Loading...
Shadowridge P2/FP-CS 850314GINN, INC. March 14, 1985 CONSULTING ENGINEERS Mr. Dino J. Ferralli $chrickel, Rollins, and Associates 604 Avenue H East Arlington, Texas 76011 Re: Shadowridge Estates, Increment Two Final Plat Coppell, Texas Dear Mr. Ferralli: This firm has reviewed the above plat and construction plans. We are recommending that it be placed on the current Planning and Zoning Commission agenda. We will not, however, recommend that it be placed on the City Council agenda for approval until the following items are satisfied: 1. A minimum width of 10' is required.for utility easements. Please furnish names of adjoining land owners on north and west. Please provide larger centerline radii for curves C1 and C6. Ruby Road appears to be the continuation of Plantation Drive. Please consider a change of name for Plantation Drive. Alleys are required behind residential lots. provide at all interior locations. Please An easement for slope and drainage purposes across the north property line should be obtained and shown. Please resolve the conflict with screen walls and alleys. Please provide any requests for variances along with the final plat submittal. 8. Provide payment for assessments per ordinance. In addition to the above items, the construction plans for this development have been reviewed. We have the following comments: 1. Please furnish a street lighting plan for review. 2. Please include a drainage area map with this set. The stated intensities of the increment one map appear unrealistically low for this development. 16135 Preston Road · Suite 106 · Dallas, Texas 75248 · Phone 214/386-6611 Please furnish flushing devices at dead ends of water mains. 4. Install fire hydrants one foot from property lines. Clean-outs for ends of sewer mains should be no more than 150' from a manhole. 6. Vertical curves on sewers are not allowed. ® Please show crossings of water mains on sewer profiles - provide 1.5' minimum vertical clearance. Please review City Streetscape Plan for applicable provisions. An entrance treatment at Ruby Road/ Plantation Drive with a landscaped median is recommended. Please consider pavers and other entrance features at other areas in the subdivision. Minimum 4:1 slopes should be maintained for the entire channel width along north property line, or a separate maintenance agreement should be submitted. 10. Manholes should be 4'-0 diameter, minimum. 11. Valley gutters should be eliminated where possible. 12. Show profiles of centerlines. Please address the above prior to resubmittal of construction plans. Please feel free to contact this office concerning the above. Sincerely, GINN, INC. ohn V. Wankum, P.E. /sr cc: Ron Ragland