1.3 REFERENCE STANDARDS A.AMERICAN STANDARD FOR TESTING AND MATERIALS (ASTM) - LATEST EDITION. PART 2 - MATERIALS 2.1 GENERAL A.POLYVINYL CHLORIDE PIPE (PVC) - SCHEDULE 40 SHALL BE USED FOR ALL SLEEVING PURPOSES. B.PVC PIPES SHALL BE MARKED WITH SDR NUMBER, ASTM STANDARD NUMBER, AND THE NSF SEAL. C.SOLVENT SHALL BE USED AS RECOMMENDED BY MANUFACTURER TO MAKE SOLVENT WELDED JOINTS. PIPE AND FITTINGS SHOULD BE CLEANED BEFORE APPLYING SOLVENT. PART 3 - EXECUTION 3.1 INSTALLATION A. A MINIMUM OF TWENTY FOUR (24) INCHES COVER SHALL BE PROVIDED OVER THE TOP OF SLEEVE FROM FINISH GRADE. B. SLEEVES SHALL BE EXTENDED ONE (1) FOOT PAST THE EDGE OF PAVEMENT OF WALLS. INSTALL A NINETY DEGREE ELBOW ON EACH SLEEVE AND ADD ADDITIONAL LENGTH TO EXTEND ABOVE FINISH GRADE BY TWELVE (12) INCHES. CAP PIPE ENDS. 3.2 BACKFILL A.BACKFILL SHALL BE PLACED OVER SLEEVES IN SIX (6) INCH LIFTS. SOIL SHALL BE TAMPED INTO PLACE, TAKING CARE TO NOT DAMAGE SLEEVE. B.REPAIR ANY DAMAGE FROM IMPROPER COMPACTION. END OF SECTION SECTION 32 8424 - IRRIGATION SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A.PROVIDE A COMPLETE IRRIGATION SYSTEM INSTALLATION AS DETAILED AND SPECIFIED. THIS SHALL INCLUDE FURNISHING ALL LABOR, MATERIAL, EQUIPMENT AND SERVICES NECESSARY TO PROVIDE COMPLETE INSTALLATION. WORK INCLUDES: a. TRENCHING b. BACKFILL c. AUTOMATIC CONTROLLED SYSTEM d. AS BUILT DRAWINGS B.SLEEVING AS SHOWN SHALL BE FURNISHED BY THE GENERAL CONTRACTOR. C.METER AND POWER SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. 1.2 RELATED WORK C.REFERENCE IRRIGATION PLANS FOR CONTROLLER, HEAD AND ALL VALVE LOCATIONS. D.REFERENCE LANDSCAPE PLANS, NOTES, DETAILS FOR ADDITIONAL REQUIREMENTS. E.SECTION 32 9300 - LANDSCAPE F.SECTION 32-8423 - UNDERGROUND IRRIGATION SLEEVE AND UTILITY CONDUITS 1.3 REFERENCE STANDARDS A.AMERICAN STANDARD FOR TESTING AND MATERIALS (ASTM) - LATEST EDITION. 1.4 QUALITY ASSURANCE AND REQUIREMENTS A.PERMITS AND FEES: THE CONTRACTOR SHALL OBTAIN AND PAY FOR ANY PERMITS NECESSARY AND ALL OBSERVATIONS AS REQUIRED. B.MANUFACTURER'S DIRECTIONS: MANUFACTURER'S DIRECTIONS AND DETAILED DRAWINGS SHALL BE FOLLOWED IN ALL CASES WHERE THE MANUFACTURERS OF ARTICLES USED IN THIS CONTRACT FURNISH DIRECTIONS COVERING POINTS NOT SHOWN IN THE DRAWINGS AND SPECIFICATIONS. C.ORDINANCES, CODES, AND REGULATIONS: ALL LOCAL, MUNICIPAL AND STATE LAWS, AND RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS, AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR. ANYTHING CONTAINED IN THESE SPECIFICATIONS SHALL NOT BE CONSTRUED TO CONFLICT WITH ANY OF THE ABOVE RULES AND REGULATIONS AND REQUIREMENTS OF THE SAME. D.HOWEVER, WHEN THESE SPECIFICATIONS AND DRAWINGS CALL FOR OR DESCRIBE MATERIALS, WORKMANSHIP, OR CONSTRUCTION OF A BETTER QUALITY, HIGHER STANDARD OR LARGER SIZE THAN IS REQUIRED BY THE ABOVE RULES AND REGULATIONS, THESE SPECIFICATIONS AND DRAWINGS SHALL TAKE PRECEDENCE. 1.5 SCHEDULE OF MATERIALS A.MATERIALS LIST: a. ALL EQUIPMENT MANUFACTURERS AND MODEL NUMBERS SHALL BE AS NOTED ON THE PLANS. b. THE CONTRACTOR SHALL FURNISH THE ARTICLES, EQUIPMENT, MATERIALS, OR PROCESSES SPECIFIED BY NAME IN THE DRAWINGS AND SPECIFICATIONS. NO SUBSTITUTION WILL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE LANDSCAPE ARCHITECT. c. A COMPLETE MATERIAL LIST OF EQUIPMENT SHALL BE SUBMITTED BEFORE PERFORMING ANY WORK. SUBMITTAL SHOULD INCLUDE ALL MANUFACTURERS' SPECIFICATIONS AND LITERATURE FOR APPROVAL BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. d.EQUIPMENT OR MATERIALS INSTALLED OR FURNISHED WITHOUT PRIOR APPROVAL OF THE LANDSCAPE ARCHITECT MAY BE REJECTED. e. APPROVAL OF ANY ITEM, ALTERNATE OR SUBSTITUTE INDICATES ONLY THAT THE PRODUCT OR PRODUCTS APPARENTLY MEET THE REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS ON THE BASIS OF THE INFORMATION OR SAMPLES SUBMITTED. f.MANUFACTURER'S WARRANTIES SHALL NOT RELIEVE THE CONTRACTOR OF HIS LIABILITY UNDER THE GUARANTEE. SUCH WARRANTIES SHALL ONLY SUPPLEMENT THE GUARANTEE. 1.4 RECORD AND AS BUILT DRAWINGS/SUBMITTALS A.CONTRACTOR SHALL PROVIDE AND KEEP UP TO DATE AND COMPLETE “AS-BUILT” RECORD SET OF PRINTS. B.CONTRACTOR SHOULD USE ALL SYMBOLS AND NOTATIONS CONSISTENT WITH THE ORIGINAL DRAWINGS. C.IN “AS-BUILT” DRAWINGS, CONTRACTOR SHALL LOCATE: a. CONNECTION TO EXISTING WATER LINES b. CONNECTION TO ELECTRICAL POWER c. GATE VALVES d. ROUTING OF SPRINKLER PRESSURE LINES e. SPRINKLER CONTROL VALVES f. QUICK COUPLING VALVES g. OTHER RELATED EQUIPMENT D.SUBMIT COMPLETED TRACINGS PRIOR TO FINAL ACCEPTANCE. DATE AND SIGN ALL DRAWINGS. E.EQUIPMENT TO BE FURNISHED: a. SUPPLY AS PART OF THIS CONTRACT THE FOLLOWING TOOLS: i.QUICK COUPLING KEYS, THREE (3) WITH BOILER DRAINS ATTACHED USING BRASS REDUCER. ii.THREE (3) KEYS FOR EACH AUTOMATIC CONTROLLER b. THE ABOVE MENTIONED EQUIPMENT SHALL BE TURNED OVER TO THE OWNER AT THE CONCLUSION OF THE PROJECT. F. THE IRRIGATION CONTRACTOR SHOULD DEMONSTRATE THAT THE FINAL INSTALLED SYSTEM WILL OPERATE ACCORDING TO THE INTENT OF THE DESIGNED AND SPECIFIED SYSTEM. IRRIGATION CONTRACTOR SHALL GUARANTEE 100% COVERAGE TO ALL AREAS TO BE IRRIGATION. 1.5 MAINTENANCE AND GUARANTEE A.MAINTENANCE AND WORKMANSHIP SHALL BE GUARANTEED FULLY FOR ONE (1) YEAR AFTER FINAL ACCEPTANCE. B.PROVIDE MAINTENANCE OF SYSTEM, CLEANING AND ADJUSTMENT OF THE HEADS, FOR ONE (1) YEAR AFTER COMPLETION OF INSTALLATION. C.GUARANTEE IS LIMITED TO REPAIR AND REPLACEMENT OF DEFECTIVE MATERIALS AND WORKMANSHIP, INCLUDING THE REPAIR OF BACKFILL SETTLEMENT. 1.6 TESTING A.PERFORM TESTING REQUIRED WITH OTHER TRADES INCLUDING EARTHWORK, PAVING, PLUMBING, ETC. TO AVOID CUTTING, PATCHING OR BORING. B.WATER PRESSURE SHOULD BE FOUND PRIOR TO STARTING CONSTRUCTION. DETERMINE/CONFIRM THAT STATIC WATER PRESSURE IS MORE THAN THE WATER PRESSURE NEEDED FOR THE SYSTEM TO FUNCTION PROPERTY. IF STATIC PRESSURE IS LESS THAN THE DESIGN PRESSURE NEEDED, DO NOT START WORK UNTIL THE LANDSCAPE ARCHITECT IS NOTIFIED. 1.7 COORDINATION A.COORDINATE INSTALLATION OF ALL PRODUCTS, INCLUDING EARTHWORK, PAVING AND PLUMBING. B.COORDINATE TO ENSURE THAT ELECTRICAL POWER SOURCE IS IN PLACE. C.COORDINATE INSTALLATION WITH WORK SPECIFIED IN OTHER SECTIONS. D.COORDINATE WITH THE LANDSCAPE CONTRACTOR TO ENSURE PLANT MATERIAL IS UNIFORMLY WATERED IN ACCORDANCE WITH INTENT SHOWN ON DRAWINGS. PART 2 - PRODUCTS 2.1 MATERIALS B.REFER TO CONSTRUCTION DRAWINGS AND NOTES. C.SPRINKLER HEADS IN LAWN AREAS AS SPECIFIED ON PLAN D.PVC PIPE: CLASS 200 SPR 21 E.COPPER TUBING (FOR CITY CONNECTIONS): TYPE “M” F.24V WIRE - SIZE 14, TYPE UF G.ELECTRIC VALVES TO BE ALL PLASTIC CONSTRUCTION AS INDICATED ON PLANS. H.REFER TO DRAWING FOR BACKFLOW PREVENTION LOCATION - COORDINATE EXACT LOCATION WITH THE GENERAL CONTRACTOR. PART 3 - EXECUTION 3.1 INSPECTION: A.SITE CONDITIONS: a.ALL SCALED DIMENSIONS ARE APPROXIMATE. THE CONTRACTOR SHALL CHECK AND VERIFY ALL SIZE DIMENSIONS. b.EXERCISE EXTREME CARE IN EXCAVATING AND WORKING NEAR UTILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES TO UTILITIES WHICH ARE CAUSED BY ANY OF HIS OPERATIONS OR NEGLECT. c.COORDINATE INSTALLATION OF IRRIGATION MATERIALS, INCLUDING PIPE, SO THERE SHALL BE NO INTERFERENCE WITH UTILITIES OR OTHER CONSTRUCTION DIFFICULTY IN PLANTING TREES, SHRUBS, AND GROUNDCOVERS. COORDINATE WORK WITH OTHER SITE CONTRACTORS. 3.2 PREPARATION A.PHYSICAL LAYOUT: a.PIPING AND HEAD LAYOUT AS SHOWN ON PLANS IS SCHEMATIC ONLY. ALL PIPES TO BE INSTALLED DIRECTLY BEHIND CURBS, WALKS AND WALLS WHEREVER POSSIBLE. b.PRIOR TO INSTALLATION CONTRACTOR SHALL STAKE OUT ALL PRESSURE SUPPLY LINES, ROUTING AND LOCATION OF SPRINKLER HEADS. c.ALL LAYOUTS SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT OR OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. B.WATER SUPPLY: a.IRRIGATION SYSTEM SHALL BE CONNECTED TO WATER SUPPLY POINTS OF CONNECTION AS INDICATED ON THE DRAWINGS. b.CONNECTIONS SHOULD BE MADE AT APPROXIMATE LOCATIONS AS SHOWN ON DRAWINGS. CONTRACTOR SHALL VERIFY IN FIELD AND BE RESPONSIBLE FOR MINOR CHANGES CAUSED BY ACTUAL SITE CONDITIONS. 3.3 INSTALLATION A.TRENCHING a.DIG TRENCHES STRAIGHT 6” WIDE WITH NEAR VERTICAL SIDE AND SUPPORT PIPE CONTINUOUSLY ON BOTTOM OF TRENCH. REMOVE LUMBER, RUBBISH, LARGE ROCKS ETC. FROM TRENCHES. LAY PIPE TO AN EVEN GRADE - WITH A FIRM, UNIFORM BEARING FOR ENTIRE LENGTH OF PIPE. b. REMOVE FOREIGN MATTER OR DIRT FROM INSIDE OF PIPE BEFORE WELDING AND KEEP PIPING CLEAN BY ANY MEANS POSSIBLE DURING AND AFTER LAYING OF PIPE. c. PROVIDE A MINIMUM OF EIGHTEEN (18) INCHES OF COVER FOR ALL PRESSURE SUPPLY LINES. d.PROVIDE A MINIMUM OF TWELVE (12) INCHES OF COVER FOR ALL NON-PRESSURE LINES. e. PROVIDE A MINIMUM COVER OF EIGHTEEN (18) INCHES FOR ALL CONTROL WIRING. f. NO MACHINE TRENCHING, UNLESS APPROVED BY THE LANDSCAPE ARCHITECT, SHALL BE DONE WITHIN DRIP LINE OF EXISTING TREES. TRENCHING SHOULD BE DONE BY HAND, TUNNELING OR BORING OR OTHER METHODS APPROVED BY THE LANDSCAPE ARCHITECT. IT SHOULD BE UNDERSTOOD THAT PIPING LAYOUT IS DIAGRAMMATIC AND PIPING SHALL BE ROUTED AROUND TREES AND SHRUBS IN SUCH A MANNER TO AVOID DAMAGE TO PLANTS. B. BACKFILL a. TRENCHES SHALL NOT BE BACKFILLED UNTIL ALL REQUIRED TESTS ARE PERFORMED. TRENCHES SHALL BE CAREFULLY BACKFILLED WITH THE EXCAVATED MATERIALS APPROVED FOR BACKFILLING, CONSISTING OF EARTH, LOAM, SANDY CLAY, SAND OR OTHER APPROVED MATERIALS, FREE FROM LARGE CLODS, STONES OR STICKS. b. IF SETTLEMENT OCCURS AND SUBSEQUENT ADJUSTMENTS IN PIPE, VALVES, SPRINKLER HEADS, LAWN OR PLANTING OR OTHER CONSTRUCTION ARE NECESSARY, THE CONTRACTOR SHALL MAKE ALL REQUIRED ADJUSTMENTS WITHOUT THE COST TO THE OWNER. C. TRENCHING AND BACKFILL UNDER PAVING: a. ALL IRRIGATION MAIN LINE AND LATERAL LINES OR WIRING LOCATED UNDER AREAS WHERE PAVING, ASPHALTIC PAVING, OR CONCRETE SHALL BE INSTALLED IN SCHEDULE 40 PVC SLEEVES OF ADEQUATE SIZE. SEE SECTION 32 8423. D.ASSEMBLIES a. INSTALL ALL ASSEMBLIES SPECIFIED HEREIN IN ACCORDANCE WITH RESPECTIVE DETAILS. IN ABSENCE OF DETAIL DRAWINGS OR SPECIFICATIONS, PERFORM SUCH WORK IN ACCORDANCE WITH BEST STANDARD PRACTICES OR MANUFACTURER'S RECOMMENDATIONS AS APPROVED BY THE LANDSCAPE ARCHITECT. b. MAKE SOLVENT WELDED JOINTS USING ONLY THE SOLVENT RECOMMENDED BY THE MANUFACTURER. PIPES AND FITTINGS SHOULD BE CLEANED OF ALL DIRT AND DUST AND MOISTENED BEFORE APPLYING SOLVENT. c. ON PVC TO METAL CONNECTIONS, THE CONTRACTOR SHALL WORK METAL CONNECTIONS FIRST. USE NON HARDENING PIPE DOPE OR TEFLON TAPE ON THREADED PVC ADAPTERS INTO WHICH PIPE MAY BE WELDED. LIGHT WRENCH PRESSURE IS ALL THAT IS REQUIRED, USE THREADED PVC ADAPTERS INTO WHICH THE PIPE MAY BE WELDED. E. LINE CLEARANCE: ALL LINES SHALL HAVE A MINIMUM CLEARANCE OF SIX (6) INCHES FROM EACH OTHER AND FROM OTHER TRADES. PARALLEL LINES SHALL NOT BE DIRECTLY INSTALLED ONE OVER THE OTHER. F. WIRING: SUPPLY WIRE FROM THE AUTOMATIC CONTROLLER TO ALL THE VALVES. A SEPARATE WIRE IS REQUIRED TO EACH ELECTRIC VALVE. A COMMON NEUTRAL WIRE IS ALSO REQUIRED FROM EACH CONTROL TO EACH OF THE VALVES. BUNDLE MULTIPLE WIRES AND TAPE THEM TOGETHER AT TEN FOOT INTERVALS. EXPANSION COILS OF TEN INCHES SHALL BE INSTALLED APPROXIMATELY EVERY 100 FEET. MAKE ALL SPLICES WATERPROOF. G.AUTOMATIC CONTROLLER: INSTALL AS PER MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS. REMOVE CONTROL VALVES SHALL BE CONNECTED TO CONTROLLER IN NUMERICAL SEQUENCE AS SHOWN ON THE DRAWINGS. EACH REMOVE CONTROL VALVE SHALL BE WIRED TO ONE STATION OF THE CONTROLLER. H.REMOTE CONTROL VALVES: a. INSTALL WHERE SHOWN ON DRAWINGS AND DETAILS. VALVES SHALL BE SIZED ACCORDING TO THE DRAWINGS. b. INSTALL IN A LEVEL POSITION IN ACCORDANCE TO MANUFACTURER'S SPECIFICATIONS. c. WHEN GROUPED TOGETHER, ALLOW AT LEAST TWELVE (12) INCHES BETWEEN VALVES. INSTALL EACH REMOTE CONTROL VALVE IN A SEPARATE VALVE BOX. EACH VALVE NUMBER AND ITS CONTROLLER LETTER SHALL BE STENCILED INSIDE VALVE BOX TOP WITH EXTERIOR PAINT. I. FLUSHING OF SYSTEM: a. AFTER ALL NEW SPRINKLER PIPE LINES AND RISERS ARE IN PLACE AND CONNECTED, ALL NECESSARY WORK HAS BEEN COMPLETED, AND PRIOR TO INSTALLATION OF SPRINKLER HEADS, THE CONTROL VALVES SHALL BE OPENED AND A FULL HEAD OF WATER USED TO FLUSH OUT THE SYSTEM. b. SPRINKLER HEADS SHALL BE INSTALLED ONLY AFTER FLUSHING OF THE SYSTEM HAS BEEN ACCOMPLISHED. J. SPRINKLER HEADS: a. INSTALL HEADS AS DESIGNED ON THE DRAWINGS. MAKE APPROPRIATE ADJUSTMENTS TO HEAD LAYOUT TO ACCOMMODATE FOR ACTUAL FIELD CONDITIONS. b. SPACING OF HEADS SHALL NOT EXCEED THE MAXIMUM INDICATED ON THE DRAWINGS. IN NO CASE SHALL THE SPACING EXCEED THE MAXIMUM RECOMMENDED BY THE MANUFACTURER. c. ALL SPRINKLERS TO ATTACH TO LATERAL LINES WITH FLEXIBLE CONNECTORS. REFERENCE DETAILS ON DRAWINGS. 3.4 TESTING A.THE CONTRACTOR SHALL TEST SPRINKLER MAIN FOR TWELVE TO FOURTEEN HOURS UNDER NORMAL PRESSURE. IF LEAKS ARE PRESENT, REPLACE JOINT OR JOINS AND REPEAT TEST. B. A COMPLETE TEST SHALL BE MADE PRIOR TO BACKFILLING. BACKFILLING MATERIALS MAY BE PLACED IN TRENCHES IN LIFTS TO ENSURE STABILITY OF THE LINE UNDER THE PRESSURE OF BACKFILL. IN EACH CASE, LEAVE FITTINGS AND COUPLINGS OPEN TO VISUALLY INSPECT FOR FULL PERIOD OF TEST. C.WHEN SYSTEM IS COMPLETE, A COVERAGE TEST SHALL BE PERFORMED IN THE PRESENCE OF THE LANDSCAPE ARCHITECT OR OWNER'S REPRESENTATIVE. IT SHALL BE DETERMINED IF THE WATER COVERAGE FOR ALL PLANTING AREAS IS COMPLETE AND ADEQUATE. FURNISH ALL MATERIALS AND PERFORM ALL WORK REQUIRED TO CORRECT ANY INADEQUACIES OF COVERAGE. D.UPON COMPLETION OF EACH PHASE OF WORK, THE ENTIRE SYSTEM SHOULD BE TESTED AND ADJUSTED TO MEET SITE REQUIREMENTS. END OF SECTION NOTES: 1.ALL PVC IRRIGATION SLEEVES TO BE SCHEDULE 40 PIPE. 2.ALL JOINTS TO BE SOLVENT WELDED AND WATERTIGHT. 3.WHERE THERE IS MORE THAN ONE SLEEVE, EXTEND THE SMALLER SLEEVE TO 24-INCHES MINIMUM ABOVE FINISH GRADE. 4.MECHANICALLY TAMP TO 95% PROCTOR. 5.SLEEVE LOCATIONS SHALL BE MARKED ONTO THE TOP OF CURB WITH A SAWCUT OF TWO PARALLEL LINES THAT ARE 2" LONG AND 1" APART. PVC CAP (TYPICAL) 18" 24" MIN. TO FINISH GRADE 18" MIN. DITCH PAVEMENT SLEEVES 4" MIN. CLEARANCE PERMANENT MARKER PAVING PVC CAP (TYPICAL) RUN WIRING BENEATH AND BESIDE MAINLINE. TAPE AND BUNDLE AT 10-FOOT INTERVALS. ALL SOLVENT WELD PLASTIC PIPING TO BE SNAKED IN TRENCH AS SHOWN. TIE A 24-INCH LOOP IN ALL WIRING AT CHANGES OF DIRECTION OF 30° OR GREATER. UNTIE AFTER ALL CONNECTIONS HAVE BEEN MADE. WIRE W/O CONDUIT PLAN VIEW WIRING IN CONDUIT LATERAL PIPE MAINLINE PIPE MAINLINE, LATERAL, AND WIRING IN THE SAME TRENCH SECTION VIEW NOTES: 1. SLEEVE BELOW ALL HARDSCAPE ELEMENTS WITH SCH 40 PVC TWICE THE DIAMETER OF THE PIPE OR WIRE BUNDLE WITHIN. 2. FOR PIPE AND WIRE BURIAL DEPTHS, SEE SPECIFICATIONS. MINIMUM - 12" 3. BACKFILL AND COMPACT TRENCHES TO ORIGINAL GRADE. IRRIGATION PVC SLEEVES PIPE AND WIRING TRENCHING QUICK-COUPLING VALVE: HUNTER MODEL HQ-3RC PRO-C CONTROLLER W/SOLAR SYNC SYSTEM N.T.S. 1.9 CLEARANCE MIN. 1-1/4", 1-1/2" OR 2" CONDUIT FOR VALVE WIRES AS APPROPRIATE BY UNDERWRITERS LABORATORIES 3/4" CONDUIT FOR 120/230 VAC NOTE: 1. WEATHER SENSORS ARE TO BE PROVIDED AS REQUIRED BY LOCAL CODES. VERIFY LOCAL REQUIREMENTS PRIOR TO INSTALLATION. SOLAR SYNC MODULE; MOUNT LESS THAN 6' AWAY FROM CONTROLLER. MODULE CAN BE MOUNTED INTERNALLY WHEN PAIRED WITH THE PCC CONTROLLER. COMPATIBLE HUNTER CONTROLLERS: ICC, PRO-C, PCC NOTE: 1. FURNISH NOMINALLY SIZED BALL VALVE WITHIN SAME BOX AND PRIOR TO MAINLINE TEE. 2. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE. QUICK COUPLING VALVE PLASTIC VALVE BOX WITH PURPLE COVER FINISH GRADE/TOP OF MULCH BALL VALVE PVC SCH 40 ELL PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) BRICK (1 OF 4) PVC MAINLINE PIPE SCH 80 NIPPLE AND SCH 40 ELL PVC SCH 40 TEE OR ELL 3" MIN. 2" x 2" REDWOOD STAKE W/ STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT SUPPORT SYSTEM 3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL WIRE FROM MODULE TO SENSOR SHALL BE 18/2. USE CONTROLLER SMART PORT TO CONNECT TO MODULE UNIT 1 N.T.S. 2 N.T.S. 5 N.T.S. 6 MIN. 1" CLR. MIN. 1" [25MM] CLR. DEPTH PER PLAN DRIP CONTROL ZONE KIT W/ ISOLATION VALVE N.T.S. 8 FINISH GRADE AT ADJACENT SURFACE (TURF OR MULCH) IRRIGATION VALVE BOX: HEAT STAMP LID WITH 'RCV' IN 2" LETTERS HUNTER REMOTE CONTROL VALVE (ICZ) WITH FILTER REGULATORWATERPROOF CONNECTORS (2) 18"-24" COILED WIRE TO CONTROLLER SCH.80 CLOSE NIPPLE, MATCH SIZE TO VALVE SCH.80 CLOSE NIPPLE, MATCH SIZE TO VALVE PVC SLIP X MPT ADAPTOR ISOLATION VALVE PVC SLIP X MPT ADAPTORIRRIGATION LATERAL BRICK SUPPORTS (4) MAINLINE AND FITTINGS FILTER FABRIC - WRAP TWICE AROUND BRICK SUPPORTS 3/4" WASHED GRAVEL - 4" MIN. DEPTH IN-LINE VALVE (ICV) WITH ISOLATION VALVE N.T.S. 4 FINISH GRADE AT ADJACENT SURFACE (TURF OR MULCH) ISOLATION VALVE SCH. 80 CLOSE NIPPLE, SIZE PER RCV IRRIGATION VALVE BOX: HEAT STAMP LID WITH 'RCV' IN 2" LETTERSHUNTER REMOTE CONTROL VALVE (ICV) WITH FLOW CONTROL WATERPROOF CONNECTORS (2) 18"-24" COILED WIRE TO CONTROLLER SCH.80 CLOSE NIPPLE, SIZE PER RCV PVC SLIP X FPT ADAPTOR BRICK SUPPORTS (4) IRRIGATION LATERAL MAINLINE AND FITTINGS FILTER FABRIC - WRAP TWICE AROUND BRICK SUPPORTS 3/4" WASHED GRAVEL - 4" MIN. DEPTH PVC STREET ELL OR MALE BARBED ELBOW LATERAL LINE WITH PVC TEE OR ELL PVC STREET ELL OR MALE BARBED ELBOW PVC FLEX HOSE OR SWING PIPE FINISH GRADE/ TOP OF MULCH SET HEAD FLUSH WITH FINISH GRADE EDGE OF PAVING OR FACE OF WALL 4" MIN. 12" MIN. POP-UP SPRAY BODY OR POP-UP ROTOR MODEL:PROS-04-PRS30 W/ PRO ADJUSTABLE NOZZLES (10a) OR STRIP PATTERN NOZZLES AS INDICATED ON PLAN. * NOTE: 1. MAY NOT BE USED IN LANDSCAPE AREAS LESS THAN FORTY-EIGHT INCHES (48") IN LENGTH OR WIDTH. N.T.S. 7 MP ROTATOR USE PROS-04-PRS40 SPRAY BODY MODEL AND PROS-04-PRS30 FOR SHORT RADIUS, ROTATOR NOZZLES ARE SPECIFIED AS FOLLOWS: MP-800SR = 6' - 12' MP-1000 = 8' - 15' MP-2000 = 13' - 21' MP-3000 = 22' - 30' MP STRIPS MP CORNERS LABELED AS: RXX (WHERE XX = DISTANCE OF THROW) ROTORS USE PGP ULTRA, PGP-04-PRB MODEL W/ MPR-25, -30, OR -35 NOZZELS LABELED AS: XXR HUNTER DRIPLINE CONNECTION W/DRIPLINE AND ELBOW N.T.S. 9 HUNTER DRIPLINE (HDL) PER PLAN PLD OR PLD-LOC FITTING FINISHED GRADE MULCH PER LANDSCAPE PLAN HDL RISER - LENGTH AS REQUIRED PVC SUPPLY HEADER PLD OR PLD-LOC FITTING SOIL ECO INDICATOR- FLEX TUBING N.T.S. 10 ECO INDICATOR FINISHED GRADE ADJACENT MULCH PVC LATERAL PIPE FLEX TUBING TREE BUBBLER ASSEMBLY WITH HUNTER PROS-06-PRS30 N.T.S. 11 SECTION VIEW TREE PER LANDSCAPE PLAN FINISH GRADE OR TOP OF MULCH HUNTER PROS-06-PRS30 (USE NUMBER OF SPRAY BODIES PER PLAN) FLEXIBLE TUBE OR SWING ARM LATERAL FITTING LATERAL PIPE PER PLAN TREE ROOT BALL UNDISTURBED SOIL NOTE: 1. PLACE POP-UP BUBBLER DIRECTLY AT THE EDGE OF THE ROOT BALL. ENSURE THAT THE STREAM BUBBLERS SPRAYS DIRECTLY ONTO THE ROOT BALL TO WET THOROUGHLY. 2. SPACE REQUIRED NUMBER OF SPRAY BODIES EQUIDISTANT AROUND EDGE OF ROOT BALL. 2. USE NUMBER OF SPRAY BODIES PER PLAN. COPPER PIPE FROM POINT-OF-CONNECTION NOTE: 1. INSTALL BACKFLOW PREVENTER AS REQUIRED BY LOCAL CODES AND HEALTH DEPARTMENT. VERIFY LOCAL REQUIREMENTS PRIOR TO INSTALLATION. 2. INSTALL PER MANUFACTURE'S SPECIFICATIONS. 3. INSTALL HUBBELL HOT BOX DROP OVER ENCLOSURE AND POLYMER CONCRETE MOUNTING PAD FOR BACKFLOW DEVICE. PRODUCE LP010026023T. PVC MALE ADAPTER REDUCED PRESSURE BACKFLOW PREVENTER COPPER MALE ADAPTER (1 of 2) COPPER UNION (1 of 2) COPPER 90° ELL (1 of 4) COPPER PIPE (TYPICAL)12" FINISH GRADE IRRIGATION MAINLINE REDUCED PRESSURE ASSEMBLY N.T.S. 3 Property Lines adjusted to reflect Approved Concept Plan An irrigation permit will be required. Review will take place at the time of permitting. THREADED4"THREADED2"2' - 6"TACK WELD NUT DIA. 3/4" AASHTO M314-90 GR.55 STEEL CAN USE EITHER STYLE ANCHOR BOLT PLAN VIEW (2) 3/4" RIGID ELECTRICAL CONDUIT (POWER/LOW VOLTAGE) (4) #4 REBAR X 4'-3" LG. EQUALLY SPACED ON 18" CIRCLE W/(8) #3 TIES: TOP (3) IN 1st 5", (2) ON 6" CENTERS, (3) ON 15" CENTERS NOTE: IF 6000 PSI COMPRESSIVE STRENGTH CONCRETE IS USED, REBAR IS NOT REQUIRED. QTY. CONCRETE: 0.7 CU. YDS. DIA. 2' - 0" CONCRETE 8"8"FRONT ELEVATION WIDTH OF CONCRETE 12"DEPTH CONCRETE4"NOTE:IF 6000 PSI COMPRESSIVE STRENGTH CONCRETE IS USED, REBAR IS NOT REQUIRED. SPEAKER TO BE PLACED BEFORE MENU BOARD 1'-6" MAX.12"LOW VOLTAGE ACCESS ELECTRICAL DISCONNECT (2) 1" RIGID ELECTRICAL CONDUIT (POWER/LOW VOLTAGE) #3 REBAR EQUALLY SPACED ON 6" CENTER HILTI ANCHORS PROVIDED BY HME43"8" PREMANUFACTURED SPEAKER BOX WITH PAINTED BLACK FINISH 5"5"3"70 1/8"12 1/4" LOW VOLTAGE ACCESS ON/OFF SWITCH **LIGHTING ONLY** *DIGITAL SCREEN POWERED DOWN PER SCREEN INSTRUCTIONS* 6 1/4" SIDE VIEW PREMANUFACTURED MENU BOARD WITH PAINTED BLACK FINISH 16"54 1/8"18 1/2" 87 3/8" DIA. OF CONCRETE 2'-0" FRONT ELEVATION NOTE: IF 6000 PSI COMPRESSIVE STRENGTH CONCRETE IS USED, REBAR IS NOT REQUIRED. 88 23/32"12 1/4"PLAN VIEW HME SPEAKER BREAKER PANEL; REF ELECTRICAL DRIVE THRU CONTROLLER (3) 1" RIGID ELECTRICAL CONDUIT (POWER/LOW VOLTAGE) (4) #4 REBAR X 5' - 3" LG. EQUALLY SPACED ON 18" CIRCLE W/ (8) #3 TIES: TOP (3) IN 1st 5", (2) ON 6" CENTERS, (3) ON 15" CENTERS DEPTH OF CONCRETE5'-9"3" CLEAR TYP.CURB, REF: CIVIL TS 5" X 5" X 3/16" ASTM A-500 Gr. B 8"1 3/4"4"18 1/2"12 1/4"8"4 1/2" 7" GENERAL NOTES: 1. REFERENCE STRUCTURAL DRAWINGS FOR FOOTING SIZING AND DETAILS. 2. GC TO FOLLOW MANUFACTURERS WRITTEN INSTRUCTIONS FOR INSTALLATION OF ALL EQUIPMENT, FIXTURES, FURNISHINGS, FINISHES, ETC. 3. GC TO COORDINATE ALL SITE WORK WITH CIVIL DRAWINGS. 4. FINISH TO BE PAINTED BLACK. MATCH SW 6991 BLACK MAGIC. 6" 6,000 PSI CONCRETE CURB, REF CIVIL FOR LOCATION MENU BOARD BASE PLATE SPEAKER, LOCATE BEFORE MENU BOARDS POST MOUNT DRIVE THRU DETECTOR, ALIGN WITH SPEAKER NOTE:ENSURE ADEQUATE SPACE BETWEEN SPEAKER POST AND EDGE OF MENU BOARD SO THAT MENU BOARD IS NOT BLOCKED INSTALL BASE PLATE BOLT PATTERN ROTATED 15 DEG. TOWARD SPEAKER BOX. FIELD VERIFY FINAL PLACEMENT WITH VEHICULAR VIEW ANGLE. COORDINATE WITH SAG CONSTRUCTION PM PRIOR TO FINALIZING LOCATION.4'-0"5'-6"2'-0"2'-0"4'-3"15°34" - 36" 6" - 12" PROJECT INFORMATION CHECKED BY: DRAWN BY: SCALE: ORIGINAL ISSUE: PROJECT NO: SHEET NUMBER SHEET TITLE AS NOTED SEAL 513 MAIN STREET, SUITE 300 FT. WORTH, TX 76102 817.820.0433 www.roguearchitects.com PROTOTYPE VERSION 2.00THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS.3/12/2024 8:42:43 AMAS003I-635 & Belt Line06/01/2023 P. C J. JEFFERY SITE DETAILSCoppell, Texas, 7501924-0039 PERMIT SET: 04/29/2024 1 1/2" = 1'-0"2 ANCHOR BOLT DETAIL 1 1/2" = 1'-0"5 DT MENU BOARD BASE PLATE 1" = 1'-0"3 DT SPEAKER BOX ELEVATION VIEW 3/4" = 1'-0"1 MENU BOARD AND SPEAKER ISLAND 3" = 1'-0"6 DT SPEAKER BOX BASE PLATE 1" = 1'-0"4 DT MENU BOARD SIDE ELEVATION 1" = 1'-0"7 DT MENU BOARD ELEVATION 1 1/2" = 1'-0"8 DT MENU BASE PLATE ISSUE DATE DESCRIPTION ADMINISTRATIVELY APPROVED March 15, 2024 Project is compatible with the Conceptual Plan approved for the overall development and is therefore eligible for administrative approval. GENERAL NOTES: 1. REFERENCE STRUCTURAL DRAWINGS FOR FOOTING SIZING AND DETAILS. 2. GC TO FOLLOW MANUFACTURERS WRITTEN INSTRUCTIONS FOR INSTALLATION OF ALL EQUIPMENT, FIXTURES, FURNISHINGS, FINISHES, ETC. 3. GC TO COORDINATE ALL SITE WORK WITH CIVIL DRAWINGS. 4. FINISH TO BE PAINTED BLACK. MATCH SW 6991 BLACK MAGIC. FINISH GRADE 0'-0" B.O. DT CANOPY 9' - 0" REBAR, REF: STRU HSS 6X6X3/16", REF. A201 FOR LOCATION HAND HOLE FOR FUTURE POWER 1" CONDUIT CLEARANCE 9' - 0" BREAKAWAY BAR HSS 6X6X3/16" REF. A201 FOR LOCATION 7' - 0" 4' - 0"1' - 5" PIVOT PLATE COLLAR 4"SHEAR PIN DEPTH OF CONCRETEREF: STRUDIA. OF CONCRETE REF: STRU 2' - 0"8"8"MIN 1' - 4" BACK OF CURB, REF: CIVIL NOTE: SET ANCHOR BOLTS PARALLEL TO BACK OF CURB CURB, REF: CIVIL 3' - 0"6"MIN2"DEPTH OF CONCRETEREF: STRUDIA. OF CONCRETE REF: STRU 3/4" X 36" GALV. J-BOLT ANCHORS (4) 1" RIGID ELECTRICAL CONDUIT (POWER/LOW VOLTAGE) PROJECT INFORMATION CHECKED BY: DRAWN BY: SCALE: ORIGINAL ISSUE: PROJECT NO: SHEET NUMBER SHEET TITLE AS NOTED SEAL 513 MAIN STREET, SUITE 300 FT. WORTH, TX 76102 817.820.0433 www.roguearchitects.com PROTOTYPE VERSION 2.00THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS.3/7/2024 2:38:57 PMAS004I-635 & Belt Line06/01/2023 P. C J. JEFFERY SITE DETAILSCoppell, Texas, 7501924-0039 PERMIT SET: 04/29/2024 1" = 1'-0"1 DT CLEARANCE BAR 1 1/2" = 1'-0"2 DT CLEARANCE BAR BASE PLATE 1 1/2" = 1'-0"3 DT CLEARANCE BAR BASE PLATE - ELEVATION ISSUE DATE DESCRIPTION ADMINISTRATIVELY APPROVED March 15, 2024 Project is compatible with the Conceptual Plan approved for the overall development and is therefore eligible for administrative approval. AS002 5 9 AS002 4 AS002 3 AS002 2 AS002 1AS002 GATE SWING MIN. 115°, MAX. 120°1/4" FLOOR SLOPECONCRETE SLAB; REF: CIVIL 4' - 0"4' - 0"4' - 0" CONCRETE FOOTING, REF: STRU 6" DIAMETER STL BOLLARD; REF: 8/AS002 (TYP) 6" STL POST PAINTED FLAT BLACK. FASTEN TO FOOTING BELOW (TYP).8"4' - 0"12' - 0"8 1/2"13' - 4" 1' - 4"10' - 8"1' - 4" 6" DIAMETER STL BOLLARD; REF: 8/AS002 (TYP) 12' - 0"4' - 4"11"10' - 2"11" 120°120°16' - 8"12' - 0"10"(510mm)1' - 8"(150mm)6"1 1/2" ANGLE WELDED TO STEEL FRAME 3/4" BAR CANE BOLT CORRUGATED ARCHITECTURAL PANEL SET IN STEEL CHANNEL FRAME PROVIDE HOLES AT CONCRETE FOR BOTH FULLY OPEN AND CLOSED POSITIONS WEEP HOLE GATE TO SWING OPEN MIN. 115°, MAX. 120°6"VARIES3' - 6"FILL PIPE WITH CONCRETE 6" STEEL PIPE, PAINT TO MATCH GATE PAVING OR CONCRETE SLAB EXPANSION JOINT (SEAL) CONCRETE FOOTING; REF: STRUC BASED ON REGIONALREQUIREMENTS. REF: STRU1'-6" ROUNDED CAP SLAB ON GRADE. REF STRU 8" CMU WALL, GROUT SOLID. REINFORCE AND TIE INTO FOOTING/SLAB, REF: STRU.1' - 4" MINADJACENT GRADE1' - 0" MIN BELOW3' - 0" 3" 8" CMU BLOCK WALL, RE: ELEVATION FOR FINISH PAINT AND PRIMER FINISH ON INTERIOR TO MATCH FLAT BLACK ON GATE. ONE COAT OF BLOCK FILLER FOLLOWED BY TWO COATS OF EXTERIOR MASONRY PAINT, FLAT BLACK. T.O. WALL 7' - 6" AFF 1" TYP.3"PREPARED SUBGRADE CONTROL JOINT VERTICAL #5 REBAR, REF. STRU C-1 BOLLARD, REF: 8/AS002 BOLLARD FOOTING; REF: STRU 2" STONE CAP (TYP.) FOUNDATION; REF: STRU GRADE LINE 1' - 0"1' - 4"7' - 6"E-1 16' - 8" C-1 FOUNDATION; REF: STRU BOLLARD FOOTING; REF: STRU. CONCRETE SLAB (2) HEAVY DUTY CANE BOLTS. REF; 7/AS002 GALVANIZED LOCKABLE SLIDE BOLT 18 GA FLUTED STEEL DOORS. 2" STONE CAP (TYP.) BOLLARD, REF: 8/AS0027' - 6"1' - 4"1' - 0"BOLLARD FOOTING; REF: STRU. GRADE LINE GALVANIZED, HEAVY DUTY, SELF-CLOSING GATE HINGES (BOTH SIDES), WELDED TO 6" STL POST 1' - 4"10' - 8"1' - 4" E-1 P-1 P-1 E-1 C-1 C-1 8" CMU WALL 6" DIAMETER GALVANIZED STEEL TUBE POST SET IN CONCRETE FOOTING REF: STRU PAINT TO MATCH GATE. PROVIDE WEEP HOLES IN BETWEEN CORRUGATED METAL CHANNELS 18 GA. FLUTED STEEL SHEET STEEL CHANNEL FRAME. MITER AND WELD CORNERS GALVANIZED HEAVY DUTY GATE HINGE. GATE IN OPEN SWING POSITION ( MIN. 115°, MAX. 120°) 4" PL 1/4"x1 1/2"x0'-4" L4x4x3/8 x 0'-9" WITH (2) 1/2" DIA HSA ON 8" GAGE. LOCATE AT TOP OF POST FULLY GROUT AND REINF END (2) CELLS WITH (1) #5 VERT FULL HEIGHT OF WALL 2" STONE CAP (TYP.) BOLLARD, REF: 8/AS002 BOLLARD FOOTING; REF: STRU. FOUNDATION; REF: STRU GRADE LINE 1' - 0"1' - 4"E-1 C-1 4' - 0"12' - 0" GALVANIZED LOCKABLE SLIDE BOLT 18 GA FLUTED STEEL DOOR GALVANIZED, HEAVY DUTY, SELF-CLOSING GATE HINGES (BOTH SIDES), WELDED TO 6" STL POST 2" STONE CAP (TYP.) FOUNDATION; REF: STRU GRADE LINE 13' - 4"7' - 6"1' - 4"1' - 0"E-1 C-1 TRASH ENCLOUSURE FINISH SCHEDULE MARK MATERIAL DESCRIPTION PRODUCT:CRYVIT CCP-2 FINISH:SAND COLOR:PAINT MATCH SW-6101 SANDS OF TIME E-1 STUCCO C-1 PRODUCT:STONE CAPCAP STONE PROJECT INFORMATION CHECKED BY: DRAWN BY: SCALE: ORIGINAL ISSUE: PROJECT NO: SHEET NUMBER SHEET TITLE AS NOTED SEAL 513 MAIN STREET, SUITE 300 FT. WORTH, TX 76102 817.820.0433 www.roguearchitects.com PROTOTYPE VERSION 2.00THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS.3/12/2024 10:50:20 AMAS002I-635 & Belt Line06/01/2023 P. C J. JEFFERY TRASH ENCLOSURE DETAILS Coppell, Texas, 7501924-0039 PERMIT SET: 04/29/2024 3/8" = 1'-0"6 FLOOR PLAN 1 1/2" = 1'-0"7 SECTION AT CANE BOLT 1" = 1'-0"8 TRASH ENCLOSURE BOLLARD 1" = 1'-0"9 TYPICAL CMU WALL SECTION 3/8" = 1'-0"3 SIDE ELEVATION "A" 3/8" = 1'-0"4 FRONT ELEVATION 1 1/2" = 1'-0"5 GATE HINGE DETAIL 3/8" = 1'-0"1 SIDE ELEVATION "B" 3/8" = 1'-0"2 BACK ELEVATION ISSUE DATE DESCRIPTION ADMINISTRATIVELY APPROVED March 15, 2024 Project is compatible with the Conceptual Plan approved for the overall development and is therefore eligible for administrative approval. FINISHED FLOOR 0'-0" T.O. HIGH PARAPET 20'-2" T.O. LOW PARAPET 18'-2" B.O. CANOPY 9'-6" B.O. AWNING 8'-0" BR-1 S-1S-1 BR-1 BR-2 BR-2 S-1 MT-1 MT-1 MT-1 P-1 P-1P-1 FR FR FR SCONCE TAPE LIGHT AROUND FRAME 4" DEEP SOLID SURFACE SHELF AT DT WINDOW TAPE LIGHT AROUND FRAME ROOF LINE BEYOND TAPE LIGHT UNDER COPING FINISHED FLOOR 0'-0" T.O. HIGH PARAPET 20'-2" B.O. CANOPY 9'-6" BUILDING NUMBERMT-1 BR-2 BR-1 FR FR P-1 FR P-1 SCONCESCONCE TAPE LIGHT UNDER COPING TAPE LIGHT AROUND FRAME 4" DEEP SOLID SURFACE SHELF AT WALK UP WINDOW FINISHED FLOOR 0'-0" T.O. HIGH PARAPET 20'-2" T.O. LOW PARAPET 18'-2" B.O. CANOPY 9'-6" B.O. AWNING 8'-0" MT-1 MT-1 BR-1 BR-2 BR-1 S-1 P-1 P-1 P-1 P-1 FR FR S-1 S-1SCONCE TAPE LIGHT AROUND FRAME 4" DEEP SOLID SURFACE SHELF AT DT WINDOW ROOF LINE BEYOND TAPE LIGHT UNDER COPING ELEC. PANEL WALL PACK EXTERIOR FINISH SCHEDULE MARK MATERIAL DESCRIPTION P-1 PAINT MT-1 METAL COPING FINISH:PREFINISHED METAL COPING BERRIDGE: PREWEATHERED GALVALUME COLOR:SW-7048 URBANE BRONZE PRODUCT:DRYVIT CCP-2 FINISH:SAND COLOR:PAINT MATCH BENJAMIN MOORE OC-17 WHITE DOVE S-1 STUCCO BR-1 MODULAR THIN BRICK PRODUCT:ENDICOT CLAY - KING SIZE TEXTURE:MATTE COLOR:MANGANESE IRONSPOT GROUT:MAPEI BISCUIT 5014 FR FRAME PRODUCT:SNAP FRAME FINISH:STEEL - PREFABRICATED COLOR:MATTE BLACK FINISH:PAINT COLOR:SW-6991 BLACK MAGIC BR-2 MODULAR THIN BRICK PRODUCT:ELGIN BUTLER - GLAZED BRICK - KING SIZE TEXTURE:MATTE COLOR:#7100 POLAR WHITE GROUT:MAPEI BISCUIT 5014 FINISHED FLOOR 0'-0" T.O. HIGH PARAPET 20'-2" T.O. LOW PARAPET 18'-2" B.O. CANOPY 9'-6" B.O. AWNING 8'-0" MT-1 P-1 MT-1 BR-1 BR-1 P-1 MT-1 BR-2 P-1P-1 ELEC. PANEL WALL PACK TAPE LIGHT UNDER COPING SIGNAGE CALCULATION FRONT TOTAL SIGNAGE LINEAR FT OF FACADE DRIVE... MOBILE... REAR 22.61 17.24 17.24 0 24'-7"55'-2"54'-8"17'-9" PROJECT INFORMATION CHECKED BY: DRAWN BY: SCALE: ORIGINAL ISSUE: PROJECT NO: SHEET NUMBER SHEET TITLE AS NOTED SEAL 513 MAIN STREET, SUITE 300 FT. WORTH, TX 76102 817.820.0433 www.roguearchitects.com PROTOTYPE VERSION 2.00THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS.6/21/2024 3:06:22 PMFP001#1472 I-635 & BELT LINE06/21/2024 P. C J. JEFFERY FACADE PLANCOPPELL, TX, 7501924-0039 FACADE PLAN: 06/21/2024 1/4" = 1'-0"1 DRIVE THRU ELEVATION -NORTH 1/4" = 1'-0"2 FRONT ELEVATION -WEST 1/4" = 1'-0"3 MOBILE EXPRESS ELEVATION -SOUTH STUCCO - OC-17 WHITE DOVE 0 0 384 36 288 28 0 0 672 23 THIN BRICK - #7100 POLAR WHITE 301 70 389 37 142 14 172 37 1004 34 THIN BRICK - MANGANESE IRONSPOT 130 30 291 27 582 56 296 63 1299 44 TOTAL (GLAZED/NON-GLAZED DOORS AND WINDOWS) 431 100 1064 100 1012 100 467 100 2975 100 GLAZED DOORS AND WINDOWS 81 19 31 3 15 1 0 0 127 4 NON-GLAZED DOORS AND WINDOWS 0 0 0 0 28 3 45 10 73 3 TOTAL ELEVATION AREA 512 100 1095 100 1055 100 512 100 3174 100 S.F.%S.F.%S.F.%S.F.%S.F.%MATERIAL FRONT DRIVE THRU MOBILE EXPRESS REAR TOTAL MATERIAL CALCULATION 1/4" = 1'-0"4 REAR ELEVATION -EAST RESTAURANT WITH DRIVE-THRU VICTORY COPPELL LOT 1-10, BLOCK A| TR 12 ACS 4.1621PAD SITE 5 | QSR PREPARATION DATE: June 21st, 2024 ENGINEER: QUIDDITY ENGINEERING 4500 MERCENTILE PLAZA DRIVE, SUITE 210 FORT WORTH, TX 76137 682-268-2207 RYAN J. ALCALA, PE OWNER: SALAD AND GO 5555 EAST VAN BUREN STREET PHOENIX, AZ 85008 937-578-3581 NATE DUNNINGTON APPLICANT: OWNER: SALAD AND GO 5555 EAST VAN BUREN STREET PHOENIX, AZ 85008 937-578-3581 NATE DUNNINGTON FACADE PLAN NOTES • THIS FACADE PLAN IS FOR CONCEPTUAL PURPOSES ONLY. ALL BUILDING PLANS REQUIRE REVIEW AND APPROVAL BY DEVELOPMENT SERVICES. • ALL MECHANICAL UNITS SHALL BE SCREENED FROM PUBLIC VIEW AS REQUIRED BY THE ZONING ORDINANCE WHEN PERMITTED, EXPOSED UTILITY BOXES AND CONDUITS SHALL BE PAINTED TO MATCH THE BUILDING • ALL SIGNAGE AREAS AND LOCATIONS ARE SUBJECT TO APPROVAL BY DEVELOPMENT SERVICES • ROOF ACCESS SHALL BE PROVIDED INTERNALLY, UNLESS OTHERWISE PERMITTED BY THE CHIEF BUILDING OFFICIAL 1" = 160'-0"5 KEY SITE PLAN1 0 2'4'8' Scale: 1/4" = 1'-0" ISSUE DATE DESCRIPTION NARRATIVE OF CHANGES * BR-1: MATERIAL UPDATED TO REFLECT "ENDICOT CLAY - KING SIZE - COLOR: MANGANESE IRONSPOT" * BR-2: MATERIAL UPDATED TO REFLECT "ELGIN BUTLER GLAZED - KING SIZE - COLOR: #7100 POLAR WHITE" * S-1: MATERIAL UPDATED TO REFLECT "BENJAMIN MOORE - COLOR: OC-17 WHITE DOVE" * MT-1: MATERIAL UPDATED TO REFLECT "PREFINISHED METAL COPING PRE-FINISHED BY BERRIDGE - COLOR: SW- 7048 URBANE BRONZE" * ELEVATION 3 - NORTH: DOOR PAINT UPDATED TO MATCH STUCCO (S-1) BENJAMIN MOORE OC-17 WHITE DOVE ARCHITECT: ROGUE ARCHITECTS 513 MAIN STREET, STE 300 FORT WORTH, TX 76102 817-820-0433 JOSEPH JEFFERY ADMINISTRATIVELY APPROVED June 26, 2024 FINISH SAMPLESBR-2 DRYVIT CCP-2 OC-17 WHITE DOVE BR-1 ENDICOT CLAY - KING SIZE MATTE - MANGANESE IRONSPOT S-1 MT-1 PAINT SW MATCH 7048 URBANE BRONZE P-1 PAINT SW MATCH 6991 BLACK MAGIC ELGIN BUTLER - GLAZED BRICK MATTE - #7100 POLAR WHITE FR SNAP FRAME | STEEL - PREFABRICATED MATTE BLACK FINISHED FLOOR 0'-0" T.O. HIGH PARAPET 20'-2" T.O. LOW PARAPET 18'-2" B.O. CANOPY 9'-6" B.O. AWNING 8'-0" MT-1 MT-1 BR-1 BR-2 BR-1 S-1 P-1 P-1 P-1 P-1 FR FR S-1 S-1 FINISHED FLOOR 0'-0" T.O. HIGH PARAPET 20'-2" T.O. LOW PARAPET 18'-2" B.O. CANOPY 9'-6" B.O. AWNING 8'-0" MT-1 P-1 MT-1 BR-1 BR-1 P-1 MT-1 BR-2 P-1P-1 FINISHED FLOOR 0'-0" T.O. HIGH PARAPET 20'-2" T.O. LOW PARAPET 18'-2" B.O. CANOPY 9'-6" B.O. AWNING 8'-0" BR-1 S-1S-1 BR-1 BR-2 BR-2 S-1 MT-1 MT-1 MT-1 P-1 P-1P-1 FR FR FR FINISHED FLOOR 0'-0" T.O. HIGH PARAPET 20'-2" B.O. CANOPY 9'-6" MT-1 BR-2 BR-1 FR FR P-1 FR P-1 PROJECT INFORMATION CHECKED BY: DRAWN BY: SCALE: ORIGINAL ISSUE: PROJECT NO: SHEET NUMBER SHEET TITLE AS NOTED SEAL 513 MAIN STREET, SUITE 300 FT. WORTH, TX 76102 817.820.0433 www.roguearchitects.com PROTOTYPE VERSION 2.00THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS.6/21/2024 3:06:29 PMMB-001#1472 I-635 & BELT LINE06/21/2024 PC J. JEFFERY MATERIAL BOARDCOPPELL, TX, 7501924-0039 FACADE PLAN: 06/21/2024 1/4" = 1'-0"3 WALK-UP ELEVATION - NORTH MB 1/4" = 1'-0"4 REAR ELEVATION - WEST MB 1/4" = 1'-0"1 DRIVE THRU ELEVATION - SOUTH MB 1/4" = 1'-0"2 FRONT ELEVATION - EAST ISSUE DATE DESCRIPTION ADMINISTRATIVELY APPROVED June 26, 2024 Page 1 HA Project No. 20008-01 VICTORY SHOPS AT COPPELL Coppell, Texas EXTERIOR MATERIAL LIST FOR RETAIL SHOPS (20079-01, 04/04/23) BRICK (FULL DEPTH) BR-1 Elgin Butler Products for Creative Architecture Glazed Brick / Color: #7100 Polar White / King Size BR-2 Endicott Clay Product Manganese Ironspot / Texture: Velour / Size: King PAINT / STUCCO P-1 / S-1 Benjamin Moore Classic Colors: White Dove Finish: Smooth on Tower Element (Submit for Approval) Finish: Fine Sand on Field Wall (Submit for Approval) P-2 Benjamin Moore Color Preview: 2121-20 Steel Wool P-3 / S-3 Sherwin Williams / SW7069 Iron Ore Finish: Fine Sand (Submit for Approval) METAL ROOFING MR-1 Berridge Manufacturing Company / Color: Preweathered Galvalume METAL COPING MC-1 Berridge Manufacturing Company / Color: Preweathered Galvalume METAL AWNING MA-1 Berridge Manufacturing Company / Color: Preweathered Galvalume PREFINISHED METAL PM-1 Berridge Manufacturing Company Color: Preweathered Galvalume ALUMINUM STOREFRONT SYSTEM AS-1 Black Anodized ARCHITECTURAL WALL PANEL AP-1 Fiber Cement Siding Products Nichiha Illumination Designer Series AWP3030 / Color to Match P-1 Panel Orientation: Horizontal Finish: Satin / Smooth AP-1(Alt.) Fiber Cement Siding Products Nichiha Illumination Designer Series AWP1818 / Cotton Panel Orientation: Horizontal Finish: Satin / Smooth AP-2 Knotwood Powder Coated on Berridge Metal Soffit / Finish: White Ash Materials and colors subject to change based on availability. Substituted color to remain in a similar color palette. S1 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.0 0.0 0.00.00.10.10.20.30.60.80.60.40.30.20.20.20.30.30.30.20.20.20.30.30.20.10.00.00.00.00.00.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.4 0.6 0.7 0.6 0.5 0.5 0.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.6 0.8 0.8 0.6 0.4 0.2 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.4 0.5 0.6 0.6 0.5 0.4 0.4 0.5 0.6 0.8 1.0 0.9 0.8 0.6 0.6 0.8 1.2 1.7 1.5 1.0 0.7 0.4 0.2 0.0 0.0 0.1 0.1 0.2 0.2 0.4 0.6 0.8 1.1 1.2 0.9 0.7 0.6 0.8 1.1 1.6 1.8 1.6 1.2 0.9 0.9 1.4 0.2 3.8 2.9 1.6 0.9 0.5 0.3 0.0 0.1 0.1 0.1 0.2 0.3 0.5 0.8 1.3 2.1 2.5 1.8 1.1 0.9 1.1 1.7 2.6 3.5 2.9 1.8 1.3 1.3 2.1 4.1 5.6 3.5 1.8 1.0 0.6 0.3 0.0 0.1 0.1 0.1 0.2 0.3 0.6 1.0 1.8 3.5 5.0 0.3 1.7 1.4 1.6 2.3 3.9 5.7 4.1 2.2 1.5 1.6 2.2 3.3 3.9 2.8 1.6 0.9 0.5 0.3 0.0 0.1 0.1 0.1 0.2 0.3 0.6 1.1 1.9 3.6 5.2 3.9 2.6 3.0 2.9 3.1 4.2 4.8 3.3 2.1 1.7 1.8 2.1 2.4 2.3 1.8 1.2 0.7 0.4 0.3 0.0 0.1 0.1 0.1 0.2 0.3 0.5 0.9 1.6 2.4 3.2 3.0 3.9 7.6 7.5 7.2 7.7 6.6 1.5 2.5 2.1 2.2 2.6 2.5 1.9 1.4 0.9 0.6 0.4 0.2 0.0 0.1 0.1 0.1 0.2 0.2 0.4 0.7 1.2 1.6 1.9 2.1 3.1 6.4 3.0 3.2 4.2 3.9 0.9 1.4 0.9 0.6 0.4 0.3 0.0 0.1 0.1 0.1 0.1 0.2 0.4 0.6 1.0 1.3 1.4 1.6 3.2 4.3 2.8 3.5 5.7 5.5 3.2 1.9 1.3 0.9 0.5 0.3 0.0 0.0 0.1 0.1 0.2 0.2 0.4 0.7 1.0 1.4 1.6 1.6 2.5 5.7 6.0 5.3 3.3 1.1 0.7 1.4 1.9 2.8 4.1 4.5 3.4 2.6 2.1 1.3 0.7 0.4 0.0 0.0 0.0 0.1 0.1 0.2 0.4 0.7 1.3 2.0 2.3 2.0 1.8 2.6 2.5 2.0 1.3 0.7 0.5 0.7 1.2 1.9 2.5 3.1 3.6 4.5 3.6 1.9 0.8 0.1 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.7 1.5 2.8 3.2 2.3 1.3 1.0 0.9 0.8 0.6 0.4 0.4 0.5 0.8 1.2 1.6 2.2 3.4 5.3 4.2 0.7 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.8 1.5 0.2 0.9 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.5 0.7 1.1 1.5 1.9 0.4 0.2 0.1 0.1 0.0 Calculation Summary Label Units Avg Max Min PROPERTY LINE Fc 0.16 0.8 0.0 SITE Fc 1.23 7.7 0.0 Luminaire Schedule Symbol Qty Label Description Tag Total Watts Mounting Height 4 RAB A17-4T70N - MOD40 S4 283.28 18 1 RAB L A17-4T70N - MOD40+A17-RHS1 S4-HSS 69 18 1 RAB LIGHTINGS SLIM18N W 20.8 10 14 COOPER LIGHTING RECESSED CANOPY LIGHTS D 173.869 10 2 CAMMAN LIGHTING WALL MOUNTED SCONCE WS 36.28 5 1 RAB LIGHTING RECTANGULAR LED SINGLE HEAD POLE MOUNTED LIGHT S1 70.81 18 DD WS DD DD DD DD DE DD W WS DE LOCK-WASHER POLE BASEPLATE LEVELING NUT NEC MIN FINISH GRADE POLE SHAFT ANCHOR BOLTS TO BE PRE- WELDED INTO CAGE BEFORE INSTALLATION IN FOUNDATION. REFER TO MANUFACTURERS INFORMATION FOR BOLT PATTERN FILL VOID/DEPRESSION IN TOP OF FOOTING AND AROUND ANCHOR BOLTS WITH SELF LEVELING SEALANT. FILL SPACE UNDER BASEPLAT AND ABOVE TOP OF FOOTING WITH STAINLESS STEEL WOOL 3/4"x10' DRIVEN GROUND ROD WITH #6 CU GROUND HAND HOLE TOP OF CONDUIT SHALL BE 1" ABOVE BOTTOM OF HAND HOLE. NUT CONDUIT SIZE AS REQUIRED HIGH STRENGTH ANCHOR BOLTS FURNISHED BY POLE MANUFACTURER, EMBEDDED AS REQUIRED TO DEVELOP FULL TENSILE STRENGTH. FILL TOP OF CONDUIT WITH SEALANT TECHFLEX FLEXO WIRE PROTECTION ON ALL EXPOSED CONDUCTORS NOTE: 1. REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ADDITIONAL FOOTING INFORMATION. WASHER & LOCK-WASHER3'-0"15'-0"POLE MOUNTED LIGHT FIXTURE SQUARE STRAIGHT POLE 3' ROUND CONCRETE POLE BASE PROJECT INFORMATION CHECKED BY: DRAWN BY: SCALE: ORIGINAL ISSUE: PROJECT NO: SHEET NUMBER SHEET TITLE AS NOTED SEAL 513 MAIN STREET, SUITE 300 FT. WORTH, TX 76102 817.820.0433 www.roguearchitects.com PROTOTYPE VERSION 2.00 CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS.1/8/2025 11:33:20 AME107I-635 & Belt Line04/19/2024 C.DYE C.MANDUJANO PHOTOMETRIC PLANCoppell, Texas, 7510924-0039 E107 1/16" = 1'-0" 1 PHOTOMETRIC PLAN SITE LIGHT FIXTURE SCHEDULE MARK MANUFACTURER MODEL VOLTAGE REF. NOTE MOUNTING TOTAL WATTS LAMP SIZE REMARKS S1 RAB A17-5T70N UNV 1 POLE 78 LED LED AREA LIGHT, TYPE V SYMMETRICAL DISTRIBUTION (360*), 4000K, 0-10V DIMMING, WET LISTED, BRONZE FINISH. 15'-0" ALUMINUM POLE RAB MODEL # PS4-11-15D2 LIGHT FIXTURE SCHEDULE NOTES Key Name LIGHT FIXTURE NOTES * NOTE: SALAD AND GO HAS A NATIONAL ELECTRICAL AGREEMENT WITH CONSOLIDATED ELECTRICAL DISTRIBUTORS, INC. (CED). THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND INSTALLING THE LED LIGHTING EQUIPMENT, AND SHOULD PURCHASE FROM CED ACCORDINGLY. QUESTIONS CONCERNING QUOTES, PRICING, AND TECHNICAL SPECIFICATIONS SHALL BE DIRECTED TO DAVID RASH, CED NATIONAL ACCOUNTS, VIA EMAIL david.rash@ced.com OR BY TELEPHONE (817) 480-1171 1 VERIFY MOUNTING HEIGHT WITH ARCHITECT AND COORDINATE CORRESPONDING PENDANT MOUNTING HARDWARE LENGTH W ITH FIXTURE MANUFACTURER. 2 EXIT SIGNS. PROVIDE ALL DIRECTIONAL ARROWS. DOUBLE FACEPLATES. OR BLANK FACEPLATES AS REQUIRED TO CLEARLY IDENTIFY PATH OF EGRESS. COORDINATE MOUNTING TYPE WITH REFLECTED. 3 FIXTURE TO HAVE FINISH AS SPECIFIED BY ARCHITECT. 4 PROVIDE ALL MOUNTIING CLIPS, JOINTS, AND ANY OTHER NESSARY APPURTENANCES FOR ROW MOUNTING. 5 COORDINATE MOUNTING LOCATION OF REMOTE POWER SUPPLY WITH ARCHITECT. LOCATE IN ACCESSIBLE SPACE ABOVE 12"AFF. 6 COORDINATE MOUNTING LOCATION OF REMOTE POWER SUPPLY WITH ARCHITECT. LOCATE ON TOP OF REFRIGERATION CASE, NOT VISIBLE FROM BELOW. 7 LOCATE FIXTURE WITHIN MOUNTING CHANNEL LOCATED ABOVE REFRIGERATION CASE. CHANNEL FURNISHED BY OTHERS. 8 LIGHT FIXTURE FURNISHED WITH COOLER AND INSTALLED BY CONTRACTOR. COORDINATE INSTALLATION WITH COOLER MANUFACTURER PRIOR TO ROUGH-IN. E107 N.T.S. 2 TYPICAL AREA SITE LIGHTING POLE FOOTING DETAIL E107 N.T.S. 3 TYPICAL AREA SITE LIGHTING POLE DETAIL ISSUE DATE DESCRIPTION 3 1/10/2025 CONSTRUCTION BULLETIN -A 3 THIS DRAWING IS A DESIGN DEVELOPMENT DOCUMENT. SITE SPECIFIC MODIFICATIONS MADE UNDER THE RESPONSIBLE CHARGE OF THE ARCHITECT AND/OR ENGINEER-OF-RECORD WILL BE REQUIRED PRIOR TO USING THIS DOCUMENT FOR BIDDING, PERMITTING, OR CONSTRUCTION. 102228 E N S LIC E D REENIGNELAPRO F E SSIO NSTATEO S A XETF FIRM REGISTRATION NUMBER: F-24770 PERMIT SET: 01.08.2025 Property Lines adjusted to reflect Approved Concept Plan Review will take place at the time of permitting.