Loading...
Park W CC(17)/Re-CS 901107GINN, INC. CONSULTING ENGINEERS November 7, 1990 Ms. Shohre Daneshmand, P.E. city of Coppell P.O. Box 478 Coppell, TX 75019 Re: Park West Commerce Center Replat - Blocks 7 and 8 Dear Ms. Daneshmand: We have reviewed the above referenced plans for general conformance to the City of Coppell ordinances and standards. The following sets forth our comments. The plans indicate Enterprise Drive to be constructed from Airline Drive, south, to Wrangler Drive. This is contrary to what was discussed at November 1, 1990 DRC meeting, but we agree with city Staff that the entire road should be constructed at this time. Include Coppell's applicable standard detail sheets in plans, as needed. Provide engineer's seal/signature on plans. For drainage, provide drainage area calculations, assumptions and drainage design criteria. On drainage Line "H", provide more detail of outfall, rip rap, and headwall. Provide dimensions for 2-66" pipes. On Line "H", profile is shown 2-66" RCP and also 7'x5' box culvert. Please clarify· Show sanitary sewer and waterlines on profile of storm drainage lines, especially where in conflict. Please identify if Line "G" is part of these plans. Where Line "H" - 60" RCP is in conflict with 10" sanitary sewer, please address what will be done. The sewer line located in top of storm drain pipe is not acceptable. 17103 Preston Road · Suite 100 · LB 118 · Dallas, Texas 75248 · Phone 214/248-4900 11. Provide details of relocation of 12" waterline, between MH-16+83.96 and MH-17+13.96. located 12. Waterline "E" in Belt Line Road shall be 16" diameter not 12" as shown. Other than the above stated items, we have no further objections to the plans as submitted. Should you haVe any questions or need additional information, please contact our office. Sincerely, Gabe Favre GF/dsp Steve Goram Taryon Bowman Donald E. Davis Consulting Engineers H. Wayne Ginn, P.E. File 90441