Parkwood P1/FP-CS 830601 (3)HOGAN & RASOR, ,n=. Engineers · I~lanners · Consultants June 1, 1983 Honorable Mayor and City Council City of Coppell 616 S. Coppell Road P.O. Box 478 Co~pell, Texas 75019 Re: Review of Paving and Drainage Improvements on Parkway Boulevard and Moore Road Gentlemen and Mrs. Thompson: As per the request of Mr. Scott Barnett, we have completed our review of the above referenced plans to determine their compliance with the City's requirements and do hereby offer the following: Right-of-Way Plat A. Plate No. i Engineers seal needs to be put on plat. Location, type of material and approximate size of all right-of-way markers, or monuments, need to be indicated on plat. Drainage Area Map A. Plate No. 2 1. Drainage area map shows only one type of run-off coefficient as being 0.45. City's zoning map shows otherwise. Please refer to City's zoning map. 2. Indicate direction of storm water flow with flow arrows. 3. Drainage area map is incomplete. It does not show drainage areas that will actually drain into proposed street. This needs to be shown on drainage area map. Paving - Parkway Boulevard A. Plate No. 3 1. The angle of centerline of street intersection needs to be shown on plan. Suite 800 One (-~alleria Tower 1 ~)3~5~5 Noel Road 214/392-41~00 Dallas, Texas 75240 2. Curb return radius also needs to be shown on plan. 3. Recommend for concrete pavement to be no less than 8 inches thick. 4. Subdivision regulations call for 3500 P.S.I. concrete for this type of street classification. Also if plasticity index of the subgrade is 12 or more, lime stabilization will be required. 5. The proposed street pavement improvements, it appears, will be built above the existing natural ground. Is this because the proposed street improvements are within the lO0-year flood plain. If so, lO0-year flood eleva- tion needs to be indicated on plans. 6. Flow arrows need to be shown on plan. B. Plate No. 4 1. Same as comments for Plate No. 3. 2. Proposed top of curb for north side of street needs to be shown on profile. 3. Bench mark not shown on plan. 4. Drainage easement for storm sewer lateral needs to be provided outside of proposed right-of-way. C. Plate No. 5 1. Same as comments for Plate Nos. 3 and 4. 2. Same as comments 2 and 4 for Plate No. 4. D. Plate No. 6 Same as comments for Plate Nos. 3 and 4. Storm sewer at intersection of Parkway Boulevard with Lodge Road not ~hown as per Sherwood Park, Section One Subdivision. E. Plate No. 7 1. Same as comments for Plate No. 3. 2. Profile for north side of street needs to be shown on plans. F. Plates No. 8 and 9. e Moore Road Same as comments for Plate No. 3. Profile for north side of street needs to be shown on plans. Bench mark not shown on plan. A. Plate No. 10 Water Others 1. The angle of centerline of street intersection needs to be shown on plans. 2. Curb return radius also needs to be shown on plan. 3. Recommend for concrete pavement to be no less than 8 inches thick. 4. Subdivision regulations call for 3500 P.S.I. concrete for this type of street classification. Also, if plasticity index of the subgrade is 12 or more, lime stabilization of the subgrade will be required. 5. Flow arrows need to be shown on the plan. B. Plate No. 11 Same as comments 3, 4 and 5 for Plate No. 10. A. Plate No. 12 1. Bench mark needs to be shown on plan. 2. Show easement, or right-of-way, on plans for proposed 12" water main. B. Plate No. 13 1. Same as comments for Plate No. 12. 2. Add 16-inch valve at intersection of Parkway Boulevard and Phillips Drive. C. Plate No. 14 and 15. Same as comments for Plate No. 12 D. Plate No. 17 1. Sanitary sewer layout for Lines "B" and "C" is not included with plans. 2. At all proposed sanitary sewer manhole locations, provide a minimum of 0.10 feet difference in flow line elevations between the incoming pipe and outgoing pipe. 1. The plan profile sheets for the paving improvements need to show all the proposed, or existing improvements on the plan. Such as water, sanitary sewer and storm sewer improvements. 2. Separate plan profile sheets for storm sewer improvements have not been provided for Parkway Boulevard. 3. Details for paving, drainage, water and sanitary sewer improvements have not been provided for Parkway Boulevard nor Moore Road. 4. Other comments noted on plans. We appreciate the opportunity to assist the City in this matter and please advise us if we can assist you further. Very truly yours, HOGAN & RASOR, INC. Eduardo H. Pe~a kl 4