Park Place/PP-DR 891031 (2) CITY OF COPPELL
PUBLIC WORKS
WATER UTILITIES DIVISION
~RELIMI/~~AN REQUIREMENTS
DRC Date:
Review of
By: Howard Pafford, Water Foreman, Phone 462-8495
Water/Sanitary Sewer Plan
Please make the following additions and/or corrections,
as marked:
l) -
Show existing water lines in adjacent areas.
2)
Show proposed water lines. (Minimum water line
size 8 ")
3)
4)
Show proposed valve and hydrant placement -
(valves - 500 ft. separation/hydrants
residential areas - 500 ft. separation and
Commercial/Industrial 300 ft. separation).
Note on plans - Estimated daily sanitary sewer
flow
- Estimated daily water demand
5) - Show existing sanitary sewer lines.
6)
Show proposed sanitary sewer lines. (minimum
line size 8") (Lines are required to be
Straight with no curves).
7)
Show proposed manhole and clean out placement
(manholes maximum 500 ft. separation and clean
outs at a maximum of 250 ft. from manholes).
8)
Ail necessary easements should have a 20 ft.
width unless centered on the property lines of
two lots, then 25 ft. will be allowed.
Page 1/2
^PAGE 20~ 2
/
9) ~/ All above comments must be addressed, prior to
staff's recommendation for approval of the
~/ preliminary plat and plans.
10) Provide a written response on all comments,
with explanations provided on items not
addressed as requested above.
11) ~ No comment.
DRC / COMMENTS/WAT / P R! :L I M !
Page 2/2