One-line Diagram & DetailsNOTES: 1. SUBCONTRACTOR SHALL PROVIDE ,30AMP, SINGLE PHASE, 120/24-0 VAC, 60HZ SERVICE FOR FIBERTOWER MICROWAVE CABINET. 2. SUBCONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY BEFORE THE START OF CONSTRUCTION. POWER AND TELEPHONE CONDUIT SHALL BE PROVIDED AND INSTALLED PER UTILITY REQUIREMENTS. 5. FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT REFER TO DRAWINGS PROVIDED BY CABINET MANUFACTURER. 4. ALL SERVICE EQUIPMENT AND INSTALLATIONS SHALL COMPLY WITH THE N.E.C. AND UTILITY COMPANY AND LOCAL CODE REQUIREMENTS. 5. SUBCONTRACTOR SHALL INSTALL MIN. 6'-0" OF FLEX CONDUIT WITH ALL CONDUIT FITTINGS (NUTS, REDUCING BUSHINGS, D ELBOWS, COUPLINGS, ETC.) NECESSARY FOR CONNECTION TO THE MICROWAVE CABINET. 6. SUBCONTRACTOR SHALL PROVIDE ELECTRICAL SERVICE EQUIPMENT WITH FAULT CURRENT RATINGS GREATER THAN THE AVAILABLE FAULT CURRENT FROM THE POWER UTILITY. 7. POWER, CONTROL AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR (#14- AWO AND LARGER), 600V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90°C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED. 8. CUT, COIL AND TAPE A 10 FT PIG TAIL FROM END OF FLEX CONDUIT FOR TERMINATION BY MICROWAVE EQUIPMENT MANUFACTURER. 9. SUBCONTRACTOR SHALL FURNISH AND INSTALL A NEMA 5R ENCLOSURE WITH INTERNAL 5/8" THICK PLYWOOD BACKBOARD. SUBCONTRACTOR SHALL COORDINATE WITH LOCAL TELCO UTILITY PRIOR TO PROCURING AND INSTALLATION OF ENCLOSURE AND COMPONENTS. BOND ENCLOSURE TO THE SITE GROUND RING OR BAR WITH #2 AWG COPPER WIRE. TO EXISTING TELCO NOT U $ E D DEMARC LOCATION IN AWS SHELTER (SEE NOTE 2) , DETAIL NTS 200At ,~ EXISTING 200AMP, i 1 -PHASE DISTRIBUTION PANEL 50A I : ""- ~ NEW 50A/2P/240 VAC PLUG-IN BREAKER IN r"/ 2" IMC CONDUIT W/ EXISTING SPARE LOCATION ' PULL WIRE : I , SHELTER WALL , CONDUIT TO PENETRATE NEW ' '1" SHELTER WALL. SEALNOT USED ~~._ WEATHER TIGHT. $ MICROWAVE CABINET , NEW 50A NON FUSED 2-#10 &: 1-#10 G IN i DISCONNECT SWITCH _ 5'-0" MAX_ 1" IMC CONDUIT (NEMA 5R) DETAIL ]~ ~ f~ ~ NTS L LIQUIDTIGHT FLEXCONDUI ,., #2 AWG SUPPLEMENTAL, NOT USED (SEE NOTES 5 &: 8) EQUIPMENT GROUND CONDUCTOR BONDED TO '--' EXISTING TOWER GROUND RING POWER &: TELEPHONE SINGLE LINE DIAGRAM ~~.~ %'/~-~)_7 A " - - ..,,,~_,_,.: ......... .-:.~ O.L.A. PROJECT NUMBER, TFLXO016 O D E A NEW YORK DALLAS DENTON TAP RD/BELTLINE RD '" ~"~'"'-* '"~= L Y N C H 4230 LBJ Freeway, Suite 625, Dallas, TX 75244 200 E. BELTLINE ROAD o Ol/5O/O.3 ISSUED FOR CONSTRUCTION DS JHR SG ' ~BRADLEYNEILGLASSiE ='"': ........................ ,...,,,, ONE-LINE DIAGRAM &: DETAILS tel972.239.6100 fax 972.239.6102 COPPELL, TEXAS 75019 185 BERRY, SUITE 4800 A 01/16/0,3 ISSUED FOR REVIEW DS dHR SG A B S A T TI $ T A v~w. olace.¢om SAN FRANCISCO, CA 94107 NO. DATE REVISIONS BY CHK ,pp'l~,,~ -~.~?/~.1~,~_'~-~-/~44 ; SITE NUMBER DRAWING NUMBER REV CONSULTING ENGINEERS SCALE: AS SHOWN DESIGNED BY: JHR DRAWN BY: DS ..~,~/v~.-~¢,- ¢ ~ DLS0504 LO1 0 6 5 4 ii i~ 3 2 22 x 5,1- % SIZE PSC= : : g Z 0 0 o