Loading...
Shadowridge P4/FP-CS 890808 (2)GINN, INC. CONSULTING ENGINEERS August 8, 1989 Mr. Russell Doyle, P.E. City of Coppell P.O. Box 478 Coppell, TX 75019 Re: Shadow Ridge Estates IV Construction Plans Dear Mr. Doyle: We have reviewed the construction plans for the above referenced project for conformance to City standards and offer the following comments. The visibility triangle, Bethel School Road at Plantation, should be 25'x25', not 22'x22' as shown, to match opposite corner. Harris Drive street dedication should have Volume, Page numbers completed. Approval block for P&Z commission and Mayor should have correct date provided. Construction of Bethel School Road, escrow of monies, or escrow agreement needs to be addressed. Note on Sheet 3, "top of water line shall be no higher than 595.00" needs to be clarified (see drawings). 5. Minimum cover over water lines should be 36". On drainage plan, time of concentration should be 10 minutes, runoff coefficient should be 0.45, "I" should be 11.6 in./hr, and calculation of "Q" would change. There is approximately 80 c.f.s, coming from west (Kaye Street area), which affects southwest portion of this project, that needs to be addressed. The plan sheet depicting the alley geometrics (Sht. 5 of 8) needs to be in compliance with City standards. Width of alley tie to existing street should be 12'. Widening of alley pavement from 10' to 12' should occur on both sides of curve in alley. 17103 Preston Road · Suite 100 · LB 118 · Dallas, Texas 75248 · Phone 214/248-4900 Sheet 5 of 8, Alley transition section: show existing sanitary sewer lines; show proposed manhole #1; show flowlines of culverts; show proposed Bethel School Road paving; verify storm sewer size of 18" RCP; show alley widths in compliance with standards; show thickness and widths of flumes and concrete slopes at culvert. Should you have any questions regarding the above comments or suggestions, please contact us. Sincerely, Gabe Favre GF/dsp cc: Ben dela Cruz T~ry~ ~man Sanford LaHue, Schrickel, Rollins & Assoc. H. Wayne Ginn, P.E. John C. Karlsruher, P.E. File 89305-123 enclosure: set of marked-up plans