Loading...
Fairway Drive/FP-CS 880328 GINN, INC. CONSULTING ENGINEERS DEVELOPMENT REVIEW COMMITTEE ENGINEERING DEPARTMENT Staff Comments Date 3 Reviewed By Fairway Drive (NDM - Riverchase) Final Plat - show proposed street easement at railroad; list any variances requested on plat (see comments below) Construction Plans Sheet 2-4: Old existing Fairway Drive - what does City want done with old brick paver crosswalks existing in Riverchase Drive? Street grades at the Belt Line Road intersection need revised due to County re-alignment of Belt Line Road centerline (see plan attached). Need variance for temporary cul-de-sac on Fairway Drive at railroad since distance exceeds 600'. Sheet 3-4: Belt Line Road pavement centerline shifts 10' South per redesign by County (ie., North parkway width now 29.5' to back/curb and South parkway is 9.5'). Sheet 4-4: Sanitary sewer manhole in conflict with proposed inlet. Sanitary sewer in Fairway Drive needed. Include drainage area map. Hydraulic grade line add to storm sewer. If you should have any questions re__garding the above mentioned comments, please contact ~Vt~~~1; , at ~-~. 17103 Preston Road · Suite 100 · LB 118 · Dallas. Texas 75248 · Phone 214/248-4900