Northpoint/SP,PP-CS001013~0/15/00 08:48 FAX 2147397086 HALFF ASSOCIATES ~001/002 · ,- Halff Associates, Inc lllB ' ENGINEERS · ARCHITECTS · SCIENTISTS · PLANNERS · SURVEYORS 8616 Northwest Plaza Drive Dallas, Texas 75225-4292 (214) 346-6200 Fax (214) 739-7086 MEMORANDUM TO: AllAffendees FROM: Chris Amarante Emaih camarante@halff,com DATE: October 13, 2000 AVO: 19123 PROJECT: 121 @ Northpoint SUBJECT: Cib./of Coppell meeting 10/04/00 This memo concerning development of the site located at SH 121 and Northpoint. Below are the items discussed: Attendees: Andrea Roy - City of Coppell fax 972-304-7092 Marcie Diamond - City of Coppell fax 972.304-7092 Mike Martin - City of Coppell fax 972-304-3570 Greg Jones - City of Coppell fax 972-304-3570 Jess Pettit - Jackson Shaw fax 972-628-7444 Chri'.~ Gardner - Jackson Shaw fax 972-628-7444 Scotl McCrary - Gromatzky Dupree & Associates fax 214-871-9869 Daw; Littleton - Halff Associates, Inc. Chris Amarante - Halff Associates, Inc, 1. Zoning LI (Light Industrial) 2. Setbacks 60' front, 10' back and sides 3. Possible 4' dock high on building 3. Li~ngth of the dock based on square footage of building or zoning. 4. The ditch along Northpoint drive will be covered. 5. We need to coordinate with Travis Crump (Fire Marshall) regarding the fire hydrant locations and fire lanes. Travis will also let us know about the pressures in the water lines. The possible need for pressure reducing devise was raised by Jackson Shaw Company, 6. Inter-local agreement may be needed for: trash pickup, fire service(first response), police, building inspection and post office, 7, Benchmarks - we may need to make a formula to convert between the two cities. 8. Det[~ctor checks will be required for each connection to the public water main. 9, Drive spacing for the Northpoint drives will be 120' for 40 mph. 10. We will need to add the following note for sidewalks on the plat; "4 foot wide sidewalks will be con,,~tructed by the property owner when directed by the city engineer". 11. TxDot Contact - determine 12. Drainage detention should not be needed, only if the existing system will not handle the runoff. 13. Ea.~.ement will be needed for offsite drainage, if any. 14. Impact fees - office (3.99)*(SF/1000)*$300 warehouse (1.06)*(SF/1000)*$300 15. Impact fees for water and sanitary sewer based on size of meters. 16. Fee for detector checks is a fiat fee of $1125 50/13/00 08:49 FAX 2147397086 HALFF ASSOCIATES ~002/002 Bum · " Halff Associates, Inc. ENGINEERS · ARCHITECTS ' SCIENTISTS ' PLANNERS ' SURVEYORS 86'16 Northwest Plaza Drive Dallas, Texas 75225-4292 (214) 346-6200 Fax (214) 739-7086 17. The plat must be filed for permits to be issued. 18. An early grading permit can be obtained once the prat and site plan have been sent through P&Z. The conditions for an early permit for grading are: P&Z must have no major changes, a hold harmless letter submitted, and a 2% fee paid. 19. Preliminary plat and site plan duration 120 days. 20. Current codes used by the City of Coppell: 1994 UBC, 1994 Mechanical, 1991 Plumbing, 1993 National Electric, 1994 Fire. The 2000 IBC may be adopted this fiscal year. 21. A tree survey will be required to locate trees with a diameter of 6" or greater. 22. Kimly-Horn is designer of future Fellowship Church c..0nstruction.