Site PlanADJACENT PROPERTY ZONING = LIGHT INDUSTRIAL
DUI
MASONRY
4
WALL
WROUGHT IRON
FENCE AND
6' WOOD
6' MASONRY
WALL FENCE
Ic = 3]
R = 565,00
T = 157,43 FT\
L = 307,08 FT
CH = N 11'08'23' W
CL = 303,31 FT
TRILAND/NORTHSTED JO
VOLUME 82118, PAGE
D.R.D.C.T.
ZONED LI
(VACANT-FLOOD
/1/2" I
6'
WALL FEN
40 0 40 80 120
Sco,/e 1"
= 40'
~TLI~ R~.
IPROJECT
sn~ I
VICINITY PLAN
N.T.S.
NORTH
BEL
BELT LINE RD
R30.O0
NG =
ROAD
AGRICULTURE
UTLITY EASEMENT VOL. 842?7, PAGE 4004
'g:DQ'.'.'c
c~
30' BUILDING LINE
270,00'
444
g 17,550 S,F,
R30.O0 445
................ 270,00',
O0
230,00'
M 18,400
8.00
R30.O0
00'
225,00'
225,00' 4,500 S,F,
v.2,4'.00
195,00'
195.00' 4,875 ~.F, ~ ........
155.00'
4,650 S,F,
:55,00'
i10
3,300
I10,00'
R54,
6' MASONRY WALL FE
DRAINAGE EASEMENT
VOLUME 86188, PAGE 3055
lc = 35'30'26'
R = 710,00 FT
T = 227,32 FT
L = 440,00 FT
CH = N 44'27'48' W
CL = 432,99 FT
FLOODPLAIN BOUNDARY LINE
ELEVATION 440.00
1/2" I.R.F.
1/2" I.R.F.
443
1/2" I.R.F.
6' MASONRY WALL
FENCE
DENOTES CONCRETE PAVEMENT
TRILAND,/NORTHSTED JOINT VENTURE
VOLIUME 82118, PAGE 0215
D.R.D.C.T.
ZONED L.I
(VACANT-FLOOD PLAIN)
6' IMASONRY WALL
FENICE
30/ -
E
30'
DRAINAGE EASEMENT
VOLUME 86188, PAGE 3055
WALL
lc = 119'19'09"
R = 50,00 FT
T = 85,43 FT
L = 104,13 FT
CH = S 58'07"85' W
CL = 86,30 F'lr
TRILAND/NORTHsTED JOINT VENTUfRE
VOLUME 82118, PAGE 0215
D.R.D.C.T.
ZONED L.I
(VAcANT-FLOOD PLAIN)
TOTAL SITE AREA = 21 0,51 1.19 S.F.
TOTAL BUILDING AREA = 74,891 S.F.
BUILDING
A
B
C
APROX. HEIGHT
21'-0" BUILDING 'A' IS OFFICE AND MANAGER'S QUARTERS
24'--0" BUILDINGS 'B' AND 'M'ARE CLIMATE CONTROLLED
11'-4'
D 11 '-4' PARKING REQUIRED
E 12'-0" 4 PLUS 1/5000 S.F. OF STORAGE = 4 + 73,295/5000 = 19 SPACES
'--4' PARKING PROVIDED
F 1 1,_4, STANDARD PARKING PROVIDED = 17 SPACES
G 11
H 11'-4' HANDICAP PARKING PROVIDED = 2 SPACES
I 11'-4' TOTAL PARKING PROVIDED = 19 SPACES
J 11'-4'
12'X ,30' LOADING ZONES REQUIRED
K 11'-0"
1 SPACE PER 20,000 S.F. STORAGE = 73,295/20,000 = 4 SPACES
L 10'-10"
M 12'-0" 12' X 30' LOADING ZONES PROVIDED 5 SPACES
ALL BUILDINGS ARE ONE STORY
LOT COVERAGE = 35.58%
FLOOR AREA RATIO = 0.36
EXISTING ZONING = 'L.I.' WITH
SUP
FOR SELF STORAGE
All construction shall conform with City
be submitted to Engineering Department
prior to construction,
Standards. Civil drawings shall
for approval and permitting
THERE WILL BE NO POLE LIGHTING IN THIS FACILITY.
LIGHTING WILL BE BY WALL PACK UNITS.
ALL INTERIOR
ALL INTERIOR FIRE LANE RADII ARE 30.00', ALL EXTERNAL FIRE LANE
RADII ARE 54.00'.
ALL STORAGE BUILDINGS WILL BE FULLY SPRINKLERED.
ATTACHED TO
C.C. PACKET
~co'... ~ '...o
WALTER 3. NELSON
~.~ 51833
./
SITE
OF
ASSURED
PLAN
SELF
STORAGE
CONTAINING 4.833 ACRES OF
OUT OF THE SINGLETON THOMPSON
ABSTRACT No. 1495
IN DALLAS COUNTY, TEXAS
AUGUST 21, 2002
LAND
SURVEY