Loading...
Coppell YMCA/PP-DR 971030 (2)DEVELOPMENT REVIEW ENGINEERING OCT 3 I 1997 DRC DATE: CONTA CT: Coppell Famibt Y.M.C.A. Lot 1, Block 1, Preliminar~ Plat, to arrow the development of a private fitness center with a indoor gymnasium, swimming pool, weight room and cMldeare fad_n_figs on $.$66 acres of property, located at the southwest comer of Town Center Boulevard and Town Center Drive, at the request of Dowdey, Anderson & Assoc. Inc. October 30, 1997 and November 6, 1997 Mike Martin, P.E., Assistant City Engineer (304-3679) COMMENT STATUS: ./'PRELIMINARY Site Plan: 1. Aligning the northern driveway with the existing Comerica access easement could be a long term mistake. Should look at taking access at the north side of the property. This could possibly be a joint access with the City. Preliminary Water, Sanitary Sewer & Drainage Plan: 1. The proposed 8" water line along the north and east side should be a private water line. Also, this line should be looped. 2. The proposed 39" RCP needs to be connected to the existing drainage north of the development.