1/2/03 DRC comments '1' H I~ . (~ I T Y · 0 F C-OPP-EL£ Planning Department 255 Parkway Blvd Coppell, Texas 75019 Phone: 972-304-3678 Fax: 972-304-7092 PROJECT: The Mercantile Addition, Site Plan and Minor Plat PLANNING DEPARTMENT CONTACT: Andrea Roy DIRECT DIAL: 972-304-3677 FAX COVER SHEET DATE: December 26, 2002 PAGES: TO: Greg Yancey Cc: Plan Solutions Dowdy Anderson FAX: 972-745-0799¢ FAX: 972-373-9001'/ 972-931-9538v~ Items Transmitted: 1. Agenda for the January 2, 2003 DRC Meeting 2. DRC Comments Remarks: Please revise plats, site plans, landscape plans, and building elevations based on staff recommendations. Should applicant disagree with staff comments please provide reasons why staff recommendations should not be followed when you attend the January 2, 2003 Development Review Committee (DRC) meeting. Each applicant will bring two new sets of revised plats and plans to the January 2, 2003 DRC meeting. Applicants will be asked to show, explain and defend any revision. A representative of the project is required to attend the meeting. Applicant will have till noon Tuesday, January 7th to resubmit twelve (12) folded copies of revised plans, three (3) reduced paper copies (8 1/2 X 11 ) and JPEG ,TIF OR SIMILAR ELECTRONIC FORMAT of each exhibit to the Planning Department. If you have any questions or would like additional information, please contact me at 972-304- 3677or e-mail at aroyC~ci.coppell.tx,us ' COPPELL ProjectlD: SPA-02-0025 884 S Denton Tap Rd CITY OF COPPELL DRC REPORT Name: COPPELL The Mercantile, Block A, Lot 1 and 2 Project Type: Application Date: Case Manager: Project Description: Site Plan Approval 12/17/02 Andrea Roy to allow the development of two office buildings totaling approximately 21,940 square feet on 2.658 acres of property Agency Building Inspection Electric and Gas Engineering Fire Administration 1 of 5 Comments No comments received Site Plan Acceptable 1. More clearly indicate what is proposed in phase one and phase two. 2. Show the right-of-way limits and include a vicinity map on the site plan. 3. Are you proposing to extend the 8" waterline from the north? 4. Provide water services to the site from a single tap to the main. 5. The 8" sanitary sewer line is actually a 15" line along the east side of Denton Tap. 6. On the preliminary drainage plan, show more detail where the 18" and 24" RCP's become surface drainage. It may be necessary to build all of the drainage system with phase one if positive open drainage cannot be achieved. 7. Label the approach radii for the driveway to Denton Tap on the site plan. 1. All fire lanes to be platted as easements. 2. Indicate location of fire lane on north side of property. 3. Structures to be equipped with an automatic fire sprinkler system and fire alarm. 4. Minimum of 30 inside radius and 54 feet outside radius is required. Minimum width of fire lane is 24 feet. No Comments Site Plan 1. Indicate if Phase II is formally part of this Date of Action 12/26/02 12/26/02 12/26/02 Reviewed By Daniel Colman Teresa Turner Travis Crump Parks and Recreation 12/19/02 John Elias Planning Department 12/23/02 Andrea Roy ' COPPELL Project ID: SPA-02-0025 884 S Denton Tap Rd CITY OF COPPELL DRC REPORT Name: COPPELL The Mercantile, Block A, Lot 1 and 2 Project Type: Application Date: Case Manager: Project Description Site Plan Approval 12/17/02 Andrea Roy to allow the development of two office buildings totaling approximately 21,940 square feet on 2.658 acres of property Agency 2 of 5 Comments application or only conceptual at this time. Additionally, an approved site plan is valid for two years, which would allow that amount of time for development of the site under this plan. If conceptual, please denote the areas of the site that will be constructed with Phase I and lighten/shade the areas that would be constructed in correlation with Phase I1. 2. Indicate name, address, phone and fax numbers of applicant on Site Plan Sheet. 3. Eliminate the word "Preliminary" from Site Plan. 4. Provide one comprehensive Data Table for both phases in the upper left-hand corner of the site plan, and include the proposed building height. 5. Provide a North Arrow. 6. Indicate zoning districts of all properties surrounding the subject site, including type of use (ie-Riverside Church of Christ, vacant, etc.). 7. More clearly delineate the proposed property lines and show in a traditional manner. 8. Indicate spacing between driveways within the subject property. 9. Indicate boundaries of the pavement that is already in existence (ie-northem shared drive, etc.). 10. Clearly label all shared access easements that exist between the subject property, the adjacent development to the north and the church. 11. Show dimensions of both Phase I and Phase II buildings~ 12. Ensure that all landscape islands measure a minimum of 9' in width, with a minimum area of 150 square-feet. It appears that the front landscape island in Date of Action Reviewed By · COPPELL Project ID: SPA-02-0025 884 S Denton Tap Rd CITY OF COPPELL DRC REPORT Name: COPPELL The Mercantile, Block A, Lot 1 and 2 Project Type: Application Date: Case Manager: Project Description: Site Plan Approval 12/17/02 Andrea Roy to allow the development of two office buildings totaling approximately 21,940 square feet on 2.658 acres of property Agency 3 of 5 Comments Phase I does not meet the minimum and possibly another one within Phase II of the development. 13. Correct drafting with regard to the sidewalk that is directly between the front row of parking and the building. Once the sidewalk turns the corner to proceed around the north side of the building, an edge of the sidewalk is not shown. 14. Indicate proposed location for mechanical equipment (ie-meter boxes, etc.) and how they will be screened. 15. Show location and outline of proposed monument sign on site plan sheet. 16. Indicate dimensions of the following: § Distance from front building line to front building wall for both Phase I and Phase II. § Width of the northernmost shared driveway. § Width of the green open space between the edge of pavement along the northernmost drive and the northernmost building wall in Phase I1. § Typical parking space dimension on each row. § Distance from the rear property line to the rear building wall. § Distance from the dumpster enclosure to both the side and rear property lines. Elevations/Sign & Dumpster Detail 17. Indicate the manner in which the monument sign will be illuminated. 18. Indicate the type of attached signage proposed for the development. While staff is aware that individual tenants are likely unknown at this time, it would recommend that a sign style (color, font, size, and general placement) be determined and notes placed on the plan to ensure Date of Action Reviewed By ' COPPELL ProjectlD: SPA-02-0025 884 S Denton Tap Rd CITY OF COPPELL DRC REPORT Name: COPPELL The Mercantile, Block A, Lot 1 and 2 ProjectType: Application Date: Case Manager: Pr~ect Description: Site Plan Approval 12/17/02 Andrea Roy to allow the development of two office buildings totaling approximately 21,940 square feet on 2.658 acres of property Agency 4 of 5 Comments compliance for all future tenants. 19. Staff questions the size of the proposed dumpster enclosure. Is a 15' x 11' dumpster area necessary for office users? 20. Indicate that proposed awnings are canvas, or a lusterless, non-metal material that closely resembles canvas. 21. Indicate on both the Phase I & Phase II elevation sheets, that the west elevation is the "Front" elevation, or view from Denton Tap Road. Landscape Plan 22. Revise all Landscape Calculations to appropriately indicate the amount of landscaping provided for Lot 1 and Lot 2 separately. As currently calculated, the landscape plan is designed as if this were one lot; however, it is shown to have a property line separating Phase I and Phase I1. Each lot must independently provide the required level of landscaping. 23. Please note that perimeter landscaping, including the minimum number of required perimeter trees must be provided along the south property line of Phase II and the north property line of Phase I. Staff estimates that approximately 6 additional trees are required in these areas to satisfy the Perimeter landscape requirements. 24. Please note that driveways cutting through the Perimeter landscape area may be deducted from the calculations. For example, the linear feet along the north property line, north of Phase II, would only be 260', because both 24' wide drives should be subtracted from the futl length of the property line (308-24-24=260 Date of Action Reviewed By ' COPPELL Project ID: SPA-02-0025 884 S Denton Tap Rd CITY OF COPPELL DRC REPORT Name: COPPELL The Mercantile, Block A, Lot 1 and 2 Project Type: Application Date: Case Manager: Project Description: Site Plan Approval 12/17/02 Andrea Roy to allow the development of two office buildings totaling approximately 21,940 square feet on 2.658 acres of property Agency 5 of 5 Comments LF/50=5.2, rounded to 6). This directly impacts the number of perimeter trees required and reduces that amount at almost every property line. 25. Increase line weight of proposed property line that will run between Phase I & Phase II to be similar to perimeter property lines. 26. Indicate dimensions of all property lines. 27. Relocate the proposed monument sign outside of the 15' landscape buffer along Denton Tap Road. 28. Is Turner-Gesek Investments the current owner or contract purchaser of this property? If Turner-Gesek Investments is not the current owner, please indicate the currant owner on the Plat and provide the current owner's signature on the Site Plan application. Date of Action Reviewed By