ParkW CC-18/SPRv-DR 980326 (02)DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Park West Commerce Center. Lots 1 & 3. Block 7 and Lot 3R. Block A. Site Plan Review. to allow the development of 4 office/warehouse facilities on approximately 31 acres of properly, located at the northeast and northwest corners of Wrangler and Enterprise Drives, at the request of Haiti' and Associates. DRC DATE: March 26, 1998 and April 2, 1998 CONTACT: Mike Martin, P.E., Assistant City Engineer (304-3679) COMMENT STATUS: ,/qP RE L IM[NAR Y F4NA~ :gg-gt.F~F~ The minimum driveway spacing on Wrangler Drive and Enterprise Drive is 100' as per the City's Subdivision Ordinance. This could required the driveway on Lots 1 & 3, Block 7 most easterly to be moved west. Also, this could require the driveway on Lot 3R, Block 8 most northerly driveway to be moved south. 2. Show the location of existing driveways If sidewalks are not to be constructed at the time of the development a note must be provided in the plans stating that: "The 4' sidewalks in the right-of-way of Enterprise and Wrangler Drives will be constructed by the property owner when directed by the City Engineer." 4. Impact Fees will be required. 5. Provide preliminary utility plans. ill L