Loading...
Con. Grading Plan Pg. 1 I < LC .< n~ o~ bjo Z TC 518'.3D G 517,80 !xx" 'L 517,60 LEVEL AT 517,60 / LEVEL AT LC BM// 2 BMI I 1/2~INCH IRON W/ PACHECO KOCH CAP FOUND BENCH ll,fA t?K LIS 7' / / / / / "[]" CUT ON TH:E NW CORNER OF CONCRETE PAD ON THE NORTH SlOE OF BETHAL ROAD, 20± NORTH OF EDGE OF ASPHALT 200± EAST FROM THE CENTERLINE OF FREEPORT PARKWAY, ELEV=512,18 ' [] ' CUT SET ON THE TOP OF A CONCRETE STORM INLET ON THE LEFT SI,DE OF FREEPORT PARKWAY, BEING 80J: SOUTH OF THE NORTH ENTRANCE TO 6,35 FREEPORT PARKWAY. ELEV=518.08 " [] " CUT SET ON THE TOP OF THE BACK OF CURB WEST OF a ONE STORY CONCRETE lILT-WALL BUILDING AT 655 FREEPORT PARKWAY. ELEV=514.77 ~LS 1711.39' EL 516.60 t T LEVEL AT 517.60 LEVEL AT 517.10 / EL 516.60 TC 518.30 G 517.80 EL 517.60 .I 520- '520 ,---------520 ,/%, / / FREEPORT Xl LOT 6, BLOCK A DUKE-FREEPORT ADDITION 3.559 ,ACRES 72,861 SF) % c----% ................. TEXAS DUGAN UMITED PARTNERSHIP ,, ---- (VOL. 2000251, PG. 2678) ......... - .... 52 = 1 O0 F.F. I TC 518.65 i O 518.15 518 o. ----~ ............. t:~------ ~ ' ~ , '~' ,~ ~';i~.~ ... ,'-- ~ 7' '- .......... ,.: .... ..... ..' - FREEPORT Xll LOT 5, BLOCK A i . F.. ~ F. N D DUKE-FREEPORT ADDITION PPe wl, lo ICV® COo E ~13 .--~ ~12.39, 512.39. 611,92 BOLLARD ELECTRIC METER POWER POLE LIGHT STANDARD WATER METER , WATER VALVE IRRIGATION CONTROL VALVE FIRE HYDRANT CLEANOUT MANHOLE 1/2-INCH iRON ROD W/"PACHECO KOCH" CAP SET PROPERTY LiNE FENCE OVERHEAD UT1UTY UNE UNDERGROUND WATER LINE UNDERGROUND ELECTRIC LINE UNDERGROUND TELEPHONE UNE UNDERGROUND CABLE LINE UNDERGROUND SANITARY SEWER LINE EXIST CONTOUR EXIST SPOT ELEVATION EXIST TOP OF CURB ELEVATION EXIST GUTTER ELEVATION 0 15 JO 60 GRAPHIC SCALE IN FEET 1 ..... 515- m~ 90 I I I I I I I I I I ISSUED FOR PRELIMINARY PRICING PURPOSES ONLY (SUBJECT TO REVISION PRIOR TO CONSTRUCTION) THESE OOCUMENTS HAVE BEEN PREPARED BY THE ENGINEER WITH THE INTENT OF COMPLYING WITH ALL CITY STANDARD REQUIREMENTS. THESE DOCUMENTS HAVE NOT BEEN APPROVED ANO RELEASED FOR CONSTRUCTION BY THE CITY AS OF THIS DATE AND, THEREFORE, REVISIONS MAY BE REQUIRED PRIOR TO CONSTRUCTION. BY ANY USE OF THESE DOCUMENTS, THE USER AFFIRMS THEIR UNOERSTANOING OF THE PRELIMINARY STATUS OF THE PLANS AND THE POTENTIAL FOR REVISION PRIOR TO ANY CONSTRUCTION. PRELIMINARY NOT FOR CONSTRUCTION THIS DOCUMENT iS ISSUED FOR THE PURPOSE OF SCHEMATIC REVIEW ONLY ANO IS NOT iNTENDED FOR PERMITTING, BIDDING, OR CONSTRUCTION PURPOSES. PLANS PREPARED UNDER THE DIRECT SUPERVISION OF STE~J~ A. MARKUSSEN, P.F~ TEXAS REGISTRATION NO. 70090 DATE; o~/0~/20o~ D" "ke CONSTRUCTION 5495 Belt Line Rood Suite 360 Dallas, TX 75240 Phone: (972) 3.61-6700 Fax: (972) 5,61-6800 '1 b o -~17~o ~ = II - zg8o Certified By: Drawing Number: C2.0 Duke Job Number: FPN011-O00 2052-04.058;