Loading...
PD185-CS000510 Coppell, Texas 75019 The City With A Beautiful Future 972-462-0022 ~__~ P.O BOX 478 COPPELL. TEXAS 75019 Ma), 10, 2000 Mr. James Stewart Champion Partners 15601 Dallas Parkway, Suite 100 Addison, TX 75001 RE: PD- 185, Coooell Industrial Addition Dear Mr. Stewart: This letter is to inform you that Case No. PD-185, Coppell Industrial Addition, a zoning change request from LI (Light Industrial) to PD-LI (Planned Development, Light Industrial) to allow a phased development of 2 office/warehouse facilities totaling 1,900,000 square feet of space on approximately 100 acres of property, located along the north side of W. Bethel Road and 50' east of N. Royal Lane, was approved by the Coppell City Council on Tuesday, May 9, 2000, subject to the following conditions: 1) Parking for industrial area shall be one parking space for 5,000 square feet. 2) One monument sign not to exceed 125 square feet shall be allowed. 3) All rooftop mechanical equipment shall be screened from view, subject to approval from the Fire Marshal (see attached memo from the Fire Marshal dated April 21, 2000). 4) Compliance with Department Comments (see attachments). In order to prepare an Ordinance, we need to assemble appropriate documentation. When this has been completed and Council has approved the Ordinance, a copy will be sent to you. As a reminder, the Zoning Change sign can now be returned to the Planning Department for your deposit reimbursement of $100. If you have any questions, please contact me at (972) 304-3675. f~,erely,/. ~icreCt C~afv ~ a~ei'inn~ :ddt, Ct~mzidttY2 ~rV(~uC:;ana file Building Inspection TO: Marcie Diamond, Assistant Planning Director FROM: Travis Cramp, Deputy Fire Chief/Fire Marshal~__~ SL?BJECT: Parapet Walls This memorandum is to follow up our conversation last night, April 20, 2000 concerning requiring parapet walls on the Champion project. Given the width of the buildings (approximately 500 feet), the peak of the buildings will be approximately six feet higher than the exterior walls. Both of these buildings will have an ESFR fire sprinkler system which requires a mechanical smoke/heat removal system. By code, these exhaust fans will be required to be placed on the roof of the building. On buildings this size, between 80 and 90 fans will be required. In order to screen these fans from public view as stated in your staff.comments, a parapet wall would need to be over six feet tall along the full length of the building. This height presents a serious safety problem for firefighters. While the height would present access problems, the primary concern would be egress from the roof for firefighters. The parapets, as required by Planning Staff, would prevent firefighters from safely exiting the mol, possibly trapping the firefighters on the roof. It is the Fire Departments recommendation that the wording of the staffcomments be modified to state that "HVAC units shall be screened from public view on the North and South ends of the buildings". This re- wording will effectively screen the larger air conditioning units from view and still leave the sides of the structures open for safe access by the Fire Department. If you need additional information or would like to discuss this fiather, please contact me at extension 3503. Xc: Robert ICruse, Fire Chief DE VEL OPMENT RE VIEW COMMITTEE ENGINEERING COMMENTS ITEM: PD-185. Coppell Industrial Addition. a toning change request from LI (Light Industrial) to PD-LI (Planned Development, Light Industrial), to allow a phased development of 2 office/warehouse facilities totaling 1,900,000 square feet of space on approximately 100 acres of property located along the north side of I4'. Bethel Road and 50' east of N. Royal Lane, at the request of Champion Partners. DRC DATE: March 30, 2000 and April 6, 2000 CONTACT: Mike Martin, P.E., Assistant City Engineer (972-304-3679) COMMENT..qTA TUS: PRELIMINARY REVISED AFTER P&Z 1. There is a concern about park traffic using the proposed maia North-South drive as a cut- thru from Creek-view to Bethel Road. '~, APR 12 2000 · ,-~ LEISURE SERVICES ¢OM3~T$ III J YAt~ 3 0 2000 DRC DA~: ~r~ ~, 2~ CO~A~: Br~ ~ Park P~tng a~ ~~pe Manger COMMENT STA Tll$: PRELIM1NARY_.~ FINAL REVI~ED ~R P~Z I ~ tree sur~ey indicate~ 1,169u of protected trees will be removed a~ a result of development, with 0" preseroe,t A landscaping credit of $$5" wilt be allowed due to replanting of the site. Further reparation for 584# of removed trees is required. This amounts to a payment of $58,400 to be paid to the Coppetl Reforestation and Naturalization Fund.. DRCO33000f