Loading...
Vlgs of C P2/FP-CS 840813GINN, INC. CON.S tI.TING ENGINEERS TO: FROM: DATE: SUBJECT: Mr. Mark Sweeney Coppell, Texas GINN, INC., City Engineer August 13, 1984 Coppell Village Drainage Ditch Improvements Only We have reviewed the above referenced project for compliance with the City of Coppell standards and offer the following comments. Type "Y" inlet at STA. 1+52 is presently undersized for a 72" diameter pipe connection. A minimum 9' x 9' outside wall dimensions are recommended. 2. Show construction details for type "Y" and "S" inlets and also for the Junction box. 3. Locate Junction box directly eastward from existing box culvert and make tie-in. Keep grate inlet at low point and tie into system. 4. Base flows on Q50 not Q25 (Technical Paper #40). 5. Keep velocity in 18" diameter RCP Lateral 12.5 fps or less (if possible). 6. New Property ditch line - add note - "grade to drain," showing flow arrows. If you have any questions concerning any of the above, please contact Kevin Peiffer at GINN, INC., 386-6611. H. Wayne Ginn, P.E. KP/HWG/sr cc: Steve Goram PSA Engineers 16135 Preston Road · Suite 106 · Dallas, Texas 75248 · Phone 214/386-6611