1/2/03 DRC comments '1' H I~ . (~ I T Y · 0 F
C-OPP-EL£
Planning Department
255 Parkway Blvd
Coppell, Texas 75019
Phone: 972-304-3678
Fax: 972-304-7092
PROJECT: The Mercantile Addition, Site Plan and Minor Plat
PLANNING DEPARTMENT CONTACT: Andrea Roy
DIRECT DIAL: 972-304-3677
FAX COVER SHEET
DATE: December 26, 2002
PAGES:
TO: Greg Yancey
Cc: Plan Solutions
Dowdy Anderson
FAX: 972-745-0799¢
FAX: 972-373-9001'/
972-931-9538v~
Items Transmitted:
1. Agenda for the January 2, 2003 DRC Meeting
2. DRC Comments
Remarks:
Please revise plats, site plans, landscape plans, and building elevations
based on staff recommendations. Should applicant disagree with staff
comments please provide reasons why staff recommendations should not
be followed when you attend the January 2, 2003 Development Review
Committee (DRC) meeting.
Each applicant will bring two new sets of revised plats and plans to the
January 2, 2003 DRC meeting. Applicants will be asked to show, explain
and defend any revision. A representative of the project is required to
attend the meeting.
Applicant will have till noon Tuesday, January 7th to resubmit twelve (12)
folded copies of revised plans, three (3) reduced paper copies (8 1/2 X 11 )
and JPEG ,TIF OR SIMILAR ELECTRONIC FORMAT of each exhibit to the
Planning Department.
If you have any questions or would like additional information, please contact me at 972-304-
3677or e-mail at aroyC~ci.coppell.tx,us
' COPPELL
ProjectlD:
SPA-02-0025
884 S Denton Tap Rd
CITY OF COPPELL
DRC REPORT
Name:
COPPELL
The Mercantile, Block A, Lot 1 and 2
Project Type:
Application Date:
Case Manager:
Project Description:
Site Plan Approval
12/17/02
Andrea Roy
to allow the development of two office buildings totaling approximately 21,940 square feet on
2.658 acres of property
Agency
Building Inspection
Electric and Gas
Engineering
Fire Administration
1 of 5
Comments
No comments received
Site Plan Acceptable
1. More clearly indicate what is proposed
in phase one and phase two.
2. Show the right-of-way limits and include
a vicinity map on the site plan.
3. Are you proposing to extend the 8"
waterline from the north?
4. Provide water services to the site from a
single tap to the main.
5. The 8" sanitary sewer line is actually a
15" line along the east side of Denton Tap.
6. On the preliminary drainage plan, show
more detail where the 18" and 24" RCP's
become surface drainage. It may be
necessary to build all of the drainage
system with phase one if positive open
drainage cannot be achieved.
7. Label the approach radii for the
driveway to Denton Tap on the site plan.
1. All fire lanes to be platted as
easements.
2. Indicate location of fire lane on north
side of property.
3. Structures to be equipped with an
automatic fire sprinkler system and fire
alarm.
4. Minimum of 30 inside radius and 54 feet
outside radius is required. Minimum width
of fire lane is 24 feet.
No Comments
Site Plan
1. Indicate if Phase II is formally part of this
Date of Action
12/26/02
12/26/02
12/26/02
Reviewed By
Daniel Colman
Teresa Turner
Travis Crump
Parks and Recreation 12/19/02 John Elias
Planning Department 12/23/02 Andrea Roy
' COPPELL
Project ID:
SPA-02-0025
884 S Denton Tap Rd
CITY OF COPPELL
DRC REPORT
Name:
COPPELL
The Mercantile, Block A, Lot 1 and 2
Project Type:
Application Date:
Case Manager:
Project Description
Site Plan Approval
12/17/02
Andrea Roy
to allow the development of two office buildings totaling approximately 21,940 square feet on
2.658 acres of property
Agency
2 of 5
Comments
application or only conceptual at this time.
Additionally, an approved site plan is valid
for two years, which would allow that
amount of time for development of the site
under this plan. If conceptual, please
denote the areas of the site that will be
constructed with Phase I and lighten/shade
the areas that would be constructed in
correlation with Phase I1.
2. Indicate name, address, phone and fax
numbers of applicant on Site Plan Sheet.
3. Eliminate the word "Preliminary" from
Site Plan.
4. Provide one comprehensive Data Table
for both phases in the upper left-hand
corner of the site plan, and include the
proposed building height.
5. Provide a North Arrow.
6. Indicate zoning districts of all properties
surrounding the subject site, including type
of use (ie-Riverside Church of Christ,
vacant, etc.).
7. More clearly delineate the proposed
property lines and show in a traditional
manner.
8. Indicate spacing between driveways
within the subject property.
9. Indicate boundaries of the pavement
that is already in existence (ie-northem
shared drive, etc.).
10. Clearly label all shared access
easements that exist between the subject
property, the adjacent development to the
north and the church.
11. Show dimensions of both Phase I and
Phase II buildings~
12. Ensure that all landscape islands
measure a minimum of 9' in width, with a
minimum area of 150 square-feet. It
appears that the front landscape island in
Date of Action
Reviewed By
· COPPELL
Project ID:
SPA-02-0025
884 S Denton Tap Rd
CITY OF COPPELL
DRC REPORT
Name:
COPPELL
The Mercantile, Block A, Lot 1 and 2
Project Type:
Application Date:
Case Manager:
Project Description:
Site Plan Approval
12/17/02
Andrea Roy
to allow the development of two office buildings totaling approximately 21,940 square feet on
2.658 acres of property
Agency
3 of 5
Comments
Phase I does not meet the minimum and
possibly another one within Phase II of the
development.
13. Correct drafting with regard to the
sidewalk that is directly between the front
row of parking and the building. Once the
sidewalk turns the corner to proceed
around the north side of the building, an
edge of the sidewalk is not shown.
14. Indicate proposed location for
mechanical equipment (ie-meter boxes,
etc.) and how they will be screened.
15. Show location and outline of proposed
monument sign on site plan sheet.
16. Indicate dimensions of the following:
§ Distance from front building line to front
building wall for both Phase I and Phase II.
§ Width of the northernmost shared
driveway.
§ Width of the green open space between
the edge of pavement along the
northernmost drive and the northernmost
building wall in Phase I1.
§ Typical parking space dimension on
each row.
§ Distance from the rear property line to
the rear building wall.
§ Distance from the dumpster enclosure to
both the side and rear property lines.
Elevations/Sign & Dumpster Detail
17. Indicate the manner in which the
monument sign will be illuminated.
18. Indicate the type of attached signage
proposed for the development. While staff
is aware that individual tenants are likely
unknown at this time, it would recommend
that a sign style (color, font, size, and
general placement) be determined and
notes placed on the plan to ensure
Date of Action
Reviewed By
' COPPELL
ProjectlD:
SPA-02-0025
884 S Denton Tap Rd
CITY OF COPPELL
DRC REPORT
Name:
COPPELL
The Mercantile, Block A, Lot 1 and 2
ProjectType:
Application Date:
Case Manager:
Pr~ect Description:
Site Plan Approval
12/17/02
Andrea Roy
to allow the development of two office buildings totaling approximately 21,940 square feet on
2.658 acres of property
Agency
4 of 5
Comments
compliance for all future tenants.
19. Staff questions the size of the
proposed dumpster enclosure. Is a 15' x
11' dumpster area necessary for office
users?
20. Indicate that proposed awnings are
canvas, or a lusterless, non-metal material
that closely resembles canvas.
21. Indicate on both the Phase I & Phase II
elevation sheets, that the west elevation is
the "Front" elevation, or view from Denton
Tap Road.
Landscape Plan
22. Revise all Landscape Calculations to
appropriately indicate the amount of
landscaping provided for Lot 1 and Lot 2
separately. As currently calculated, the
landscape plan is designed as if this were
one lot; however, it is shown to have a
property line separating Phase I and
Phase I1. Each lot must independently
provide the required level of landscaping.
23. Please note that perimeter
landscaping, including the minimum
number of required perimeter trees must
be provided along the south property line
of Phase II and the north property line of
Phase I. Staff estimates that approximately
6 additional trees are required in these
areas to satisfy the Perimeter landscape
requirements.
24. Please note that driveways cutting
through the Perimeter landscape area may
be deducted from the calculations. For
example, the linear feet along the north
property line, north of Phase II, would only
be 260', because both 24' wide drives
should be subtracted from the futl length of
the property line (308-24-24=260
Date of Action
Reviewed By
' COPPELL
Project ID:
SPA-02-0025
884 S Denton Tap Rd
CITY OF COPPELL
DRC REPORT
Name:
COPPELL
The Mercantile, Block A, Lot 1 and 2
Project Type:
Application Date:
Case Manager:
Project Description:
Site Plan Approval
12/17/02
Andrea Roy
to allow the development of two office buildings totaling approximately 21,940 square feet on
2.658 acres of property
Agency
5 of 5
Comments
LF/50=5.2, rounded to 6). This directly
impacts the number of perimeter trees
required and reduces that amount at
almost every property line.
25. Increase line weight of proposed
property line that will run between Phase I
& Phase II to be similar to perimeter
property lines.
26. Indicate dimensions of all property
lines.
27. Relocate the proposed monument sign
outside of the 15' landscape buffer along
Denton Tap Road.
28. Is Turner-Gesek Investments the
current owner or contract purchaser of this
property? If Turner-Gesek Investments is
not the current owner, please indicate the
currant owner on the Plat and provide the
current owner's signature on the Site Plan
application.
Date of Action
Reviewed By