Con. Water & San. Sewer Plan P2o
I
I
I HILLWOOD FUND NO. 1, L.P.
I (VOL, 2003006, PO. 00074)
I
--x x x
1-8%8
OHL
?
ePp OHL
~' o_o'~'~' ~ _ _ _
X X X X X
9EDUCER
FREEPORT Xll
LOT 7, BLOCK A
DUKE-FREEPORT ADDITION
2.570 ACRES
42,670 SF)
TEXAS DUOAN LIMITED PARTNERSHIP
(VOL. 2000251, PO, 2678)
F.F. = 521.OO
INSTALL 4' DiA. SSMH
FL 514.50
-INCH IRON RO0
CAP
FOUND
INSTALL:
8'x6' REDUCER
1-F,H.
II
Ii
PROP. 15'x10'
WTR. ESMT,
/
/
/
4' DIA, SSMH
CONNECT TO EX. 8' SS
-' CUT IN/
CONCRETE I¢OUN O
/
/
/
/
/
LS
/
/
/
/
/
/
/
/
/
/
/
/
/
/
CONNECT TO EX. 12" WTR.
INSTALL:
2-12"x2' TAPPING SADDLE W/VALVE
4-2' W~ (DOM)
t-2' WM ORR.)
!
!
,/
OHL
, PP ,OHL
PROPOSED FDC
REFER TO FIRE PROTECTION
PLANS FOR DETAILS
--X X
IN STALL:
__ 1-8"x45' BEND
I,NSTALL:
1- 8'x4-5' BEND
~ J
INSTALL:
1-8"x6" TEE
1-8" VALVE
1-F.H.
1-8" VALVE
CONNECT TO EX. 12'
INSTALL:
1-Z' W~ (DOM)
1-2" WM
1-DET, CHK
/
/
/
/
/
/
/
/
/
/
/
/
/
?
!
!
/
/
5' 1.2 V1E
/
/
/
/
/
!
/
/
/
,>
!
!
!
!
BENCH MA tTK L /$ T '
BM~I 2
"[]" CUT ON THE NW CORNER OF CONCRETE PAD) ON THE
NORTH SIDE OF BETHAL ROAD, 20:t: NORTH OF ED(GE OF
ASPHALT 20021: EAST FROM THE CENTERLINE OF FFREEPORT
PARKWAY,
ELEV= 512.16
BM~ 7
" [] " CUT SET ON THE TOP OF A CONCRETE ST0f;RM INLET ON
THE LEFT SIDE OF FREEPORT PARKWAY, BEING 80J::l: SOUTH OF
THE NORTH ENTRANCE TO 6.],5 FREEPORT PARKWA'Y,
ELEV= 516.08
BM# 8
"[]" CUT SET ON THE TOP OF THE BACK OF CUI~B WEST OF A
ONE STORY CONCRETE TILT-wALL BUILDING AT 83~ FREEPORT
PARKWAY,
ELEV= 514.77
S.A,&:M,G, RR SURVEY - ABSTRACT NO. 1439
JOHN VEST SURVEY - ABSTRACT NO. 1508
%~ w/ mANS. ,O,L
C REEK VIE
,DRIVE
CHL' ~
(VARIABLE WIDTH R.O.W,) ouY
/
5 ' O AKJ
S
/
/
/
/
/
/
/
X X X
WV",
HOLLY
HOLLY
x x -X X X
b= 40T.6'51"
R~t411.12o
L=g96.1
1~LS
/ o
7
24."
15 30 60 90
GRAPHIC SCALE IN FEET
EM 0
PPe
iCV®
COo
8OLLARD
ELECTRIC METER
POWER POLE
LIGHT STANDARD
WATER METER
WATER VALVE
IRRIGATION CONTROL VALVE
FIRE HYDRANT
CLEANOUT
MANHOLE
1/2-INCH IRON ROD
W/"PACHECO KOCH" CAP SET
PROPERTY LINE
FENCE
-- OHL'-- OVERHEAD UTILiTY LINE
--¢w UNDERGROUND WATER LINE
E- UNDERGROUND ELECTRIC UNE
r UNDERGROUND TELEPHONE LINE
c- UNDERGROUND CABLE UNE
--ess UNDERGROUND SANITARY SEWER U,NE
18SUED FOR PRELIMINARY PRICING PURPOSES ONLY
(SUBJECT TO REVISION PRIOR TO CONSTRUCTION)
THESE DOCUMENTS HAVE BEEN PREPARED BY THE ENGINEER WITH THE INTENT OF
COMPLYING WITH ALL CITY STANDARD REQUIREMENTS. THESE DOCUMENTS HAVE NOT
BEEN APPROVED ANO RELEASED FOR CONSTRUCTION BY THE CITY AS OF THIS DATE
AND, THEREFORE, REVISIONS MAY BE REQUIRED PRIOR TO CONSTRUCTION, BY ANY
USE OF THESE DOCUMENTS, THE USER AFFIRMS THEIR UNDERSTANDING OF THE
PRELIMINARY STATUS OF THE PLANS ANO THE POTENqAL FOR REVISION PRIOR TO
ANY CONSTRUCTION,
\
PRELIMINARY
NOT FOR CONSTRUCTION
THIS DOCUMENT tS ISSUED FOR THE
PURPOSE OF SCHEMATIC REVIEW ONLY
AND tS NOT INTENDED FOR PERMITTING,
BIDOING, OR CONSTRUCTION PURPOSES.
PLANS PREPARED UNDER THE DIRECT
SUPERVISiON OF STEVEN A. MARKUSSEN. P,E.
TEXAS REGISTRATION NO, 70090
DATE: 08/0a/2004
N
D't 'ke
CONSTRUCTION
5495 Belt Line Ro~d
Suite 360
Dallas, TX 75240
Phone: (972) 361-6700
F~x: (972) 361-6800