Loading...
Highland Mdw/PP-CS 840820GINN, INC. CONSULTING ENGINEERS TO: FROM: DATE: SUBJECT: Mark Sweeney Coppell, Texas GINN, INC., City Engineer August 20, 1984 Highland Meadow Preliminary Plat We have completed the review on the above referenced project and recommend it be presented to the Planning and Zoning Commission for review. As a prelimi- nary plat, it is in general conformance with the subdivision ordinance with the following exceptions: 1. Easements shown for the sanitary sewer, water and storm sewer is not reflected on the actual preliminary plat itself. 2. R.O.W. dedication on Sandy Lake Raod needs to be 25', not 20' in width. 3. The conflict with the R.O.W. at Sandy Lake Road and Highland Meadow Circle must be resolved on the final plat. 4. Provide a 10' easement for the 8" sanitary sewer from the Southeast corner of the property to the existing sanitary sewer manhole. 5. Need a description of the property and survey abstract number. 6. Show 30" Dallas Water Transmission Line along Sandy Lake Road. These items must be resolved prior to being placed on the council agenda for consideration as a preliminary plat. If you have any further questions, please contact Kevin Peiffer at 386-6611. KP/HWG/sr cc: Threadgill-Dowdey and Associates 16135 Preston Road · Suite 106 · Dallas, Texas 75248 · Phone 214/386-6611