250808_Retail B SITE PLAN.(Admin App)FIRELANE
FIRELANE FIRELANE FIRELANE
FIR
E
L
A
N
E
FIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANE
FIRELANEFIRELANE FIRELANE FIRELANE FIRELANE FIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANE FIRELANE FIRELANE
FIRELANEFIRELANEFIRELANE FIRELANE
FIRELANE
FIRELA
N
E
FIRELANE
EX OHEEX OHEEX OHEEX OHEEX OHEEX OHEEX OHEEX OHEEX OHEEX OHEEX OHEEX OHEEX OHEEX OHEEX OHEONLY14
9
9
9
12
9
10
12
12
7
8FIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANEFIRELANE7
9
7
FIR
E
L
A
N
E
FIRELANEFIRELA
N
EFIRELANET16.0'16.0'16.0'18.0'20.0'
24.0'18.0'38.0'RETAIL / RESTAURANT B
16,780 SF
ZONING: RETAIL
LOT 4, BLOCK A
VICTORY COPPELL
2.24 AC
BELTLINE ROAD(120' ROW, VOL. 4499, PAGE 159, D.R.D.C.T.)SSSSSSSS200 SF PATIO PROP. 8' MASONRY DUMPSTER
ENCLOSURES REFERENCE
ARCHITECTURE PLANS
FIRE LANE
BY OTHERS
FIRE LANE
BY OTHERS
FIRE LANE
BY OTHERS
60' LANDSCAPE
SETBACK
PROP. RISER ROOM
PROP. FIRE
HYDRANT
PROP. FIRE
HYDRANT
(BY OTHERS)
30'' FIRELANE, MUTUAL ACCESS,
PRIVATE DRAINAGE, & UTILITY EASEMENT
24'' FIRELANE, MUTUAL ACCESS, PRIVATE DRAINAGE, & UTILITY EASEMENTPRIVATE 24'' FIRELANE, DRAINAGE, & UTILITY EASEMENTSIDEWALKEASEMENTWATEREASEMENTLOT 7, BLOCK A
VICTORY AT COPPELL
1.46 ACRES
(63,609 SF)
LOT 8, BLOCK A
VICTORY AT COPPELL
2.96 ACRES
(128,930 SF)
LOT 5, BLOCK A
VICTORY AT COPPELL
0.992 ACRES
(43,223 SF)
LOT 3, BLOCK A
VICTORY AY COPPELL
2.173 ACRES
(94,678 SF)
S89°28'21"W'304.66'
N89°28'46"E'235.96'
Δ=14°50'06"
R=150.00',
L=38.84'
CB=N82°02'50"E
CD=38.73'
N89°27'53"E'71.84'
Δ=14°50'06"
R=150.00',
L=38.84'
CB=N82°02'50"E
CD=38.73'S0°31'14"E'373.63'N89°09'11"E'80.00'N0°31'14"W'147.40'18.0'
18.0'20.0'18.0'84.1'18.0'
18.0'9.0'61.9'18.0'30.0'225.5' TO NEAREST DRIVEWAY325.4'9.0'26.8'42.7'205.0'13.8'7.9'9.0'9.0'18.0'24.0'18.0'80.0'17.0'6.0'9.8'24.0'18.0'20.0'18.0'24.0'9.0'5.0'9.0'9.0'9.0'9.0'9.0'9.0'9.0'9.0'R
10'R10 'R25'
PROP. MONUMENT
IN SIGN EASEMENT
13.8'
29.5'FH5.0'R30'R33'
SIDEWALK
BY OTHERS
PROP. BFR
PROP. BFR
500 SF PATIO
40.0'5.0'
PROP. TRANSFORMER PAD
PROP. FDC
FHC3.0
FILENAME: C3.0 SITE PLAN_VIC22022.dwgPLOTTED BY: John GardnerFULL PATH: K:\Jobs\VIC22022_Coppell Retail B\Drawings\03 - ProductionK:\Jobs\VIC22022_Coppell Retail B\Drawings\03 - Production\C3.0 SITE PLAN_VIC22022PLOTTED DATE: 8/8/20252911 TURTLE CREEK
BLVD, STE 700
DALLAS, TX 75219
972-707-9555
SHEET:REV:DATE:DESCRIPTION:LOT 4R, BLOCK ACITY OF COPPELLDALLAS COUNTY, TEXASKIRKMAN ENGINEERING, LLC
5200 STATE HIGHWAY 121
COLLEYVILLE, TX 76034
TEXAS FIRM NO. 15874
JOB NUMBER:
ISSUE DATE:
----
E N G I N E E R I N G
JOHN D. GARDNER
138295
DATE: 07/03/2025
VICTORY COPPELLRETAIL BSITE BENCHMARKS
BM NO. 1 THE SITE BENCHMARK IS AN "X" CUT SET IN THE
CONCRETE PAVEMENT EAST OF THE SITE, BEING
APPROXIMATELY 48 FEET NORTHWEST FROM A
LIGHT POLE EAST OF THE SITE AND BEING
APPROXIMATELY 1000 FEET SOUTHEAST FROM THE
INTERSECTION OF BELTLINE ROAD AND EAST
DIVIDEND DRIVE.
ELEVATION = 530.06' (NAVD '88)
BM NO. 2 THE SITE BENCHMARK IS AN "X" CUT SET ON TOP OF
CONCRETE CURB LOCATED IN THE NORTHERN
INTERIOR OF THE SITE, BEING APPROXIMATELY 27
FEET NORTHWEST FROM THE NORTHWEST CORNER
OF A CONCRETE DRAINAGE STRUCTURE, AND BEING
APPROXIMATELY 400 FEET EAST FROM THE
INTERSECTION OF BELTLINE ROAD AND EAST
DIVIDEND DRIVE.
ELEVATION = 522.72' (NAVD '88)
SITE PLAN
GRAPHIC SCALE
FEET06030
SCALE: 1" = 30'
LAYOUT & DIMENSIONAL CONTROL NOTES:
1.BOUNDARY LINES AND EASEMENT: REFER TO THE FINAL PLAT TO
VERIFY PROPERTY LINES AND EXISTING EASEMENT LOCATIONS.
2.DIMENSION CONTROL: UNLESS NOTED OTHERWISE, ALL PAVING
DIMENSIONS SHOWN ARE TO FACE OF CURB.
3.CURB RADII: UNLESS NOTED OTHERWISE, ALL CURB RADII SHALL
BE 3' AT FACE OF CURB.
4.BUILDING DIMENSIONS: REFERENCE ARCHITECTURAL PLANS FOR
EXACT BUILDING DIMENSIONS.
5.CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
COORDINATES PRIOR TO CONSTRUCTION.
6.ALL COORDINATES ARE U.S. SURVEY FEET, NAD '83 SURFACE.
7.REFER TO SHEET(S) CX.X - X.X FOR SITE DETAILS.
PARKING DATA TABLE
LOT 4
EXISTING ZONING PD-301R3R-HC
PROPOSED ZONING PD-301R5R-HC
PROPOSED USE RETAIL/RESTAURANT
PROPOSED FLOOR AREA BY USE
7,200 SF(RETAIL)
9,580 SF (REST.)
700 SF (PATIO)
PARKING REQUIREMENTS 1 PER 200 SF(RETAIL)
1 PER 100 SF (REST.)
PKG. REQUIRED (RETAIL)7,200 SF / 200 = 36
PKG. REQUIRED (REST.)9,580 SF / 100 = 95.8
PKG. REQUIRED (PATIO)500 SF INCLUDED +
200 SF /100 =2
PKG. SPACES REQUIRED 134 SPACES
PKG. SPACES PROVIDED (SURFACE)134 SPACES
ADA PARKING REQUIRED 5 SPACES (1 VAN)
ADA PARKING PROVIDED 5 SPACES (1 VAN)
PROPOSED BUILDING AREA 16,780 SF
LOT 2.24 AC
PROPOSED LOT COVERAGE 17.81%
PROPOSED FLOOR AREA RATIO 0.178:1
IMPERVIOUS AREA 74,084 SF
BUILDING HEIGHT 34'S BELTLINE RDPROJECT SITE
HACKBERRY DRIVE
RAN
C
H T
R
AILLYNDON B
JOHNSON
FREEWAY
EAST DIVIDEND DRIVE
635
VICINITY MAP
N.T.S.
COPPELL CITY
LIMITS
SITE PLAN
CITY PROJECT NO. PD-301R5R-HC
VICTORY AT COPPELL RETAIL B
VICTORY COPPELL ADDITION
LOT 4, BLOCK A
1.66 ACRES
CITY OF COPPELL, TEXAS
PREPARATION DATE: 11/3/2022
OWNER/APPLICANT
VICTORY REAL ESTATE GROUP
2911 TURTLE CREEK BLVD, SUITE 700
DALLAS, TX 75219
PH: 469-646-6184
EMAIL: BMENDOZA@VG-RE.COM
CONTACT: BOBBY MENDOZA
ENGINEER
KIRKMAN ENGINEERING, LLC
5200 STATE HIGHWAY 121
COLLEYVILLE, TX 76034
PH: 817-488-4960
EMAIL: JOHN.GARDNER@TRUSTKE.COM
CONTACT: JOHN GARDNER, PE
SURVEYOR
BARTON CHAPA SURVEYING
5200 STATE HIGHWAY 121
COLLEYVILLE, TX 76034
PH: 817-864-1957
CONTACT: JACK BARTON, RPLS
LANDSCAPE ARCHITECT
LONDON LANDSCAPES
P.O. BOX 28
COLLINSVILLE, TEXAS 76233
PH: 972-800-0676
EMAIL: AMY_LONDON@
LONDON-LANDSCAPES.NET
CONTACT: AMY LONDON, RLA
NOTE TO CONTRACTOR
1.ALL ROOFTOP MECHANICAL EQUIPMENT SHALL BE
SCREENED.
2.THE CONTRACTOR SHALL FIELD VERIFY THE LOCATION AND
DEPTH OF ALL EXISTING UTILITIES (WHETHER SHOWN ON
PLANS OR NOT) PRIOR TO COMMENCING CONSTRUCTION. IF
FIELD CONDITIONS DIFFER SIGNIFICANTLY FROM LOCATIONS
SHOWN ON THE PLANS, THE CONTRACTOR SHALL CONTACT
THE PROJECT ENGINEER PRIOR TO PROCEEDING WITH
CONSTRUCTION.
FIRE NOTE
FIRE HYDRANT AND FIRE LANE BY OTHERS SHALL BE
CONSTRUCTED PRIOR TO THE BUILDING CONSTRUCTION
EXTENDING ABOVE FOUNDATION.
LEGEND
FIRE LANE STRIPING
EXISTING FIRE LANE
FIRE LANE
6" 3,600 PSI CLASS "C" (28 DAYS)
REIN.CONC. PAVEMENT
W/ No. 4 BARS @ 18" O.C.E.W.
PARKING AREAS
5" 3,600 PSI CLASS "C" (28 DAYS)
REIN.CONC. PAVEMENT
W/ No. 3 BARS @ 18" O.C.E.W.
PROPOSED FIRE HYDRANT
PROPOSED SANITARY MANHOLE
PROPOSED CURB INLET
PROPOSED GRATE INLET
ACCESSIBLE ROUTE
PARKING COUNT
PROPOSED FDC
PROPERTY BOUNDARY
P1 LIGHT POLE
P1_2 LIGHT POLE
FH
FIRELANE
10
SS
Know what's below.
before you dig.Call
R
PD CONDITIONS
1.SETBACKS AS SHOWN
2.LANDSCAPING AS SHOWN
3.PATIOS UNDER 500 SQUARE FEET DO NOT
HAVE AN ADDITIONAL PARKING
REQUIREMENT.
NOTE:
THIS REVISED SITE PLAN IS MODIFYING THE
LOCATION OF THE FIRE RISER ROOM TO OUTSIDE
OF THE BUILDING AND CHANGING THE
DUMPSTER LOCATION ON THE SITE.