Loading...
Deer Run/PP-AG 980512 (2)AGENDA REQUEST FORM CITY COUNCIL MEETING: ITEM CAPTION: Ma 12, 1998 ITEM # Consider approval of the Deer Run, PreliminarLv Plat, to allow the development of 56 duplex lots on approximately 9 acres of property located at the northwest corner of Ruby and Coppell Roads. APPROVED BY SUBMITTED BY~Ga~ CITYCOUNCIL TITLE: Direc~-t-d~of Planning and Community Services STAFF RECOMMENDS: DENIAL STAFF COMMENTS: Date of P&Z Meeting: April 16, 1998 Decision of P&Z Commission: Approved (upon advice of legal counsel 7-0) with Commissioners Nesbit, Stewart, Kittrell, Lowry, McCaffrey, Turner and DeFilippo voting in favor. None opposed. Approval subject to the following recommended Engineering comments: !) School should bc pro;'?-cd. (CONDITION MET) o~ (CONDITION MET) FIN. REVIEW:~ CITY MANAGER REVIEW: ,/ Document Name: ®deerun.pp CASE: CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT DEER RUN, PRELIMINARY PLAT P & Z HEARING DATE: C.C. HEARING DATE: April 16, 1998 May 12, 1998 LOCATION: Northwest corner of Ruby and Coppell Roads. SIZE OF AREA: Approximately 9 acres (28 duplex lots/56 dwelling units). CURRENT ZONING: 2F-9 (Two Family-9). REQUEST: Preliminary Plat approval. APPLICANT: Developer: Princeton Realty Corp. 7612 Inwood Rd, Ste 400 Dallas TX 75209 214-357-6988 Fax 214-357-6987 Engineer: Harrington Engineering, Inc. 3023 Routh St Dallas TX 75201 214-720-6011 Fax 214-720-6091 HISTORY: The 2F-9 district has existed on the property since prior to 1984. There is no previous platting history. TRANSPORTATION: South Coppell Road is shown on the thoroughfare plan as a C2U two-lane undivided concrete curb-and-gutter collector within a 60'- wide right-of-way, but currently it is a 2-lane asphalt road without curb and gutter contained within a 60'-wide right of way. Similarly, Ruby road is shown on the thoroughfare plan as a C2U two-lane undivided concrete curb-and-gutter collector within a 60'- wide right-of-way, but currently it is a 2-lane asphalt road without curb and gutter contained within a 40'-wide right of way. SURROUNDING LAND USE & ZONING: North- South - East - West - Golden Triangle Mobile Home Park; 2F-9 Vacant; LI Shadow Ridge Estates; PD-SF-7 Single-family home, Oak Park Village Mobile Home Park; 2F-9 Item # 8 COMPREHENSIVE PLAN: The Comprehensive Plan shows the property as suitable for medium density residential uses. DISCUSSION: During Development Review Committee discussions, a fire code issue became the focus of much attention. It deserves mention, but it is not part of the Subdivision Ordinance and therefore has no bearing on whether or not this plat is approvable. The issue is the requirement of a fire sprinkler system on all residential construction except for detached single-family houses under 10,000 square feet in area. The regulation applies to this project. It also applies to Mansions on the Lake, Stoneleigh at Riverchase and the Archon Apartments, all of which have been platted recently. It is no more an issue for platting purposes than the City's prohibition of untreated wood shingle roofs, 80% masonry requirement or regulation of the use of aluminum wiring. What is at issue is whether or not the plat complies with the Subdivision Ordinance. With the exception of any items noted in the attached Engineering Comments, the plat complies with technical requirements as stipulated therein. However, the ordinance also states that the arrangement of streets shall be considered in relation to topographical conditions and the uses of land to be served by them. Furthermore, the ordinance requires a tree survey. Since it would make no sense whatsoever to require a survey if there were no intention to make use of it in the arrangement of streets, alleys, building lots and open spaces, the planning staff believes that trees were intended to be considered important elements of the topographical conditions. While the street and lot layout presented in this submission is a highly efficient land plan, yielding 6 dwelling units per acre, it is not highly sensitive to tree preservation. Of the 19 post oaks over 20" in caliper on the property, this plan will require the removal of 13, or 68%. These include two beautifully low-spreading trees along the Coppell Road frontage. These trees could be saved, but not without reducing the lot yield. The planning staff estimates a loss of 4 dwelling units to save both 30" post oaks, and a loss of up to 8 dwelling units to save a majority of the larger trees on the site. An 8-unit reduction would change the yield from 6 units per acre to 5.15 units per acre. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: The planning staff recommends revision of the plat to preserve all trees shown on the tree survey over 24" in caliper and a majority of the trees on the property over 20" in caliper. This is likely to Item # 8 require a major redesign. Therefore, the most appropriate action would be to disapprove the plat so that revisions can go back to the Development Review Committee. ALTERNATIVES: 1) Recommend approval of the request 2) Recommend disapproval of the request 3) Recommend modification of the request ATTACHMENTS: 1) Preliminary Plat 2) Preliminary Water & Sewer Layout 3) Preliminary Drainage Plan 4) Tree Survey 5) Screenwall, Landscape & Irrigation Plans (3 sheets) 6) Departmental Comments Item # 8 DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Deer Run. Prelimina~. Plat, to allow the development of 54 duplex lots and 3 triplex lots on approximately 9 acres of property, located at the northwest corner of Ruby and Coppell Roads, at the request of Harrington Engineering, Inc. DRC D.4TE: March 26, 1998 and April 2, 1998 CONT,4CT: Mike Martin, P.E., Assistant City Engineer (304-3679) COMMENT STATUS: .D r., ~'r -~.~-.,~. .. ._.. ~ rn~trnr a r~v F4NA/= ,/REVISED AFTER P & Z 1. No comments.