Loading...
Construction notes GENERAL NOTES' CONCRETE AND REINFORCING STEEL NOTES' STRUCTURAL STEEL NOTES' SITE WORK GENERAL NOTES' '~. 8 1. THIS PROPOSAL IS FOR AN UNMANNED TELECOMMUNICATIONS 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI .301, 1. ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE PROdECT 1. THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO ~ FACILITY CONSISTING OF COLOCATING ON AN EXISTING TOWER WITH A ACI 318, ACI 356, ASTM A184, ASTM A185 AND THE PROJECT SPECIFICATIONS AND IN ACCORDANCE WITH ASTM A36 UNLESS OTHERWISE THE START OF CONSTRUCTION. ~, MICROWAVE DISH AND THE PLACEMENT OF OUTDOOR EQUIPMENT SPECIFICATIONS. NOTED. "' CABINET AT THE TOWER BASE. ~ 2. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES ~ 2. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2. ALL WELDING SHALL BE PERFORMED USING E7OXX ELECTRODES AND WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES, ~, 2. THE PROPOSED FACILIIY WILL BE UNMANNED AND DOES NOT 3000 PSI AT 28 DAYS, UNLESS NOTED OTHERWISE. WELDING SHALL CONFORM TO AISC AND AWS DI.1. WHERE FILLET WELD AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL ~ REQUIRE POTABLE WATER OR SEWER SERVICE. SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE d2.4- IN BE RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE ~ 3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 60, THE AISC "MANUAL OF STEEL CONSTRUCTION", 9TH EDITION. PAINTED USED BY THE SUBCONTRACTOR WHEN EXCAVATING OR DRILLING PIERS ~ 5. THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR HUMAN DEFORMED UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL SURFACES SHALL BE TOUCHED UP. AROUND OR NEAR UTILITIES. SUBCONTRACTOR SHALL PROVIDE SAFETY ~ HABITAT. (NO HANDICAP ACCESS IS REQUIRED). CONFORM TO ASTM A 185 WELDED STEEL WIRE FABRIC UNLESS NOTED TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE ~' OTHERWISE. SPLICES SHALL BE CLASS "B' AND ALL HOOKS SHALL BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL D ~ 4. OCCUPANCY IS LIMITEB TO PERIODIC MAINTENANCE AND INSPECTION, STANDARD, UNO. 3 BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (3/4" SAFETY D) TRENCHING & EXCAVATION. ~ APPROXIMATELY 2 TIMES PER MONTH, BY FIBERTOWER TECHNICIANS. ' ~ DIA) AND SHALL HAVE MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. ~ 4. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR 5. ALL SITE WORK SHALL BE AS INDICATED ON THE DRAWINGS AND PROdECT ~ 5. NO NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM THIS REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: g PROPOSAL. SPECIFICATIONS. ~ CONCRETE CAST AGAINST EARTH ........ 5 IN. 4-. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ~ 6. OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT CONCRETE EXPOSED TO EARTH OR WEATHER: ASTM A 307 BOLTS UNLESS NOTED OTHERWISE. 4. IF NECESSARY, RUBBISH, STUMPS DEBRIS, STICKS, STONES AND OTHER ~ REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. -~. PROPOSED. ~ AND LARGER .......................... 2 IN. ,5. CONCRETE EXPANSION ANCHORS AND EPOXY ANCHORS SHALL BE INSTALLED =' AND SMALLER & WWF... 1 1/2 IN. ~ 7. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE ...... IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. SPECIAL 5. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY ~ PERFORMED IN ACCORDANCE WITH THE PROdECT SPECIFICATIONS. CONCRETE NOT EXPOSED TO EARTH OR WEATHER OR NOT INSPECTIONS, REQUIRED BY GOVERNING CODES, SHALL BE PERFORMED IN FROM THE BIS EQUIPMENT AND TOWER AREAS. (. CAST AGAINST THE GROUND: ORDER TO MAINTAIN MANUFACTURER'S MAXIMUM ALLOWABLE LOADS. _o 6. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. ~ 8. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY SLAB AND WALL ........................ 5/4 IN. MANUFACTURER'S MINIMUM CONCRETE EDGE DISTANCE SHALL BE MAINTAINED FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR ~. DAMAGE CAUSED BY THE CONSTRUCTION OPERATION. BEAMS AND COLUMNS ............... 1 1/2 IN. DURING INSTALLATION. EMBANKMENT. o,, 5 A CHAMFER 3/4" SHALL BE PROVIDED AT ALL EXPOSED EDGES OF __. 9. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL ' 7. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH ,~ PERMITS AND INSPECTION REQUIRED FOR CONSTRUCTION. CONCRETE, UNO, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. ._~ STRUCTURAL STEEL NOTES UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. ~ 10. SUBCONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE 6. INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR, SHALL BE PER 8. ALL EXISTING INACTIVE SEWER, WATER, (:;AS, ELECTRIC AND OTHER UTILITIES, : SITE ON A DALLY BASIS. MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED ~' BOLT, DOWEL OR ROD SHALL CONFORM TO MANUFACTURER'S AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH ~~ 11. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE WILL NOT INTERFERE WITH THE EXECUTION OF THE SUBJECT TO THE ~ VISITS AND DRAWINGS PROVIDED BY THE SITE OWNER. DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR ENGINEERING APPROVAL OF ENGINEERING OWNER AND/OR LOCAL UTILITIES. ,~ SUBCONTRACTOR SHALL NOTIFY FLEXTRONICS, INC. OF ANY APPROVAL WHEN DRILLING HOLES IN CONCRETE. EXPANSION BOLTS ' ~' DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH SHALL BE PROVIDED BY RAMSET/REDHEAD OR APPROVED EQUAL. 9 THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT .~_ CONSTRUCTION. ' '~ COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A 'i (~ UNIFORM SLOPE AND STABILIZED TO PREVENT EROSION AS SPECIFIED IN THE C .,_ 12. NO WHITE STROBIC LIGHTS ARE PERMITTED, LIGHTING, IF REQUIRED, CONCRETE AND REINFORCING STEEL NOTES PROJECT SPECIFICATIONS. ~ WILL MEET FAA STANDARDS AND REQUIREMENTS. .~_ ~ 1.3. SUBCONTRACTOR SHALL CALL FOR UNDERGROUND UTILITY MARKOUT 10. SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING ~ PRIOR TO CONSTRUCTION. 1-800-DIG-TESS. CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES -~ FOR EROSION AND SEDIMENT CONTROL. z SITE WORK GENERAL NOTES ~-~ , , © © I Z L.L,I , ~' , '"" '" O.L.A. PROJECT NUMBER, TFLXO016 -! : er ower -':' ............ u~ O'D E A NEW YORK DALLAS DENTON TAP RD/BELTLINE RD '" -'"-' "'"' · ~*'." ~ "..~.~ ~ ~*."' ~ '...",,~ ~o L Y N C H 4230 LBJ Freeway, Suite 625, Dallas, TX 75244 200 E. BELTLINE ROAD o Ol/5O/O3 ISSUED FOR CONSTRUCTION DS JHR SG ~BRADLEYNEiLGLA$$1E ~ · ~"'" ........................... ~ CONSTRUCTION NOTES ,-- ~'~; 9 :" o tel972.239,6100 fax972,239,6102 COPPELL, TEXAS 75019 18~ BERRY, SUITE 4800 ^ O1/16/03jlSSUED FOR REVIEW DS JHR SG ~,.~: 0753 ;'.~.',~ o A B S A T T I $ T A w"ww. oloce.com SAN FRANCISCO, CA 94107 NO. DATE REVISIONS BY CHK APP'D '"~~~.,~,,4,¢ SITE NU.BER I.---b- CONSULTING ENGINEERSscALE: AS SHOWN DESIGNED BY: JHR DRAWN BY: DS '~ DLS0504. C05 0 6 5 TI- ""' 2 22 x 34 "D" SIZE PSC= : :