Loading...
Con. Water & San. Sewer Plan P2o I I I HILLWOOD FUND NO. 1, L.P. I (VOL, 2003006, PO. 00074) I --x x x 1-8%8 OHL ? ePp OHL ~' o_o'~'~' ~ _ _ _ X X X X X 9EDUCER FREEPORT Xll LOT 7, BLOCK A DUKE-FREEPORT ADDITION 2.570 ACRES 42,670 SF) TEXAS DUOAN LIMITED PARTNERSHIP (VOL. 2000251, PO, 2678) F.F. = 521.OO INSTALL 4' DiA. SSMH FL 514.50 -INCH IRON RO0 CAP FOUND INSTALL: 8'x6' REDUCER 1-F,H. II Ii PROP. 15'x10' WTR. ESMT, / / / 4' DIA, SSMH CONNECT TO EX. 8' SS -' CUT IN/ CONCRETE I¢OUN O / / / / / LS / / / / / / / / / / / / / / CONNECT TO EX. 12" WTR. INSTALL: 2-12"x2' TAPPING SADDLE W/VALVE 4-2' W~ (DOM) t-2' WM ORR.) ! ! ,/ OHL , PP ,OHL PROPOSED FDC REFER TO FIRE PROTECTION PLANS FOR DETAILS --X X IN STALL: __ 1-8"x45' BEND I,NSTALL: 1- 8'x4-5' BEND ~ J INSTALL: 1-8"x6" TEE 1-8" VALVE 1-F.H. 1-8" VALVE CONNECT TO EX. 12' INSTALL: 1-Z' W~ (DOM) 1-2" WM 1-DET, CHK / / / / / / / / / / / / / ? ! ! / / 5' 1.2 V1E / / / / / ! / / / ,> ! ! ! ! BENCH MA tTK L /$ T ' BM~I 2 "[]" CUT ON THE NW CORNER OF CONCRETE PAD) ON THE NORTH SIDE OF BETHAL ROAD, 20:t: NORTH OF ED(GE OF ASPHALT 20021: EAST FROM THE CENTERLINE OF FFREEPORT PARKWAY, ELEV= 512.16 BM~ 7 " [] " CUT SET ON THE TOP OF A CONCRETE ST0f;RM INLET ON THE LEFT SIDE OF FREEPORT PARKWAY, BEING 80J::l: SOUTH OF THE NORTH ENTRANCE TO 6.],5 FREEPORT PARKWA'Y, ELEV= 516.08 BM# 8 "[]" CUT SET ON THE TOP OF THE BACK OF CUI~B WEST OF A ONE STORY CONCRETE TILT-wALL BUILDING AT 83~ FREEPORT PARKWAY, ELEV= 514.77 S.A,&:M,G, RR SURVEY - ABSTRACT NO. 1439 JOHN VEST SURVEY - ABSTRACT NO. 1508 %~ w/ mANS. ,O,L C REEK VIE ,DRIVE CHL' ~ (VARIABLE WIDTH R.O.W,) ouY / 5 ' O AKJ S / / / / / / / X X X WV", HOLLY HOLLY x x -X X X b= 40T.6'51" R~t411.12o L=g96.1 1~LS / o 7 24." 15 30 60 90 GRAPHIC SCALE IN FEET EM 0 PPe iCV® COo 8OLLARD ELECTRIC METER POWER POLE LIGHT STANDARD WATER METER WATER VALVE IRRIGATION CONTROL VALVE FIRE HYDRANT CLEANOUT MANHOLE 1/2-INCH IRON ROD W/"PACHECO KOCH" CAP SET PROPERTY LINE FENCE -- OHL'-- OVERHEAD UTILiTY LINE --¢w UNDERGROUND WATER LINE E- UNDERGROUND ELECTRIC UNE r UNDERGROUND TELEPHONE LINE c- UNDERGROUND CABLE UNE --ess UNDERGROUND SANITARY SEWER U,NE 18SUED FOR PRELIMINARY PRICING PURPOSES ONLY (SUBJECT TO REVISION PRIOR TO CONSTRUCTION) THESE DOCUMENTS HAVE BEEN PREPARED BY THE ENGINEER WITH THE INTENT OF COMPLYING WITH ALL CITY STANDARD REQUIREMENTS. THESE DOCUMENTS HAVE NOT BEEN APPROVED ANO RELEASED FOR CONSTRUCTION BY THE CITY AS OF THIS DATE AND, THEREFORE, REVISIONS MAY BE REQUIRED PRIOR TO CONSTRUCTION, BY ANY USE OF THESE DOCUMENTS, THE USER AFFIRMS THEIR UNDERSTANDING OF THE PRELIMINARY STATUS OF THE PLANS ANO THE POTENqAL FOR REVISION PRIOR TO ANY CONSTRUCTION, \ PRELIMINARY NOT FOR CONSTRUCTION THIS DOCUMENT tS ISSUED FOR THE PURPOSE OF SCHEMATIC REVIEW ONLY AND tS NOT INTENDED FOR PERMITTING, BIDOING, OR CONSTRUCTION PURPOSES. PLANS PREPARED UNDER THE DIRECT SUPERVISiON OF STEVEN A. MARKUSSEN. P,E. TEXAS REGISTRATION NO, 70090 DATE: 08/0a/2004 N D't 'ke CONSTRUCTION 5495 Belt Line Ro~d Suite 360 Dallas, TX 75240 Phone: (972) 361-6700 F~x: (972) 361-6800