Loading...
Detail SP for Lots 6&7 U o o ~J~O ,. - ~XU UTIUTY EASEMENT I / (VOL2001065, PO. 57 C~7016) 1- S,A.&M.G. RR SURVEY - ABSTRACT NO, 14,39 JOHN VEST SURVEY - ABSTRACT NO. 1508 NO. ~, LP. 17tl,59' zI I 1o' u~u~' -- I I I T~P,) "-, "'-,. r" 10. ONCOR ES'MT. "'-.. "..../' (VOL, 2002125, ~ 0070) DRAINAGE EASEMENT I'(VOL 2001028, PO, 5904) I I I PROPOSED PRIVATE / / 20' PRWATE DRAINAGE ESMT / / ~ [] [] ~'-7' [] [] // , PROPOSED OSED DUMPSTER TRANSFORMER FREEPORT XI LOT 6, BLOCK A DUKE-FREEPORT ADDITION 5,559 ACRES 72,861 SF) 700' TEXAS DUOAN LIMITED PARTNERSHIP (VOL. 2000251, PO. 2678) F.F. = 521.00 30'R X 2(~ ONCOR ESMT, (~ 20~.Z125, I:>g. 0070) '%)-::r:?.*C~...;:3: (VOl., 2002125, Pg, 0070) ULINE LOT 5, BLOCK A D. UKE-FREEPORT ADDITION ( VOL. 2002125, PO. 70) 24.' FIRELANE &: ACCESS EASEMENT VOL 2002125, PG. 0070) ,/ ,/ N 00'52'27" E SITE DATA INFORMATION 1. PARKING REQUIREMENTS: LOT 6 FP XI OFFICE: 35,000 SF (1/300) = 117 FP XI WAREHOUSE: 105,000 SF(1/5000 *)= 21 LOT 7 FP Xll OFFICE: 17,500 SF (1/~0.0) -'59 FP XII WAREHOUSE: 52,500 (1/5000 *) = 11 TOTAL CARS REQUIRED: = 2O8 2. PARKING PROVIDED: LOT6 = 245 I 8 HCl LOT 7 = 188 ~..7 HO TOTAL PROVIDED = 431 CARS (15 H.C.) BUILDING AREA: LOT 6 FP XI OFFICE = ~5,000 SF FP Xl WAREHOUSE = 105,000 SF LOT 7 FP Xll OFFICE = 17,500 SF FP XII WAREHOUSE = 52,500 SF TOTAL = 210,000 SF LOADING: FP Xl DOCKS = 59 DOORS FP Xll DOCKS = 19 DOORS TOTAL = 58 DOORS 4. SITE COVERAGE: ACRES FOOTPRINT S.F. SITE COVERAGE LOT 6 572,862 S.F. 140,000 S.F. ,.37,55% LOT 7 242,670 S.F, 70,000 S.F, 28.85% 5. BUILDING HEIGHT: 30.0' 6. ZONING DUKE FREEPORT ADDITION - PD186-R5 fCV® lev )'R "P/C// / / 15' UTlUTY ESMT.,. VOL 2002125, PG. 0070)1 JOHN VEST SURMEY - ABSTT~ACT NO, 1508 ~cv· ;ANDY LAKE ROAD 150' TRANSFORMER TEXAS DUGAN (VOL. RRELANE & F_.ASI~ENT I I VICINITY MAP (NOT TO '.SCALE) 570' FREEPORT Xtl 5' LOT 7, BLOCK A DUKE-FREEPORT ADDITION 2.570 42,670 LI ITED PARTNERSHIP 2000251, PG. 2676) I F.F. = 521.00 PROPOSED STAMPED BRICK PAVER BAND J // / / / / / / / / / / / / / / / / / LANDSC ,/ / / / / / / / / / f / // / A / / · / // / / / / /J / ./ ~ED MEDIAN OPENING PREVIOUSLY/' PROPOSED STAMPED BRICK PAVER ;. --~1' FREEPORT X '" .. ' :--FLOT 3R, BLOCK a '(,/,/~"DU~E=FREEPORT ADDITIO~I ~.,'' '_~(.]L~CO[.. 2003046, PO. 35 /T--519,88' d 1'55"E CD=975,61' J 0 5 lO 60 120 180 GRAPHIO SOALE IN FEET × -- OHU-- )'58't2' E 22. 83' PRELIMINARY NOT FOR CONSTRUCTION THIS DOCUMENT IS ISSUED FOR THE PURPOSE OF SCHEMATIC REVIEW ONLY AND IS NOT INTENDED FOR PERMITTING, BIDDING, OR CONSTRUCTION PURPOSES, PLANS PREPARED UNDER THE DIRECT SUPERVISION OF STEVEN A. MARKUSSEN, P.E. TEXAS RE01STRATION NO. 70090 DATE: 06/18/2004 e. BOLLARD EMO ELECTRIC METER PP. POWER POLE LS~ LIGHT STANDARD wvo WATER METER w% WATER VALVE icve IRRIGATION CONTROL VALVE rH<~' FIRE HYDRANT coo CLEANOUT u~ ~ MANHOLE 1/2-tNCH IRON PO0 IRS W/"PACHECO KOCH" CAP SET PROPERTY LINE FENCE OVERHEAD UT1LJTY LiNE UNDERGROUND WATER LINE UNDERGROUND ELECTRIC LiNE UNDERGROUND TELEPHONE LINE UNDERGROUND CABLE LiNE UNDERGROUND SANITARY SEWER LINE ATTACHED TO C.C. PACKET ISSUED FOR PRELIMINARY PRICING PURPOSES ONLY (SUBJECT TO REVISION PRIOR TO CONSTRUCTION) THESE DOCUMENTS HAVE BEEN PREPARED BY THE ENGINEER WITH THE INTENT OF COMPLYING WITH ALL CITY STANDARD REQUIREMENTS. THESE DOCUMENTS HAVE NOT BEEN APPROVED ANO RELEASED FOR CONSTRUCTION BY THE CITY AS OF THIS DATE AND, THEREFORE. REVISIONS MAY BE REQUIRED PRIOR TO CONSTRUCTION, BY ANY USE OF THESE DOCUMENTS, THE USER AFFIRMS THEIR UNDERSTANDING OF' THE PRELIMINARY STATUS OF THE PLANS AND THE POTENTIAL FOR REVISION PRIOR TO ANY CONSTRUCTION. * 1 SPACE PER 5,000 s.f. (PER PD-186RS-LI ZONING) CONSTRUCTION 5495 Belt Line Ro~.d Suite 560 Dallas, TX 75240 Phooe: [972) ~61-6700 Fax: (972) 561-6800 8 Certified By: Drawing Number: SP 1 Duke Job Number: FPN011-O00 2052-04.058