Loading...
Kiddin Aroun/MP-DR 990826 (3)DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Kiddin' Around, Minor Plat, to allow the development of a 2,950 square feet day care facility on 1.12 acres of property located approximately 312' west of Denton Tap Road; along the north side of Parkway Boulevard, at the request of Dowdey, Anderson and Associates, Inc. DRC DA TE: August 26, 1999 and September 2, 1999 CONTACT: Mike Martin, P.E., Assistant City Engineer (972-304-3679) COMMENT STA TU..q: ,'"PRELIMINARY 2. 3. 4. Revise the floodplain limit note. There is no FIRM dated January 25, 1995. Refer to the existing panel # and date then reference the LOMR. Provide a 20' drainage easement for the proposed/existing storm drain located on the property. Consider locating the storm drain pipe next to the existing system along the east side of the property. The water meters need to be located in the R.O.W. or in an easement adjacent to the R.O.W.