Loading...
DRC commentsCOFFELL Proiect ID SPR-04-0042 Address S Denton Tap Rd CITY OF COPPELL DRC REPORT Project Name Project Type Application Date Case Manager Proiect Description Site Plan Amendment (Revision) 6/16/04 Matt Steer To revise the size and configuration of an office building containing 11,669-square feet CO??ELL The Mercantile Addition, lot 2, Block A, Agency Building Inspection Electric and Gas Engineering 1 of 1 Reviewed By Review Date Comments Greg Jones 6/23/04 No comments. No comments received Ken Griffin 6/24/04 No Comments. Fire Administration Tim Oates 6~23~04 Parks and Recreation Planning Department John Elias 6/23/04 Matt Steer 6/24/04 Comments may be forthcoming during the full engineering review, 1. Fire sprinkler mom shall be directly accessible from an exterior door - not shown on elevation. 2. Knox box required at the fire sprinkler mom, on exterior wall per Ordinance 2002-989. No comments. Detail Site Plan 1. Show all setback lines and properly lines with dimensions. 2. Depict the distance between the drives. 3. Show proposed monument sign location, if one proposed. 4, Show fire hydrant layout. 5. Depict all fire lanes. Show in bold or shaded. Show mutual access easement on north property line, 6. Include existing zoning and proposed use in the site data table. 7. Is the lot area 56,933 or 56,955? Verify which is correct. 8. Add Lot # and Subdivision Name to title block. Landscape Plan 1, Add a landscape island along the east side of the property. 14 parking spaces + trash enclosure exceeds the maximum area allowed without an island. 2. Revise perimeter landscaping to depict the trees along Denton Tap (not Sandy Lake), and correct the "west property line" calculations to show the south property line calculations. 3.1 tree per 40' is required along primary image zones. Revise. Elevations 1. Show any proposed attached sign areas or monument signs with font, color, material and dimensions. DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: The Mercantile Addition~ Lot 2~ Block AT Site Plan Amendment, to revise the size and configuration of an office building containing 11,669- squae feet on 1.3 acres of property located along the east side of Denton Tap Road, north of Belt Line Road, at the request of Greg Yancey, Tumer-Gesek Investments. STAFF REP.: Matt Steer PROJECT ID#SPR-04-004? DRC DA TE: June24, 2004 and July 1, 2004 CONTACT: Kenneth M. Griffin, P.E., Dir. of Engineering~Public Works 972/304-3686 COMMENT STATUS: ~ C FINAL RE?!$E~ No comments. Commeuts may be forthcoming during the full engineering review. JUL - 8 2004