Loading...
DRC commentsCOI:'I:'ELL Prolect ID SPA-03-0072 Address 300 Royal Ln CITY OF COPPELL DRC REPORT Project Name COl'FELL Freeport North, Lot 3, Block 3 (Dexas) Proiect TyPe ADDIiCation Date Case Manager P foiect Description Site Plan Approval 9/17/2003 Matt Steer To allow the development of an approximate 167,093 square-foot office/warehouse on 12.14 acres Agency Building inspection Electdc and Gas Engineering 1 of 2 Reviewed By Review Date Greg Jones 9/25/2003 Jeff Curry 9/25/2003 Teresa Turner 9/25/2003 Fire Administration Travis Crump 9/25/2003 Parks and Recreation John Elias 9/26/2003 No comments received Site Plan Acceptable 1. Indicate dimensions, storage lengths, transitions, etc. for the proposed northbound left turn lane. Additional signage may be required. 2. No encroachments or structures can be located within the limits of the floodplain. 3. Grading and Drainage Area information should be located on separate sheets. 4~ It appears that the curb return for the drive on Royal Lane is in conflict with the existing recessed curb inlet. The curb return cannot begin within the pavement transition of the recessed inlet. 5. All water and sanitary sewer connections must be made via bore. 6. More clearly show all existing driveways across from this preperty. Driveways must either align of be offset a minimum of 125'. 7. Indicate the driveway turning radii. 8. Indicate the primary truck entrance. No Comments Received 1. Tree retribution calculations on the plans are incorrect. 2. Correct tree retribution calculations are as follows: Total trees on site 1832" (DBH) Trees removed 1549" (DBH) Trees preserved 283" (DBH) Preservation credit 239" (DBH) 15% Landscape credit 318" NET RETRIBUTION 992" A contribution to the City of Coppell Reforestation and Natural Areas Fund in the amount of $99, 200.00 will be required. COPPELL Agency Planning Department Reviewed By Matt Steer CITY OF COPPELL DRC REPORT Review Date 9/25/2003 COPPELL Comments General Comments: 1. Please show building fronting Royal Lane as Royal Lane serves as a Major Arterial, and consider increasing the volume of the front to better define the entrance. 2. Submit ceior renderings of the elevations for review at the DRC meeting. 3. Ensure consistency between easements being platted and what is shown on site plan. 4. Show screened refuse location on plans. 5. Spell check the set of plans (8' 0" Heigh). Site Plan Specific: 1. Please include the Site Data Table as follows: a. Existing zoning, b. Proposed use, c. Square footage of each proposed use, d. Building area (gross square footage), e. Building height, f. Required and provided parking per each use, g. Proposed lot coverage, and h. Floor Area Ratio. 2. Please show the existing zoning districts adjacent to the property. 3. Check location of sign vs. proposed landscaping. Submit sign rendering with dimensions and materials to be used. 4. Show dimensions of proposed curb cuts along with the inside and outside turning radii (minimum 30' inside and 54' outside). 5. Is this all two way traffic within the site? 6. Stained and stamped concrete required at each ingrass/egress point. 7. Ensure compliance with Texas Accessibility Code for all proposed sidewalks. 8. There is a sidewalk leading up to the building, and on the west elevation there is no door shown. 9. Please coordinate with Engineering for the median and curb cuts. Landscape Plan Specific: 1. Show proposed elevations on the proposed berms shown just within the property lines on landscape plan. 2. Please include a landscape island for every 15 parking spaces (minimum 150 square feet). 3. Add three trees to north property line. COFFELL Prelect ID RP-03-0073 Address 300 Royal Ln CITY OF GOPPELL DRC REPORT Pmie~tName COFFELL Freepod North, Lot 3, Block 3 Addition (Dexas) Prolect Tv~e ADolication Date Case I~anaaer Prolect Description Reptat 9/17/2003 Matt Steer To allow the development of an approximate 167,093 square-foot office~varehouse on 12.14 acres located at the northwest corner of Creekview and Royal Lane, at the request of Pacheco Koch Consulting Engineers. Agency Building inspection Electric and Gas Engineering 1 of 2 Reviewed By Review Date Greg Jones 9/25/2003 Jeff Curry 9/25/2003 Teresa Turner 9/25/2003 Fire Administration Travis Crump 9/25/2003 Parks and Recreation John Elias 9/26/2003 No Comments Received Plat Unacceptable, please contact Jeff Curry to discuss easement requirements. 1. Include a fire lane data table. 2. Label the limits of the floodplain. 3. Additional easements may be required during engineering review. 4. Add the following note to the plat: "Sidewalks will be constructed at the expense of the property owner when deemed necessary by the City Engineer." 5. Add the following note to the plat: "The City of Coppell will have no responsibility for maintenance of the floodplain/floodway areas as shown hereon; however, the Cit~ does have the authority to regulate activity in the floodway/floodplain as per the City's Floodplain Ordinance. The maintenance of these areas shall be the sole responsibility of the individual owner(s) adjacent to said areas. These areas are to remain free of improvements that may obstruct the flow of stormwater and protected from potential erosion by the owners. No fences will be allowed in the floodplain, along with any other structures as per the City's Floodplain Ordinance." No Comments Received No Comments. COFFELL Agency Planning Department Reviewed By Matt Steer CITY OF COPPELL DRC REPORT Review Date 9/25/2003 COFFELL Comments 1. Please show the number of acres in the title 2. Please depict Creekview on the ¥icinity Map. 3, The TP&L Easement does not show width, It encroaches within the Firelane Easement to be dedicated by this plat. 4. There is a 15' Oncor Electhc Delivery Company Easement shown on the plat. Once acceptable to the Electric and Gas Agency, it should be designated as an Electric Easement (not specifying a specific company as it might change in the future). 5. Please include the boundaries of FEMA defined flood plain of Cottonwood Branch. 6. Cottonwood Branch should be labeled properly (possibly with arrows indicating where it is). 7. Depict the minimum finished floor elevations on the plat. 8, AT&T signature block should be revised to Comcast. 9. Is it acceptable surveying practise to have a "point in creek - not set"? 10. Please submit an additional $35 to make up what was lacking on the platting fees ($555 required and $520 initially submitted).