Loading...
Magnolia Park/PP-CS 951213ISABELLE MORO P.O. Box 478 Coppell, Texas 75019 214-462-0022 December 13, 1995 Coppell 200 LV. 101 W. Rennet Road,//170 Richardson, TX 75082 RE: Mn?nolla Park. Preliminary Plat Dear Madam/Sir: This letter is to inform you that your request for approval of Magnolia Park, Preliminary Plat, located west of Denton Tap Road, north of Denton Creek, was approved by the Coppell City Council on Tuesday, December 12, 1995. The following conditions apply: (1) (2) 0) (4) (5) Provide a restriction or clarification regarding the fencing of the rear line of Lot 7, Block B; provide building lines with 15' setbacks on standard comer lots, however, where staff deems lots to be key lots, double-front setbacks will be required; an alley along the north side of Lot 47, Block E, needs to be provided; a park plan needs to be provided with the Final Plat; work with staff regarding the access to the property to the west regarding time line and use, and observe the following Engineering comments: · Consideration of additional access from the alley to the street between Lots 19 & 41, Block E. · Provision of a metes and bounds description of all common areas on the final plat. · As per the Subdivision Ordinance, the minimum street right-of-way for a residential street is 50 feet. Therefore, a variance should be requested to the Subdivision Ordinance on the face of the plat. · The location of the entrance roadway into the development is shown to be in the floodplain. This needs to be addressed through either a flood study to remove it from the floodplain or by filling the roadway area and removing an equal amount of fill from the site. Any improvements placed in the floodplain of the proposed park land will require a flood study. Contact the Engineering Department concerning this issue and about the configuration. · There is a concern regarding the ingress and egress to this development which may require some or all of the following items: acceleration lane; deceleration lane; widening of Denton Tap Road to provide a left turn lane into the development; and a traffic signal. The acceleration and deceleration lane will require the dedication of an additional twelve (12) feet of fight-of-way along Denton Tap Road. The installation of the sewer system needs to be coordinated with Centex, formerly Vista Properties, in regards to the location of the sewer, line proposed to go through this development. The proposed water and sewer lines extended to the west property line between lots 7 & 8, Block E should be sized to adequately handle the off- site area and have a minimum of 9 feet separation. Please contact the Engineering Department regarding the radius proposed for the sanitary sewer lines. Regarding//5 above, please be aware that a note needs to be placed on the face of the Plat which basically states ~vehicular access will be provided to the property to the west if a use allowed in Single Family zoning is constructed and only if said use is constructed~. If you have any question, please call me at (214) 304-3678. L. Sieb, A.I.C.P. :tor of Planning & Community Services Bill Anderson, Dowdey, Anderson & Associates, Inc. Isabelle Moro, P&Z Coordinator Building Inspection