Loading...
Con. Water & San. Sewer Plan P1u I I m · 'OHL [ ~RS "1"1 __ , I I I I INSTALL: 1-8'x6' TEE 1-8' VALVE t-F,H. 1-8' VALVE 1-8'x45' BEND N 00'32'27" E °pp OHL 1711.39' INSTALL: 1-8'x6' TEE 1-6' VALVE 1-F,H. 1 ·pp PROPOSED FDC REFER TO FIRE PROTECTION4 PLANS FOR DETAILS PP w/ TRANS. INSTALL: 1-8"x6" TEE 1-6' VALVE 1 -F.H. 1-8' VALVE I I I I I I -I I I I OHL I I I '1 IN STALL: 1-8·x45' BEND INSTALL: 1-8'x6" TEE 1-8' VALVE 1-F,H, 1-8' VALVE PROPOSED STORM LiNE 1.0 / / I BM// 2 BM// 7 BM// 8 PROPOSED STORM LiNE ~2.0 Z P~ ~0 0 0 0 LdO x:_J =l 1-8'x45' BEND INSTALL: 1-8'x6" TEE 1-6· VALVE 1-F,H. 1-8" VALVE I I INSTALL: I 1-8"x45' BEND I 1/2-INCH IRON RO0 CAPW/'PACHECOFouND KOCH' 8ENCI¢ MA L /$ 7' " [] " CUT ON THE NW CORNER OF CONCRETE PAD ON THE NORTH SlOE OF BETHAL ROAD, 204- NORTH OF EDGE OF ASPHALT 2004- EAST FROM THE CENTERLINE OF FREEPORT PARKWAY, ELEV=512.16 · [] · CUT SET ON THE TOP OF A CONCRETE STORM INLET ON THE LEFT SlOE OF FREEPORT PARKWAY, BE]NO 804- SOUTH OF THE NORTH ENTRANCE TO 635 FREEPORT PARKWAY. ELEV= 516.06 · [] · CUT SET ON THE TOP OF THE BACK OF CURB WEST OF A ONE STORY CONCRETE TILT-wALL BUILDING AT 635 FREEPORT PARKWAY. ELEV=514.77 FREEPOR:T Xl LOT 6, BLOCK A OUKE-FREEPOR'T ADDITION 3. 559 ACRES 72,861 SF) TEXAS DUGAN LIMITED PARTNERSHIP (VOL. 2000251, PG. 2678) F.F. = 5,21.00 FL 515,00 CONNECT TO EXISTING 8" WATER INSTALL: I"xB' TAPPING ANO VALVE INSTALL FH I iNSTALL FH m m -- S 00'30'15' W FREEPORT Xll a. BOLLARD RUG ELECTRIC METER PP. POWER POLE L $~. LIGHT STANDARD w~o WATER METER , ~ve WATER VALVE ICYe IRR:IGAT~ON CONTROL VALVE m~ FIRE HYDRANT COo CI_EANOUT UH ~ MANHOLE IRS 1/2-IN'CH IRON ROD W/"PACHECO KOCH· CAP SET · PROPERTY LiNE x . FENCE -- OHL.-- OVERHEAD UTIUTY LINE ~'w UNDERGROUND WATER LINE E UNDERGROUND ELECTRIC LINE -- T- UNDERGROUND TELEPHONE LINE C I UNDERGROUND CABLE LINE --~"ss · UNDERGROUND SANITARY SEWER LINE LOT 5, BLOCK A DUJKE-FREEPORT ADDITION CO 15 30 60 GRAPHIC SCALE IN FEET FL 515,00 INSTALL 4' D,IA. SSMH CONNECT TO EXISTIN(,~ 8" WATER 'INSTALl-' 1-8'x8' TAPPING INSTALL FH INSTALL: -8'xll 1/4' BEND EX. B' WTR. S FH ICV INSTALL: 1-8'x6' TEE 1-8' VALVE 1-F,H. 1-8' VALVE itNSTALL: i 1-8·x22 1/2' BEND '.. .'. :;.:...:,. ~ .'.~... .~ ,,.~' .' ~ // "... ,.. · ;'".:..,:':'.. :::// I I 9O 1$BUED FOR PRELIMINARY PRICING PURPOSES ONLY (SUBdECT TO REVISION PRIOR TO CONSTRUCTION) THESE DOCUMENTS HAVE BEEN PREPARED BY THE ENGINEER WITH THE INTENT OF COMPLYING WITH ALL CITY STANDARD REQUIREMENTS. THESE DOCUMENTS HAVE NOT BEEN APPROVED AND RELEASED FOR CONSTRUCTION BY THE CITY AS OF THIS DATE AND, THEREFORE, REVISIONS MAY BE REQUIRED PRIOR TO CONSTRUCTION. BY ANY USE OF THESE DOCUMENTS, THE USER AFFIRMS THEIR UNDERSTANDING OF THE PRELIMINARY STATUS OF THE PLANS AND THE POTENTIAL FOR REVISION PRIOR TO ANY CONSTRUCTION. PRELIMINARY NOT FOR CON3TRUCTION THIS DOCUMENT tS ISSUED FOR THE PURPOSE OF SCHEMATIC REVIEW ONLY AND tS NOT INTENDED FOR PERMITTING, BIDDING, OR CONSTRUCTION PURPOSES. PLANS PREPARED UNDER THE DIRECT SUPERVISION OF STEVEN A. MARKUSSEN. P.E. TEXAS REGISTRATION NO. 70090 DATE: 06/05/2004 D'l "ke CONSTRUCTION 5495 Belt Line Rood Suite 360 Dallas, TX 7524.0 Phone: (972) 561-6700 Fox: (972) 561-6800 Certified By: Drawing Number: C4. O Duke Job Number: FPN011-O00 2052-04.058