PD107-CS 881003Revised: 6-17 8,~'''~ ~'"~*MUST RETURN ALL SIX
PAGES OF THIS APPLICATION
CITY OF COPPELL
ZONING APPLICATION
214-462-0022
A: Requesting:..
Change of zoning from
PD-Retail to PD-SF9
Specific Use Permit [ ]
Description & Location of Property:
Survey & Abstract: James W. Anderson Survey, Abstract No. 18
2. Addition Name (if applicable):
3. Lot & Block (if applicable):
4. Total Number of Acres: 3.238
5. Location further described: Northeast quadrant of the intersection of
Coppell Road and Plantation Drive
Zonin ~ted: PD-SF9
Present Zoning Proposed Zoning
Dwelling Floor Area
Classifi- Gross Net* Classifi- Gross Net* Units/Acre (Non-Resid.
cation Area Area cation Acres Acres (Resid. Only) Uses Only)
PD-Retail 3.24 2.62 PD-SF9 3.24 2.62 2.78
*Excludes major & ~econdary thoroughfares.
D. Reason(s) for Zoning Change (please be specific): Local market
perference for residential versus retail ~roperty offerings.
E. Fee:
I (We) hereby certify that the application fee, $ 119.44 , to cover the cost
of this zoning application, has been paid to the City of Coppell on 9/27
19 88. Further, I (We) hereby authorize the City of Coppell and its employees, to
enter upon the premises herein above described at all reasonable times for the
purpose of erecting, maintaining, or removing signs to notify the public of the
pending zoning application and/or public hearing concerning said application. I
(We) release the City of Coppell and its employees from liability for any damages
which may be incurred to my (our) property in the erecting, maintaing, or removal
of said signs.
Date: 10/3/88
Schrickel, Rollins and
Representative: Associates, Inc.
Owners Signature:
Owners Name:
Centex Real Estate
Corporation
Address: 1422 W. Main, Suite #206
Lewisville, Texas 75067
Telephone #: (214) 221-5556
[1]
CITY OF COPPELL~
DEVELOPER'S CHECKLIST
ZONING REQUEST:
Complete all parts of the official zoning application form ............. [ ]
Ce
Do
Pay appropriate filing fee:
1. Zoning - $100 plus $6.00 per acre .................................. [ ]
2. Zoning appeal - $100 plus $5.00 per property owner notified ........ [ ]
3. Land Study - $100 plus $1.00 per acre (for annexations) ............ [ ]
4. Concept Plan - $100 when submitted separately with a zoning request
n/c when submitted with zoning request (for PD requests) ........... [ ]
5. Site-Plan/Mutil-Family - $100 plus $6.00 per unit (PD requests) .... [ ]
6. Site-Plan - Other - $100 (for PD requests) ......................... [ ]
7. Specific Use Permit (SUP) - $200 plus $5.00 per acre ............... [ ]
Submit twenty-two (22) folded prints of the zoning exhibit drawn at a
scale one inch equals 200 feet or larger on sheet 24" X 36" ............ [ ]
Submit twenty-two (22) folded prints of the site plan of the proposed
24" X 36" [ ]
development on sheet size ....................................
Submit one (1) 8½" X 11" print of both the zoning exhibit and site plan[ ]
Prints of the zonin~ exhibit will contain the following information all on
one sheet:
1. "Zoning Exhibit" title ............................................. [ ]
2. Map of property to be zoned and all property located within 200 ft.[ ]
3. Name and address of applicant and/or owner ......................... [ ]
4. Name and address of certified surveyor ............................. [ ]
5. Name and address of person preparing the exhibit ................... [ ]
6. North point, scale and date ........................................ [ ]
7. Accurate location map in the upper right or left hand corner ....... [ ]
8. Survey and abstract with tract designation ......................... [
9. Current and proposed zoning of the site ............................ [
10. Current zoning of property located within 200 ft. of the site ...... [
11. Names of owners of unplatted land within 200 ft. of the property to
be zoned ........................................................... [
12. Location and right-of-way of existing and planned major and secondary
thoroughfares located within or adjacent to the subject property...[
13. Gross and Net acreages of the requested zoning ..................... [
14. Potential number of dwelling units for residential zoning requests.[
15. Potential square footage of building space for commercial, office,
retail, and industrial zoning requests .............................
16. Location of existing right-of-way utility and/or drainage easements[
17. Topography and flood plain designation ............................. [
18. Aircraft Noise Zone designation (if applicable) .................... [
19. Detailed legal description of property ............................. [
This checklist is only a supplement to the current Zoning Ordinance. It is
the applicant's responsibility to review and comply with the requirements of
the current Zoning Ordinance.
[2]
Ge
In all instances where the applicant proposes to modify, delete or add to
any of the standard regulations of a requested zoning district, a
complete and detailed list of the changes shall be submitted .......... [ ]
If the applicant is requesting a "PD" Planned Development District he
must comply with the additional requirements outlined in the Zoning
Ordinance ............................................................. [ ]
The applicant shall place a zoning change sign, provided by the City, in
a highly visible location on the site. The sign must be in position ten
(10) days prior to P & Z consideration and then returned to the City
within twenty-four (24) hours after City Council consideration ........ [ ]
Oe
If the applicant is requesting a Special Use Permit (SUP) he must comply
with the additional requirements outlined in the Zoning Ordinance ..... [ ]
Me
After review by the City staff, the applicant shall make all corrections
requested of him by the Administrative Assistant ...................... [ ]
te
The applicant shall provide a short summary of his track record as a
developer (examples of projects in other communities: handouts, slide
presentation, etc.) ................................................... [ ]
SITE PLAN REQUIREME ~
Prints of the site plan shall contain the following information
all on one 24" x 36" sheet (submit twenty-two (22) folded prints
and three (3) 8½" x 11" reductions [ ]
SITE PLAN MUST SHOW:
1. Property dimensions of the site and approximate distance to
nearest cross street; ................................................. [ ]
me
Ail existing or proposed buildings on the property, existing
structures, fire lane and access easements adjacent to the
property, and access points on and adjacent to the property; .......... [ ]
Be
t
e
Ye
Setbacks and building lines;
Ail existing private and public streets including street widths,
median openings, and left-turn lanes; ................................. [ ]
Proposed areas of dedication, if necessary, including streets,
alleys or easements; .................................................. [ ]
Points of ingress and egress to the property including design and
spacing of driveways; ................................................ [ ]
Parking area including number and layout of spaces, aisle width,
garbage pick-uR location, fire lanes, and types of surface of
fire lanes; ........................................................... [ ]
Se
e
10.
Screening walls and location, type of screening wall, either
living or masonry ..................................................... [
Indicate all area to be landscaped, type of landscaping, and total
square footage of landscaped areas; do not use "tree stamps" .......... [ ]
Ail existin~ services, fire hydrants, water mains, and sewer mains
within the tract and immediately adjacent to it with pipe size and
location indicated .................................................... [ ]
11. Ail proposed water and sanitary sewer pipe lines with sizes
indicated and valves, fire hydrants, manholes, and other
appurtenances or structures shown; .................................... [ ]
12. Ail proposed or existing water and sewer connections, meter loca-
tions, size of meters, with meter and/or detector check valve
vaults indicated; ..................................................... [ ]
13~~ Finished floor elevation of proposed or existing structures on the
site referenced to sea level datum; ................................... [ ]
14. Existing and proposed contours of the tract in intervals of one
foot or less, referenced to sea level datum; ......................... [ ]
15. Proposed or existing on and off-site inlets; culverts or other
drainage structures ................................................... [ ]
[4]
II.
The following information should be submitted as notes on the site plan:
A. Proposed use of the site or buildings .............................. [ ]
B. Lot or tract area .................................................. [ ]
C. S~ze of building (square footage) .................................. [ ]
D. Height of all structures ........................................... [ ]
E. Number of living units, by number of bedrooms, if applicable ....... [ ]
F. Calculation of the parking spaces required and provided ............ [ ]
NOTE:
REVISION OF ANY PORTION OF A SITE PLAN
REQUIRES SUBMISSION OF THE ENTIRE SITE PLAN.
[5]
CONCEPT PLAN REQUIREmenTS
(PD Requests Only)
Prints of the concept plan shall contain the following information all on one 24"
X 36" sheet (submit twenty-two (22) folded prints and three (3) 8½ X 11" prints).
1) The property dimensions of the site, including total acreage and total
square footage of site, and approximate distance to the nearest cross
street.
2) Existing or proposed building sites, on or adjacent to the property.
3) Existing public or private streets with right-of-way and pavement width,
median openings, and left turn lanes.
4) Proposed areas of dedication, if necessary, including streets, alleys,
easements, and their dimensions.
5) Points of ingress and egress including width of driveways and distance
between driveways.
6) Existing or proposed driveways adjacent to or across the street from the
property, with widths.
7) Proposed median breaks and distance between median breaks, including
left-turn stacking space and transition distances.
8) Parking areas. Parking aisles should be shown (detailing individual
spaces is preferred, but not necessary), as well as any proposed parking
decks.
9) Height of all buildings and structures in feet and stories.
10) Proposed lot coverage, including total square footage proposed in
project.
11) Topography at five (5) foot contours or less.
12) Any required or proposed screening.
ZONING APPLICATION
PZAGN
[6]