Loading...
Vlg at CC S5/PP-CS 960612~'~;pell, exas P.O. Box 478 Coppell, Texas 75019 214-462-0022 June 12, 1996 Jim Sowell Company 3131 McKinney Avenue, Suite 200 Dallas, TX 75204 RE: Village at Cottonwood Creek, Section V, Preliminary_ Plat Gentlemen: This letter is to inform you that Village at Cottonwood Creek, Section V, Preliminary Plat, to allow the development of a 58-1ot single-family residential subdivision on 16.8 acres of property, located at the northeast comer of Sandy Lake Road and Coppell Road, was approved by the Coppell City Council on Tuesday, June 11, 1996, subject to the following: 1. Departmental comments (copy attached) -- regarding Item #1 of the Engineering comments -- the alley between lots 1 and 2, Block A, must. turn back into the subdivision. Regarding the Leisure Services comments, please disregard comment #6; 2. the set back on Lot 26, Block A, should be noted as 25 feet, and 3. a note needs to be made on the face of the plat indicating this subdivision's proximity to the D/FW Airport and subsequent airplane noise. Because of these changes, Council will be the approval authority on your Final Plat. If you have any questions, please contact me at (214) 304-3675. ~aacerely, , i~irect6r of Planning & Community Services Attachment - Engineering and Leisure Services Comments cc: Pat Atkins, Tipton Engineering Isabelle Moro, P&Z Coordinator Building Inspection DEVELOPMENT VIEW COMMI EE ENGINEERING COMMENTS ITEM: W__ga~_e at CoP~.~nw~-- Creek~ Se__ct~__n ¥, Prelimina~_ Plat. to allow the development of a 58 lot re'_s~de.n~ial subdi~.'~n__~n. I~ acreS~n property, located at the northeast comer o:~ oanay Coppell Road a the request of ~Ipton Engineering, Inc. DRC DATE: April 25, 1996 and May 2, 1996 CONTACT: Mike Martin, E. L T., Assistant City Engineer 004-3679) COMMENT STATUS: ~fz[z~7~- 1. You should investigate the possibility of turning the alley back between lots 1 and 2, Block A to intersect with Bricknell Lane. This would eliminate a situation where you have a street, an alley and a street all intersecting a collector street within 250 foot of each other. The City's experience with situations like this is they create havoc with traffic, especially with the school to the east of this property. 2o The entire off-site droinage basin should be shown. 3. The correct visibility easements should be provided for all entrance points onto Coppell and Sandy Lake Road and Minyard Drive. These are informational comments and should have no bearing on the approval of the plat: 4. There is a good potential that you will have some street flooding associated with this drainage design; however, those issues will be addressed during the review of the construction plans. 5. All information concerning this site will be required to be submitted to the City on computer diskette compatible with the City's computer system. Please contact Doug Steven at 304-3683 to obtain additional information. 6. Impact fees will be required. DEVELOPMENT REVIEW COMMITTEE LEISURE SERVICES COMMENTS ITEM: Wdlage at Cottonwood Creek, Section tr, Preliminary Plat, at the request of lipton Engineering, Inc. DRC DATE: April 25, 1996 and May 2, 1996 CONTACT: Gary D. Sims, Director of Ldsu~ Stn,icer,, (304-3560) The Leisure Services Department has reviewed the above referenced development and has the following comments. Signed and sealed Irrigation Plans as identified in the Subdivision Ordinance are required. Irrigation controllers identified are to have the following: Rain Sensor Freeze Protection device Surge Protector Signed and sealed landscape plans as identified in the Subdivision Ordinance are required. Any work which affects city maintained rights of way, parkways, or medians needs to be identified and coordinated through the Leisure Services Superintendent (304-3554). The proposed subdivision will need to comply with the streetscape plan, identified in the Subdivision Ordinance. This includes entry improvements along Sandy Lake Road. The proposed development will be required to follow the guidelines as established in the Parkland Dedication Ordinance. This proposed development is located in Park Zone 2. A fee of $1,285 per dwelling unit will be required at the time of final plat approval. Should there be any questions by committee members or representatives of the proposed development regarding these comments, please feel free to contact Rick Wieland at 304-3553, or Gary Sims at 304-3560. GDS/rsw DRC425.96E