Coppell YMCA/PP-DR 971030 (2)DEVELOPMENT REVIEW
ENGINEERING
OCT 3 I 1997
DRC DATE:
CONTA CT:
Coppell Famibt Y.M.C.A. Lot 1, Block 1, Preliminar~ Plat, to arrow
the development of a private fitness center with a indoor gymnasium,
swimming pool, weight room and cMldeare fad_n_figs on $.$66 acres
of property, located at the southwest comer of Town Center
Boulevard and Town Center Drive, at the request of Dowdey,
Anderson & Assoc. Inc.
October 30, 1997 and November 6, 1997
Mike Martin, P.E., Assistant City Engineer (304-3679)
COMMENT STATUS: ./'PRELIMINARY
Site Plan:
1. Aligning the northern driveway with the existing Comerica access easement could be a long
term mistake. Should look at taking access at the north side of the property. This could
possibly be a joint access with the City.
Preliminary Water, Sanitary Sewer & Drainage Plan:
1. The proposed 8" water line along the north and east side should be a private water line.
Also, this line should be looped.
2. The proposed 39" RCP needs to be connected to the existing drainage north of the
development.