Loading...
DRC comments T H £ · C I T Y · 0 F CO-PPEi £ Planning Department 255 Parkway Blvd Coppell, Texas 75019 Phone: 972-304-3678 Fax: 972-304-7092 PROJECT: S-1204, Securlock Self Storage and Minor Plat PLANNING DEPARTMENT CONTACT: Andrea Roy DIRECT DIAL: 972-304-3677 FAX COVER SHEET DATE: November 27, 2002 TO: Andrew Smith Cc: Dowdy Anderson PAGES: FAX: 972-370-1427 FAX: 972-931-9538 Items Transmitted: 1. Agenda for the December 5, 2002 DRC Meeting 2. DRC Comments Remarks: Please revise plats, site plans, landscape plans, and building elevations based on staff recommendations. Should applicant disagree with staff comments please provide reasons why staff recommendations should not be followed when you attend the December 5, 2002 Development Review Committee (DRC) meeting. Each applicant will bring two new sets of revised plats and plans to the December 5, 2002 DRC meeting. Applicants will be asked to show, explain and defend any revision. A representative of the project is required to attend the meeting. Applicant will have till noon Tuesday, December 10th to resubmit fourteen (14) folded copies of revised plans, three (3) reduced paper copies (8 1/2 X 11) and JPEG ,TIF OR SIMILAR ELECTRONIC FORMAT of each exhibit to the Planning Department. If you have any questions or would like additional information, please contact me at 972~304- 3677 or e-mail at aroy~cLcoppeil.tx.us CO?PELL ProjectlD: Project Type: Application Date: Case Manager: Project Description: Agency Buildinglnspection Engineering CITY OF COPPELL DRC REPORT COPPELL SUP-02-0020 Name: 2600 STATE HWY 121 N S.H. 121 and Northpoint Drive, Northeast Corner Securlock Self Storage Special Use Permit 11/19/O2 Andrea Roy zoning change request from LI and C (Light Industrial and Commercial) to LI/C-S-1204 (Light Industrial/Commercial, Special Use Permit-1204), to allow the construction of a 49,380 square-foot mini-warehouse use, with a 1,900 square-foot caretakers quarters, and 5,520- square feet of office/warehouse 1 of 6 Comments All storage buildings required to have automatic fire sprinkler systems. 60~foot front yard setback required with front yard parking. 1. All work along S.H. 121 Frontage Road will have to be approved and permitted by TxDOT (driveways, culverts, drainage). Date of Action Reviewed By 11/25/02 Greg Jones 11/25/02 Teresa Turner 2. More clearly define and label rights-of-way and property line limits on the site plan and civil drawings. 3. The domestic water and irrigation cannot be taken off of the fireline. The existing 8" waterline along the east side of this parcel is a public waterline. All water meters must be contained within the right-of-way or in easements. 4. A double detector check and vault is required where the fireline connects to the public waterline. These must be contained within easements. 5. Eliminate the 18" headwall and install a curb or grate inlet at the driveway to Northpoint Drive. 6. Eliminate the 30" headwall and tie into the 36" culvert at the driveway to S.H. 121. COPPELL ProjectlD: Project Type: Application Date: Case Manager: Project Description: Agency Fire Administration Parks and Recreation Planning Department CITY OF COPPELL DRC REPORT COPPELL SUP-02-0020 Name: 2600 STATE HWY 121 N S.H. 121 and Northpoint Drive, Northeast Corner Securlock Self Storage Special Use Permit 11/19/02 Andrea Roy zoning change request from LI and C (Light Industrial and Commercial) to LI/C-S-1204 (Light Industrial/Commercial, Special Use Permit-1204), to allow the construction of a 49,380 square-foot mini-warehouse use, with a 1,900 square-foot caretakers quarters, and 5,520- square feet of office/warehouse 2 of 6 Comments 1. All gates across fire lanes to be equipped with an Opticom device with KNOX override. Date of Action Reviewed By 11/25/02 Travis Crump 2. All storage buildings to be equipped with an automatic fire sprinkler system and alarm. 3. Provide personnel access gates to rear of buildings. 4. Domestic and irrigation lines can not be taken off of fire line. 5. Detector checks are required at each point of tie in to city lines. No Comments Please Note that staff has provided a technical review of the submitted site plan, landscape plan, and building elevations. Any comments or recommendations should not be construed as support for the proposed project. Staff should reiterate that the proposed land use is not supported by the Coppell Comprehensive Plan and does not meet the special use permit criteria necessary for staff support. 11/22/02 John Elias 11/26/02 Andrea Roy The proposed 40% Office/60% Warehouse flex units are not permitted within the "C" Commercial Zone District. Per Section 12-23-1(#7) of the Zoning Ordinance, only limited warehousing is permitted within the Commercial zone, which is defined as 20% of the floor area of the building. If the applicant wishes to proceed with this design at 80% office/20% warehouse, it may do so and simply revise the notations on the site plan. However, the only way in which to allow a higher percentage of warehouse would be through a rezoning to "LI" Light Industrial. While staff understands that this is part of the COPPELL ProjectlD: Project Type: Application Date: Case Manager: Project Description: ARency CITY OF COPPELL DRC REPORT COPFELL SUP-02-0020 Name: 2600 STATE HWY 121 N S.H. 121 and Nodhpoint Drive, Northeast Corner Secudock Self Storage Special Use Permit 11/19/O2 Andrea Roy zoning change request from LI and C (Light Industrial and Commercial) to LI/C-S-1204 (Light Industrial/Commercial, Special Use Permit-1204), to allow the construction of a 49,380 square-foot mini-warehouse use, with a 1,900 square-foot caretakers quarters, and 5,520- square feet of office/warehouse 3 of 6 Comments mini-storage use, this aspect does not comply with the definition of mini-warehouse by the Coppell Zoning Ordinance. Please revise plans according. Date of Action Reviewed By Site Plan 1. Comply with Section 12-23-3 (1 .A)"C" District Area Regulations, which requires a 60' front yard setback if front yard parking is utilized. As proposed, front yard parking is present. The proposed office/apartment and the office/warehouse flex units must be shifted outside the 60' front yard setback. 2. Comply with Section 12-31-3 Off-street loading space, all districts, which requires one 12' x 30' loading is required per 20,000-sq. ft. of gross area. The proposed site design requires a total of three spaces. 3. Provide one typical parking space dimension per parking row, to ensure that each space measures the minimum 9' x 19'. 4. Comply with Section 12-29-4 (3i) (Signage) of the Zoning Ordinance and revise the proposed attached signs to be individually mounted channel letters in white, ivory, black, or neutral colors. Logos in any color are permitted, but may not exceed 20 percent of the area of the sign. 5. Are signs proposed to be located on the proposed office/warehouse flex space along S.H. 121. If so, these must shown as part of this application. 6. Eliminate one monument sign along S.H. 121 in accordance with Section 12-29-4 (2) (Ci) (Monument Signs) of the Zoning Ordinance, which only allows one 60 sq. ft. monument sign per street frontage. 7. Revise design of the proposed monument signs to comply with Section 12-29-4 (2) Monument Signs, which indicates that the sign COFFELL Project ID: Project Type: Application Date: Case Manager: Project Description: Agency CITY OF COPPELL DRC REPORT COFFELL SUP-02-0020 Name: Securlock Self Storage 2600 STATE HWY 121 N S.H. 121 and Northpoint Drive, Northeast Corner Special Use Permit 11/19/02 Andrea Roy zoning change request from LI and C (Light Industrial and Commercial) to LI/C-S-1204 (Light Industrial/Commercial, Special Use Permit-1204), to allow the construction of a 49,380 square-foot mini-warehouse use, with a 1,900 square-foot caretakers quarters, and 5,520- square feet of office/warehouse 4 of 6 Comments may only contain the name, logo, address, product or service, and may not be made of plastic of similar material. (Remove Cooled/Heated) A masonry sign and base with individual plastic letters would be acceptable. 8. Indicate the exterior source of light for the monument sign. 9. Relocate all proposed monument signs outside the 15' landscape buffer. 10. Staff would recommend that the phone number and website be eliminated from all attached signage. Staff can not support this design. 11. Staff would recommend that the dumpster and enclosure be relocated to a less visible location on the site and must be outside the 60' front yard setback. 12. Indicate spacing between all proposed driveways, from edge to edge. 13. Do not resubmit Sheet A1.1 of the plan set. This is net needed for staff review at this level. 14. More Clearly delineate property lines of subject site verse adjacent proposed restaurant site. Staff would recommend that line weight be slightly increased for better visibility. 15. More Clearly delineate zoning line between Commercial & Industrial Zoning. 16. Please note that the requested Special Use Permit is to allow the mini-storage facility (and manager's apartment) within the Light Industrial & Commercial Zone. Any use that locates within the office/whse flex space in the Commercial zone must comply with the permitted uses in the Commercial District or request a special use permit amendment to allow the use, if a permitted use by Special Use Permit. Please provide a note to this affect on the plan. Date of Action Reviewed By COPPELL Project ID: Project Type: Application Date: Case Manager: Project Description: Agency CITY OF COPPELL DRC REPORT COPPELL SUP-02-0020 Name: 2600 STATE HWY 121 N S.H. 121 and Northpoint Drive, Northeast Corner Securlock Self Storage Special Use Permit 11/19/02 Andrea Roy zoning change request from LI and C (Light Industrial and Commercial) to LI/C-S-1204 (Light Industrial/Commemial, Special Use Permit-1204), to allow the construction of a 49,380 square-foot mini-warehouse use, with a 1,900 square-foot caretakers quarters, and 5,520- square feet of office/warehouse 5 of 6 Comments Date of Action Reviewed By Elevations 17. Ensure full compliance with Section 12-23-5 (2) Commemial District Type of Construction, which requires the back of an architectural feature be finished of a material that is of the same or similar as the front of the feature. 18. Ensure full compliance with Section 12-25-5 Light Industrial District Type of Construction, which requires 80 percent masonry materials. 19. Ensure full compliance with Section 12-23-5 (1) Commercial District Type of exterior construction, which indicates that all structures must be 80 percent masonry and that other brick colors (other than earth tone colors) shall not exceed 20 percent of the building elevation. It appears that some elevations do not meet this requirement. Landscape 20. Revise inconsistencies among site plan and landscape plan sheets. Is the masonry wall intended to be either 6' or 7'. 21. Comply with Section 12-34-8 (G) (Perimeter Landscaping) and provide the required wall/fence/hedge/berm along the east property line adjacent to the paved area, which must be screened from adjacent properties. 22. Revise Per[meter Landscaping along the east property line, where 18 trees are required instead of the 11 as shown. Revise Landscape calculations accordingly. 23. Staff would recommend that some additional level of landscape detail along the S.H. 121 frontage be provided. 24. Provide Exhibit showing the areas dedicated to perimeter, interior, and non-vehicular landscaping. COl'FELL ProjectlD: Project Type: Application Date: Case Manager: Project Description: CITY OF COPPELL DRC REPORT COFFELL SUP-02-0020 Name: Securlock Self Storage 2600 STATE HWY 121 N S.H. 121 and Northpoint Drive, Northeast Corner Special Use Permit 11/19/02 Andrea Roy zoning change request from LI and C (Light Industrial and Commercial) to LI/C-S-1204 (Light Industrial/Commercial, Special Use Permit-1204), to allow the construction of a 49,380 square4oot mini-warehouse use, with a 1,900 square-foot caretakers quarters, and 5,520- square feet of office/warehouse 6 of 6 Agency Comments Date of Action Reviewed By