PD188-DR000629 UN 2 9 2000 lU Ul _ _~'--" ! ENGINEERING COM --- ITEM: S-1179 and PD 188, HO-C, zoning change request from HO-C and HO-C S- 1125R to PD HO-C, S.U.P. (Planned Development Historic Overlay Commercial, Special Use Permit), for a Restaurant with a Private Club, and the expansion of a free standing beauty shop on approximately 1.27 acres of property located along Coppell Road, approximately 200 feet south of Cooper Lane, at the request of Tom Cravens. DRC DATE: June 29, 2000 and July 6, 2000 CONTACT: Mike Martin, P.E., Assistant City Engineer (972-304-3679) COMMENT STATUS: ,,"PRELIMINARY The overall site construction plans (drainage, grading, utilities) must be designed by a professional engineer. The preliminary drainage plan needs to show the 100-year storm event rUnoff and contour information. Also the proposed drainage areas need to be delineated the amount of runoff from each drainage area and how it will be collected. If there is not an adequate drainage system to collect the increase runoff then it may be necessary to construct an offsite drainage system and/or a detention pond. The proposed storm pipe under the new driveway must be sized to handle the 100-year storm event. The minimum size pipe allowed is 18". Water, wastewater, and roadway impact fees will be required for proposed improvements. Will the proposed onsite curbs be concrete? On the utility plans show fire hydrant locations. Fire hydrant locations must be approved by the Fire Marshal.