DRC commentsCOPPELL Proiect ID RP-04-0036 Address Freeport Pkwy CITY OF COPPELL DRC REPORT Project Name COPPELL Duke-Freeport Addition, Lots 6 and 7, Block A Pmiect Type Replat Aoolication Date 5/19/2004 Case Manafler Proiect Description being a Replat of a podion of Lot 2, Block A, to allow the construction of two buildings, a 140,000 square foot building on Lot 6 and a 70,000 square foot building on Lot 7 Agency Building Inspection Electdc and Gas 1 of 3 Reviewed By Review Date Greg Jones 5/27/2004 Comments 1. No comments made. No Comments Received. COPPELL Engineering Reviewed By Ken Griffin CITY OF COPPELL DRC REPORT Review Date 5~26~2004 COPPELL Plat document - 1. There are two areas called out as 20' drainage easements by this plat that cross Lot 6 to accommodate drainage from Lot 7. Those easements should be private easements and the improvements should be maintained by the individual property owners. The City will not perform maintenance on those storm drain lines. 2. On Lot 7 you show a 10' water easement and a 15' sanitary sewer easement. Again, those should be private easements and improvements should be maintained by the property owner. Should consider relocating the water and sewer to serve Lot 6, on Lot 6, so that these easements are not required. Drainage Plan - 1. The storm drainage system will be privately owned and maintained. The City of Coppell will not perform maintenance, so you will need some sort of agreement with the adjacent property owners. Water & Sewer Plan - 1. The fire line on Sheet C4.0 shows tying into the existing system on Lot 5 Block A. That is a privately owned and maintained system and as such needs to remain independent of this fire line. Loop your fire line exclusive of this property. 2. The same is true of the fire line on Lot 6 versus Lot 7 - those also need to be independent of each other 3. This is also true of the water and sewer service to these two buildings. You cannot combine the services, they must be independent which will require the extension of the existing 8" sanitary sewer onto Lot 7 and two service lines, one for Lot 7 and one for Lot 6. 4. Water service will need to be relocated from Lot 7 to Lot 6 to serve the Lot 6 building as well. Additional comments may be forthcoming during the full engineering review. Fire Administration Parks and Recreation Tim Oates John Elias 5/26/2004 5/26/2004 NOTE: General Engineering Observations These comments do not constitute a detailed review of any Engineering submittals. Detailed review will be performed after approval by City Council Grading Plan sheet - 1, The finish floor elevation of the buildings should be shown. 1. Indicate Fire Lane turning radii; 30' inside, 54' outside. 2. Length of 'dead-end' Fire Lane on south side of Freeport 12 not indicated. No comments. COPPELL ~lanning D~partment Reviewed By Matt Steer CITY OF COPPELL DRC REPORT Review Date 5/27/2004 COPPELL Comments 1. Ensure the easements on plat match what is shown on the site plan. 2. Rename "fire lane easements" to "mutual access and fire lane easements". 3. Show alt bearings and distances of the fire lane and mutual access easements. 4. Provide proof the TxU easement shown to be abandoned was created by a previous plat.