Loading...
Wynnpage/PP-CS 910402 unzicker · schnurbusch · associates · inc. civil engineers · surveyors · planners 8700 sternmons freeway, suite 400 dallas, texas ~'52,~Z' April 2, 1991 (214) 6~4-55oo Ms. Taryon Bowman City of Coppell Planning Department P.O. Box 478 255 Parkway Coppell, Texas 75019 Re: Wynnpage Addition Coppell, Texas Case Number PD-115 90051-0 Dear Ms. Bowman: We have revised the attached exhibits consistent with your comments found in your letter dated March 27, 1991, and per the DRC meeting at your office on March 29, 1991. Please find below an itemized listing of all changes made to this exhibit which should help expedite your final review. The changes to these exhibits are as follows: 1) Ail lots along the West line of this addition shall have an area of no less than 9,000 square feet and Lots 12-13, Block A (South line) shall have an area no less than 8,400 square feet, revising the lot configuration in this manner results in a loss of one lot within this subdivision. 2) The minimum lot width for those lots along the West line (all 9,000 square foot lots) shall have a width of 75 feet along the building line. All other lots within this addition shall have a minimum width of 66 feet along the building line. 3) For all lots within this addition, the following conditions shall be met by the builders: Minimum side yard setback ........... 8 feet Minimum rear yard setback ........... 20 feet Minimum front yard setback .......... 25 feet Minimum size of dwelling ........ 1,850 square feet Minimum height of dwelling ..... ~ story for Lots 11- 24, Block A; all remaining lots shall be 2 story 4) The perimeter of this tract shall have screening walls constructed by the developer with the following materials and minimum height: Entire West property line -- 8 foot wood screening wall South line; Lots 10-14, Block A -- 6 foot mason~ wall South line; Lots 3-9, Block A -- 6 foot wood screening wall East line and Northeast line -- 6 foot masonry wall North line -- no fence required PAUL S. UNZICKER, P.E. DAVID M. SCHNURBUSCH, P.E. PRESIDENT VICE-PRESIDENT Ms. Taryon Bowman April 2, 1991 Page Two 5) 6) A preliminary landscape plan was submitted to the City with our initial submittal. Generally, the landscape plan is preliminary in nature and is subject to change before the Final Plat is submitted for approval. However, it is our intent to provide landscaping around the proposed entry feature into the subdivision and along the South side of the screening wall located along the South line of this tract. Final Engineering Plans will be submitted to the City Engineer along with the Final Plat. All drainage improvements will conform to current City of Coppell Drainage design codes and specifications. All drainage improvements will be within the project vicinity and will not include any extraordinary improvements for existing downstream facilities. If you have any questions regarding changes, additional comments, please feel free to call. or if you have any Sincerely, Kevin R. Kendrick, P.E. Project Manager KRK/bp cc: Ms. Shohree Daneshman, P.E. / City of Coppell