Highland Oaks/PP-CS 850314 (2)GINN, INC.
CONSULTING ENGINEERS
March 14, 1985
Mr. Barton Treece, P.E.
TREECE AND COMPANY
14850 Montfort Drive, Suite 171
Dallas, Texas 75240
Re:
Highland Oaks
Preliminary Plat
Coppell, Texas
Dear Mr. Treece:
This is to advise you that the above plat has been reviewed
and passed on to the Coppell Planning and Zoning Commission
for consideration. Please note that the City of Coppell has
approved a streetscape plan which will affect the final plat
and plans, since Sandy Lake Road has been designated a
primary city image zone. Please address this at the final
plat stage.
Sincerely,
GINN, INC.
. Wankum, P.E.
/sr
cc: Ron Ragland
16135 Preston Road · Suite 106 · Dallas, Texas 75248 · Phone 214/386-6611
GINN, INC.
March 12, 1985
CONSULTING ENGINEERS
Mr. Barton Treece, P.E.
TREECE AND COMPANY
14850 Montfort Drive, Suite 171
Dallas, Texas 75240
Re:
Highland Oaks
Final Plat and Construction Plans
Coppell, Texas
Dear Mr. Treece:
This firm has reviewed the above referenced plat and plans
and are recommending that the final plat be placed on the
upcoming Planning and Zoning Commission agenda. Prior to
placement on the City Council agenda, the following points
need to be addressed:
Provide details of landscaping and entrance features per
City Streetscape Plan. the screening wall adjoining
Highland Meadow Circle may be omitted.
2o
Provide reference to standard details and specifications
relevant to project.
3. Provide compacted subgrade to 92% of standard density.
Please provide storm sewer in Sandy knoll Drive.
Sheeting of drainage onto Sandy Lake Road will not be
permitted.
5o
Please take necessary provisions to insure additional
run-off will not occur on property to the west.
The curve 3 for sanitary sewer appears too sharp.
eliminate.
Please
o
Elimination of horizontal curves for water lines is
recommended.
0
Distance from clean-out to nearest manhole should not
exceed 150'.
Sincerely,
o~hn V. Wankum, P.E.
/st
cc:
Ron Ragland
16135 Preston Road · Suite 106 · Dallas, Texas 75248 · Phone 214/386-6611
Date: 3-12-85
Rev. No: 0
DEVELOPMENT IMPACT ANALYSIS
Highland Oaks
ae
Be
General
1. Development Name and size: Highland Oaks, 4.63 ac. 22 lots
2. Owner: Jackson & Morgan - Carrollton
3. Engineer: Treece & Company
4. Current zoning: SF
5. Current status of development: Preliminary plat
6. Location: South of Sandy Lake Road, 1/4 mile west of Moore Road
7. Proposed density: 4.75 lots/acre
8. Annexation or land study required: Not required
9. Issues resolved:
10. Issues to be resolved: Water connection point
11. Dedications required: Sandy Lake Road
Impact
1. Traffic:
a. Off-site collector streets:
b. Off-site arterial streets:
2. Sewer:
a. Proposed mains: 8" main
b. Proposed connections to existing mains:
3. Water: 8" main - connect at Sandy Lake road
4. Drainage or Flow: Minor
5. Schools:
a. Primary school: 12 students
b. Middle school: 6 students
None
Sandy Lake Road - 160 VPD
At Sandy Lake Road
C. Approvals and Fees
1. Fees:
Item
Preliminary Plat
Final Plat
Construction Permit Fee
Water Availability Fee
Sewer Availability Fee
Parks
Fees Required
(when required)
$ 188.00
940.00
4,746.00
11,000.00
11,000.00
3,300.00
2. Assessments and Pro Rata Charges:
ae
Item: Sandy Lake Road - 278.64' x $75/ft. = $20,898.00
Summary:
b. Item:
Summary:
Approvals
a. Annexation
b. Land study: P&Z, City Council
c. Zoning: P&Z, City Council
d. Preliminary Plat:
City Engineer:
Planning & Zoning:
City Council:
e. Final Plat
City Manager:
City Engineer:
Planning & Zoning:
City Council
f. Construction Plans:
City Manager:
City Engineer:
g. File approved plat:
h. Letter of acceptance:
i. Receive as-builts:
j. End of warranty period:
N/R
N/R
N/R