Con. Grading Plan Pg. 1 I
<
LC
.<
n~ o~ bjo
Z
TC 518'.3D
G 517,80
!xx" 'L 517,60
LEVEL AT 517,60 /
LEVEL AT
LC
BM// 2
BMI I
1/2~INCH IRON
W/ PACHECO KOCH
CAP FOUND
BENCH ll,fA t?K LIS 7'
/ / / / /
"[]" CUT ON TH:E NW CORNER OF CONCRETE PAD ON THE
NORTH SlOE OF BETHAL ROAD, 20± NORTH OF EDGE OF
ASPHALT 200± EAST FROM THE CENTERLINE OF FREEPORT
PARKWAY,
ELEV=512,18
' [] ' CUT SET ON THE TOP OF A CONCRETE STORM INLET ON
THE LEFT SI,DE OF FREEPORT PARKWAY, BEING 80J: SOUTH OF
THE NORTH ENTRANCE TO 6,35 FREEPORT PARKWAY.
ELEV=518.08
" [] " CUT SET ON THE TOP OF THE BACK OF CURB WEST OF a
ONE STORY CONCRETE lILT-WALL BUILDING AT 655 FREEPORT
PARKWAY.
ELEV=514.77
~LS
1711.39'
EL 516.60
t
T
LEVEL AT 517.60
LEVEL AT 517.10
/ EL 516.60
TC 518.30
G 517.80
EL 517.60
.I
520-
'520
,---------520
,/%,
/
/
FREEPORT Xl
LOT 6, BLOCK A
DUKE-FREEPORT ADDITION
3.559 ,ACRES
72,861 SF) % c----% .................
TEXAS DUGAN UMITED PARTNERSHIP ,, ----
(VOL. 2000251, PG. 2678) ......... - ....
52
= 1 O0
F.F.
I
TC 518.65 i
O 518.15
518 o.
----~ ............. t:~------ ~ ' ~ , '~' ,~ ~';i~.~ ... ,'-- ~ 7' '-
.......... ,.: .... ..... ..' - FREEPORT Xll
LOT 5, BLOCK A
i . F.. ~ F. N D DUKE-FREEPORT ADDITION
PPe
wl, lo
ICV®
COo
E
~13 .--~
~12.39,
512.39.
611,92
BOLLARD
ELECTRIC METER
POWER POLE
LIGHT STANDARD
WATER METER ,
WATER VALVE
IRRIGATION CONTROL VALVE
FIRE HYDRANT
CLEANOUT
MANHOLE
1/2-INCH iRON ROD
W/"PACHECO KOCH" CAP SET
PROPERTY LiNE
FENCE
OVERHEAD UT1UTY UNE
UNDERGROUND WATER LINE
UNDERGROUND ELECTRIC LINE
UNDERGROUND TELEPHONE UNE
UNDERGROUND CABLE LINE
UNDERGROUND SANITARY SEWER LINE
EXIST CONTOUR
EXIST SPOT ELEVATION
EXIST TOP OF CURB ELEVATION
EXIST GUTTER ELEVATION
0 15 JO 60
GRAPHIC SCALE IN FEET
1
..... 515-
m~
90
I
I
I
I
I
I
I
I
I
I
ISSUED FOR PRELIMINARY PRICING PURPOSES ONLY
(SUBJECT TO REVISION PRIOR TO CONSTRUCTION)
THESE OOCUMENTS HAVE BEEN PREPARED BY THE ENGINEER WITH THE INTENT OF
COMPLYING WITH ALL CITY STANDARD REQUIREMENTS. THESE DOCUMENTS HAVE NOT
BEEN APPROVED ANO RELEASED FOR CONSTRUCTION BY THE CITY AS OF THIS DATE
AND, THEREFORE, REVISIONS MAY BE REQUIRED PRIOR TO CONSTRUCTION. BY ANY
USE OF THESE DOCUMENTS, THE USER AFFIRMS THEIR UNOERSTANOING OF THE
PRELIMINARY STATUS OF THE PLANS AND THE POTENTIAL FOR REVISION PRIOR TO
ANY CONSTRUCTION.
PRELIMINARY
NOT FOR CONSTRUCTION
THIS DOCUMENT iS ISSUED FOR THE
PURPOSE OF SCHEMATIC REVIEW ONLY
ANO IS NOT iNTENDED FOR PERMITTING,
BIDDING, OR CONSTRUCTION PURPOSES.
PLANS PREPARED UNDER THE DIRECT
SUPERVISION OF STE~J~ A. MARKUSSEN, P.F~
TEXAS REGISTRATION NO. 70090
DATE; o~/0~/20o~
D" "ke
CONSTRUCTION
5495 Belt Line Rood
Suite 360
Dallas, TX 75240
Phone: (972) 3.61-6700
Fax: (972) 5,61-6800
'1
b o
-~17~o ~ =
II
-
zg8o
Certified By:
Drawing Number:
C2.0
Duke Job Number:
FPN011-O00
2052-04.058;